Status: FINAL

Parcel Id: 07-11-31-7031-00400-0090
CONDITIONED SPACE: 184 sqft
Total Square Footage: 184 sqft
Block: 00400
Subdivision: 2166 - SECTION 31-ROYAL PALMS
Job Phone: 386-263-8272
Location Address: 31 RICHMOND DR
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 01/22/2021
NOC: RECORDED
Applicant name: ROY CHARLES WALDHAUER
Owner: CAGGIANO, VINCENT J & KATHRYN A

Address

UNIT 200 STE 130

PALM COAST, FL 32164

Address

800 BELLE TERRE PKWY

PALM COAST, FL 32164

Lot: 0090
Contracted Stated Job Value: ¤12,800.00
Job Description: Sun Room, enclose lanai
Type: CN

Contractor

BY THE SHORE INC.
Status Location Address State License Number Phone Fax
ACTIVE

1600 N STATE STREET # 102

,

CRC1327300 (Exp: 08/31/2026) 386-263-8272 386-263-8289

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/12/2021 FINAL APPROVED MMESSER
ALL ROUGH 01/25/2021 APPROVED MMESSER

Review History

Department Status Date In Date Out
BADMIN HOLD 09/10/2020 09/10/2020
Note: Held By: LMUSGROVE NEED SUBS LISTED
BADMIN COMPLETE 09/10/2020 09/10/2020
Note: Released By: MDEFREITAS added elect sub
BLD COMPLETE 09/01/2020 09/09/2020
Note: Released By: FREODICA
MECH COMPLETE 07/28/2020 07/31/2020
Note: Released By: CPISCITELLI
BLD HOLD 07/28/2020 08/04/2020
Note: Held By: FREODICA Repeat comments item 1 and 2: 1. The proposed sunroom does not meet the minimum required 65 percent glazing of the total area of windows and door to the total area of the walls of a longer wall and one(1) short wall at the theight of 6 ft 8 inches from the floor. Please see the definition of a sunroom per FBCR 6th Edition. . 2. Identify the sunroom category after complying witn item 1 above per FBCR 6th edition sec.R301,2,1,1,1, It appears the space is Category V due to an opening to the main structure. Please clarify per FBC 6th ed. sec. 107.2.1. Notes: 1. Please see the definition of a Sunroom per FBCR 6th Edition. 2. The revised plan indicates Category II which does not apply until completing hold item 1 above. FReodica-386-986-4734.
ELEC COMPLETE 06/22/2020 06/23/2020
Note: Released By: JMUNSON
MECH HOLD 06/22/2020 06/24/2020
Note: Held By: CPISCITELLI Clarify existing opening. Is it a door/ window or pass through. (Second Request) If it is a pass through then the sunroom can not be classified as a class 2 sunroom
BLD HOLD 06/22/2020 06/29/2020
Note: Held By: FREODICA Repeat comments: 1, The proposed sunroom does not meet the minimum required 65 percent glazing of the total area of windows and door to the total area of the walls of a longer wall and one(1) short wall at the theight of 6 ft 8 inches from the floor. Please see the defination of a sunroom per FBCR 6th Edition. . 2.Identify the sunroom category after complying witn item 1 above per FBCR 6th edition sec.R301,2,1,1,1, It appears the space is Category V due to an opening to the main structure. Please clarify per FBC 6th ed. sec. 107.2.1. 3. Identify the adjacent space to dermine that the proposed sunroom does not block the means of egress such as a bedroom for clarification per FBC 6th ed. sec. 107.2.1. Note: Please see the definition of a Sunroom on FBCR 6th Edition. FReodica-386-986-4734.
BADMIN HOLD 06/22/2020 06/22/2020
Note: Held By: STHOMAS 6-22-20 1. RENAME TO REV PLANS.PDF
BADMIN COMPLETE 06/22/2020 06/22/2020
Note: Released By: STHOMAS
ELEC HOLD 06/03/2020 06/03/2020
Note: Held By: JMUNSON 1. Need to have correct outlet spacing. NEC 2014 art 210.52 (A) 2. Room needs to be protected by an Arc Fault breaker. NEC 2014 art 210.12 3. List all sub contractors
MECH HOLD 06/03/2020 06/04/2020
Note: Held By: CPISCITELLI Put on Hold at applicant request so revised plans can be uploaded
BLD HOLD 06/03/2020 06/04/2020
Note: Held By: CPISCITELLI Put on Hold at applicant request so revised plans can be uploaded
BLD HOLD 05/27/2020 06/01/2020
Note: Held By: FREODICA 1, The proposed sunroom does not meet the minimum required 65 percent glazing of the total area of windows and door to the total area of the walls of a longer wall and one(1) short wall at the theight of 6 ft 8 inches from the floor. Please see the defination of a sunroom per FBCR 6th Edition. . 2.Identify the sunroom category after complying witn item 1 above per FBCR 6th edition sec.R301,2,1,1,1, It appears the space is Category V due to an opening to the main structure. Please clarify per FBC 6th ed. sec. 107.2.1. 3. Identify the adjacent space to dermine that the proposed sunroom does not block the means of egress such as a bedroom for clarification per FBC 6th ed. sec. 107.2.1. FReodica-386-986-4734.
ELEC HOLD 05/27/2020 05/28/2020
Note: Held By: JMUNSON 1. Need to have correct outlet spacing. NEC 2014 art 210.52 (A) 2. Room needs to be protected by an Arc Fault breaker. NEC 2014 art 210.12 3. List all sub contractors
MECH HOLD 05/27/2020 05/29/2020
Note: Held By: CPISCITELLI 1. Provide code analysis with classification of sun room R301.2.1.1.1 FBC Residential 2017 6Th edition. 2. Clarify existing opening. Is it a door/ window or pass through.
PLUM CANCEL 05/27/2020 06/01/2020
ZON COMPLETE 05/27/2020 05/27/2020
Note: Released By: AMOBLEY

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 01/22/2021
BUILDING DISCOUNT 100% (¤361.80) 01/22/2021
ELECTRIC FEE ¤72.60 01/22/2021
MECHANICAL FEE ¤72.60 01/22/2021
PLAN CHECK FEE ¤40.00 01/22/2021
PLUMBING FEE ¤72.60 01/22/2021
REMODEL/ADDITION/ACCES INSPECT ¤84.00 01/22/2021
SITE PLAN 20 ¤20.00 01/22/2021
SURCHARGE FS 533.721 ¤2.00 01/22/2021
SURCHARGE - FS 468.631 ¤2.00 01/22/2021
Fees Total Due: ¤0.00 Total Paid: ¤24.00