I want to search for...

Permit #2020030268

Permit Details

Status: COED

Parcel Id: 33-11-31-3061-00050-0090
CONDITIONED SPACE: 2008 sqft
CONDITIONED SPACE: 300 sqft
OPENED PORCH (WITH ROOF) : 167 sqft
OPENED PORCH (WITH ROOF) : 474 sqft
GARAGE: 776 sqft
OPENED PORCH (WITH ROOF) : 76 sqft
Total Square Footage: 3801 sqft
Block: 00050
Subdivision: 2108 - HIDDEN LAKES PHASE II - TOSCANA
Job Phone: 863-420-2100
Location Address: 22 NEW LEATHERWOOD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/03/2020
NOC: RECORDED
Applicant name: YUVAL BOTANSKY
Owner: APPLIED BUILDING DEVELOPMENT OF ORLANDO - PC INC

Address

131 CHADWICK DRIVE

DAVENPORT, FL 33837

Lot: 0090
Contracted Stated Job Value: ¤325,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

APPLIED BUILDING DEVELOPMENT COMPANY - OAKHILLS IN
Status Location Address State License Number Phone Fax
ACTIVE

131 CHADWICK DRIVE

DAVENPORT, FL 33837

CRC1330762 (Exp: 08/31/2026) 863-420-2100 386-517-6865

Sub Contractors

TERRY HILE BURD
Status Location Address State License Number Phone Fax
INACTIVE

PO Box 180308

CASSELBERRY, FL 32707

CAC1814423 (Exp: 08/31/2024) (407) 831-3600 (407)831-2893
DAVID MILLER
Status Location Address State License Number Phone
CANCEL

2659 MERCY DRIVE

ORLANDO, FL 32808

06157 (Exp: 08/31/2024) 407-466-6514
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JOSEPH H STRADA JR
Status Location Address State License Number Phone
CANCEL

3400 ST JOHNS PKWY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2022) 877-906-1113

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/18/2020 CANCELLED BY APPLICANT RMARTIN
Note: WRONG DATE NEEDS TO BE 12/17/20
BLD - BUILDING FINAL 12/18/2020 FINAL APPROVED MMESSER
Note: THIS IS A REINSPECTION WRONG DATE NEEDS TO BE 12/17/20
ROW - FINAL APRON (AFTER POUR) 12/17/2020 APPROVED - AS NOTED KRUTH
Note: clean road and sidewalk
U -UTILITY RESIDENTIAL FINAL 12/17/2020 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 12/16/2020 APPROVED KRUTH
ROW - STORMWATER FINAL 12/16/2020 APPROVED KRUTH
FINAL SURVEY (OFFICE USE ONLY) 12/16/2020 APPROVED KRUTH
GAS FINAL 12/14/2020 APPROVED JGIBSON
U-CROSS CONNECTION 12/14/2020 APPROVED LFITZGERALD
ELECTRIC - EARLY POWER 12/04/2020 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL 11:05 am
ROW- PRE-APRON (PRE-POUR) 12/03/2020 APPROVED - AS NOTED KRUTH
Note: THIS IS A REINSPECTION I SPOKE WITH SUPER SOME HIGHER SPOT ON THE SIDE WALK HE IS GOING TO TAKE CARE ROBERT ALREADY DID THE INSPECTION ON12/2/2020
ROW- PAVER RESTRAINTS 11/23/2020 APPROVED GBERTOLA
ROW- PRE-APRON (PRE-POUR) 11/20/2020 PARTIALLY APPROVED GBERTOLA
Note: I SPOKE WITH SUPER SOME HIGHER SPOT ON THE SIDE WALK HE IS GOING TO TAKE CARE
TIE BEAM / LINTEL 11/18/2020 APPROVED FWILLIS
U - SEWER TIE IN 11/09/2020 APPROVED JGIBSON
GRAVITY SEWER TEST 11/09/2020 APPROVED JGIBSON
LATH/BRICK/ WATER BARRIER 10/09/2020 APPROVED FWILLIS
INSULATION 10/02/2020 APPROVED FWILLIS
ALL ROUGH 10/01/2020 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION 5ft HEAD OF WATER, 6TH EDITION FBC CHAPTER 25 SECTION P2503.5.1 (1) and or FBC CHAPTER 25 SECTION P2503.5.1 BUILDING SEWER TESTING Must use water for testing plastic pipes. Testing with not less than 5-foot (3048mm) of head water and be able to maintain such pressure for 15 minutes. 10/1/20 FOREST WENT BACK TO CHECK 5FT HEAD, THIS INSPECTION WAS ALREADY APPROVED
ALL ROUGH 09/29/2020 APPROVED FWILLIS
Note: 5ft HEAD OF WATER, 6TH EDITION FBC CHAPTER 25 SECTION P2503.5.1 (1) and or FBC CHAPTER 25 SECTION P2503.5.1 BUILDING SEWER TESTING Must use water for testing plastic pipes. Testing with not less than 5-foot (3048mm) of head water and be able to maintain such pressure for 15 minutes.
GAS ROUGH 09/29/2020 APPROVED JGIBSON
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/28/2020 APPROVED FWILLIS
Note: THIS IS A REINSPECTION Verify Engineering using Lateral Bracing (2X's) is acceptable on multiple truss.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/04/2020 Disapproved - NO FEE FWILLIS
Note: Verify Engineering using Lateral Bracing (2X's) is acceptable on multiple truss.
ELECTRIC-TUG 08/28/2020 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 11:20 am
ROOF VALLEY & METAL 08/13/2020 APPROVED MMESSER
ROOF SHEATHING 08/06/2020 APPROVED FWILLIS
TIE BEAM / LINTEL 07/29/2020 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 07/28/2020 APPROVED TBAKER
MONOLITHIC SLAB 07/17/2020 APPROVED FWILLIS
Note: THIS IS A REINSPECTION Several Dowels missing and misplaced in front entry area. Inspection Stopped!! Page S1 on Approved Drawings.
MONOLITHIC SLAB 07/16/2020 Disapproved - NO FEE FWILLIS
Note: Several Dowels missing and misplaced in front entry area. Inspection Stopped!! Page S1 on Approved Drawings.
PLUMBING 1ST ROUGH UNDERGROUND 07/14/2020 APPROVED JGIBSON
FOOTER 06/30/2020 APPROVED FWILLIS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Plans in Construction Box Wet and balled up. Need Readable Approved Plans. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. FOOTER has caved-in In several places. REBAR needs 2 -3" of clearance. MUD-CANNOT ADHERE TO REBAR PER ACI 318 6-26-2020Still not ready see notes above
FOOTER 06/26/2020 Disapproved - NO FEE WMILLER
Note: THIS IS A REINSPECTION Plans in Construction Box Wet and balled up. Need Readable Approved Plans. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. FOOTER has caved-in In several places. REBAR needs 2 -3" of clearance. MUD-CANNOT ADHERE TO REBAR PER ACI 318 6-26-2020Still not ready see notes above
FOOTER 06/25/2020 Disapproved -FEE REQUIRED FWILLIS
Note: Plans in Construction Box Wet and balled up. Need Readable Approved Plans. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. FOOTER has caved-in In several places. REBAR needs 2 -3" of clearance. MUD-CANNOT ADHERE TO REBAR PER ACI 318
FOOTER 06/24/2020 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 06/24/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
ZON COMPLETE 07/27/2020 07/27/2020
Note: Released By: AMOBLEY
ENGIN1 COMPLETE 07/27/2020 07/28/2020
Note: Released By: TBAKER
BLD COMPLETE 03/26/2020 04/01/2020
Note: Released By: FREODICA
SW1 COMPLETE 03/19/2020 03/19/2020
Note: Released By: CTROHA
MECH COMPLETE 03/19/2020 03/20/2020
Note: Released By: CPISCITELLI
ELEC COMPLETE 03/19/2020 03/23/2020
Note: Released By: JMUNSON
BLD HOLD 03/19/2020 03/26/2020
Note: Held By: FREODICA Review comment on Revised Product Approval Sheet per FS 553.842 1. FL 435.4 R22 for single hung window, FL 822.-22 for wood anchor and FL 12045 R2 for lintel can not be found on FL Product Approval Listing. 2. FL 11470 is not wood anchor but wood connector. FReodica-386-986-4734.
URB COMPLETE 03/09/2020 03/13/2020
Note: Released By: JBEAUDET
BLD HOLD 03/06/2020 03/13/2020
Note: Held By: FREODICA 1. Floor plan : Provide opening protection between garage and residence with a solid wood door not less than 1-3/8 inches thick or honeycomb steel door not less than 1-3/8 inches thick or a 20-minute fire- rated door per FBCR 6th ed. sec. R302.5.1. 2. Roofing worsheet : Provide updated Form from City's website and completely filled-in with correct underlayment for clarity per FBC 6th ed. 107.2.1. 3. Product approval sheet per FS 553.842: a. Sliding glass dooor FL 251R-24 can not be found on code version 2017 FL Product Approval Listing. The provided Model 470 SGD was found on code version 2010. Provide the correct FL number based on upadated code version. b. Garage doors FL number are missing. c. Tile roffing material FL number is missing. The provided FL number 14317 is for underlayment material. d. Soffits and wood anchors FL numbers are missing. FReodica-386-986-4734.
CUSVC COMPLETE 03/06/2020 03/10/2020
Note: Released By: HHAND
ELEC HOLD 03/06/2020 03/10/2020
Note: Held By: JMUNSON Need Electrical Load Calculations
ENGIN1 COMPLETE 03/06/2020 03/10/2020
Note: Released By: TBAKER
LOCATE COMPLETE 03/06/2020 03/09/2020
Note: Released By: CSTONE
MECH HOLD 03/06/2020 03/06/2020
Note: Held By: CPISCITELLI 1. EPL card needs to be signed by the builder 2. Orientation on the energy calc does not match the site plan. Revise calcs
PLUM COMPLETE 03/06/2020 03/13/2020
Note: Released By: FREODICA
SW1 HOLD 03/06/2020 03/06/2020
Note: Held By: CTROHA Applicant needs to show proposed and existing elevations on a 20' grid also show proposed drainage elevations. Applicant needs to provide FFE along with adjacent improved lots FFE Applicant needs to provide final sod elevations at all four corners of the foundation
UD1 COMPLETE 03/06/2020 03/10/2020
Note: Released By: LFITZGERALD
ZON COMPLETE 03/06/2020 03/09/2020
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 12/14/2020
NEW RESIDENTIAL INSPECTIONS ¤650.00 04/03/2020
SITE PLAN 20 ¤20.00 04/03/2020
SURCHARGE FS 533.721 ¤14.55 04/03/2020
SURCHARGE - FS 468.631 ¤21.83 04/03/2020
STORM WATER PERMIT FEES ¤80.00 04/03/2020
3% TRANS IMPACT FEE CREDIT (¤91.77) 04/03/2020
SEWER INSPECTION ¤25.00 04/03/2020
METER - DEPOSIT ¤60.00 04/03/2020
WATER-METER ¤434.59 04/03/2020
WATER-METER ¤361.04 04/03/2020
ADMIN FEE ¤20.00 04/03/2020
CONNECTION FEES ¤25.00 04/03/2020
ELECTRIC FEE ¤255.00 04/03/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 04/03/2020
IMPACT FEE FIRE ¤223.38 04/03/2020
IMPACT FEE PARKS ¤849.24 04/03/2020
IMPACT FEE SCHOOL ¤3,600.00 04/03/2020
IMPACT FEE TRANSPORTATION ¤3,059.00 04/03/2020
MECHANICAL FEE ¤255.00 04/03/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 04/03/2020
PLAN CHECK FEE ¤130.00 04/03/2020
PLUMBING FEE ¤255.00 04/03/2020
Fees Total Due: ¤0.00 Total Paid: ¤10,254.68