Permit #2020051052

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7065-00610-0060
Total Square Footage: 2507 sqft
Block: 00610
Subdivision: 0 -
Job Phone: 386-427-1665
Location Address: 21 KARAS TR
Type: ME - MECHANICAL
Issue Date: 05/22/2020
NOC: Unknown
Applicant name: BRANDON W GRANGER
Owner: SIMPSON KIMBERLY P & DAVID C W&H

Address

2820 CORAL STREET

CORONA, CA 92882

Address

LIFE ESTATE

CORONA, CA 92882

Lot: 0060
Contracted Stated Job Value: ¤3,900.00
Job Description: Installing 2.5 ton 14 seer replacement a/c system
Type: CN

Contractor

ADVANCED AIR & HEAT OF FLORIDA, LLC
Status Location Address State License Number Phone
CANCEL

1939 W PARK AVE

EDGEWATER, FL 32141

CAC1817470 (Exp: 08/31/2020) 386-427-1665

Inspection History

Type Request Date Result Inspector
HVAC FINAL 08/18/2020 FINAL APPROVED CPISCITELLI
Note: THIS IS A REINSPECTION 1. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND (unit at grade level. Needs to be 3" above grade) 2. GARAGE CEILING AND WALL, HOLES MUST BE SEALED R302.5, 302.5.2, 302.5.3, 302.6, OPENINGS AND PENITRATIONS THROUGH GARAGE WALLS OR CEILINGS NOT ALLOWED. ( Ceiling around plenum in garage needs to be sealed) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL. ( Drain outside needs to drain 12 inches off house) Above items were corrected on this inspection
HVAC FINAL 07/23/2020 Disapproved -FEE REQUIRED CPISCITELLI
Note: 1. 3 inches ABOVE THE GROUND FBC, R, M1305.1.4.1 AND FIRMLY SUPPORTED ON A CONCRETE PAD OR OTHER APPROVED MATERIAL EXTENDING NOT LESS THAN 3inches ABOVE THE ADJOINING GROUND (unit at grade level. Needs to be 3" above grade) 2. GARAGE CEILING AND WALL, HOLES MUST BE SEALED R302.5, 302.5.2, 302.5.3, 302.6, OPENINGS AND PENITRATIONS THROUGH GARAGE WALLS OR CEILINGS NOT ALLOWED. ( Ceiling around plenum in garage needs to be sealed) 3. CONDENSATE DRAIN R318.5 PROTECTION AGAINST DECAY AND TRERMITES, MUST DISCHARGE AT LEAST 1FT- AWAY FROM STRUCTURE SIDEWALL. ( Drain outside needs to drain 12 inches off house)

Review History

Department Status Date In Date Out
MECH COMPLETE 05/22/2020 05/22/2020
Note: Released By: CPISCITELLI

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 07/23/2020
SURCHARGE FS 533.721 ¤2.00 05/22/2020
SURCHARGE - FS 468.631 ¤2.00 05/22/2020
ADMIN FEE ¤20.00 05/22/2020
INSPECTION 40 ¤40.00 05/22/2020
Fees Total Due: ¤0.00 Total Paid: ¤104.00