Permit #2020040113
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7013-00020-0010 |
| Block: 00020 |
| Subdivision: 2192 - SECTION 13-BELLE TERRE |
| Job Phone: 389-931-8793 |
| Location Address: 89 BRADMORE LN |
| Type: ME - MECHANICAL |
| Issue Date: 04/06/2020 |
| NOC: Unknown |
| Applicant name: OCLES PHILIUS PHILIPPE |
| Owner: ALEXIS MARIE GINETTE |
|
Address 89 BRADMORE LANE PALM COAST, FL 32137 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤3,600.00 |
| Job Description: 2.5 ton ac unit.heat pump ,5 kw and 14 seer |
| Type: CN |
Contractor
A&L SERVICE SYSTEM LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
47 PICKERING DR PALM COAST, FL 32164 |
CAC1818862 (Exp: 08/31/2026) | 389-931-8793 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 07/10/2020 | FINAL APPROVED | CPISCITELLI |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Google Duo Live Inspection 1. MOCP RATING NOT MATCHING BREAKERS MFBC 1303 (Outdoor breaker is a max of 25 AMP. There is a 30 AMP in panel.) 2.MOCP RATING NOT MATCHING BREAKERS MFBC 1303( AHU calls for 60 AMP for 10KW. There is a 50 AMP in panel and in unit disconnect.) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL 4. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND( ODU needs to be at least 3" above grade) Above Items were corrected on this inspection | |||
| HVAC FINAL | 06/19/2020 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: THIS IS A REINSPECTION Google Duo Live Inspection 1. MOCP RATING NOT MATCHING BREAKERS MFBC 1303 (Outdoor breaker is a max of 25 AMP. There is a 30 AMP in panel.) 2.MOCP RATING NOT MATCHING BREAKERS MFBC 1303( AHU calls for 60 AMP for 10KW. There is a 50 AMP in panel and in unit disconnect.) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL 4. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND( ODU needs to be at least 3" above grade) | |||
| HVAC FINAL | 04/09/2020 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: Due to covid-19 concerns, inspectors are not entering occupied homes at this time. This type of Inspection has been cancelled until further notice. Additional information will be provided when appropriate. Permit will be extended if necessary. |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 04/02/2020 | 04/03/2020 |
| Note: Released By: CPISCITELLI |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/09/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/06/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/06/2020 |
| ADMIN FEE | ¤20.00 | 04/06/2020 |
| INSPECTION 40 | ¤40.00 | 04/06/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤104.00 |