Permit #2020010609
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00080-0060 |
| CONDITIONED SPACE: 1406 sqft |
| GARAGE: 395 sqft |
| OPENED PORCH (WITH ROOF) : 99 sqft |
| OPENED PORCH (WITH ROOF) : 44 sqft |
| Total Square Footage: 1944 sqft |
| Block: 00080 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 904-667-3599 |
| Location Address: 40 PINELYNN DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/27/2020 |
| NOC: RECORDED |
| Applicant name: TONY S JACKSON |
| Owner: 3DRE LLC |
|
Address APT 1104 JACKSONVILLE, FL 32224 |
|
Address 3544 ST JOHNS BLUFF RD S JACKSONVILLE, FL 32224 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤90,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
T-DAWG CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
6821 SOUTH POINT DR N NEPTUNE , FL 32266 |
CGC1523419 (Exp: 08/31/2024) | 904-667-3599 |
Sub Contractors
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
MAXIM BUDNIK
| Status | Location Address | State License Number |
| ACTIVE |
3 WAVECREST PL PALM COAST, FL 32164 |
CAC1818445 (Exp: 08/31/2026) |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING FINAL | 11/23/2020 | Approval - Private Provider | PPROVIDER |
| HVAC FINAL | 11/23/2020 | Approval - Private Provider | PPROVIDER |
| ELECTRIC FINAL | 11/23/2020 | Approval - Private Provider | PPROVIDER |
| BLD - BUILDING FINAL | 11/23/2020 | Approval - Private Provider | PPROVIDER |
| U -UTILITY RESIDENTIAL FINAL | 11/20/2020 | Disapproved - NO FEE | LFITZGERALD |
| Note: inspecrtor needs access to garage to inspect that the cor rect cicuit braker is being used please call me at 386-214-3376.The number on the permit does not work. | |||
| U -UTILITY RESIDENTIAL FINAL | 11/20/2020 | FINAL APPROVED | LFITZGERALD |
| Note: THIS IS A REINSPECTION-access was provided once i found a phone number to call,the 1 on the permit does not work inspecrtor needs access to garage to inspect that the cor rect cicuit braker is being used please call me at 386-214-3376.The number on the permit does not work. | |||
| ROW - STORMWATER FINAL | 11/19/2020 | APPROVED - AS NOTED | GBERTOLA |
| Note: THIS IS A REINSPECTION RIGTH SIDE SWALE IS HIGHER, WATER CAN'T MOVE OUT FROM 23.48 TO 23.78 The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 feet and must demonstrate positive fall in the direction described in the swale plan. NEED TO LOWER THE RIGTH I WILL LOWER AT LEAST 1/10 11/19/2020=CORRECTION MADE IT | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/19/2020 | APPROVED - AS NOTED | GBERTOLA |
| Note: THIS IS A REINSPECTION RIGTH SIDE SWALE IS HIGHER, WATER CAN'T MOVE OUT FROM 23.48 TO 23.78 The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 feet and must demonstrate positive fall in the direction described in the swale plan. NEED TO LOWER THE RIGTH I WILL LOWER AT LEAST 1/10 11/19/2020=CORRECTION MADE IT | |||
| ROW - STORMWATER FINAL | 11/18/2020 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: RIGTH SIDE SWALE IS HIGHER, WATER CAN'T MOVE OUT FROM 23.48 TO 23.78 The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 feet and must demonstrate positive fall in the direction described in the swale plan. NEED TO LOWER THE RIGTH I WILL LOWER AT LEAST 1/10 | |||
| ROW - FINAL APRON (AFTER POUR) | 11/18/2020 | APPROVED | GBERTOLA |
| Note: THIS IS A REINSPECTION Please inspect after 9:00 am if possible Thank you I CAN'T APPROVE FINAL APRON, YOU NEED TO REQUEST FIRST FINAL SURVEY FIRST AFTER THAT AFTER POUR, ROW FINAL | |||
| U-CROSS CONNECTION | 11/18/2020 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-rsidence being sprinkled | |||
| FINAL SURVEY (OFFICE USE ONLY) | 11/18/2020 | APPROVED - AS NOTED | GBERTOLA |
| Note: RIGTH SIDE SWALE IS HIGHER, WATER CAN'T MOVE OUT FROM 23.48 TO 23.78 The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 feet and must demonstrate positive fall in the direction described in the swale plan. NEED TO LOWER THE RIGTH I WILL LOWER AT LEAST 1/10 | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/18/2020 | Disapproved - NO FEE | GBERTOLA |
| Note: RIGTH SIDE SWALE IS HIGHER, WATER CAN'T MOVE OUT FROM 23.48 TO 23.78 The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus 0.10 feet and must demonstrate positive fall in the direction described in the swale plan. NEED TO LOWER THE RIGTH I WILL LOWER AT LEAST 1/10 | |||
| ROW - FINAL APRON (AFTER POUR) | 11/10/2020 | Disapproved - NO FEE | GBERTOLA |
| Note: Please inspect after 9:00 am if possible Thank you I CAN'T APPROVE FINAL APRON, YOU NEED TO REQUEST FIRST FINAL SURVEY FIRST AFTER THAT AFTER POUR, ROW FINAL | |||
| ROW - FINAL APRON (AFTER POUR) | 11/09/2020 | Disapproved - NO FEE | GBERTOLA |
| Note: THIS IS A REINSPECTION CHECK FOR DIRT AND SOD. COMPACTED DIRT AND SOD MUST BE PLACED AROUND ALL EDGES OF THE POURED CONCRETE INCLUDING THE DRIVEWAY SHOULDERS TO PREVENT WASHOUT THE CONCRETE AT THE END OF THE FOOTER ON THE LEFT SIDE IS HIGHER THEN THE INVERT OF THE CULVERT PIPE NEED TO GRIND IT DOWN REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT. PLEASE RESCHEDULE WHEN THE DRIVEWAY IS CLEAR A LOT BAG ON TOP OF THE DRIVAWAY | |||
| ROW - FINAL APRON (AFTER POUR) | 10/27/2020 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: CHECK FOR DIRT AND SOD. COMPACTED DIRT AND SOD MUST BE PLACED AROUND ALL EDGES OF THE POURED CONCRETE INCLUDING THE DRIVEWAY SHOULDERS TO PREVENT WASHOUT THE CONCRETE AT THE END OF THE FOOTER ON THE LEFT SIDE IS HIGHER THEN THE INVERT OF THE CULVERT PIPE NEED TO GRIND IT DOWN REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/15/2020 | APPROVED | GBERTOLA |
| Note: PLEASE IF A RAIN BEFORE POUR CONCRETE CHECK THE PIPE ELEVATION AGAIN | |||
| U - SEWER TIE IN | 10/07/2020 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION SEE SEWER NOTE | |||
| GRAVITY SEWER TEST | 10/07/2020 | APPROVED | JGIBSON |
| Note: THIS IS A REINSPECTION p-2503.4 NO TEST ON SEWER NEED TO TEST SEWER TO CLOSEST POINT OF CONNECTION TO SEWER TIE IN TO PEP TANK OR SEWER TAP | |||
| GRAVITY SEWER TEST | 10/06/2020 | Disapproved -FEE REQUIRED | JGIBSON |
| Note: p-2503.4 NO TEST ON SEWER NEED TO TEST SEWER TO CLOSEST POINT OF CONNECTION TO SEWER TIE IN TO PEP TANK OR SEWER TAP | |||
| U - SEWER TIE IN | 10/06/2020 | Disapproved - NO FEE | JGIBSON |
| Note: SEE SEWER NOTE | |||
| PEP TANK INSTALLATION REQUEST | 09/02/2020 | APPROVED | CSTONE |
| ELECTRIC - EARLY POWER | 08/26/2020 | Approval - Private Provider | PPROVIDER |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/05/2020 | Approval - Private Provider | PPROVIDER |
| INSULATION | 08/03/2020 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/29/2020 | Approval - Private Provider | PPROVIDER |
| PLUMBING 2ND ROUGH | 07/29/2020 | Approval - Private Provider | PPROVIDER |
| HVAC ROUGH | 07/29/2020 | Approval - Private Provider | PPROVIDER |
| ELECTRIC 2ND ROUGH | 07/29/2020 | Approval - Private Provider | PPROVIDER |
| FRAMING | 07/29/2020 | Approval - Private Provider | PPROVIDER |
| WALL SHEATHING | 07/29/2020 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 07/22/2020 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/20/2020 | Approval - Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 07/08/2020 | APPROVED | AMOBLEY |
| MONOLITHIC SLAB | 07/06/2020 | Approval - Private Provider | PPROVIDER |
| FOOTER | 07/06/2020 | CANCELLED BY INSPECTOR | NDIMATTINA |
| Note: From: Laura Jerrels <LJerrels@universalengineering.com> Sent: Thursday, November 19, 2020 10:03 AM To: Barbie Bembry <BBembry@palmcoastgov.com>; Building <BUILDINGDIVISION@PALMCOASTGOV.COM> Cc: Terry Larson <tdawgconstruction@gmail.com>; Mike Navarra <mnavarra@universalengineering.com> Subject: WO # 169508 REV., Mon-Slab, Permit # 2020-010609, Pass, ER, 7-6-20, 40 Pinelyn Drive, Palm Coast, Flagler, FL, TDAWG Construction Permit # 2020-010609, 40 Pinelyn Drive, Palm Coast: Back in July a Footing inspection was called in that should have been a mon-slab inspection and I was not told to change it in the system so it went out as the wrong thing. Attached is the Inspection Report for the Mono-slab. Sorry for any confusion. Thank you and have a good day! ? Laura Jerrels Inspections and Billing Administrator Daytona Beach Building Inspections Department 911 Beville Rd Ste 3 South Daytona , Fl 32119 p 386-756-1105 Ext 10409 | f 386-760-4067 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 07/02/2020 | Approval - Private Provider | PPROVIDER |
| WATER METER INSTALLATION REQUEST | 06/25/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 07/08/2020 | 07/08/2020 |
| Note: Released By: AMOBLEY | |||
| ENGIN1 | COMPLETE | 07/07/2020 | 07/08/2020 |
| Note: Released By: TBAKER Foundation Survey | |||
| ZON | HOLD | 07/07/2020 | 07/07/2020 |
| Note: Held By: AMOBLEY Foundation plan submitted is the approved proposed site plan not the existing foundation survey | |||
| MECH | COMPLETE | 02/14/2020 | 02/18/2020 |
| Note: Released By: CPISCITELLI | |||
| BLD | COMPLETE | 02/14/2020 | 02/18/2020 |
| Note: Released By: FREODICA | |||
| ZON | COMPLETE | 02/06/2020 | 02/06/2020 |
| Note: Released By: AMOBLEY | |||
| MECH | HOLD | 02/06/2020 | 02/06/2020 |
| Note: Held By: CPISCITELLI Energy Calc and EPL card need to be signed by the builder | |||
| BLD | HOLD | 02/06/2020 | 02/13/2020 |
| Note: Held By: FREODICA Previous hold comment item 2 need to be addressed. 2. Florida Product approval per FS 553.842: a. FL appproval number for garage door is still missing. b. Structural components FL 11506.4 for wood anchors can not be found on FL product approval listiing. FReodica -386-987-4734. | |||
| ZON | HOLD | 01/22/2020 | 01/22/2020 |
| Note: Held By: TDOAK Please completely fill out the color sheet. Provide garage door color, LRV's and materiel being used on home Please provide landscape plan showing required trees, foundation plantings, specific types and gallon sizes along with sod type and if irrigation will be installed. Is there no walkway from the garage to the front entry? If so, this must be indicated on the site plan and the landscape plan and must indicate material to be used and width. | |||
| SWALE | COMPLETE | 01/22/2020 | 02/13/2020 |
| Note: Released By: TBAKER | |||
| ZON | HOLD | 01/21/2020 | 01/22/2020 |
| Note: Held By: AMOBLEY Please completely fill out the color sheet. Provide garage door color, LRV's and materiel being used on home Please provide landscape plan showing required trees, foundation plantings, specific types and gallon sizes along with sod type and if irrigation will be installed | |||
| UD1 | COMPLETE | 01/21/2020 | 01/27/2020 |
| Note: Released By: AHALL | |||
| SW1 | COMPLETE | 01/21/2020 | 01/23/2020 |
| Note: Released By: CTROHA | |||
| PLUM | COMPLETE | 01/21/2020 | 01/30/2020 |
| Note: Released By: FREODICA | |||
| MECH | HOLD | 01/21/2020 | 01/23/2020 |
| Note: Held By: CPISCITELLI 1. EPL card does not match required insulation values for Prescriptive method. 2. Prescriptive method requires R38 insulation in ceiling. Calc and load shows R30 3. Ductwork for prescriptive method requires R8 insulation 4. Provide duct layout signed by AC contractor 5. Energy calc needs to be signed by builder | |||
| LOCATE | COMPLETE | 01/21/2020 | 01/23/2020 |
| Note: Released By: CSTONE | |||
| ENGIN1 | COMPLETE | 01/21/2020 | 01/22/2020 |
| Note: Released By: TBAKER | |||
| ELEC | COMPLETE | 01/21/2020 | 01/22/2020 |
| Note: Released By: JMUNSON | |||
| CUSVC | COMPLETE | 01/21/2020 | 01/27/2020 |
| Note: Released By: AROSCOE | |||
| BLD | HOLD | 01/21/2020 | 02/03/2020 |
| Note: Held By: FREODICA 1. Shhet S1.01- Foundation details: Foundation details 3, 4 and 5 shall have a minimum depth of 12 inches below the undesturbed ground surface per FBCR 6th ed. sec. R403.1.4. 2. Florida Product approval per FS 553.842: a. FL appproval number for garage door and soffits are missing. b. Structural components such as wood connectors, wood anchors and truss plates are missing. FReodica -386-987-4734. | |||
| BLD | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| CUSVC | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| ELEC | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| ENGIN1 | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| LOCATE | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| MECH | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| PLUM | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| SW1 | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| UD1 | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON builder request | |||
| ZON | HOLD | 01/17/2020 | 01/21/2020 |
| Note: Held By: JMUNSON |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 11/23/2020 |
| REINSPECTION FEE | ¤40.00 | 11/23/2020 |
| REINSPECTION FEE | ¤40.00 | 11/23/2020 |
| REINSPECTION FEE | ¤40.00 | 11/23/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤356.00 | 02/27/2020 |
| SITE PLAN 20 | ¤20.00 | 02/27/2020 |
| SURCHARGE FS 533.721 | ¤8.96 | 02/27/2020 |
| SURCHARGE - FS 468.631 | ¤13.45 | 02/27/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 02/27/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 02/27/2020 |
| SEWER CREDIT | (¤1,342.00) | 02/27/2020 |
| SEWER INSPECTION | ¤25.00 | 02/27/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 02/27/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 02/27/2020 |
| ELECTRIC FEE | ¤166.80 | 02/27/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 02/27/2020 |
| IMPACT FEE FIRE | ¤223.38 | 02/27/2020 |
| IMPACT FEE PARKS | ¤849.24 | 02/27/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 02/27/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 02/27/2020 |
| MECHANICAL FEE | ¤166.80 | 02/27/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/27/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 02/27/2020 |
| PLAN CHECK FEE | ¤71.20 | 02/27/2020 |
| PLUMBING FEE | ¤166.80 | 02/27/2020 |
| METER - DEPOSIT | ¤60.00 | 02/27/2020 |
| WATER- TURN ON | ¤25.00 | 02/27/2020 |
| ADMIN FEE | ¤20.00 | 02/27/2020 |
| CONNECTION FEES | ¤1,002.88 | 02/27/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,260.36 |