I want to search for...
Permit #2019120820
Permit Details
Status: COED
| Parcel Id: 07-11-31-7027-00071-0090 |
| CONDITIONED SPACE: 1779 sqft |
| GARAGE: 451 sqft |
| OPENED PORCH (WITH ROOF) : 110 sqft |
| OPENED PORCH (WITH ROOF) : 40 sqft |
| Total Square Footage: 2380 sqft |
| Block: 00071 |
| Subdivision: 2128 - SECTION 27-WYNNFIELD |
| Job Phone: 407-807-0656 |
| Location Address: 69 WOODSIDE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/17/2020 |
| NOC: RECORDED |
| Applicant name: NAVIN SUGRIM |
| Owner: DLP BRITE HOMES LLC |
|
Address 605 PALENCIA CLUB DRIVE ST AUGUSTINE, FL 32095 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤129,200.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
DLP BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
7345 GREENBRIAR PKWY ORLANDO, FL 32819 |
CBC1263567 (Exp: 08/31/2022) | 407-807-0656 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ROBERT G DELLO RUSSO
| Status | Location Address | State License Number | Phone | Fax |
| DECEASED |
531 CODISCO WAY SANFORD, FL 32771 |
CAC032448 (Exp: 08/31/2022) | (407)831-2665 | (407)333-3853 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/08/2020 | FINAL APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION GUEST BATH EXHAUST NOT WORKING CORRECTLY | |||
| ROW - FINAL INSPECTION | 07/07/2020 | CANCELLED BY INSPECTOR | RGROSS |
| Note: BUILDER ALREADY HAS A ROW FINAL APPROVAL. SEE FINAL STORMWATER. | |||
| U -UTILITY RESIDENTIAL FINAL | 07/06/2020 | APPROVED | AHALL |
| BLD - BUILDING FINAL | 07/06/2020 | Disapproved - NO FEE | JCOLASANTI |
| Note: GUEST BATH EXHAUST NOT WORKING CORRECTLY | |||
| ROW - STORMWATER FINAL | 07/02/2020 | APPROVED | RGROSS |
| ROW - FINAL APRON (AFTER POUR) | 07/02/2020 | APPROVED | RGROSS |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/01/2020 | APPROVED | RGROSS |
| Note: SEE NOTES ON FINAL SURVEY APPROVAL | |||
| FINAL SURVEY (OFFICE USE ONLY) | 07/01/2020 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION FINISHED FLOOR ELEVATION MUST BE A MINIMUM OF 4 INCHES ABOVE THE OUTSIDE GRADE AT THE FOUNDATION. COMPARE FFE TO EACH CORNER OF THE HOUSE OUTSIDE GRADE. 7/1/20 - DRAINAGE CONVEYANCE ON THE FRONT RIGHT SIDE FLOW INSIDE THE PROPERTY LINE AROUND THE WATER METER. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/26/2020 | Disapproved - NO FEE | RGROSS |
| Note: FINISHED FLOOR ELEVATION MUST BE A MINIMUM OF 4 INCHES ABOVE THE OUTSIDE GRADE AT THE FOUNDATION. COMPARE FFE TO EACH CORNER OF THE HOUSE OUTSIDE GRADE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/26/2020 | CANCELLED BY INSPECTOR | RGROSS |
| Note: FINAL SURVEY MUST BE APPROVED FIRST. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/03/2020 | APPROVED - AS NOTED | RGROSS |
| Note: READY TO POUR AT THE TIME OF THE INSPECTION. NOTE THAT HEAVY RAIN IS IN THE FORECAST. BUILDER SHOULD DOUBLE CULVERT ELEVATIONS BEFORE POURING. | |||
| ELECTRIC - EARLY POWER | 06/01/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 11:00 | |||
| GRAVITY SEWER TEST | 05/13/2020 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 05/13/2020 | APPROVED | JGIBSON |
| LATH/BRICK/ WATER BARRIER | 04/30/2020 | APPROVED | JCOLASANTI |
| INSULATION | 04/28/2020 | APPROVED | JCOLASANTI |
| ALL ROUGH | 04/22/2020 | APPROVED - AS NOTED | JCOLASANTI |
| Note: need to install junction box at garage conduit for exterior lights (cannot use foam to cover conductors) | |||
| ROOF VALLEY & METAL | 04/13/2020 | APPROVED | JCOLASANTI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/07/2020 | APPROVED - AS NOTED | JCOLASANTI |
| Note: truss R41 needs straps....truss J15 needs block for strap...two truss on garage side bearing wall need to be straped | |||
| ELECTRIC-TUG | 04/01/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 11:45 | |||
| TIE BEAM / LINTEL | 03/23/2020 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 03/16/2020 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 03/13/2020 | APPROVED | JCOLASANTI |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/11/2020 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 02/19/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 03/16/2020 | 03/16/2020 |
| Note: Released By: TBAKER Foundation Survey | |||
| BLD | COMPLETE | 01/21/2020 | 01/25/2020 |
| Note: Released By: JPI building plan previously released by FREODICA | |||
| ZON | COMPLETE | 01/21/2020 | 01/23/2020 |
| Note: Released By: AMOBLEY | |||
| SW1 | COMPLETE | 01/21/2020 | 01/23/2020 |
| Note: Released By: CTROHA | |||
| BLD | COMPLETE | 01/10/2020 | 01/10/2020 |
| Note: Released By: FREODICA | |||
| SWALE | COMPLETE | 01/03/2020 | 02/04/2020 |
| Note: Released By: TBAKER | |||
| BLD | HOLD | 12/27/2019 | 12/31/2019 |
| Note: Held By: JPI 1. Please add the label for a Vacuum Breaker on the hose bib. (R2902.4) 2. Provide safety device at water heater (tap and thermal expansion device). Add note. P607.3 | |||
| CUSVC | COMPLETE | 12/27/2019 | 12/27/2019 |
| Note: Released By: AROSCOE | |||
| ELEC | COMPLETE | 12/27/2019 | 12/27/2019 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 12/27/2019 | 01/03/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 12/27/2019 | 01/02/2020 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 12/27/2019 | 12/30/2019 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 12/27/2019 | 12/31/2019 |
| Note: Released By: JPI | |||
| SW1 | HOLD | 12/27/2019 | 12/30/2019 |
| Note: Held By: CTROHA Applicant needs to show proposed elevations on a 20' grid also show proposed drainage elevations. Applicant must match existing elevations at the property line of improved lots and show proposed drainage conveyance inside the property line. Applicant needs to provide final sod elevations at all four corners of the foundation | |||
| UD1 | COMPLETE | 12/27/2019 | 01/03/2020 |
| Note: Released By: AHALL | |||
| ZON | HOLD | 12/27/2019 | 12/27/2019 |
| Note: Held By: TDOAK 1. Site plan must note width and material of proposed front walkway. 2. All platted easements must be labeled on survey and site plan. 3. This lot is 12000 sq ft and therefore requires 5 trees. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 06/02/2020 |
| ELECTRIC FEE | ¤193.20 | 02/17/2020 |
| MECHANICAL FEE | ¤193.20 | 02/17/2020 |
| PLAN CHECK FEE | ¤88.80 | 02/17/2020 |
| PLUMBING FEE | ¤193.20 | 02/17/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤444.00 | 02/17/2020 |
| SITE PLAN 20 | ¤20.00 | 02/17/2020 |
| SURCHARGE FS 533.721 | ¤10.64 | 02/17/2020 |
| SURCHARGE - FS 468.631 | ¤15.95 | 02/17/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/17/2020 |
| ADMIN FEE | ¤20.00 | 02/17/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤1,298.99 |