I want to search for...
Permit #2020040842
Permit Details
Status: COED
| Parcel Id: 07-11-31-7031-RP11I-0021 |
| Total Square Footage: 1490 sqft |
| Block: RP11I |
| Subdivision: 2166 - SECTION 31-ROYAL PALMS |
| Job Phone: 386-313-6950 |
| Location Address: 1225 ROYAL PALMS PT |
| Type: CA - COMM ADDITION |
| Issue Date: 07/13/2020 |
| NOC: RECORDED |
| Applicant name: MARK ANTHONY LANGELLO |
| Owner: GRACE PRESBYTERIAN CHURCH OF PALM COAST FLORIDA IN |
|
Address 1225 ROYAL PALMS PKWY PALM COAST, FL 32164 |
| Lot: 0021 |
| Contracted Stated Job Value: ¤190,000.00 |
| Job Description: ADDITION -FELLOWSHIP HALL & KITCHEN |
| Type: CN |
Contractor
M & M DEVELOPMENT & CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
2323 N. STATE ST BUNNELL, FL 32110 |
RG291103911 (Exp: 08/31/2023) | 386-313-6950 |
Sub Contractors
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
ROBERT CARLTON LITTLE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3050 EAST MOODY BLVD BUNNELL, FL 32110 |
EC13003740 (Exp: 08/31/2026) | 386-931-1708 |
Inspection History
| Type | Request Date | Result | Inspector |
| STORMWATER FINAL | 03/02/2021 | APPROVED | GBERTOLA |
| Note: EVRETHING IS GOOD | |||
| FINAL SURVEY - OFFICE USE ONLY | 03/02/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: I CAN'T PUT FINAL SURVEY INSPECTION EVRETHING IS GOOD | |||
| ELECTRIC FINAL | 02/18/2021 | APPROVED | JMUNSON |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION APPROVED ELECTRICAL PLAN AND PANEL SCHEDULE DOES NOT SHOW THE ADDITION OF THE 2ND AIR HANDLER AND A/C UNIT, NEED TO REVISE THE ELECTRICAL LOAD CALCULATIONS ALSO SHOWING THE CHANGE TO MAKE SURE THE 125A MAIN BREAKER WILL SUPPORT THE ADDITIONAL LOAD ON BOTH AIR HANDLERS AND A/C UNITS | |||
| BUILDING FINAL | 02/18/2021 | FINAL APPROVED | JBODEN |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 02/18/2021 | APPROVED | JBODEN |
| Note: THIS IS A REINSPECTION | |||
| HVAC FINAL | 02/17/2021 | FINAL APPROVED | CPISCITELLI |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Did not change heat strips to match engineer letter | |||
| HVAC FINAL | 02/08/2021 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: THIS IS A REINSPECTION Did not change heat strips to match engineer letter | |||
| ELECTRIC FINAL | 02/08/2021 | CANCELLED BY APPLICANT | RMARTIN |
| Note: THIS IS A REINSPECTION APPROVED ELECTRICAL PLAN AND PANEL SCHEDULE DOES NOT SHOW THE ADDITION OF THE 2ND AIR HANDLER AND A/C UNIT, NEED TO REVISE THE ELECTRICAL LOAD CALCULATIONS ALSO SHOWING THE CHANGE TO MAKE SURE THE 125A MAIN BREAKER WILL SUPPORT THE ADDITIONAL LOAD ON BOTH AIR HANDLERS AND A/C UNITS | |||
| FIRE FINAL | 02/08/2021 | CANCELLED BY APPLICANT | JBODEN |
| BUILDING FINAL | 02/08/2021 | CANCELLED BY APPLICANT | JBODEN |
| U - UTILITY COMMERCIAL FINAL | 02/08/2021 | FINAL APPROVED | LFITZGERALD |
| LDSC- LANDSCAPE FINAL | 01/20/2021 | FINAL APPROVED | LFITZGERALD |
| ELECTRIC FINAL | 01/20/2021 | Disapproved - NO FEE | RMARTIN |
| Note: APPROVED ELECTRICAL PLAN AND PANEL SCHEDULE DOES NOT SHOW THE ADDITION OF THE 2ND AIR HANDLER AND A/C UNIT, NEED TO REVISE THE ELECTRICAL LOAD CALCULATIONS ALSO SHOWING THE CHANGE TO MAKE SURE THE 125A MAIN BREAKER WILL SUPPORT THE ADDITIONAL LOAD ON BOTH AIR HANDLERS AND A/C UNITS | |||
| PLUMBING FINAL | 01/20/2021 | APPROVED | JGIBSON |
| HVAC FINAL | 01/20/2021 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: Missing volume dampers in fresh air and supply ducts | |||
| BLD - SEWER TIE IN | 01/08/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS WAS FOR GREASE AND SEWER TIE IN TO EXISTING GREASE AND SANITARY SEWER | |||
| ROOF VALLEY & METAL | 10/16/2020 | APPROVED | JBODEN |
| INSULATION | 10/09/2020 | APPROVED | MMESSER |
| LATH/BRICK/WATER BARRIER | 10/09/2020 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION Need Expansion Joint on Gable as per plan and FBC. ADDED INSPECTION PER FOREST | |||
| LATH/BRICK/WATER BARRIER | 10/08/2020 | Disapproved - NO FEE | FWILLIS |
| Note: Need Expansion Joint on Gable as per plan and FBC. | |||
| ELECTRIC 1ST ROUGH | 10/06/2020 | CANCELLED BY INSPECTOR | JMUNSON |
| Note: Not needed. Needs to call in 2nd rough | |||
| ELECTRIC 2ND ROUGH | 10/06/2020 | APPROVED | JMUNSON |
| HVAC ROUGH | 10/06/2020 | APPROVED | JBODEN |
| PLUMBING 2ND ROUGH | 10/06/2020 | APPROVED | JGIBSON |
| ALL ROUGH | 10/06/2020 | CANCELLED BY INSPECTOR | JBODEN |
| ABOVE CEILING | 10/06/2020 | APPROVED - AS NOTED | JBODEN |
| FOUND SURVEY APPROVED (OFFICE) | 09/22/2020 | APPROVED | DRAMIREZ |
| ROOF SHEATHING / BRACE / TIE DOWN | 08/28/2020 | APPROVED | MMESSER |
| Note: Remainder of work from partial ready | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 08/24/2020 | PARTIALLY APPROVED | FWILLIS |
| Note: Partial PARTIAL ROOFING ONLY SO CONTRACTOR CAN DRY-IN. STILL NEEDS BRACES, TIE DOWNS ETC. | |||
| LINTEL | 08/14/2020 | APPROVED | MMESSER |
| Note: Please do inspection after 10 am | |||
| MONOLITHIC SLAB | 08/11/2020 | APPROVED | MMESSER |
| Note: After 11:00 am if possible. Thank you. | |||
| PLUMBING 1ST ROUGH | 08/05/2020 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/24/2021 | 02/26/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| PLENG | COMPLETE | 02/24/2021 | 02/26/2021 |
| Note: Released By: DENNIS LEAP - - DLEAP@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 02/22/2021 | 02/22/2021 |
| Note: Held By: LIBBY MUSGROVE - - lmusgrove@ci.palm-coast.fl.us Documents/Files named incorrectly Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf record retention accuracy. Please do not add anything to the file names | |||
| BADMIN | COMPLETE | 02/22/2021 | 02/22/2021 |
| Note: Released By: LIBBY MUSGROVE - - lmusgrove@ci.palm-coast.fl.us | |||
| ELEC | COMPLETE | 02/05/2021 | 02/05/2021 |
| Note: Released By: JMUNSON | |||
| DSD | COMPLETE | 09/21/2020 | 09/21/2020 |
| Note: Released By: DRAMIREZ | |||
| BLD | COMPLETE | 09/04/2020 | 09/21/2020 |
| Note: Released By: PBUCKLEY | |||
| PLENG | COMPLETE | 09/04/2020 | 09/08/2020 |
| Note: Released By: DLEAP | |||
| BLD | COMPLETE | 07/28/2020 | 08/11/2020 |
| Note: Released By: FREODICA Revision: moved slab 2 ft norh to align with existing bldg. | |||
| DSD | HOLD | 07/28/2020 | 07/28/2020 |
| Note: Held By: JGONZALEZ Provide a revised site plan showing the relocation of the pad with it setbacks and dimensions. | |||
| ELEC | COMPLETE | 07/08/2020 | 07/09/2020 |
| Note: Released By: JMUNSON | |||
| MECH | COMPLETE | 07/02/2020 | 07/06/2020 |
| Note: Released By: CPISCITELLI | |||
| ELEC | HOLD | 07/02/2020 | 07/07/2020 |
| Note: Held By: JMUNSON Load calcs done at the wrong volt amp. NEC 2014 art 220 | |||
| ELEC | HOLD | 06/17/2020 | 06/23/2020 |
| Note: Held By: JMUNSON 1. Show what size the existing service is. 2. Need show load calculations showing that the existing service can accommodate the new panel and its load. 2nd Request | |||
| MECH | HOLD | 06/17/2020 | 06/18/2020 |
| Note: Held By: CPISCITELLI 1. Provide energy calcs showing equipment info on the summary short form. 2.. Provide Duct Drawing showing supply, return ans fresh air and ventilation. 3. Provide Manufacturers instructions for Warming Cabinet | |||
| FI1 | COMPLETE | 06/17/2020 | 06/30/2020 |
| Note: Released By: WMILLER | |||
| PLUM | COMPLETE | 06/17/2020 | 06/22/2020 |
| Note: Released By: PBUCKLEY | |||
| BLD | COMPLETE | 06/17/2020 | 06/22/2020 |
| Note: Released By: PBUCKLEY | |||
| BADMIN | COMPLETE | 06/17/2020 | 06/17/2020 |
| Note: Released By: LMUSGROVE | |||
| ARCHR | COMPLETE | 06/17/2020 | 06/17/2020 |
| Note: Released By: BDAWSON | |||
| ARCHR | COMPLETE | 04/23/2020 | 05/05/2020 |
| Note: Released By: BDAWSON | |||
| BLD | HOLD | 04/23/2020 | 05/08/2020 |
| Note: Held By: FREODICA 1.Sheet LS: a. Identify the type of construction on the Code Analysis if it is Type IIIA or Type IIIB per FBC 6th Edition Table 601. b. Provide the total occupant load and total square footage of the new fellowship hall and existing adjacent church. This is required to determine if a fire sprinkler system is required per Section 903.2.1.3. If the intent is to not provide a fire sprinkler system throughout the church and fellowship hall, see comment a. below under Sheet A2a comments. c. Provide plumbing fixture calculations per Section 2902.1.1 and Table 2902.1 for both the church and fellowship hall in order to determine if fixtures in the fellowship hall in addition to those in the church provide sufficient fixtures for the new occupant load. d. Provide ASTM E119 or UL 263 2-hour fire-resistance rating of exterior walls to indicate compliance with FBC 6th Edition Section 602.3 and Table 601 as described in Section 703.3. You can use any of the six listed methods or procedures to determine the 2- hour fire-resistance rating. If referencing ASTM E119 or UL 263 provide complete listings. If providing designs from documented approved sources provide complete design details and references. 2. Sheet A2: a. Provide 2-hr fire resistance-rated fire barrier between new fellowship hall and existing adjacent church to create separate fire areas per FBC 6th Edition Table 601/707.3.10 and Table 707.3.10. b. Provide 2--hr fire-rated wall detail (fire barrier)per FBC 6th Edition Sec. 721/722 c. Provide automatic fire sprinkler system per FBC 6th Edition Sec. 903.2.1 depending on fire area and occupant load as mentioned above (LS b comment). 3. Provide Product approval for roofing material, underlayment, exterior windows and door, soffits, structural components such as wood connectors, wood anchors, truss plates and Administrative Code 9B-72. FReodica-386-986-4734 | |||
| DSD | COMPLETE | 04/23/2020 | 04/24/2020 |
| Note: Released By: JGONZALEZ | |||
| ELEC | HOLD | 04/23/2020 | 04/28/2020 |
| Note: Held By: JMUNSON 1. Submit electrical plans. 2. Load Calcs to show new addition | |||
| FI1 | HOLD | 04/23/2020 | 05/07/2020 |
| Note: Held By: WMILLER The combined occupant load of the existing building and addition will exceed the maximum threshold for fire sprinklers and alarms, and will need protection and notification under the provisions of [F] 903.2.1.3, [F] 907.2.1. Group A-3 or a fire barrier consistent with FBC 2017 707.3.10 and Table 707.3.10 | |||
| MECH | HOLD | 04/23/2020 | 05/01/2020 |
| Note: Held By: CPISCITELLI Submit Mechanical drawings and energy calcs for addition | |||
| PLUM | HOLD | 04/23/2020 | 05/07/2020 |
| Note: Held By: FREODICA 1. Provide total occupant load of existing chapel and new fellowship hall to determine the required plumbing fixures for male and female such as water closet, urinal, lavatories (drinking fountain and service sink per FBCP 6th edition, sec. 403. 2. Provide sanitary, and domestic water (hot and cold) riser diagrams for the fellowship hall based item 1 above comment per FBC 6th ed. sec. 107.2.1. FReodica -386-986-4734 | |||
| UD1 | COMPLETE | 04/23/2020 | 04/24/2020 |
| Note: Released By: CJOHNSON |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 02/19/2021 |
| REINSPECTION FEE | ¤40.00 | 02/19/2021 |
| REVISION | ¤40.00 | 02/19/2021 |
| SITE PLAN 20 | ¤20.00 | 07/13/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/13/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/13/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤99.50) | 07/13/2020 |
| ADMIN COMMERCIAL | ¤60.00 | 07/13/2020 |
| INSPECTION - COMMERCIAL ADD | ¤1,330.00 | 07/13/2020 |
| BUILDING DISCOUNT 100% | (¤2,130.50) | 07/13/2020 |
| ELECTRIC FEE | ¤174.00 | 07/13/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤12.74) | 07/13/2020 |
| IMPACT FEE FIRE | ¤424.80 | 07/13/2020 |
| IMPACT FEE TRANSPORTATION | ¤3,316.50 | 07/13/2020 |
| MECHANICAL FEE | ¤174.00 | 07/13/2020 |
| PLAN CHECK FEE | ¤218.50 | 07/13/2020 |
| PLUMBING FEE | ¤174.00 | 07/13/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤3,773.06 |