Permit #2020060023
Permit Details
Status: COED
| Parcel Id: 07-11-31-7057-00400-0020 |
| CONDITIONED SPACE: 1775 sqft |
| CONDITIONED SPACE: 2300 sqft |
| GARAGE: 680 sqft |
| OPENED PORCH (WITH ROOF) : 191 sqft |
| Total Square Footage: 4946 sqft |
| Block: 00400 |
| Subdivision: 2123 - SECTION 57-ULYSSES TREES |
| Job Phone: 904-268-7730 |
| Location Address: 12 UPSHIRE PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/05/2020 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: MARONDA HOMES INC |
|
Address 5220 SHAD RD STE 202 JACKSONVILLE, FL 32257 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4005 MARONDA WAY , |
CRC056762 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| CANCEL |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2022) | 877-906-1113 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
ANDREW SCOTT DIGAETANO JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
44 FORT CAROLINE PALM COAST, FL 32137 |
CCC1331606 (Exp: 08/31/2026) | 386-302-9063 |
MICHAEL LEE RAFFENSBERGER
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
7725 SANDSCOVE CT WINTER PARK, FL 32792 |
CAC1819723 (Exp: 08/31/2024) | 407-629-6920 | 407-629-9307 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/03/2020 | FINAL APPROVED | WMILLER |
| U -UTILITY RESIDENTIAL FINAL | 12/03/2020 | FINAL APPROVED | JHARDING |
| ROW - FINAL APRON (AFTER POUR) | 12/02/2020 | APPROVED - AS NOTED | KRUTH |
| Note: 12/2/2020 THE SWALE AREA ACROSS THE STREET IS BEING TAKEN CARE OF BY THE CITY DAMAGE WAS DONE BY THE CITY UTILITY DEPARTMENT SPOKE WITH HOLLY AND CORRECTIONS ARE MADE | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/02/2020 | APPROVED - AS NOTED | KRUTH |
| Note: THIS IS A REINSPECTION THE SWALE ON THE RIGHT SIDE OF THE PIPE IS TO LOW BRING UP AND RE SOD ALSO THERE ARE RUTS IN THE SWALE ON THE LEFT SIDE OF THE PIPE THAT NEEDS TO BE FIXED AND SOD ADDED THERE AND THERE ARE RUTS ACROSS THE STREET THAT NEEDS TO BE FIXED AND SOD ADDED AND ASPHAULT PACH NEEDS TO BE DONE BEFORE YOU WILL PASS YOUR ROW STORMWATER FINAL ALL OF THE DIRT IN THE SWALES NEED TO BE REMOVED AS WELL CORRECTIONS MADE 12/2/2020 | |||
| ROW - STORMWATER FINAL | 12/02/2020 | APPROVED - AS NOTED | KRUTH |
| Note: SWALE ACROSS THE STREET ARE BEING REPAIRED BY THE CITY UTILITY DEPARTMENT | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/30/2020 | Disapproved -FEE REQUIRED | KRUTH |
| Note: THE SWALE ON THE RIGHT SIDE OF THE PIPE IS TO LOW BRING UP AND RE SOD ALSO THERE ARE RUTS IN THE SWALE ON THE LEFT SIDE OF THE PIPE THAT NEEDS TO BE FIXED AND SOD ADDED THERE AND THERE ARE RUTS ACROSS THE STREET THAT NEEDS TO BE FIXED AND SOD ADDED AND ASPHAULT PACH NEEDS TO BE DONE BEFORE YOU WILL PASS YOUR ROW STORMWATER FINAL ALL OF THE DIRT IN THE SWALES NEED TO BE REMOVED AS WELL PIPES NEED TO BE CLEANED OUT TOO | |||
| FINAL SURVEY (OFFICE USE ONLY) | 11/30/2020 | APPROVED | KRUTH |
| U - SEWER TIE IN | 11/12/2020 | APPROVED - AS NOTED | JGIBSON |
| Note: UTILITY COMPANY MADE TAP | |||
| U-CROSS CONNECTION | 11/12/2020 | APPROVED - AS NOTED | JHARDING |
| Note: this house does not have irrigation system. Approved no cross connections | |||
| ELECTRIC - EARLY POWER | 10/28/2020 | APPROVED - AS NOTED | JMUNSON |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION 1.Both main breakers need to be installed. 2. breaker openings in the meter main need to be filled NEC 2014 110.12 (A). 3. Riser diagram on plans need to match whats installed. 10/21/20 1. Breaker openiungs need to be filled in meter main. NEC 2014 110.12. 2. Riser diagram on plans needs to match whats installed. 10/27/20 Tape is not UL listed for breaker blanks. NEC 110.3. Breakers openings need to be filled by UL listed breaker blanks. NEC 2014 110. 12 10/28/20 Emailed FPL at 8:40 am | |||
| ELECTRIC - EARLY POWER | 10/27/2020 | Disapproved -FEE REQUIRED | JMUNSON |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1.Both main breakers need to be installed. 2. breaker openings in the meter main need to be filled NEC 2014 110.12 (A). 3. Riser diagram on plans need to match whats installed. 10/21/20 1. Breaker openiungs need to be filled in meter main. NEC 2014 110.12. 2. Riser diagram on plans needs to match whats installed. 10/27/20 Tape is not UL listed for breaker blanks. NEC 110.3. Breakers openings need to be filled by UL listed breaker blanks. NEC 2014 110. 12 | |||
| ELECTRIC - EARLY POWER | 10/21/2020 | Disapproved -FEE REQUIRED | JMUNSON |
| Note: THIS IS A REINSPECTION 1.Both main breakers need to be installed. 2. breaker openings in the meter main need to be filled NEC 2014 110.12 (A). 3. Riser diagram on plans need to match whats installed. 10/21/20 1. Breaker openiungs need to be filled in meter main. NEC 2014 110.12. 2. Riser diagram on plans needs to match whats installed. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/16/2020 | APPROVED - AS NOTED | KHOWELL |
| Note: It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist READY TO POUR upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/15/2020 | Disapproved -FEE REQUIRED | KHOWELL |
| Note: * DIG FOOTERS OUT TO MINIMUM 6" DEEP * CULVERT PIPE IS REQUIRED TO BE HALF EXPOSED ON EACH SIDE PER CITY STANDARD DETAIL. * 5" MINIMUM THICK CONCRETE REQUIRED IN THE ROW. * FOOTER REBAR NOT ON SITE. * HIGH AREAS IN PAD 5" IN ROW AND 4" ABOVE THE ROW ARE THE MINIMUM REQUIREMENTS. * WATER IN CULVERT PIPE AT TIME OF INSPECTION. | |||
| ELECTRIC - EARLY POWER | 10/15/2020 | Disapproved - NO FEE | JMUNSON |
| Note: 1.Both main breakers need to be installed. 2. breaker openings in the meter main need to be filled NEC 2014 110.12 (A). 3. Riser diagram on plans need to match whats installed. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/14/2020 | CANCELLED BY APPLICANT | KHOWELL |
| Note: HOLLY CALLED AND CANCELLED | |||
| LATH/BRICK/ WATER BARRIER | 09/21/2020 | APPROVED | FWILLIS |
| INSULATION | 08/31/2020 | APPROVED | FWILLIS |
| ALL ROUGH | 08/26/2020 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 08/17/2020 | APPROVED - AS NOTED | FWILLIS |
| Note: Roof Valley Metal Inspection Passes.......However while performing this Inspection it was noticed that the Wall Sheathing was not secured properly left rear corner and in the rear of house. Would like to see those areas in question on next Inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/10/2020 | APPROVED | JBODEN |
| FOUND SURVEY APPROVED (OFFICE) | 08/04/2020 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 07/31/2020 | APPROVED | JBODEN |
| Note: Spoke to Robert inspection will be before 9. Thank you. | |||
| TIE BEAM / LINTEL | 07/30/2020 | CANCELLED BY APPLICANT | FWILLIS |
| Note: After Hours Inspection will be needed | |||
| MONOLITHIC SLAB | 07/24/2020 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION Exterior Footings Should be placed NOT LESS than 12" below the UNDISTURBED GROUND SURFACE. 7/22/20 -2017 RESIDENTIAL CODE, R403.1.4 SAYS FOOTINGS SHOULD BE PLACED NOT LESS THAN 12" BELOW UNDISTURBED GROUND SURFACE. PUSHING NON-COMPACTED DIRT TO THE TOP OF THE BATTER BOARDS IS NOT PART OF THE UNDISTURBED GROUND. THIS GOES FOR THE FRONT ENTRY ALSO. 7/24/20 - Corrected Footer Depth on house. | |||
| MONOLITHIC SLAB | 07/23/2020 | CANCELLED BY APPLICANT | FWILLIS |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Exterior Footings Should be placed NOT LESS than 12" below the UNDISTURBED GROUND SURFACE. 7/22/20 -2017 RESIDENTIAL CODE, R403.1.4 SAYS FOOTINGS SHOULD BE PLACED NOT LESS THAN 12" BELOW UNDISTURBED GROUND SURFACE. PUSHING NON-COMPACTED DIRT TO THE TOP OF THE BATTER BOARDS IS NOT PART OF THE UNDISTURBED GROUND. THIS GOES FOR THE FRONT ENTRY ALSO. | |||
| MONOLITHIC SLAB | 07/22/2020 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: THIS IS A REINSPECTION Exterior Footings Should be placed NOT LESS than 12" below the UNDISTURBED GROUND SURFACE. 7/22/20 -2017 RESIDENTIAL CODE, R403.1.4 SAYS FOOTINGS SHOULD BE PLACED NOT LESS THAN 12" BELOW UNDISTURBED GROUND SURFACE. PUSHING NON-COMPACTED DIRT TO THE TOP OF THE BATTER BOARDS IS NOT PART OF THE UNDISTURBED GROUND. THIS GOES FOR THE FRONT ENTRY ALSO. | |||
| MONOLITHIC SLAB | 07/20/2020 | Disapproved - NO FEE | FWILLIS |
| Note: Exterior Footings Should be placed NOT LESS than 12" below the UNDISTURBED GROUND SURFACE. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 07/16/2020 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 07/16/2020 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 06/19/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 10/23/2020 | 10/26/2020 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 08/03/2020 | 08/04/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 08/03/2020 | 08/03/2020 |
| Note: Released By: AMOBLEY | |||
| ELEC | COMPLETE | 06/04/2020 | 06/04/2020 |
| Note: Released By: JMUNSON | |||
| ZON | COMPLETE | 06/04/2020 | 06/04/2020 |
| Note: Released By: ELENS | |||
| BLD | COMPLETE | 06/01/2020 | 06/03/2020 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 06/01/2020 | 06/01/2020 |
| Note: Released By: HHAND | |||
| ELEC | HOLD | 06/01/2020 | 06/01/2020 |
| Note: Held By: JMUNSON Riser diagram only shows 150 and 200 amp service. Load calculations say recommended service 300 amp minimum of 200 amp you need to specify which one is being used and if its a 300 amp service riser diagram needs to be uploaded for that. | |||
| ENGIN1 | COMPLETE | 06/01/2020 | 06/01/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 06/01/2020 | 06/03/2020 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 06/01/2020 | 06/02/2020 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 06/01/2020 | 06/03/2020 |
| Note: Released By: JPI | |||
| SW1 | COMPLETE | 06/01/2020 | 06/01/2020 |
| Note: Released By: CTROHA | |||
| UTL | COMPLETE | 06/01/2020 | 06/03/2020 |
| Note: Released By: AHALL | |||
| ZON | HOLD | 06/01/2020 | 06/01/2020 |
| Note: Held By: ELENS Please correct the legal description on the site plan and survey. It is lot 2, not lot 1. Please provide the color of both the siding and the stucco finish to demonstrate that the exterior is one color. | |||
| SWALE | COMPLETE | 06/01/2020 | 06/30/2020 |
| Note: Released By: TBAKER |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 12/04/2020 |
| REINSPECTION FEE | ¤40.00 | 12/04/2020 |
| REINSPECTION FEE | ¤40.00 | 12/04/2020 |
| REINSPECTION FEE | ¤40.00 | 12/04/2020 |
| REINSPECTION FEE | ¤40.00 | 12/04/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤974.00 | 06/05/2020 |
| SITE PLAN 20 | ¤20.00 | 06/05/2020 |
| SURCHARGE FS 533.721 | ¤20.71 | 06/05/2020 |
| SURCHARGE - FS 468.631 | ¤31.06 | 06/05/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/05/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 06/05/2020 |
| SEWER CREDIT | (¤850.00) | 06/05/2020 |
| SEWER INSPECTION | ¤25.00 | 06/05/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 06/05/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 06/05/2020 |
| METER - DEPOSIT | ¤60.00 | 06/05/2020 |
| WATER- TURN ON | ¤25.00 | 06/05/2020 |
| ADMIN FEE | ¤20.00 | 06/05/2020 |
| CONNECTION FEES | ¤1,002.88 | 06/05/2020 |
| ELECTRIC FEE | ¤352.20 | 06/05/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 06/05/2020 |
| IMPACT FEE FIRE | ¤223.38 | 06/05/2020 |
| IMPACT FEE PARKS | ¤849.24 | 06/05/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 06/05/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 06/05/2020 |
| MECHANICAL FEE | ¤352.20 | 06/05/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/05/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 06/05/2020 |
| PLAN CHECK FEE | ¤194.80 | 06/05/2020 |
| PLUMBING FEE | ¤352.20 | 06/05/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,119.52 |