I want to search for...

Permit #2020031027

Permit Details

Status: COED

Parcel Id: 35-11-31-4075-00000-0020
CONDITIONED SPACE: 1823 sqft
GARAGE: 485 sqft
OPENED PORCH (WITH ROOF) : 261 sqft
OPENED PORCH (WITH ROOF) : 60 sqft
Total Square Footage: 2629 sqft
Block: 00000
Subdivision: 2296 - MARINA DEL PALMA SUBDIVISION
Job Phone: 386-447-4400
Location Address: 4 DEL PALMA DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/30/2020
NOC: RECORDED
Applicant name: DAVID PAUL CROCKETT
Owner: BELFIELD JAMES D & LISA A BELFIELD H&W

Address

17 ROYALE LANE

PALM COAST, FL 32164

Lot: 0020
Contracted Stated Job Value: ¤325,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SALTWATER HOMES INC
Status Location Address Mailing Address State License Number Phone Fax
DECEASED

138 PALM COAST PARKWAY

PALM COAST, FL 32137

SUITE 328

PALM COAST, FL 32137

RG0041345 (Exp: 08/31/2025) 386-447-4400 866-244-9639

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
CHRISTOPHER DANIEL FULTON
Status Location Address Mailing Address State License Number Phone
ACTIVE

2 MARKET PLACE

PALM COAST, FL 32137

UNIT D

PALM COAST, FL 32137

CCC1331939 (Exp: 08/31/2026) 386-445-7945

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 05/03/2021 APPROVED - AS NOTED JHARDING
Note: Approved no cross connections
U -UTILITY RESIDENTIAL FINAL 04/26/2021 FINAL APPROVED JHARDING
BLD - BUILDING FINAL 04/26/2021 FINAL APPROVED WMILLER
ROW - STORMWATER FINAL 04/21/2021 APPROVED RGROSS
ROW - FINAL APRON (AFTER POUR) 04/21/2021 APPROVED RGROSS
ROW FIELD SURVEY /GRADING CERTIFICATION 04/19/2021 APPROVED - AS NOTED RGROSS
Note: Brass cap needed on the sewer cleanout in the driveway before scheduling the Final Apron Inspection.
FINAL SURVEY (OFFICE USE ONLY) 04/19/2021 APPROVED RGROSS
ROW- PRE-APRON (PRE-POUR) 03/26/2021 APPROVED GBERTOLA
Note: THIS IS A REINSPECTION Approved for Apron, sidewalk, and Paver restraints only. Paver Driveway.
ELECTRIC - EARLY POWER 03/12/2021 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 1:08 pm
ROW- PRE-APRON (PRE-POUR) 03/05/2021 PARTIALLY APPROVED RGROSS
Note: Approved for Apron, sidewalk, and Paver restraints only. Paver Driveway.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/05/2021 APPROVED RGROSS
INSULATION 10/15/2020 APPROVED MMESSER
LATH/BRICK/ WATER BARRIER 10/09/2020 APPROVED WMILLER
ALL ROUGH 10/08/2020 APPROVED - AS NOTED WMILLER
Note: (items mentioned at roof sheathing inspetion resolved) NEED THE FOLLOWING BY INSULATION 1. TUB TRENCH SEALED APPENDIX F 303.3.4.2 2. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/27/2020 APPROVED - AS NOTED WMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Not Ready Truss engineering packet does not match whatnis installed. Specifically B02 - B 05 Please provide proper truss packet 8-27-2020... Please correct the following by next inspection... 1. Missing fasteners at LUS24 (highlighted on plans) 2. Missing Bracing at truss B02 (per engineering) (highlighted in engineering packet)
ROOF VALLEY & METAL 08/27/2020 APPROVED WMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/11/2020 Disapproved -FEE REQUIRED JBODEN
Note: THIS IS A REINSPECTION Not Ready Truss engineering packet does not match whatnis installed. Specifically B02 - B 05 Please provide proper truss packet
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/04/2020 CANCELLED BY APPLICANT FWILLIS
Note: Not Ready
ELECTRIC-TUG 08/04/2020 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 1:20
ELECTRIC - EARLY POWER 08/04/2020 Disapproved - NO FEE RMARTIN
Note: THIS SHOULD BE A TUG INSPECTION..... I WILL ADD IT AND APPROVE IT, CALL IN EARLY POWER WHEN DRYWALL IS UP AND FIXTURES AND DEVICES ARE IN
TIE BEAM / LINTEL 07/15/2020 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 07/06/2020 APPROVED TBAKER
MONOLITHIC SLAB 06/17/2020 APPROVED WMILLER
Note: THIS IS A REINSPECTION footers are onley 6to 8inches deep 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE… R403.1.3.4 and in accordance with R401.2, and R403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE COMPACTION AND TERMITE TREATMENT NOTIFICATION IN BOX 1816.1.7 FBC Termite Protection intention of or completion prior to slab.
MONOLITHIC SLAB 06/11/2020 Disapproved -FEE REQUIRED JDELBONIS
Note: footers are onley 6to 8inches deep 12 inch MINIMUM DEPTH , UNDISTURBED GROUND SURFACE… R403.1.3.4 and in accordance with R401.2, and R403.1 ALL FOOTINGS SHALL BE PLACED AT LEAST 12 in. BELOW THE UNDISTURBED GROUND SURFACE COMPACTION AND TERMITE TREATMENT NOTIFICATION IN BOX 1816.1.7 FBC Termite Protection intention of or completion prior to slab.
PLUMBING 1ST ROUGH UNDERGROUND 06/04/2020 APPROVED JGIBSON
GRAVITY SEWER TEST 06/04/2020 APPROVED JGIBSON
U - SEWER TIE IN 06/04/2020 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 05/12/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD COMPLETE 08/18/2020 08/24/2020
Note: Released By: FREODICA Revision: changed truss layout.
ENGIN1 COMPLETE 07/02/2020 07/06/2020
Note: Released By: TBAKER Foundation Survey
ZON COMPLETE 07/02/2020 07/02/2020
Note: Released By: AMOBLEY
ZON COMPLETE 04/21/2020 04/22/2020
Note: Released By: AMOBLEY
ENGIN1 COMPLETE 04/21/2020 04/22/2020
Note: Released By: TBAKER
UD1 COMPLETE 04/21/2020 04/22/2020
Note: Released By: AHALL
ZON HOLD 04/09/2020 04/13/2020
Note: Held By: AMOBLEY Incorrect flood map number on survey/site plan AC pad location shows it located in the easement. It can not be in the easement
ELEC COMPLETE 04/09/2020 04/14/2020
Note: Released By: JMUNSON
BLD COMPLETE 04/09/2020 04/14/2020
Note: Released By: PBUCKLEY
BLD HOLD 04/08/2020 04/08/2020
Note: Held By: PBUCKLEY COMMENTS REMOVED AND REVISED FROM PREVIOUS REVIEW. PLEASE RESPOND TO ITEMS BELOW. 1. Please add smoke detector "in immediate vicinity" of Bedroom No. 3. This means in the hallway directly outside the bedroom. 2. Please relocate smoke detector in living room from its current location to a point centrally located between Bedroom No. 2 and Master Bedroom. FBCR Secton R314.3 3. Please revise exterior wall Section Notes to reflect materials to be installed on exterior side of exterior framed and CMU walls including water resistive barrier, furring if any, stucco.system, siding, all flashings between dis-similar materials and at window and doors and other openings so a complete detail of the exsterior weather-resistant envelope per FBCR R703. 4. Provide lintel tags on a plan which correlate back to the lintel per FBCR R606.10 5. Please provice product approval # for shutters or for non-impact glazing FBCR R609.11. 6. Please provide a product approval number for the peel & stick. Select the specific product being used.
URB COMPLETE 03/24/2020 03/24/2020
Note: Released By: JBEAUDET
BLD HOLD 03/23/2020 03/26/2020
Note: Held By: JPI 1. Provide the current building codes on the plans ([a] 107.2.1) 2.. Provide the criteria for wind on the plans, wind speed, exposure, ect. (r301.2.1) 3. Provide the required attachment resistance expressed as a moment for the roof tile. (r301.1) 4. The smoke detectors and carbon monoxide detectors are missing outside of the sleeping rooms. (r315.1) 5. Wall sections from foundation through roof are required per (107.3.5). provide a complete section include furring, framing, fire blocking, insulation, wall coverings, waterproofing, flashings, ect. 6. Sheet 4, foundation plan a. provide one option for each footer. b. provide detail for shower curb. 7. Provide lintel tags on a plan which correlate back to the lintel. ([a] 107.2.1, r606.10) 8. Please be specific for the roof sheathing identification thickness and grade. (r803.2.1) 9. Product approvals a. no product approval # provided for shutters, non-impact glazing is specified. (r609.11) b. select the method of attachment for the roof tile. ([a] 107.2.1) c. provide a product approval number for the peel & stick. select the specific product being used. ([a] 107.2.1)
CUSVC COMPLETE 03/23/2020 03/25/2020
Note: Released By: HHAND
ELEC HOLD 03/23/2020 03/24/2020
Note: Held By: JMUNSON Need to submit Load Calcs.
ENGIN1 COMPLETE 03/23/2020 03/24/2020
Note: Released By: TBAKER
LOCATE COMPLETE 03/23/2020 03/25/2020
Note: Released By: CSTONE
MECH COMPLETE 03/23/2020 03/24/2020
Note: Released By: CPISCITELLI
PLUM COMPLETE 03/23/2020 03/26/2020
Note: Released By: JPI
SW1 COMPLETE 03/23/2020 03/24/2020
Note: Released By: CTROHA
UD1 COMPLETE 03/23/2020 03/25/2020
Note: Released By: AHALL
ZON HOLD 03/23/2020 03/24/2020
Note: Held By: AMOBLEY Incorrect flood map number on survey/site plan AC pad location on construction plans in different location than the location on landscape and site plan. Please correct whichever is wrong

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REVISION ¤40.00 04/28/2021
REINSPECTION FEE ¤40.00 04/28/2021
REINSPECTION FEE ¤40.00 04/28/2021
NEW RESIDENTIAL INSPECTIONS ¤650.00 04/30/2020
SITE PLAN 20 ¤20.00 04/30/2020
SURCHARGE FS 533.721 ¤14.55 04/30/2020
SURCHARGE - FS 468.631 ¤21.83 04/30/2020
STORM WATER PERMIT FEES ¤80.00 04/30/2020
3% TRANS IMPACT FEE CREDIT (¤91.77) 04/30/2020
SEWER INSPECTION ¤25.00 04/30/2020
SEWER CAPITAL FACILITY ¤2,389.36 04/30/2020
WATER CAPITAL FACILITY FEE ¤2,234.43 04/30/2020
METER - DEPOSIT ¤60.00 04/30/2020
WATER-METER ¤434.59 04/30/2020
ADMIN FEE ¤20.00 04/30/2020
CONNECTION FEES ¤25.00 04/30/2020
ELECTRIC FEE ¤255.00 04/30/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 04/30/2020
IMPACT FEE FIRE ¤223.38 04/30/2020
IMPACT FEE PARKS ¤849.24 04/30/2020
IMPACT FEE SCHOOL ¤3,600.00 04/30/2020
IMPACT FEE TRANSPORTATION ¤3,059.00 04/30/2020
MECHANICAL FEE ¤255.00 04/30/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 04/30/2020
PLAN CHECK FEE ¤130.00 04/30/2020
PLUMBING FEE ¤255.00 04/30/2020
Fees Total Due: ¤0.00 Total Paid: ¤14,597.43