I want to search for...
Permit #2020030707
Permit Details
Status: COED
| Parcel Id: 07-11-31-7013-00190-0190 |
| CONDITIONED SPACE: 1500 sqft |
| GARAGE: 380 sqft |
| OPENED PORCH (WITH ROOF) : 140 sqft |
| OPENED PORCH (WITH ROOF) : 32 sqft |
| Total Square Footage: 2052 sqft |
| Block: 00190 |
| Subdivision: 2192 - SECTION 13-BELLE TERRE |
| Job Phone: 386-248-0033 |
| Location Address: 39 BRUNING LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/21/2020 |
| NOC: RECORDED |
| Applicant name: JEFFREY T WISE |
| Owner: 3S HOUSING, LLC |
|
Address 226 N NOVA ROAD ORMOND BEACH, FL 32174 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤190,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
WISE BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
120 CARSWELL AVE HOLLY HILL, FL 32117 |
CGC055237 (Exp: 08/31/2026) | 386-248-0033 |
Sub Contractors
NORMAN J VAN HORNE
| Status | Location Address | State License Number | Phone |
| CANCEL |
PO BOX 251228 HOLLY HILL, FL 32117 |
CFC032605 (Exp: 08/31/2022) | (386)258-0608 |
JAMES R DOOLEY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1550 GARDEN AVENUE HOLLY HILL, FL 32117 |
EC13005817 (Exp: 08/31/2026) | 386-672-4433 | 386-672-9793 |
KEVIN HENRY BEHRENS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1200 SOUTH NOVA ROAD DAYTONA BEACH, FL 32114 |
CAC054733 (Exp: 08/31/2026) | (386)761-7751 | (386) 258-0058 |
JEFFREY T WISE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
120 CARSWELL AVE HOLLY HILL, FL 32117 |
CCC049377 (Exp: 08/31/2026) | 386-248-0033 | 386-248-0033 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/12/2020 | CANCELLED BY APPLICANT | WEB |
| Note: Key to entry is in lock box attached to hose bib on the right side of home. code is (3223). Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| BLD - BUILDING FINAL | 11/12/2020 | FINAL APPROVED | JCOLASANTI |
| Note: Key to entry is in the lock box attached to hose bib on the right side of the house. (3223) Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| BLD - BUILDING FINAL | 11/10/2020 | Disapproved - NO FEE | JCOLASANTI |
| Note: Key to entry, is on right side of the house, lock box on hose bib. ( 3223 ) Any questions please call Jeff Wise at 386-299-4536. Thanks need final termite sticker posted....need to seal hole at electric panel ceiling....need GFI at laundry room outlet, not tripping | |||
| U-CROSS CONNECTION | 11/09/2020 | APPROVED - AS NOTED | JHARDING |
| Note: Any questions please call Jeff Wise at 386-299-4536. Thanks Approved No Irr., No Cross CN. | |||
| U -UTILITY RESIDENTIAL FINAL | 11/09/2020 | FINAL APPROVED | JHARDING |
| Note: Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| ROW - STORMWATER FINAL | 11/06/2020 | APPROVED | KRUTH |
| Note: Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| ROW - FINAL APRON (AFTER POUR) | 11/06/2020 | APPROVED | KRUTH |
| Note: Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| FINAL SURVEY (OFFICE USE ONLY) | 11/05/2020 | APPROVED | KRUTH |
| Note: THIS IS A REINSPECTION WRONG SIZE DRIVEWAY CULVERT INSTALLED PER FINAL SURVEY. 11/5/2020 CORRECTIONS MADE | |||
| FINAL SURVEY (OFFICE USE ONLY) | 11/04/2020 | Disapproved - NO FEE | RGROSS |
| Note: WRONG SIZE DRIVEWAY CULVERT INSTALLED PER FINAL SURVEY. | |||
| ELECTRIC - EARLY POWER | 09/30/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: We will be there from about 9:30 till about 2, pouring the driveway. If no one there, the key to enter the house is in a lock box that is attached to a hose bib on the RH side of the house, Entry code for lockbox is 3223. Any questions please call Jeff Wise at 386-299-4536. EMAILED FPL RELEASED POWER 12:00 Thanks | |||
| ROW- PRE-APRON (PRE-POUR) | 09/29/2020 | APPROVED - AS NOTED | GBERTOLA |
| Note: CHECK CULVERT ELEVATION BEFORE POUR . SUPER ON SITE | |||
| ROW- PRE-APRON (PRE-POUR) | 09/28/2020 | Disapproved - NO FEE | GBERTOLA |
| Note: MATERIAL TO SOFT TO O MUCH WATER THROUGH THE PIPE, SUPER ON SITE | |||
| ROW- PRE-APRON (PRE-POUR) | 09/25/2020 | Disapproved -FEE REQUIRED | RGROSS |
| Note: Any questions please call Jeff Wise at 386-299-4536. MITERED ENDS MUST BE 18 INCHES FROM THE SIDE OF THE PIPE TO THE TOP OF THE MITER. NOT 18 INCHES FROM CENTER OF CULVERT. PIPE MUST BE 8 FT FROM ROAD EDGE ON BOTH ENDS OF THE CULVERT GRADE ON THE SIDES OF THE PIPE MUST GRADUALLY ASCEND TO THE SURROUNDING GRADE TO HAVE AN EVEN DISTRIBUTION OF CONCRETE WEIGHT. CANNOT BE CANYONED. | |||
| U - SEWER TIE IN | 09/23/2020 | APPROVED | JGIBSON |
| Note: Any questions please contact Jeff Wise at 386-299-4536. | |||
| LATH/BRICK/ WATER BARRIER | 08/06/2020 | APPROVED | JCOLASANTI |
| Note: Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| INSULATION | 07/31/2020 | APPROVED | JCOLASANTI |
| Note: Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| INSULATION | 07/30/2020 | Disapproved - NO FEE | JCOLASANTI |
| Note: Looking for an inspection after mid morning, if possible. Any questions please call Jeff Wise at 386-299-4536. Thanks need roof complete by insulation | |||
| ALL ROUGH | 07/27/2020 | APPROVED - AS NOTED | JCOLASANTI |
| Note: Any questions please call Jeff Wise at 386-299-4536. Thanks need to frame electric panel.. need coorect guage plate at dryer vent (by insulation0 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/24/2020 | APPROVED | JCOLASANTI |
| Note: Approved Revision sheet in the permit box. Any questions please call Jeff Wise at 386-299-4536. Thanks | |||
| ROOF VALLEY & METAL | 07/24/2020 | APPROVED | JCOLASANTI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 07/01/2020 | PARTIALLY APPROVED | JCOLASANTI |
| Note: just wanted dry in, ok....need to call in braces , ties and engineering | |||
| FOUND SURVEY APPROVED (OFFICE) | 06/10/2020 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 06/08/2020 | APPROVED | JCOLASANTI |
| MONOLITHIC SLAB | 06/02/2020 | APPROVED | JCOLASANTI |
| ELECTRIC UNDERGROUND | 06/02/2020 | Disapproved - NO FEE | RMARTIN |
| Note: DOES NOT APPEAR ANY ELECTRIC HAS BEED DONE | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 05/29/2020 | APPROVED | JGIBSON |
| ELECTRIC TEMP POLE | 05/06/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 11:45 | |||
| WATER METER INSTALLATION REQUEST | 05/06/2020 | APPROVED | CSTONE |
| GRAVITY SEWER TEST | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | COMPLETE | 11/04/2020 | 11/04/2020 |
| Note: Released By: MDEFREITAS | |||
| BADMIN | HOLD | 11/03/2020 | 11/03/2020 |
| Note: Held By: STHOMAS RENAME TO ONLY FINAL SURVEY.PDF | |||
| BADMIN | HOLD | 10/30/2020 | 10/30/2020 |
| Note: Held By: STHOMAS RENAME TO TERMITE.PDF | |||
| BLD | COMPLETE | 07/16/2020 | 07/23/2020 |
| Note: Released By: FREODICA Revision: changed beam detail on Sht. S-1. | |||
| BADMIN | HOLD | 06/09/2020 | 06/09/2020 |
| Note: Held By: STHOMAS RENAME TO FOUNDATION SURVEY.PDF | |||
| BADMIN | COMPLETE | 06/09/2020 | 06/09/2020 |
| Note: Released By: STHOMAS | |||
| ENGIN1 | COMPLETE | 06/09/2020 | 06/10/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 06/09/2020 | 06/09/2020 |
| Note: Released By: TDOAK | |||
| SWALE | COMPLETE | 04/14/2020 | 05/29/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 04/13/2020 | 04/14/2020 |
| Note: Released By: AMOBLEY | |||
| ENGIN1 | COMPLETE | 04/13/2020 | 04/14/2020 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 04/13/2020 | 04/14/2020 |
| Note: Released By: CPISCITELLI | |||
| BLD | COMPLETE | 04/13/2020 | 04/20/2020 |
| Note: Released By: FREODICA | |||
| ENGIN1 | HOLD | 03/25/2020 | 03/26/2020 |
| Note: Held By: TBAKER Site plan needs an acceptable benchmark. Acceptable benchmarks are: Nail in power pole, fire hydrant, manhole cover If none of the above are within a reasonable distance of the site a nail & disk in the asphalt will be allowed. | |||
| ZON | HOLD | 03/25/2020 | 03/25/2020 |
| Note: Held By: ELENS Revised site plan has the legal description cut off. | |||
| PLENV | COMPLETE | 03/25/2020 | 03/25/2020 |
| Note: Released By: JMYERS The Gopher Tortoise survey has been accepted. Suggest to silt fence the property so that no Tortoise will enter the site prior to commencing construction. | |||
| MECH | HOLD | 03/25/2020 | 03/27/2020 |
| Note: Held By: CPISCITELLI Duct layout is incomplete. Provide complete duct layout with duct sizes | |||
| BLD | HOLD | 03/25/2020 | 03/31/2020 |
| Note: Held By: FREODICA Repeat comments 1. Provide truss layout with connectors signed and sealed by engineer of record per FBC 6th ed. 107.2.1/1607.12 2. Provide Product approval for sofffits, and structural components such as wood connectots, wood anchors, truss plates and lintels per FS 553.842. 3. Floor Plan: a. Indicate what type of door to be used between garage and residence to comply with FBCR 6th ed, sec, R302,5,1 b. Add label with note at garage walls. R302.5.2 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage. FReodica -386-986-4734 Additional comment: Provide design criteria per FBCR 6th ed. sec. R301. | |||
| MECH | HOLD | 03/18/2020 | 03/18/2020 |
| Note: Held By: CPISCITELLI 1. R403.7.1.2.1 FBC Energy Conservation- Chosen equipment exceeds the maximum of 1.15 times the load calculated. 2. Floor plan is inconsistent with glazing from the Energy Calcs 3. Provide Duct Layout | |||
| PLENV | HOLD | 03/18/2020 | 03/18/2020 |
| Note: Held By: JMYERS Gopher Tortoise have been noted in the vicinity of this project. Please provide a Gopher Tortoise survey done by a Qualified Environmental Professional that no Gopher Tortoise or their burrows are within 25ft of construction activities. | |||
| ZON | HOLD | 03/18/2020 | 03/18/2020 |
| Note: Held By: TDOAK Held By: ELENS Please provide total lot square footage on the site plan. Please provide the sizes of the proposed landscape shrubs. Two more shrubs are required on the left side of the residence. (16 total, not including the 7 gallon shrubs required to screen the A/C pad. 8 are required along the front and four on each side.) Site plan must depict width of proposed front walkway. | |||
| BLD | HOLD | 03/17/2020 | 03/25/2020 |
| Note: Held By: FREODICA 1. Provide truss layout with connectors signed and sealed by engineer of record per FBC 6th ed. 107.2.1/1607.12 2. Provide Product approval for sofffits, and structural components such as wood connectots, wood anchors, truss plates and lintels per FS 553.842. 3. Floor Plan: a. Indicate what type of door to be used between garage and residence to comply with FBCR 6th ed, sec, R302,5,1 b. Add label with note at garage walls. R302.5.2 Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No. 26 gage (0.48 mm) sheet steel, 1 inch (25.4 mm) minimum rigid nonmetallic Class 0 or Class 1 duct board, or other approved material and shall not have openings into the garage. FReodica -386-986-4734 | |||
| CUSVC | COMPLETE | 03/17/2020 | 03/17/2020 |
| Note: Released By: HHAND | |||
| ELEC | COMPLETE | 03/17/2020 | 03/18/2020 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | HOLD | 03/17/2020 | 03/17/2020 |
| Note: Held By: TBAKER Survey needs benchmark in accordance with attached informational sheet. | |||
| LOCATE | COMPLETE | 03/17/2020 | 03/18/2020 |
| Note: Released By: CSTONE | |||
| PLUM | COMPLETE | 03/17/2020 | 03/25/2020 |
| Note: Released By: FREODICA | |||
| SW1 | COMPLETE | 03/17/2020 | 03/17/2020 |
| Note: Released By: CTROHA | |||
| UD1 | COMPLETE | 03/17/2020 | 03/23/2020 |
| Note: Released By: AHALL |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 09/25/2020 |
| REVISION | ¤40.00 | 07/23/2020 |
| SITE PLAN 20 | ¤20.00 | 04/21/2020 |
| SURCHARGE FS 533.721 | ¤9.42 | 04/21/2020 |
| SURCHARGE - FS 468.631 | ¤14.13 | 04/21/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/21/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 04/21/2020 |
| SEWER CREDIT | (¤1,147.00) | 04/21/2020 |
| SEWER INSPECTION | ¤25.00 | 04/21/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 04/21/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 04/21/2020 |
| METER - DEPOSIT | ¤60.00 | 04/21/2020 |
| WATER- TURN ON | ¤25.00 | 04/21/2020 |
| ADMIN FEE | ¤20.00 | 04/21/2020 |
| CONNECTION FEES | ¤1,002.88 | 04/21/2020 |
| ELECTRIC FEE | ¤174.00 | 04/21/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 04/21/2020 |
| IMPACT FEE FIRE | ¤223.38 | 04/21/2020 |
| IMPACT FEE PARKS | ¤849.24 | 04/21/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/21/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 04/21/2020 |
| MECHANICAL FEE | ¤174.00 | 04/21/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/21/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 04/21/2020 |
| PLAN CHECK FEE | ¤76.00 | 04/21/2020 |
| PLUMBING FEE | ¤174.00 | 04/21/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤380.00 | 04/21/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,426.90 |