I want to search for...

Permit #2020010264

Permit Details

Status: FINAL

Parcel Id: 33-11-31-3061-00040-0030
Block: 00040
Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA
Job Phone: 407-688-0786
Location Address: 34 NEW WATER OAK DR
Type: AL - ALUMINUM SCREEN STRUCTURE
Issue Date: 02/06/2020
NOC: RECORDED
Applicant name: KEITH THOMAS JONES
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0030
Contracted Stated Job Value: ¤6,425.00
Job Description: SCREEN ENCLOSURE
Type: CN

Contractor

SUNSHINE SCREEN ENCLOSURES INC
Status Location Address State License Number Phone Fax
ACTIVE

4100 MAVERICK CT

SANFORD, FL 32771

SCC131149881 (Exp: 08/31/2026) 407-688-0786 407-302-0851

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 04/21/2020 FINAL APPROVED FWILLIS
FINAL - BUILDING MISC 04/21/2020 FINAL APPROVED FWILLIS

Review History

Department Status Date In Date Out
BLD HOLD 02/05/2020 02/05/2020
Note: Held By: PBUCKLEY PER CONTRACTOR NO GLASS IN ENCLOSURE. ALL COMMENTS RELATED TO TEMPERED GLASS HAVE BEEN REMOVED. PLEASE REVISE PLANS ACCORDING TO THE COMMENTS BELOW. 1. Screen plans indicate the presence of an in-swing door. Doors from pool enclosures must swing out from the enclosure. Please have engineer change note to reflect out swinging door. 2. Screen plans indicate door to be less than the required 6 feet 8 inches (80 inches). Revise plans to reflect a code compliant door. 3. On site plan show location of door(s) from pool enclosure. Indicate swing of door (out). Indicate a self--latching device will be provided on pool side of door at least 54 inches above door thresh hold. Indicate door will be provided with self closing device. 4. On site plan show door, if any, from existing lanai into pool enclosure. Indicate door does have or will be provided with a self latching device mounted on the pool side a minimum of 54 inches above e the door thresh hold. Indicate the door does have or will be provided with a self closing device. Above comments per Florida Building Code Residential Chapter 45 6th Edition. 5. Site plan appears to indicate pool enclosure will be attached to existing wall and across components of the hot tub / spa. Enclosure plans do not include attachment details for the wall or spa area. Please provide attachment details by the engineer of record for these areas.
BLD COMPLETE 02/05/2020 02/05/2020
Note: Released By: PBUCKLEY Approved after discussion with the contractor.
BLD HOLD 01/09/2020 01/24/2020
Note: Held By: PBUCKLEY 1. Screen plans indicate the presence of an in-swing door. Doors from pool enclosures must swing out from the enclosure. Please have engineer change note to reflect out swinging door. 2. Screen plans indicate door to be less than the required 6 feet 8 inches (80 inches). Revise plans to reflect a code compliant door. 3. On site plan show location of door(s) from pool enclosure. Indicate swing of door (out). Indicate a self--latching device will be provided on pool side of door at least 54 inches above door thresh hold. Indicate door will be provided with self closing device. 4. On site plan show door, if any, from existing lanai into pool enclosure. Indicate door does have or will be provided with a self latching device mounted on the pool side a minimum of 54 inches above e the door thresh hold. Indicate the door does have or will be provided with a self closing device. Above comments per Florida Building Code Residential Chapter 45 6th Edition. 5. Pool enclosure plans indicate the use of glass in the pool enclosure. Glass in pool enclosures and within 60 inches of pool surface must meet certain design criteria. It appears some areas of the enclosure are less than 60 inches to the edge of pool. Please clarify; if enclosure walls are 60 inches or more from the edge of pool in all locations. If not 60 inches or more, then provide notes indicating glazing compliance with Section R308.4.5 and Table R308.3.1(1) or R308.3.1(2). 6. Glass in enclosure walls adjacent to doors must meet certain design criteria per Section R308.4.2 regardless of distance to edge of pool. PLease provide notes indicating compliance with Section R308.4.2 and Table R308.3.1(1) or R308.3.1(2). 7. Glass in enclosure door must meet specific design requirements per Section R308.4.1 regardless of distance to edge of pool. PLease provide notes indicating compliance with Section R308.4.2 and Table R308.3.1(1) or R308.3.1(2). 8. Site plan appears to indicate pool enclosure will be attached to existing wall and across components of the hot tub / spa. Enclosure plans do not include attachment details for the wall or spa area. Please provide attachment details by the engineer of rec rod for these areas. Comments No. 5 through 8 per the Florida Building Code-Residential 6th Edition
ZON COMPLETE 01/09/2020 01/10/2020
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 02/06/2020
INSPECTION 40 ¤40.00 02/06/2020
PLAN CHECK FEE ¤40.00 02/06/2020
SITE PLAN 20 ¤20.00 02/06/2020
SURCHARGE FS 533.721 ¤2.00 02/06/2020
SURCHARGE - FS 468.631 ¤2.00 02/06/2020
Fees Total Due: ¤0.00 Total Paid: ¤124.00