I want to search for...
Permit #2020010264
Permit Details
Status: FINAL
| Parcel Id: 33-11-31-3061-00040-0030 |
| Block: 00040 |
| Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA |
| Job Phone: 407-688-0786 |
| Location Address: 34 NEW WATER OAK DR |
| Type: AL - ALUMINUM SCREEN STRUCTURE |
| Issue Date: 02/06/2020 |
| NOC: RECORDED |
| Applicant name: KEITH THOMAS JONES |
| Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC |
|
Address 131 CHADWICK DRIVE DAVENPORT, FL 33837 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤6,425.00 |
| Job Description: SCREEN ENCLOSURE |
| Type: CN |
Contractor
SUNSHINE SCREEN ENCLOSURES INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4100 MAVERICK CT SANFORD, FL 32771 |
SCC131149881 (Exp: 08/31/2026) | 407-688-0786 | 407-302-0851 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL - BUILDING MISC | 04/21/2020 | FINAL APPROVED | FWILLIS |
| FINAL - BUILDING MISC | 04/21/2020 | FINAL APPROVED | FWILLIS |
Review History
| Department | Status | Date In | Date Out |
| BLD | HOLD | 02/05/2020 | 02/05/2020 |
| Note: Held By: PBUCKLEY PER CONTRACTOR NO GLASS IN ENCLOSURE. ALL COMMENTS RELATED TO TEMPERED GLASS HAVE BEEN REMOVED. PLEASE REVISE PLANS ACCORDING TO THE COMMENTS BELOW. 1. Screen plans indicate the presence of an in-swing door. Doors from pool enclosures must swing out from the enclosure. Please have engineer change note to reflect out swinging door. 2. Screen plans indicate door to be less than the required 6 feet 8 inches (80 inches). Revise plans to reflect a code compliant door. 3. On site plan show location of door(s) from pool enclosure. Indicate swing of door (out). Indicate a self--latching device will be provided on pool side of door at least 54 inches above door thresh hold. Indicate door will be provided with self closing device. 4. On site plan show door, if any, from existing lanai into pool enclosure. Indicate door does have or will be provided with a self latching device mounted on the pool side a minimum of 54 inches above e the door thresh hold. Indicate the door does have or will be provided with a self closing device. Above comments per Florida Building Code Residential Chapter 45 6th Edition. 5. Site plan appears to indicate pool enclosure will be attached to existing wall and across components of the hot tub / spa. Enclosure plans do not include attachment details for the wall or spa area. Please provide attachment details by the engineer of record for these areas. | |||
| BLD | COMPLETE | 02/05/2020 | 02/05/2020 |
| Note: Released By: PBUCKLEY Approved after discussion with the contractor. | |||
| BLD | HOLD | 01/09/2020 | 01/24/2020 |
| Note: Held By: PBUCKLEY 1. Screen plans indicate the presence of an in-swing door. Doors from pool enclosures must swing out from the enclosure. Please have engineer change note to reflect out swinging door. 2. Screen plans indicate door to be less than the required 6 feet 8 inches (80 inches). Revise plans to reflect a code compliant door. 3. On site plan show location of door(s) from pool enclosure. Indicate swing of door (out). Indicate a self--latching device will be provided on pool side of door at least 54 inches above door thresh hold. Indicate door will be provided with self closing device. 4. On site plan show door, if any, from existing lanai into pool enclosure. Indicate door does have or will be provided with a self latching device mounted on the pool side a minimum of 54 inches above e the door thresh hold. Indicate the door does have or will be provided with a self closing device. Above comments per Florida Building Code Residential Chapter 45 6th Edition. 5. Pool enclosure plans indicate the use of glass in the pool enclosure. Glass in pool enclosures and within 60 inches of pool surface must meet certain design criteria. It appears some areas of the enclosure are less than 60 inches to the edge of pool. Please clarify; if enclosure walls are 60 inches or more from the edge of pool in all locations. If not 60 inches or more, then provide notes indicating glazing compliance with Section R308.4.5 and Table R308.3.1(1) or R308.3.1(2). 6. Glass in enclosure walls adjacent to doors must meet certain design criteria per Section R308.4.2 regardless of distance to edge of pool. PLease provide notes indicating compliance with Section R308.4.2 and Table R308.3.1(1) or R308.3.1(2). 7. Glass in enclosure door must meet specific design requirements per Section R308.4.1 regardless of distance to edge of pool. PLease provide notes indicating compliance with Section R308.4.2 and Table R308.3.1(1) or R308.3.1(2). 8. Site plan appears to indicate pool enclosure will be attached to existing wall and across components of the hot tub / spa. Enclosure plans do not include attachment details for the wall or spa area. Please provide attachment details by the engineer of rec rod for these areas. Comments No. 5 through 8 per the Florida Building Code-Residential 6th Edition | |||
| ZON | COMPLETE | 01/09/2020 | 01/10/2020 |
| Note: Released By: AMOBLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 02/06/2020 |
| INSPECTION 40 | ¤40.00 | 02/06/2020 |
| PLAN CHECK FEE | ¤40.00 | 02/06/2020 |
| SITE PLAN 20 | ¤20.00 | 02/06/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 02/06/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 02/06/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤124.00 |