I want to search for...
Permit #2019120423
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7023-00100-0110 |
| Block: 00100 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 321-332-0001 |
| Location Address: 62 WHISPERING PINE DR |
| Type: ME - MECHANICAL |
| Issue Date: 12/13/2019 |
| NOC: RECORDED |
| Applicant name: CAREY L ZARM |
| Owner: HUNT DONALD F JR & PATRICIA J H&W LIFE ESTATE |
|
Address 62 WHISPERING PINE DR PALM COAST, FL 32164 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤17,600.00 |
| Job Description: HVAC CHANGEOUT- 3 ton/ 21.5 seer/ hp |
| Type: CN |
Contractor
SERVICE EXPERTS HEATING & AIR CONDITIONING
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| CANCEL |
1725 S. NOVA ROAD DAYTONA BEACH, FL 32119 |
UNIT D-5 DAYTONA BEACH, FL 32119 |
CAC1817129 (Exp: 08/31/2020) | 321-332-0001 | 321-281-4733 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 01/08/2020 | FINAL APPROVED | CPISCITELLI |
| Note: THIS IS A REINSPECTION | |||
| HVAC ROUGH | 12/17/2019 | CANCELLED BY INSPECTOR | CPISCITELLI |
| HVAC FINAL | 12/17/2019 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: 1. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 (ODU needs to be 3 inches above grade. Need to install hurricane pad) 2. MOCP RATING NOT MATCHING BREAKERS MFBC 1303. (ODU calls for max 30 AMP. There is a 35 AMP in panel) |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/11/2019 | 12/12/2019 |
| Note: Released By: CPISCITELLI |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 01/06/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/13/2019 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/13/2019 |
| ADMIN FEE | ¤20.00 | 12/13/2019 |
| INSPECTION 40 | ¤40.00 | 12/13/2019 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤104.00 |