Permit #2020020190
Permit Details
Status: FINAL
| Parcel Id: 29-10-31-5540-00000-0310 |
| Block: 00000 |
| Subdivision: 1005 - SANCTUARY SUBDIVISION |
| Job Phone: 386-931-0764 |
| Location Address: 56 OLD OAK DR S |
| Type: DK - DOCK |
| Issue Date: 05/28/2020 |
| NOC: RECORDED |
| Applicant name: KEVIN A PECK |
| Owner: BRAYTON SALLY |
|
Address 144 COCHISE COURT PALM COAST, FL 32137 |
| Lot: 0310 |
| Contracted Stated Job Value: ¤100,000.00 |
| Job Description: DOCK & COQUINA RIP RAP BRIDGE |
| Type: CN |
Contractor
KEVIN A PECK, INC
| Status | Location Address | Phone |
| INACTIVE |
5845 WALNUT AVE BUNNELL, FL 32110 |
386-931-0764 |
Inspection History
| Type | Request Date | Result | Inspector |
| LDSC-LANDSCAPE/IRRIGATION FINAL | 10/22/2020 | APPROVED - AS NOTED | RGROSS |
| Note: ON SITE WITH RESIDENT. BUILDER TO RETURN WITH MORE COQUINA TO FILL SOME GAPS THAT HAVE DEVELOPED. | |||
| FINAL - BUILDING MISC | 10/21/2020 | FINAL APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION plans call for 2x6, collar ties 2x4 were used need revision or replace with 2 6 per plans | |||
| FINAL - BUILDING MISC | 10/19/2020 | Disapproved - NO FEE | WMILLER |
| Note: plans call for 2x6, collar ties 2x4 were used need revision or replace with 2 6 per plans |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 10/12/2020 | 10/12/2020 |
| Note: Released By: MDEFREITAS | |||
| BLD | COMPLETE | 10/12/2020 | 10/16/2020 |
| Note: Released By: PBUCKLEY | |||
| BADMIN | HOLD | 09/29/2020 | 09/29/2020 |
| Note: Held By: LMUSGROVE doc names and file names must match no numbers or names added - ex site plan = site plan | |||
| BLD | HOLD | 09/16/2020 | 09/23/2020 |
| Note: Held By: FREODICA Repeat comment for item 2: Revision: revised engineering drawing for bridge. 2. Provide verifiable, digital signature and seal of an engineer of record per FS 471.025 and FAC 61G15-23.005. FReodica - 386-986-4734 | |||
| BLD | HOLD | 08/19/2020 | 08/25/2020 |
| Note: Held By: FREODICA Revision: revised engineering drawing for bridge. 1. Identify the change(s) on revised plan with "clouded" symbol for clarity as it appears to be the same as the plan submitted on 5/28/20. 2. Provide verifiable, digital signature and seal of an engineer of record per FS 471.025 and FAC 61G15-23.005. FReodica - 386-986-4734 | |||
| BLD | COMPLETE | 05/18/2020 | 05/28/2020 |
| Note: Released By: PBUCKLEY | |||
| BLD | HOLD | 04/06/2020 | 04/15/2020 |
| Note: Held By: FREODICA Repeat comments: Held By: PBUCKLEY , 1. Provide additional design criteria for deck / dock floor live an ddead loads and boathouse roof live and dead loads per R301.1 2. Provide lumber species (grade appears to be identified) for rafters, beams, ridge board, stringers, hip rafters, joists/stringers and cross bucks per R502.3. 3. Provide roof structural panel type, grade and exposure type per R803.2.1 4. Provide note indicating roof structural panel fastening schedule and fastener specs are per R803.2.1 and table. 5. Plans indicate tile roof. Provide roof live load consistent for type of tile roof. Specify type of roofing tiles, underlayment, batten strips. 6. Provide notes indicating tile roofing and underlayment installation will be per Section R905.3. 7. Provide FLorida Product Approval Numbers and Roofing Worksheet for roofing underlyament and roof tiles. 8. Provide roofing contractor on application. 9. Provide manufacturer's specs for boat lift. Ensure attachments to support boat lift are per manufacturer's specs and design specs provided based on loads. FOR BRIDGE / DECK 9. Provide design criteria including dead load, live load and wind speed for bridge / deck. R301.1 10. Provide design criteria for guards at bridge / deck. R301.5 / Table R301.5 11. Provide lumber species and grade for 2"x6" decking between stringers. Provide information that lumber grade and species is capable of spanning width when installed "flat" based on applicable loads. R502.3 12. Indicate whether wood is to be preservative treated wood and if so what type. 13. Provide note indicating no opening in guard to capable of passing a 4 inch sphere or similar note per R3 . Bridge / deck appears to be more than 30 inches above ground below. R312.1.3 All refererences per the Florida Building Code Residential 6th Edition. | |||
| BLD | HOLD | 02/06/2020 | 02/13/2020 |
| Note: Held By: PBUCKLEY , 1. Provide additional design criteria for deck / dock floor live an ddead loads and boathouse roof live and dead loads per R301.1 2. Provide lumber species (grade appears to be identified) for rafters, beams, ridge board, stringers, hip rafters, joists/stringers and cross bucks per R502.3. 3. Provide roof structural panel type, grade and exposure type per R803.2.1 4. Provide note indicating roof structural panel fastening schedule and fastener specs are per R803.2.1 and table. 5. Plans indicate tile roof. Provide roof live load consistent for type of tile roof. Specify type of roofing tiles, underlayment, batten strips. 6. Provide notes indicating tile roofing and underlayment installation will be per Section R905.3. 7. Provide FLorida Product Approval Numbers and Roofing Worksheet for roofing underlyament and roof tiles. 8. Provide roofing contractor on application. 9. Provide manufacturer's specs for boat lift. Ensure attachments to support boat lift are per manufacturer's specs and design specs provided based on loads. FOR BRIDGE / DECK 9. Provide design criteria including dead load, live load and wind speed for bridge / deck. R301.1 10. Provide design criteria for guards at bridge / deck. R301.5 / Table R301.5 11. Provide lumber species and grade for 2"x6" decking between stringers. Provide information that lumber grade and species is capable of spanning width when installed "flat" based on applicable loads. R502.3 12. Indicate whether wood is to be preservative treated wood and if so what type. 13. Provide note indicating no opening in guard to capable of passing a 4 inch sphere or similar note per R3 . Bridge / deck appears to be more than 30 inches above ground below. R312.1.3 All refererences per the Florida Building Code Residential 6th Edition. | |||
| ZON | COMPLETE | 02/06/2020 | 02/06/2020 |
| Note: Released By: TDOAK Zoning review to be completed by City Environmental Planner. | |||
| PLENV | COMPLETE | 02/06/2020 | 02/06/2020 |
| Note: Released By: JMYERS Please be aware that there are Gopher Tortoises who inhabit the area. Should any construction fall within 25ft of a Gopher Tortoise burrow construction activities shall cease until the Gopher Tortoise has been relocated. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 05/28/2020 |
| PLAN CHECK FEE | ¤40.00 | 05/28/2020 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 05/28/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/28/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/28/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/28/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤184.00 |