I want to search for...

Permit #2020020441

Permit Details

Status: COED

Parcel Id: 07-11-31-7011-00030-0100
CONDITIONED SPACE: 1492 sqft
GARAGE: 459 sqft
OPENED PORCH (WITH ROOF) : 96 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
Total Square Footage: 2079 sqft
Block: 00030
Subdivision: 2193 - SECTION 11-BELLE TERRE
Job Phone: 386-627-8993
Location Address: 101 BERKSHIRE LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/18/2020
NOC: RECORDED
Applicant name: WILLIAM PIERCE STOUGHTON
Owner: LATORRE ELISABETH

Address

299 PINE STREET

ORMOND BEACH, FL 32174

Lot: 0100
Contracted Stated Job Value: ¤130,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

STOUGHTON & DURAN CUSTOM HOMES LLC
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1478

BUNNELL, FL 32110

CGC047560 (Exp: 08/31/2026) 386-627-8993 866-576-9888

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone
CANCEL

17 UNIMAY CT

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2022) 386-931-2568
RICHARD LEE VONBROCKEN
Status Location Address State License Number Phone Fax
INACTIVE

1738 STATE AVE

HOLLY HILL, FL 32117

CAC035516 (Exp: 08/31/2026) (386)672-1950 (386)672-1952
BRIAN CHRISTOPHER MULLEN
Status Location Address State License Number Phone
INACTIVE

PO BOX 351158

PALM COAST, FL 0

CCC1330417 (Exp: 08/31/2026) 386-385-8504
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/12/2021 FINAL APPROVED FWILLIS
U-CROSS CONNECTION 05/12/2021 APPROVED DHANEY
ROW - STORMWATER FINAL 05/12/2021 APPROVED - AS NOTED KRUTH
Note: New inspection due to canceled inspection there is a pallet of sod in the swale that needs to be removed and a pile of mulch in the back yard on the vacant property that will need to be removed Approved as noted that sod will be removed today 5/12/21 mulch is ok per home owner using it later and permission from lot owner for the storage
U -UTILITY RESIDENTIAL FINAL 05/12/2021 FINAL APPROVED DHANEY
U -UTILITY RESIDENTIAL FINAL 05/11/2021 CANCELLED BY APPLICANT WEB
U-CROSS CONNECTION 05/11/2021 CANCELLED BY APPLICANT WEB
ROW - STORMWATER FINAL 05/11/2021 CANCELLED BY APPLICANT WEB
Note: there is a pallet of sod in the swale that needs to be removed and a pile of mulch in the back yard on the vacant property that will need to be removed
ROW FIELD SURVEY /GRADING CERTIFICATION 05/07/2021 APPROVED KRUTH
ROW - FINAL APRON (AFTER POUR) 05/07/2021 APPROVED - AS NOTED KRUTH
Note: THIS IS A REINSPECTION needs sod then a final survey before the after pour and row stormwater final can be done corrections made
U-CROSS CONNECTION 05/07/2021 CANCELLED BY APPLICANT WEB
FINAL SURVEY (OFFICE USE ONLY) 05/07/2021 APPROVED KRUTH
ROW - FINAL APRON (AFTER POUR) 03/03/2021 Disapproved -FEE REQUIRED KRUTH
Note: needs sod then a final survey before the after pour and row stormwater final can be done
ROW- PRE-APRON (PRE-POUR) 03/01/2021 APPROVED - AS NOTED KRUTH
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION *TOO MUCH MATERIAL IN THE POUR AREA. MINIMUM 4 INCHES THROUGHOUT THE POUR BEYOND THE ROW. *MATERIAL ALL OVER NEEDS MORE COMPACTION. *CULVERT TO BE BURIED ONLY 50 % NOT 90 TO 95%. *NOT 4 INCHES THICK AT THE GARAGE AND PORCH ENTRANCE. *APRON SLOPE TOO STEEP MINIMUM IS 8%. Pipe is 5 tenths out of tolerance corrections made It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete.
ROW- PRE-APRON (PRE-POUR) 02/25/2021 Disapproved -FEE REQUIRED KRUTH
Note: THIS IS A REINSPECTION *TOO MUCH MATERIAL IN THE POUR AREA. MINIMUM 4 INCHES THROUGHOUT THE POUR BEYOND THE ROW. *MATERIAL ALL OVER NEEDS MORE COMPACTION. *CULVERT TO BE BURIED ONLY 50 % NOT 90 TO 95%. *NOT 4 INCHES THICK AT THE GARAGE AND PORCH ENTRANCE. *APRON SLOPE TOO STEEP MINIMUM IS 8%. Pipe is 5 tenths out of tolerance
ELECTRIC - EARLY POWER 02/23/2021 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 1:50
ELECTRIC - EARLY POWER 02/22/2021 Disapproved - NO FEE RMARTIN
Note: UN-USED OPENINGS IN GARAGE ELECTRIC PANEL, NEED BREAKER BLANKS NEC 110.12A
U - SEWER TIE IN 02/18/2021 APPROVED JGIBSON
GRAVITY SEWER TEST 02/17/2021 APPROVED - AS NOTED JGIBSON
Note: U-SEWER WILL BE CALLED IN TOMMOROW
ROW- PRE-APRON (PRE-POUR) 02/08/2021 Disapproved -FEE REQUIRED RGROSS
Note: *TOO MUCH MATERIAL IN THE POUR AREA. MINIMUM 4 INCHES THROUGHOUT THE POUR BEYOND THE ROW. *MATERIAL ALL OVER NEEDS MORE COMPACTION. *CULVERT TO BE BURIED ONLY 50 % NOT 90 TO 95%. *NOT 4 INCHES THICK AT THE GARAGE AND PORCH ENTRANCE. *APRON SLOPE TOO STEEP MINIMUM IS 8%.
ELECTRIC - EARLY POWER 01/08/2021 CANCELLED BY APPLICANT WEB
ELECTRIC-TUG 01/08/2021 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 10:10 am
LATH/BRICK/ WATER BARRIER 12/10/2020 APPROVED FWILLIS
INSULATION 12/08/2020 APPROVED FWILLIS
ALL ROUGH 12/04/2020 APPROVED - AS NOTED TSTAUFFACHER
Note: Tape vertical joints on vent pipes as discussed//check at insulation THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION Main Service Not connected. . Dryer Exhaust seams and connections, sealed…(6th edition) Need to seal dryer exhaust duct per FBC M, 1502.4.2 and 1601.4.1 Rafter tails on bump out not clipped
ALL ROUGH 12/03/2020 Disapproved -FEE REQUIRED TSTAUFFACHER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Main Service Not connected. . Dryer Exhaust seams and connections, sealed…(6th edition) Need to seal dryer exhaust duct per FBC M, 1502.4.2 and 1601.4.1 Rafter tails on bump out not clipped
ALL ROUGH 12/02/2020 Disapproved - NO FEE FWILLIS
Note: THIS IS A REINSPECTION Main Service Not connected.
ALL ROUGH 12/01/2020 Disapproved - NO FEE FWILLIS
Note: Main Service Not connected.
ALL ROUGH 11/17/2020 CANCELLED BY APPLICANT WEB
Note: THIS IS A REINSPECTION not ready
ALL ROUGH 11/16/2020 Disapproved - NO FEE JCOLASANTI
Note: not ready
ROOF VALLEY & METAL 10/30/2020 APPROVED JCOLASANTI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/27/2020 APPROVED - AS NOTED JCOLASANTI
Note: need MTS 12 rafters to top plate bump out at kithen
FOUND SURVEY APPROVED (OFFICE) 10/26/2020 APPROVED TBAKER
TIE BEAM / LINTEL 09/09/2020 APPROVED JCOLASANTI
MONOLITHIC SLAB 08/12/2020 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 08/04/2020 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 07/21/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN HOLD 05/10/2021 05/10/2021
Note: Held By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM you sending a revision saying Final no new final survey was submitted, but your final survey was approved on 5/6/21
BADMIN COMPLETE 05/10/2021 05/10/2021
Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM
ZON COMPLETE 10/23/2020 10/23/2020
Note: Released By: TDOAK
ENGIN1 COMPLETE 10/23/2020 10/26/2020
Note: Released By: TBAKER
ZON COMPLETE 10/22/2020 10/22/2020
Note: Released By: TDOAK
ENGIN1 COMPLETE 10/22/2020 10/23/2020
Note: Released By: TBAKER
ENGIN1 COMPLETE 10/21/2020 10/22/2020
Note: Released By: TBAKER
ZON HOLD 10/21/2020 10/21/2020
Note: Held By: TDOAK Foundation survey does not match approved site plan (the concrete in the front of the home is different than was approved). Please resubmit revised site plan to match foundation survey.
ZON COMPLETE 06/17/2020 06/18/2020
Note: Released By: AMOBLEY
BADMIN COMPLETE 06/17/2020 06/17/2020
Note: Released By: JMONTARULI
BADMIN HOLD 06/09/2020 06/09/2020
Note: Held By: STHOMAS 1. REMOVE '34 UPDATED' FROM ALL FILE NAMES 2. RENAME TO PLANS.PDF
BADMIN HOLD 06/09/2020 06/09/2020
Note: Held By: STHOMAS PLANS MUST BE UPLOADED INDIVIDUALLY. CAN NOT BE SINGLE PDF
ZON HOLD 05/22/2020 05/22/2020
Note: Held By: AMOBLEY No new plans submitted. Roofing worksheet shows a flat roof Per The LDC chapter 13 Section -13.03 All single family buildings shall have a pitched roof covereing a minimum of 65% of the overall floor area under roof Roof pitch must be at least a 5:12 and shall have an overhang beyond the building wall Flat roofed areas including, but not limited to, porches are permissible in the remaining 35% of floor area under roof.
MECH COMPLETE 05/22/2020 05/26/2020
Note: Released By: CPISCITELLI
BLD COMPLETE 05/22/2020 05/26/2020
Note: Released By: JPI
ZON HOLD 05/22/2020 05/22/2020
Note: Held By: TDOAK Repeat Comments 1. Per the LDC, "the corners of the home shall be wrapped with shrubbery or have an understory tree planted there." - See right front of home. 2. Two identical homes cannot be built within 4 lots of each other. This home is identical to the one you are building at #97. - Revise the elevation. 3. When resubmitting the changes to the exterior elevation as required above, please note that this house requires two forms of articulation since the frontage exceeds 50'.
ZON HOLD 05/22/2020 05/22/2020
Note: Held By: TDOAK No new plans submitted. Roofing worksheet shows a flat roof Per The LDC chapter 13 Section -13.03 All single family buildings shall have a pitched roof covereing a minimum of 65% of the overall floor area under roof Roof pitch must be at least a 5:12 and shall have an overhang beyond the building wall Flat roofed areas including, but not limited to, porches are permissible in the remaining 35% of floor area under roof. Per the LDC, "the corners of the home shall be wrapped with shrubbery or have an understory tree planted there." (SEE FRONT RIGHT SIDE OF HOME) Two identical homes cannot be built within 4 lots of each other. This home is identical to the one you are building at #97. When resubmitting the changes to the exterior elevation as required above, please note that this house requires two forms of articulation since the frontage exceeds 50'.
BLD HOLD 02/13/2020 02/18/2020
Note: Held By: JPI 1. On the roofing worksheet, please provide the underlayment type. 2. On the product approval worksheet, please complete sections for siding, lintel, underlayment (if not on the roofing worksheet) and structural components. 3. Garage door entrance. R302.5.1 Other openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13/8 inches (35 mm) thick, or 20-minute fire-rated doors. Please label the door option. 4. Add label with note at garage walls. R302.5.2 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage.
CUSVC COMPLETE 02/13/2020 02/13/2020
Note: Released By: HHAND
ELEC COMPLETE 02/13/2020 02/18/2020
Note: Released By: JMUNSON
ENGIN1 COMPLETE 02/13/2020 02/13/2020
Note: Released By: TBAKER
LOCATE COMPLETE 02/13/2020 02/14/2020
Note: Released By: CSTONE
MECH HOLD 02/13/2020 02/14/2020
Note: Held By: CPISCITELLI Provide duct layout signed by the AC contractor
PLUM COMPLETE 02/13/2020 02/18/2020
Note: Released By: JPI
SW1 COMPLETE 02/13/2020 02/19/2020
Note: Released By: CTROHA
UD1 COMPLETE 02/13/2020 02/20/2020
Note: Released By: AHALL
ZON HOLD 02/13/2020 02/13/2020
Note: Held By: TDOAK 1. Per the LDC, "the corners of the home shall be wrapped with shrubbery or have an understory tree planted there." 2. Two identical homes cannot be built within 4 lots of each other. This home is identical to the one you are building at #97. 3. When resubmitting the changes to the exterior elevation as required above, please note that this house requires two forms of articulation since the frontage exceeds 50'.
SWALE COMPLETE 02/13/2020 03/02/2020
Note: Released By: TBAKER

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 05/12/2021
STORMWATER REINSPECTION FEE ¤40.00 05/12/2021
STORMWATER REINSPECTION FEE ¤40.00 05/12/2021
STORMWATER REINSPECTION FEE ¤40.00 05/12/2021
3% TRANS IMPACT FEE CREDIT (¤50.22) 06/18/2020
SEWER INSPECTION ¤25.00 06/18/2020
SEWER CAPITAL FACILITY ¤4,596.07 06/18/2020
WATER CAPITAL FACILITY FEE ¤3,374.18 06/18/2020
NEW RESIDENTIAL INSPECTIONS ¤380.00 06/18/2020
SITE PLAN 20 ¤20.00 06/18/2020
SURCHARGE FS 533.721 ¤9.42 06/18/2020
SURCHARGE - FS 468.631 ¤14.13 06/18/2020
STORM WATER PERMIT FEES ¤80.00 06/18/2020
METER - DEPOSIT ¤60.00 06/18/2020
WATER- TURN ON ¤25.00 06/18/2020
ADMIN FEE ¤20.00 06/18/2020
CONNECTION FEES ¤1,002.88 06/18/2020
ELECTRIC FEE ¤174.00 06/18/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 06/18/2020
IMPACT FEE FIRE ¤223.38 06/18/2020
IMPACT FEE PARKS ¤849.24 06/18/2020
IMPACT FEE SCHOOL ¤3,600.00 06/18/2020
IMPACT FEE TRANSPORTATION ¤1,674.00 06/18/2020
MECHANICAL FEE ¤174.00 06/18/2020
WATER -IRRIGATION INSPECTION ¤25.00 06/18/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 06/18/2020
PLAN CHECK FEE ¤76.00 06/18/2020
PLUMBING FEE ¤174.00 06/18/2020
Fees Total Due: ¤0.00 Total Paid: ¤16,653.90