I want to search for...

Permit #2019110970

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-00690-0050
CONDITIONED SPACE: 1582 sqft
CONDITIONED SPACE: 1582 sqft
GARAGE: 518 sqft
GARAGE: 518 sqft
OPENED PORCH (WITH ROOF) : 325 sqft
OPENED PORCH (WITH ROOF) : 325 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 4970 sqft
Block: 00690
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 386-864-2199
Location Address: 1 LINDEN PL
Type: DU - DUPLEX
Issue Date: 01/16/2020
NOC: RECORDED
Applicant name: MAXIM TARANNIK
Owner: NAY PAT & ANNIE

Address

1 LINDEN PL

PALM COAST, FL 32164

Lot: 0050
Contracted Stated Job Value: ¤343,000.00
Job Description: DUPLEX
Type: CN

Contractor

GOLDEN MAGNOLIA, INC
Status Location Address State License Number Phone
INACTIVE

1 ROCKEFELLER DRIVE

PALM COAST, FL 32164

RR282811984 (Exp: 08/31/2025) 386-447-7007

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
STEPHEN COURTEAUX
Status Location Address State License Number Phone Fax
ACTIVE

85 North Yonge Street

Ormond Beach, FL 32174

EC13001748 (Exp: 08/31/2026) (386) 672-4900 386-676-7472

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/21/2020 FINAL APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION need to change breaker for side A AC unit 30 amp installe 25amp needed...need sch 40 outside future plumbing...need to install service mast roof flange to manufacture specs...need to cover exposed conductor at kitchen exhaust...need to seal hole exterior by meter.
U -UTILITY RESIDENTIAL FINAL 10/19/2020 FINAL APPROVED JHARDING
BLD - BUILDING FINAL 10/19/2020 Disapproved - NO FEE JCOLASANTI
Note: need to change breaker for side A AC unit 30 amp installe 25amp needed...need sch 40 outside future plumbing...need to install service mast roof flange to manufacture specs...need to cover exposed conductor at kitchen exhaust...need to seal hole exterior by meter. replace breaker no 12 at unit A
ROW - FINAL INSPECTION 10/16/2020 APPROVED RGROSS
Note: THIS IS A REINSPECTION REMOVE ADVERTISEMENT SIGN AND DOC BOX SIGN FROM THE 25 FT CORNER LOT ROW.
ROW FIELD SURVEY /GRADING CERTIFICATION 10/15/2020 APPROVED RGROSS
Note: THIS IS A REINSPECTION The subject lots drainage must not negatively impact any adjacent property. Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW - STORMWATER FINAL 10/15/2020 APPROVED RGROSS
Note: THIS IS A REINSPECTION REAR PROPERTY LINE WILL ALLOW STORM WATER TO FLOW ONTO THE ADJACENT LOT. RIGHT REAR PROPERTY MISSING ABOUT 80 SQ FT OF SOD. RIGHT FRONT PROPERTY LINE BARE EARTH ON ADJACENT LOT NEEDS SEED AND STRAW.
ROW - FINAL INSPECTION 10/15/2020 Disapproved - NO FEE RGROSS
Note: REMOVE ADVERTISEMENT SIGN AND DOC BOX SIGN FROM THE 25 FT CORNER LOT ROW.
ROW - STORMWATER FINAL 10/07/2020 Disapproved - NO FEE RGROSS
Note: REAR PROPERTY LINE WILL ALLOW STORM WATER TO FLOW ONTO THE ADJACENT LOT. RIGHT REAR PROPERTY MISSING ABOUT 80 SQ FT OF SOD. RIGHT FRONT PROPERTY LINE BARE EARTH ON ADJACENT LOT NEEDS SEED AND STRAW.
ROW - FINAL APRON (AFTER POUR) 10/07/2020 APPROVED RGROSS
Note: THIS IS A REINSPECTION clean colver end ,the right side pipe on the right driveway colvert end has concrete inside please removed
ROW - FINAL APRON (AFTER POUR) 09/30/2020 Disapproved -FEE REQUIRED GBERTOLA
Note: clean colver end ,the right side pipe on the right driveway colvert end has concrete inside please removed
ROW FIELD SURVEY /GRADING CERTIFICATION 09/29/2020 Disapproved - NO FEE GBERTOLA
Note: The subject lots drainage must not negatively impact any adjacent property. Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
FINAL SURVEY (OFFICE USE ONLY) 09/29/2020 APPROVED GBERTOLA
ROW- PRE-APRON (PRE-POUR) 07/23/2020 APPROVED RGROSS
Note: THIS IS A REINSPECTION CULVERT ON THE LEFT SIDE IS NOT PARALLEL WITH THE ROAD. STAND AT THE CORNER STOP SIGN AND LOOK DOWN THE SWALE. 7/23/20 - READY TO POUR
ROW- PRE-APRON (PRE-POUR) 07/22/2020 Disapproved - NO FEE RGROSS
Note: CULVERT ON THE RIGHT SIDE IS NOT PARALLEL WITH THE ROAD. STAND AT THE CORNER STOP SIGN AND LOOK DOWN THE SWALE. LEFT SIDE OUT OF LOTERANCE. TILTED IN THE WRONG DIRECTION. SEE SWALE PLAN
ELECTRIC - EARLY POWER 07/14/2020 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 10:23 am
GRAVITY SEWER TEST 07/02/2020 APPROVED JGIBSON
U - SEWER TIE IN 07/02/2020 APPROVED JGIBSON
PEP TANK INSTALLATION REQUEST 06/12/2020 APPROVED CSTONE
INSULATION 05/07/2020 APPROVED JCOLASANTI
ALL ROUGH 04/28/2020 APPROVED - AS NOTED JCOLASANTI
Note: will need to call for inspection to test shower lining when installed right side....left side: need to seal tub trench...need to finish framing hallway adjacent to bedroom...need water presure and DWV test by insulation...need to frame elecrtric panel
LATH/BRICK/ WATER BARRIER 04/21/2020 APPROVED JCOLASANTI
ROOF VALLEY & METAL 04/06/2020 APPROVED JCOLASANTI
FIREWALL 04/06/2020 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/31/2020 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION not ready still sheathing roof
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/27/2020 Disapproved -FEE REQUIRED JCOLASANTI
Note: not ready still sheathing roof
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/25/2020 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 03/16/2020 APPROVED JCOLASANTI
FOUND SURVEY APPROVED (OFFICE) 03/02/2020 APPROVED TBAKER
MONOLITHIC SLAB 02/18/2020 APPROVED JCOLASANTI
Note: THIS IS A REINSPECTION
MONOLITHIC SLAB 02/13/2020 Disapproved -FEE REQUIRED JCOLASANTI
Note: FOOTINGS & PIPES ABOVE 45-degree BEARING PLANE, FBC 2604.4 SHALL NOT EXTEND BELOW THE 45-degree BEARING PLANE OF THE BOTTOM EDGE OF THE FOOTING WHEN RUNNING PARRALEL.... MISSING UFER GROUND .NEC..250.52(3)
PLUMBING 1ST ROUGH UNDERGROUND 02/07/2020 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 01/17/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
PLFM COMPLETE 03/03/2020 03/03/2020
Note: Released By: JMYERS The structure is outside of Special Flood Hazard Area. Elevation Certificates are not required
ENGIN1 COMPLETE 03/02/2020 03/02/2020
Note: Released By: TBAKER
BLD COMPLETE 12/20/2019 01/13/2020
Note: Released By: FREODICA
SW1 COMPLETE 12/20/2019 12/30/2019
Note: Released By: CTROHA
SWALE COMPLETE 12/09/2019 01/07/2020
Note: Released By: TBAKER
BLD HOLD 12/02/2019 12/13/2019
Note: Held By: FREODICA 1. Sheet 2-Foundation Plan: Minimum depth of exterior footing shall be placed not less than 12 inches below the undisturbed ground surface per FBCR 6th ed. sec. R403.1.4. 2. Product Approval Sheet:as required per FS 553.842: a. FL 8228.11R7 or R7 for exterior window and FL 1414170.15R7 for garage door can not be found on Florida Product Approval Listing. Verify the numbers. b. Clarify FL 15349 as this number was used for both single hung window and for fixed windows. c. FL number for soffits is missing. d. Structural components are incomplete. Wood connector/anchors, truss plates are missing. Provide complete information on Product Approval sheet. If items are not applicable to the jod, indicate N/A. FReodica -386-986-4734.
CUSVC COMPLETE 12/02/2019 12/03/2019
Note: Released By: HHAND
ELEC COMPLETE 12/02/2019 12/06/2019
Note: Released By: JMUNSON
ENGIN1 COMPLETE 12/02/2019 12/09/2019
Note: Released By: TBAKER
LOCATE COMPLETE 12/02/2019 12/04/2019
Note: Released By: CSTONE
MECH COMPLETE 12/02/2019 12/04/2019
Note: Released By: CPISCITELLI
PLUM COMPLETE 12/02/2019 12/13/2019
Note: Released By: FREODICA
SW1 COMPLETE 12/02/2019 12/03/2019
Note: Released By: RGROSS
UD1 COMPLETE 12/02/2019 12/05/2019
Note: Released By: AHALL
ZON COMPLETE 12/02/2019 12/03/2019
Note: Released By: ELENS

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 10/14/2020
REINSPECTION FEE ¤40.00 09/29/2020
REINSPECTION FEE ¤40.00 09/29/2020
CONTRACTOR CHANGE ¤40.00 09/29/2020
ELECTRIC FEE ¤315.00 01/16/2020
3% FIRE IMPACT FEE CREDIT (¤13.40) 01/16/2020
IMPACT FEE FIRE ¤446.76 01/16/2020
IMPACT FEE PARKS ¤1,698.48 01/16/2020
IMPACT FEE SCHOOL ¤7,200.00 01/16/2020
MECHANICAL FEE ¤315.00 01/16/2020
WATER -IRRIGATION INSPECTION ¤50.00 01/16/2020
3% PARKS IMPACT FEE CREDIT (¤50.95) 01/16/2020
PLAN CHECK FEE ¤170.00 01/16/2020
PLUMBING FEE ¤315.00 01/16/2020
NEW RESIDENTIAL INSPECTIONS ¤850.00 01/16/2020
SITE PLAN 20 ¤20.00 01/16/2020
SURCHARGE FS 533.721 ¤18.35 01/16/2020
SURCHARGE - FS 468.631 ¤27.53 01/16/2020
STORM WATER PERMIT FEES ¤80.00 01/16/2020
TRANSPORTATION IMPACT FEE ¤2,532.00 01/16/2020
3% TRANS IMPACT FEE CREDIT (¤75.96) 01/16/2020
SEWER CREDIT (¤4,782.75) 01/16/2020
SEWER INSPECTION ¤25.00 01/16/2020
SEWER CAPITAL FACILITY ¤9,192.14 01/16/2020
WATER CAPITAL FACILITY FEE ¤6,748.36 01/16/2020
METER - DEPOSIT ¤120.00 01/16/2020
WATER- TURN ON ¤50.00 01/16/2020
ADMIN FEE ¤20.00 01/16/2020
CONNECTION FEES ¤2,005.76 01/16/2020
Fees Total Due: ¤0.00 Total Paid: ¤27,436.32