Permit #2020040113

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7013-00020-0010
Block: 00020
Subdivision: 2192 - SECTION 13-BELLE TERRE
Job Phone: 389-931-8793
Location Address: 89 BRADMORE LN
Type: ME - MECHANICAL
Issue Date: 04/06/2020
NOC: Unknown
Applicant name: OCLES PHILIUS PHILIPPE
Owner: ALEXIS MARIE GINETTE

Address

89 BRADMORE LANE

PALM COAST, FL 32137

Lot: 0010
Contracted Stated Job Value: ¤3,600.00
Job Description: 2.5 ton ac unit.heat pump ,5 kw and 14 seer
Type: CN

Contractor

A&L SERVICE SYSTEM LLC
Status Location Address State License Number Phone
ACTIVE

47 PICKERING DR

PALM COAST, FL 32164

CAC1818862 (Exp: 08/31/2026) 389-931-8793

Inspection History

Type Request Date Result Inspector
HVAC FINAL 07/10/2020 FINAL APPROVED CPISCITELLI
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Google Duo Live Inspection 1. MOCP RATING NOT MATCHING BREAKERS MFBC 1303 (Outdoor breaker is a max of 25 AMP. There is a 30 AMP in panel.) 2.MOCP RATING NOT MATCHING BREAKERS MFBC 1303( AHU calls for 60 AMP for 10KW. There is a 50 AMP in panel and in unit disconnect.) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL 4. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND( ODU needs to be at least 3" above grade) Above Items were corrected on this inspection
HVAC FINAL 06/19/2020 Disapproved -FEE REQUIRED CPISCITELLI
Note: THIS IS A REINSPECTION Google Duo Live Inspection 1. MOCP RATING NOT MATCHING BREAKERS MFBC 1303 (Outdoor breaker is a max of 25 AMP. There is a 30 AMP in panel.) 2.MOCP RATING NOT MATCHING BREAKERS MFBC 1303( AHU calls for 60 AMP for 10KW. There is a 50 AMP in panel and in unit disconnect.) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL 4. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND( ODU needs to be at least 3" above grade)
HVAC FINAL 04/09/2020 CANCELLED BY APPLICANT CPISCITELLI
Note: Due to covid-19 concerns, inspectors are not entering occupied homes at this time. This type of Inspection has been cancelled until further notice. Additional information will be provided when appropriate. Permit will be extended if necessary.

Review History

Department Status Date In Date Out
MECH COMPLETE 04/02/2020 04/03/2020
Note: Released By: CPISCITELLI

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/09/2020
SURCHARGE FS 533.721 ¤2.00 04/06/2020
SURCHARGE - FS 468.631 ¤2.00 04/06/2020
ADMIN FEE ¤20.00 04/06/2020
INSPECTION 40 ¤40.00 04/06/2020
Fees Total Due: ¤0.00 Total Paid: ¤104.00