Status: FINAL
| Parcel Id: 07-11-31-7065-00610-0060 |
| Total Square Footage: 2507 sqft |
| Block: 00610 |
| Subdivision: 0 - |
| Job Phone: 386-427-1665 |
| Location Address: 21 KARAS TR |
| Type: ME - MECHANICAL |
| Issue Date: 05/22/2020 |
| NOC: Unknown |
| Applicant name: BRANDON W GRANGER |
| Owner: SIMPSON KIMBERLY P & DAVID C W&H |
|
Address 2820 CORAL STREET CORONA, CA 92882 |
|
Address LIFE ESTATE CORONA, CA 92882 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤3,900.00 |
| Job Description: Installing 2.5 ton 14 seer replacement a/c system |
| Type: CN |
Contractor
ADVANCED AIR & HEAT OF FLORIDA, LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
1939 W PARK AVE EDGEWATER, FL 32141 |
CAC1817470 (Exp: 08/31/2020) | 386-427-1665 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 08/18/2020 | FINAL APPROVED | CPISCITELLI |
| Note: THIS IS A REINSPECTION 1. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND (unit at grade level. Needs to be 3" above grade) 2. GARAGE CEILING AND WALL, HOLES MUST BE SEALED R302.5, 302.5.2, 302.5.3, 302.6, OPENINGS AND PENITRATIONS THROUGH GARAGE WALLS OR CEILINGS NOT ALLOWED. ( Ceiling around plenum in garage needs to be sealed) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL. ( Drain outside needs to drain 12 inches off house) Above items were corrected on this inspection | |||
| HVAC FINAL | 07/23/2020 | Disapproved -FEE REQUIRED | CPISCITELLI |
| Note: 1. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND (unit at grade level. Needs to be 3" above grade) 2. GARAGE CEILING AND WALL, HOLES MUST BE SEALED R302.5, 302.5.2, 302.5.3, 302.6, OPENINGS AND PENITRATIONS THROUGH GARAGE WALLS OR CEILINGS NOT ALLOWED. ( Ceiling around plenum in garage needs to be sealed) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL. ( Drain outside needs to drain 12 inches off house) |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/22/2020 | 05/22/2020 |
| Note: Released By: CPISCITELLI |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 07/23/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/22/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/22/2020 |
| ADMIN FEE | ¤20.00 | 05/22/2020 |
| INSPECTION 40 | ¤40.00 | 05/22/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤104.00 |