I want to search for...

Permit #2020030197

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00100-0240
CONDITIONED SPACE: 1853 sqft
GARAGE: 446 sqft
OPENED PORCH (WITH ROOF) : 142 sqft
OPENED PORCH (WITH ROOF) : 80 sqft
Total Square Footage: 2521 sqft
Block: 00100
Subdivision: 2167 - SECTION 24-PINE GROVE
Job Phone: 386-931-5395
Location Address: 70 PRINCE ERIC LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/17/2020
NOC: RECORDED
Applicant name: RYAN JAMES PERRY
Owner: BARARDO, OLIVIO E

Address

9 AIDA CT

LODI, NJ 07644

Lot: 0240
Contracted Stated Job Value: ¤165,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

WATERSIDE HOMES RENOVATIONS AND DESIGNS INC
Status Location Address State License Number Phone
ACTIVE

10 BISCAYNE DRIVE

PALM COAST, FL 32137

CBC1263021 (Exp: 08/31/2026) 386-931-5395

Sub Contractors

PETER JOSEPH LYDEN
Status Location Address State License Number Phone
CANCEL

17 UNIMAY CT

BUNNELL, FL 32110

EC0002436 (Exp: 08/31/2022) 386-931-2568
RYAN JAMES PERRY
Status Location Address State License Number Phone
ACTIVE

10 BISCAYNE DRIVE

PALM COAST, FL 32137

CBC1263021 (Exp: 08/31/2026) 386-931-5395
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 09/23/2020 APPROVED MBACON
Note: THIS IS A REINSPECTION no irrigation-residence being sprinkled
BLD - BUILDING FINAL 09/21/2020 FINAL APPROVED MMESSER
ELECTRIC - EARLY POWER 09/21/2020 APPROVED - AS NOTED JBODEN
Note: emailed FPL
U-CROSS CONNECTION 09/21/2020 PARTIALLY APPROVED LFITZGERALD
Note: no irrigation-residence being sprinkled
U -UTILITY RESIDENTIAL FINAL 09/21/2020 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 09/17/2020 Disapproved - NO FEE KHOWELL
Note: STILL NEED TO CUT TRENCHED THREW WOODS SO WATER CAN DRAIN. SWALE ELEVATION IS TO HIGH ON THE RIGHT SIDE OF THE DRIVEWAY CAUSING SWALE TO BACK UP UPSTREAM, NEEDS TO BE LOWERED ALMOST 0.3'
ROW FIELD SURVEY /GRADING CERTIFICATION 09/17/2020 APPROVED KHOWELL
Note: WORK DONE
ROW - STORMWATER FINAL 09/17/2020 FINAL APPROVED KHOWELL
ROW - FINAL APRON (AFTER POUR) 09/17/2020 APPROVED KHOWELL
FINAL SURVEY (OFFICE USE ONLY) 09/17/2020 APPROVED KHOWELL
ROW - FINAL APRON (AFTER POUR) 09/08/2020 Disapproved - NO FEE KHOWELL
Note: FINAL OFFICE SURVEY NEEDS TO BE APPROVED PRIOR TO THIS INSPECTION BEING DONE
ROW- PRE-APRON (PRE-POUR) 08/06/2020 APPROVED KHOWELL
Note: READY TO POUR IF IT RAINS BEFORE CONCRETE IS POURED RECHECK CULVERT ELEVATIONS
U - SEWER TIE IN 08/04/2020 APPROVED JGIBSON
GRAVITY SEWER TEST 08/04/2020 APPROVED JGIBSON
ROW- PROJECT STATUS 08/04/2020 APPROVED KHOWELL
Note: MET ON SITE WITH CONTRACTOR TO LOOK AT CABLE BOX IN ROW, IT SHOULD NOT CAUSE ANT ISSUE WITH THE PROPOSED DRIVEWAY
LATH/BRICK/ WATER BARRIER 06/26/2020 APPROVED JCOLASANTI
INSULATION 06/25/2020 APPROVED MMESSER
ALL ROUGH 06/22/2020 APPROVED MMESSER
ROOF VALLEY & METAL 06/01/2020 APPROVED MMESSER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/27/2020 APPROVED MMESSER
ELECTRIC-TUG 05/18/2020 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 10:40
TIE BEAM / LINTEL 04/24/2020 APPROVED WMILLER
FOUND SURVEY APPROVED (OFFICE) 04/22/2020 APPROVED TBAKER
MONOLITHIC SLAB 04/09/2020 APPROVED JCOLASANTI
PLUMBING 1ST ROUGH UNDERGROUND 04/03/2020 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 03/25/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 04/22/2020 04/22/2020
Note: Released By: TBAKER
ZON COMPLETE 04/22/2020 04/22/2020
Note: Released By: AMOBLEY
SW1 COMPLETE 03/13/2020 03/13/2020
Note: Released By: CTROHA
ENGIN1 COMPLETE 03/11/2020 03/16/2020
Note: Released By: TBAKER
UD1 COMPLETE 03/11/2020 03/13/2020
Note: Released By: AHALL
LOCATE COMPLETE 03/11/2020 03/12/2020
Note: Released By: CSTONE
ZON COMPLETE 03/11/2020 03/12/2020
Note: Released By: ELENS
SW1 HOLD 03/11/2020 03/13/2020
Note: Held By: CTROHA Applicant needs to provide existing elevations and proposed on a 20' grid on property lines as well as 10' into adjacent properties. must match existing elevations @ property line on improved lots
BLD COMPLETE 03/09/2020 03/09/2020
Note: Released By: PBUCKLEY Key Note C provides detail on house / garage fire rated door.
PLUM COMPLETE 03/09/2020 03/09/2020
Note: Released By: PBUCKLEY Note on plans indicates 4 inch sewer. Advised applicant to label plumbing riser with sewer size for permits in the future.
BLD HOLD 03/05/2020 03/07/2020
Note: Held By: JPI 1. Garage door entrance. R302.5.1 Other openings between the garage and residence shall be equipped with solid wood doors not less than 1 3/8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 1-3/8 inches (35 mm) thick, or 20-minute fire-rated doors. Please label the door option.
CUSVC COMPLETE 03/05/2020 03/09/2020
Note: Released By: HHAND
ELEC COMPLETE 03/05/2020 03/06/2020
Note: Released By: JMUNSON
ENGIN1 COMPLETE 03/05/2020 03/05/2020
Note: Released By: TBAKER
LOCATE COMPLETE 03/05/2020 03/06/2020
Note: Released By: CSTONE
MECH COMPLETE 03/05/2020 03/05/2020
Note: Released By: CPISCITELLI
PLUM HOLD 03/05/2020 03/07/2020
Note: Held By: JPI 1. Please label the sewer size on the riser diagram
SW1 HOLD 03/05/2020 03/06/2020
Note: Held By: CTROHA Applicant must match existing elevations at the property line of improved lots and show proposed drainage conveyance inside the property line.
UD1 COMPLETE 03/05/2020 03/10/2020
Note: Released By: LFITZGERALD
ZON HOLD 03/05/2020 03/06/2020
Note: Held By: ELENS The layout on the floor plan does not match the site plan and the landscape plan. All three must match.
SWALE COMPLETE 03/05/2020 03/31/2020
Note: Released By: TBAKER

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
METER - DEPOSIT ¤60.00 03/17/2020
WATER- TURN ON ¤25.00 03/17/2020
ADMIN FEE ¤20.00 03/17/2020
CONNECTION FEES ¤1,002.88 03/17/2020
ELECTRIC FEE ¤199.80 03/17/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 03/17/2020
IMPACT FEE FIRE ¤223.38 03/17/2020
IMPACT FEE PARKS ¤849.24 03/17/2020
IMPACT FEE SCHOOL ¤3,600.00 03/17/2020
IMPACT FEE TRANSPORTATION ¤1,674.00 03/17/2020
MECHANICAL FEE ¤199.80 03/17/2020
WATER -IRRIGATION INSPECTION ¤25.00 03/17/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 03/17/2020
PLAN CHECK FEE ¤93.20 03/17/2020
PLUMBING FEE ¤199.80 03/17/2020
NEW RESIDENTIAL INSPECTIONS ¤466.00 03/17/2020
SITE PLAN 20 ¤20.00 03/17/2020
SURCHARGE FS 533.721 ¤11.05 03/17/2020
SURCHARGE - FS 468.631 ¤16.58 03/17/2020
STORM WATER PERMIT FEES ¤80.00 03/17/2020
3% TRANS IMPACT FEE CREDIT (¤50.22) 03/17/2020
SEWER CREDIT (¤1,147.00) 03/17/2020
SEWER INSPECTION ¤25.00 03/17/2020
SEWER CAPITAL FACILITY ¤4,596.07 03/17/2020
WATER CAPITAL FACILITY FEE ¤3,374.18 03/17/2020
Fees Total Due: ¤0.00 Total Paid: ¤15,531.58