I want to search for...
Permit #2019120708
Permit Details
Status: COED
| Parcel Id: 07-11-31-7059-00160-0040 |
| CONDITIONED SPACE: 1817 sqft |
| GARAGE: 433 sqft |
| OPENED PORCH (WITH ROOF) : 186 sqft |
| OPENED PORCH (WITH ROOF) : 38 sqft |
| Total Square Footage: 2474 sqft |
| Block: 00160 |
| Subdivision: 2211 - SECTION 59-SEMINOLE PARK |
| Job Phone: (386)437-1508 |
| Location Address: 1 SEA SWIRL PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/28/2020 |
| NOC: RECORDED |
| Applicant name: TAMMI SUE MARQUIS |
| Owner: JM PROPERTIES X LLC |
|
Address 29 COLUMBUS COURT PALM COAST, FL 32137 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
GULFSTREAM HOMES & CONSTRUCTION, LLC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1092 BUNNELL, FL 32110 |
CRC1326418 (Exp: 08/31/2026) | (386)437-1508 | 386-437-9769 |
Sub Contractors
JAMES CRAIG FISHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 451 BUNNELL, FL 32110 |
CAC1819807 (Exp: 08/31/2026) | 386-222-9549 |
ARTHUR J PASCOE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 730007 ORMOND BEACH, FL 32174 |
EC13007168 (Exp: 08/31/2026) | 386-547-6439 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/28/2020 | FINAL APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION At the time of my Inspection workers still laying tile and painting, Majority of outlet covers were off and laying on the floor. To many obstacles and people to maneuver around to perform Inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 07/24/2020 | FINAL APPROVED | JHARDING |
| Note: Approved. | |||
| BLD - BUILDING FINAL | 07/24/2020 | Disapproved - NO FEE | FWILLIS |
| Note: At the time of my Inspection workers still laying tile and painting, Majority of outlet covers were off and laying on the floor. To many obstacles and people to maneuver around to perform Inspection. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 07/23/2020 | APPROVED | KHOWELL |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/23/2020 | APPROVED | KHOWELL |
| ROW - STORMWATER FINAL | 07/23/2020 | FINAL APPROVED | KHOWELL |
| ROW - FINAL APRON (AFTER POUR) | 07/23/2020 | APPROVED | KHOWELL |
| FINAL SURVEY (OFFICE USE ONLY) | 07/15/2020 | Disapproved - NO FEE | KHOWELL |
| Note: VERIFY OUTSIDE GRADE ELEVATION AT THE FOUNDATION REQUIRED TO BE A MINIMUM 4" FOR BLOCK CONSTRUCTION AND 6" FOR WOOD FRAME CONSTRUCTION PER FLORIDA BUILDING CODE CHAPTER 4 R404.1.6 | |||
| ELECTRIC - EARLY POWER | 06/18/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 9:50 | |||
| ROW- PRE-APRON (PRE-POUR) | 06/17/2020 | APPROVED - AS NOTED | KHOWELL |
| ROW- PRE-APRON (PRE-POUR) | 06/16/2020 | Disapproved - NO FEE | KHOWELL |
| Note: COULD NOT LOCATE BENCH MARK IN THE INTERSECTION AND HOLE FOR PROPERTY LINE NAIL AND DISK THE HOLE IS NOT BIG ENOUGH TO PUT ROD IN. ENDS OF PIPE DAMAGED / BENT NEED TO BE STRAIGHTENED OUT. 4" MINIMUM THICK CONCRETE IS REQUIRED ABOVE THE ROW SOME AREAS NEED TO BECXUT DOWN | |||
| U - SEWER TIE IN | 06/09/2020 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION P-2503.2 CONCEALMENT NEED TO UNCOVER CONNECTION AT PEP TANK AREA | |||
| GRAVITY SEWER TEST | 06/09/2020 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION P-2503.2 CONCEALMENT . NEED TO UNCOVER PIPE | |||
| GRAVITY SEWER TEST | 06/08/2020 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: P-2503.2 CONCEALMENT . NEED TO UNCOVER PIPE | |||
| U - SEWER TIE IN | 06/08/2020 | Disapproved - NO FEE | JGIBSON |
| Note: P-2503.2 CONCEALMENT NEED TO UNCOVER CONNECTION AT PEP TANK AREA | |||
| U - SEWER TIE IN | 05/27/2020 | CANCELLED BY APPLICANT | WEB |
| GRAVITY SEWER TEST | 05/27/2020 | CANCELLED BY APPLICANT | WEB |
| PEP TANK INSTALLATION REQUEST | 05/13/2020 | APPROVED | CSTONE |
| LATH/BRICK/ WATER BARRIER | 05/06/2020 | APPROVED | FWILLIS |
| INSULATION | 04/27/2020 | APPROVED | FWILLIS |
| ALL ROUGH | 04/22/2020 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 04/13/2020 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/06/2020 | APPROVED - AS NOTED | FWILLIS |
| Note: Truss Pullout Needs to be stamped by Engineer since it has the new layout. Inspect on next Inspection. | |||
| TIE BEAM / LINTEL | 03/18/2020 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 03/05/2020 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 02/27/2020 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 02/24/2020 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 02/05/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | HOLD | 07/17/2020 | 07/17/2020 |
| Note: Held By: JMONTARULI The Termite Certificate is for a different address | |||
| BADMIN | COMPLETE | 07/17/2020 | 07/17/2020 |
| Note: Released By: JMONTARULI | |||
| ENGIN1 | COMPLETE | 03/04/2020 | 03/05/2020 |
| Note: Released By: TBAKER | |||
| BLD | COMPLETE | 01/27/2020 | 01/27/2020 |
| Note: Released By: JPI | |||
| ZON | COMPLETE | 01/16/2020 | 01/16/2020 |
| Note: Released By: ELENS | |||
| BLD | HOLD | 01/16/2020 | 01/17/2020 |
| Note: Held By: JPI 1. Comments still not addressed on floor plan. Sending review back to the Palm Coast Building Department and requested that a Palm Coast employee finish the review. | |||
| UD1 | COMPLETE | 01/10/2020 | 01/14/2020 |
| Note: Released By: AHALL | |||
| ENGIN1 | COMPLETE | 01/10/2020 | 01/13/2020 |
| Note: Released By: TBAKER | |||
| ZON | HOLD | 01/10/2020 | 01/10/2020 |
| Note: Held By: ELENS Eight foundation plantings are required in front of the house. | |||
| ELEC | COMPLETE | 01/10/2020 | 01/13/2020 |
| Note: Released By: JMUNSON | |||
| BLD | HOLD | 01/10/2020 | 01/13/2020 |
| Note: Held By: JPI 1. Repeating comments. We reviewed the file directory and did not see the revised floor plan. Please resubmit. Here are the repeating comments. 2. Please add the label for a Vacuum Breaker on the hose bib. (R2902.4) 3. Garage door entrance. R302.5.1 Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. Please label the door option. 4. Provide safety device at water heater (tap and thermal expansion device). Add note. P607.3 5. Add label with note at garage walls. R302.5.2 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage. | |||
| SW1 | COMPLETE | 01/10/2020 | 01/10/2020 |
| Note: Released By: CTROHA | |||
| SWALE | COMPLETE | 01/02/2020 | 01/27/2020 |
| Note: Released By: TBAKER | |||
| BLD | HOLD | 12/20/2019 | 12/28/2019 |
| Note: Held By: JPI 1. Please add the label for a Vacuum Breaker on the hose bib. (R2902.4) 2. Garage door entrance. R302.5.1 Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. Please label the door option. 3. Provide safety device at water heater (tap and thermal expansion device). Add note. P607.3 4. Add label with note at garage walls. R302.5.2 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage. | |||
| CUSVC | COMPLETE | 12/20/2019 | 12/20/2019 |
| Note: Released By: HHAND | |||
| ELEC | HOLD | 12/20/2019 | 12/23/2019 |
| Note: Held By: JMUNSON Need outlets by bathroom sinks. NEC 2014 art 210.52 (D) | |||
| ENGIN1 | COMPLETE | 12/20/2019 | 01/02/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 12/20/2019 | 12/23/2019 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 12/20/2019 | 12/20/2019 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 12/20/2019 | 12/28/2019 |
| Note: Released By: JPI | |||
| SW1 | HOLD | 12/20/2019 | 12/30/2019 |
| Note: Held By: CTROHA Applicant needs to provide FFE for improved adjacent lots | |||
| UD1 | COMPLETE | 12/20/2019 | 12/27/2019 |
| Note: Released By: LFITZGERALD | |||
| ZON | HOLD | 12/20/2019 | 12/20/2019 |
| Note: Held By: TDOAK 1. Site plan/survey must show total square footage of lot. 2. Site plan/survey has incorrect legal description (section #). 3. Site plan/survey must show width of proposed driveway and front walkway. 4. Site plan/survey must show A/C pad with dimensions. 5. Landscape plan must show 5 trees. 6. Landscape plan must have a minimum of 4 foundation plantings on right side (the 7 gallon shrubs for screening the mechanical equipment do not count towards this number) and a minimum of 6 foundation plantings on the street side. 7. Exterior house color is blue and does not meet the LDC definition of an earth tone or a pastel. 8. Elevation page must have sides of home labeled as right and left. 9. Banding is required around all windows and doors facing the public right-of-way. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/03/2020 |
| CONTRACTOR CHANGE | ¤40.00 | 02/25/2020 |
| ELECTRIC FEE | ¤197.40 | 01/28/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 01/28/2020 |
| IMPACT FEE FIRE | ¤223.38 | 01/28/2020 |
| IMPACT FEE PARKS | ¤849.24 | 01/28/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/28/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,632.00 | 01/28/2020 |
| MECHANICAL FEE | ¤197.40 | 01/28/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/28/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 01/28/2020 |
| PLAN CHECK FEE | ¤91.60 | 01/28/2020 |
| PLUMBING FEE | ¤197.40 | 01/28/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤458.00 | 01/28/2020 |
| SITE PLAN 20 | ¤20.00 | 01/28/2020 |
| SURCHARGE FS 533.721 | ¤10.90 | 01/28/2020 |
| SURCHARGE - FS 468.631 | ¤16.35 | 01/28/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/28/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤48.96) | 01/28/2020 |
| SEWER CREDIT | (¤1,147.00) | 01/28/2020 |
| SEWER INSPECTION | ¤25.00 | 01/28/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 01/28/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 01/28/2020 |
| METER - DEPOSIT | ¤60.00 | 01/28/2020 |
| WATER- TURN ON | ¤25.00 | 01/28/2020 |
| ADMIN FEE | ¤20.00 | 01/28/2020 |
| CONNECTION FEES | ¤1,002.88 | 01/28/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,553.66 |