I want to search for...

Permit #2019120708

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00160-0040
CONDITIONED SPACE: 1817 sqft
GARAGE: 433 sqft
OPENED PORCH (WITH ROOF) : 186 sqft
OPENED PORCH (WITH ROOF) : 38 sqft
Total Square Footage: 2474 sqft
Block: 00160
Subdivision: 2211 - SECTION 59-SEMINOLE PARK
Job Phone: (386)437-1508
Location Address: 1 SEA SWIRL PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 01/28/2020
NOC: RECORDED
Applicant name: TAMMI SUE MARQUIS
Owner: JM PROPERTIES X LLC

Address

29 COLUMBUS COURT

PALM COAST, FL 32137

Lot: 0040
Contracted Stated Job Value: ¤180,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GULFSTREAM HOMES & CONSTRUCTION, LLC
Status Location Address State License Number Phone Fax
INACTIVE

PO BOX 1092

BUNNELL, FL 32110

CRC1326418 (Exp: 08/31/2026) (386)437-1508 386-437-9769

Sub Contractors

JAMES CRAIG FISHER
Status Location Address State License Number Phone
ACTIVE

PO BOX 451

BUNNELL, FL 32110

CAC1819807 (Exp: 08/31/2026) 386-222-9549
ARTHUR J PASCOE
Status Location Address State License Number Phone
ACTIVE

PO BOX 730007

ORMOND BEACH, FL 32174

EC13007168 (Exp: 08/31/2026) 386-547-6439
DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/28/2020 FINAL APPROVED FWILLIS
Note: THIS IS A REINSPECTION At the time of my Inspection workers still laying tile and painting, Majority of outlet covers were off and laying on the floor. To many obstacles and people to maneuver around to perform Inspection.
U -UTILITY RESIDENTIAL FINAL 07/24/2020 FINAL APPROVED JHARDING
Note: Approved.
BLD - BUILDING FINAL 07/24/2020 Disapproved - NO FEE FWILLIS
Note: At the time of my Inspection workers still laying tile and painting, Majority of outlet covers were off and laying on the floor. To many obstacles and people to maneuver around to perform Inspection.
FINAL SURVEY (OFFICE USE ONLY) 07/23/2020 APPROVED KHOWELL
ROW FIELD SURVEY /GRADING CERTIFICATION 07/23/2020 APPROVED KHOWELL
ROW - STORMWATER FINAL 07/23/2020 FINAL APPROVED KHOWELL
ROW - FINAL APRON (AFTER POUR) 07/23/2020 APPROVED KHOWELL
FINAL SURVEY (OFFICE USE ONLY) 07/15/2020 Disapproved - NO FEE KHOWELL
Note: VERIFY OUTSIDE GRADE ELEVATION AT THE FOUNDATION REQUIRED TO BE A MINIMUM 4" FOR BLOCK CONSTRUCTION AND 6" FOR WOOD FRAME CONSTRUCTION PER FLORIDA BUILDING CODE CHAPTER 4 R404.1.6
ELECTRIC - EARLY POWER 06/18/2020 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 9:50
ROW- PRE-APRON (PRE-POUR) 06/17/2020 APPROVED - AS NOTED KHOWELL
ROW- PRE-APRON (PRE-POUR) 06/16/2020 Disapproved - NO FEE KHOWELL
Note: COULD NOT LOCATE BENCH MARK IN THE INTERSECTION AND HOLE FOR PROPERTY LINE NAIL AND DISK THE HOLE IS NOT BIG ENOUGH TO PUT ROD IN. ENDS OF PIPE DAMAGED / BENT NEED TO BE STRAIGHTENED OUT. 4" MINIMUM THICK CONCRETE IS REQUIRED ABOVE THE ROW SOME AREAS NEED TO BECXUT DOWN
U - SEWER TIE IN 06/09/2020 APPROVED JGIBSON
Note: THIS IS A REINSPECTION P-2503.2 CONCEALMENT NEED TO UNCOVER CONNECTION AT PEP TANK AREA
GRAVITY SEWER TEST 06/09/2020 APPROVED JGIBSON
Note: THIS IS A REINSPECTION P-2503.2 CONCEALMENT . NEED TO UNCOVER PIPE
GRAVITY SEWER TEST 06/08/2020 Disapproved -FEE REQUIRED JGIBSON
Note: P-2503.2 CONCEALMENT . NEED TO UNCOVER PIPE
U - SEWER TIE IN 06/08/2020 Disapproved - NO FEE JGIBSON
Note: P-2503.2 CONCEALMENT NEED TO UNCOVER CONNECTION AT PEP TANK AREA
U - SEWER TIE IN 05/27/2020 CANCELLED BY APPLICANT WEB
GRAVITY SEWER TEST 05/27/2020 CANCELLED BY APPLICANT WEB
PEP TANK INSTALLATION REQUEST 05/13/2020 APPROVED CSTONE
LATH/BRICK/ WATER BARRIER 05/06/2020 APPROVED FWILLIS
INSULATION 04/27/2020 APPROVED FWILLIS
ALL ROUGH 04/22/2020 APPROVED FWILLIS
ROOF VALLEY & METAL 04/13/2020 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/06/2020 APPROVED - AS NOTED FWILLIS
Note: Truss Pullout Needs to be stamped by Engineer since it has the new layout. Inspect on next Inspection.
TIE BEAM / LINTEL 03/18/2020 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 03/05/2020 APPROVED TBAKER
MONOLITHIC SLAB 02/27/2020 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 02/24/2020 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 02/05/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN HOLD 07/17/2020 07/17/2020
Note: Held By: JMONTARULI The Termite Certificate is for a different address
BADMIN COMPLETE 07/17/2020 07/17/2020
Note: Released By: JMONTARULI
ENGIN1 COMPLETE 03/04/2020 03/05/2020
Note: Released By: TBAKER
BLD COMPLETE 01/27/2020 01/27/2020
Note: Released By: JPI
ZON COMPLETE 01/16/2020 01/16/2020
Note: Released By: ELENS
BLD HOLD 01/16/2020 01/17/2020
Note: Held By: JPI 1. Comments still not addressed on floor plan. Sending review back to the Palm Coast Building Department and requested that a Palm Coast employee finish the review.
UD1 COMPLETE 01/10/2020 01/14/2020
Note: Released By: AHALL
ENGIN1 COMPLETE 01/10/2020 01/13/2020
Note: Released By: TBAKER
ZON HOLD 01/10/2020 01/10/2020
Note: Held By: ELENS Eight foundation plantings are required in front of the house.
ELEC COMPLETE 01/10/2020 01/13/2020
Note: Released By: JMUNSON
BLD HOLD 01/10/2020 01/13/2020
Note: Held By: JPI 1. Repeating comments. We reviewed the file directory and did not see the revised floor plan. Please resubmit. Here are the repeating comments. 2. Please add the label for a Vacuum Breaker on the hose bib. (R2902.4) 3. Garage door entrance. R302.5.1 Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. Please label the door option. 4. Provide safety device at water heater (tap and thermal expansion device). Add note. P607.3 5. Add label with note at garage walls. R302.5.2 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage.
SW1 COMPLETE 01/10/2020 01/10/2020
Note: Released By: CTROHA
SWALE COMPLETE 01/02/2020 01/27/2020
Note: Released By: TBAKER
BLD HOLD 12/20/2019 12/28/2019
Note: Held By: JPI 1. Please add the label for a Vacuum Breaker on the hose bib. (R2902.4) 2. Garage door entrance. R302.5.1 Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. Please label the door option. 3. Provide safety device at water heater (tap and thermal expansion device). Add note. P607.3 4. Add label with note at garage walls. R302.5.2 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage.
CUSVC COMPLETE 12/20/2019 12/20/2019
Note: Released By: HHAND
ELEC HOLD 12/20/2019 12/23/2019
Note: Held By: JMUNSON Need outlets by bathroom sinks. NEC 2014 art 210.52 (D)
ENGIN1 COMPLETE 12/20/2019 01/02/2020
Note: Released By: TBAKER
LOCATE COMPLETE 12/20/2019 12/23/2019
Note: Released By: CSTONE
MECH COMPLETE 12/20/2019 12/20/2019
Note: Released By: CPISCITELLI
PLUM COMPLETE 12/20/2019 12/28/2019
Note: Released By: JPI
SW1 HOLD 12/20/2019 12/30/2019
Note: Held By: CTROHA Applicant needs to provide FFE for improved adjacent lots
UD1 COMPLETE 12/20/2019 12/27/2019
Note: Released By: LFITZGERALD
ZON HOLD 12/20/2019 12/20/2019
Note: Held By: TDOAK 1. Site plan/survey must show total square footage of lot. 2. Site plan/survey has incorrect legal description (section #). 3. Site plan/survey must show width of proposed driveway and front walkway. 4. Site plan/survey must show A/C pad with dimensions. 5. Landscape plan must show 5 trees. 6. Landscape plan must have a minimum of 4 foundation plantings on right side (the 7 gallon shrubs for screening the mechanical equipment do not count towards this number) and a minimum of 6 foundation plantings on the street side. 7. Exterior house color is blue and does not meet the LDC definition of an earth tone or a pastel. 8. Elevation page must have sides of home labeled as right and left. 9. Banding is required around all windows and doors facing the public right-of-way.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/03/2020
CONTRACTOR CHANGE ¤40.00 02/25/2020
ELECTRIC FEE ¤197.40 01/28/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 01/28/2020
IMPACT FEE FIRE ¤223.38 01/28/2020
IMPACT FEE PARKS ¤849.24 01/28/2020
IMPACT FEE SCHOOL ¤3,600.00 01/28/2020
IMPACT FEE TRANSPORTATION ¤1,632.00 01/28/2020
MECHANICAL FEE ¤197.40 01/28/2020
WATER -IRRIGATION INSPECTION ¤25.00 01/28/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 01/28/2020
PLAN CHECK FEE ¤91.60 01/28/2020
PLUMBING FEE ¤197.40 01/28/2020
NEW RESIDENTIAL INSPECTIONS ¤458.00 01/28/2020
SITE PLAN 20 ¤20.00 01/28/2020
SURCHARGE FS 533.721 ¤10.90 01/28/2020
SURCHARGE - FS 468.631 ¤16.35 01/28/2020
STORM WATER PERMIT FEES ¤80.00 01/28/2020
3% TRANS IMPACT FEE CREDIT (¤48.96) 01/28/2020
SEWER CREDIT (¤1,147.00) 01/28/2020
SEWER INSPECTION ¤25.00 01/28/2020
SEWER CAPITAL FACILITY ¤4,596.07 01/28/2020
WATER CAPITAL FACILITY FEE ¤3,374.18 01/28/2020
METER - DEPOSIT ¤60.00 01/28/2020
WATER- TURN ON ¤25.00 01/28/2020
ADMIN FEE ¤20.00 01/28/2020
CONNECTION FEES ¤1,002.88 01/28/2020
Fees Total Due: ¤0.00 Total Paid: ¤15,553.66