Permit #2020060558

Permit Details

Status: COED

Parcel Id: 07-11-31-7029-00450-0090
CONDITIONED SPACE: 1646 sqft
GARAGE: 414 sqft
OPENED PORCH (WITH ROOF) : 36 sqft
OPENED PORCH (WITH ROOF) : 177 sqft
Total Square Footage: 2273 sqft
Block: 00450
Subdivision: 2209 - SECTION 29-ROYAL PALMS
Job Phone: 386-447-7007
Location Address: 7 RYBERRY PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/31/2020
NOC: RECORDED
Applicant name: MAXIM TARANNIK
Owner: GOLDEN MAGNOLIA INC

Address

1 ROCKEFELLER DRIVE

PALM COAST, FL 32164

Lot: 0090
Contracted Stated Job Value: ¤220,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLDEN MAGNOLIA, INC
Status Location Address State License Number Phone
INACTIVE

1 ROCKEFELLER DRIVE

PALM COAST, FL 32164

RR282811984 (Exp: 08/31/2025) 386-447-7007

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
FERNANDO MEZA SR
Status Location Address State License Number Phone
CANCEL

457 CHELSEA PLACE AV

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2022) 570-575-8139

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/27/2021 FINAL APPROVED JWALKER
Note: THIS IS A REINSPECTION No approved prints on site no energy calulations. Missing insulation placard. Unable to test smoke due to dust covers still in place Closet door in tub unable to test. No cooking appliance. The range circut braker installed is 35 amp minimum of 4O required. However unable to confirm size necessary due to missing prints.
BLD - BUILDING FINAL 09/23/2021 Disapproved -FEE REQUIRED JWALKER
Note: No approved prints on site no energy calulations. Missing insulation placard. Unable to test smoke due to dust covers still in place Closet door in tub unable to test. No cooking appliance. The range circut braker installed is 35 amp minimum of 4O required. However unable to confirm size necessary due to missing prints. Cut out dry wall and insulation in kitchen .
BLD - BUILDING FINAL 09/15/2021 CANCELLED BY APPLICANT WEB
ROW - FINAL APRON (AFTER POUR) 09/13/2021 APPROVED RGROSS
ROW - STORMWATER FINAL 09/13/2021 APPROVED RGROSS
Note: LEFT FRONT SWALE HAS SOME SPOTS THAT ARE HIGHER. THEY NEED TO LOWER THOSE SPOT. THE LEFT SIDE OF THE HOUSE HAS SOME PIECES OF SOD THAT NEED TO FIXED. THEY ARE BLOCKING THE WATER FLOW I ALSO SPRAY PAINTED THE AREA IN PINK
U -UTILITY RESIDENTIAL FINAL 09/13/2021 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 09/10/2021 APPROVED - AS NOTED GBERTOLA
Note: LEFT FRONT SWALE HAS SOME SPOTS THAT ARE HIGHER. THEY NEED TO LOWER THOSE SPOT. THE LEFT SIDE OF THE HOUSE HAS SOME PIECES OF SOD THAT NEED TO FIXED. THEY ARE BLOCKING THE WATER FLOW I ALSO SPRAY PAINTED THE AREA IN PINK
FINAL SURVEY (OFFICE USE ONLY) 09/10/2021 APPROVED GBERTOLA
U-CROSS CONNECTION 09/02/2021 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
U-CROSS CONNECTION 09/01/2021 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 08/19/2021 APPROVED - AS NOTED GBERTOLA
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Mitered ends NO EQUALS. Top of mitered board ends must be a miminum of 18 inches from the side of the culvert. RIGHT SIDE IS 15 INCHES CHECK THAT THERE IS AT LEAST 18 INCHES FROM EACH SIDE OF THE PIPE TO THE FORM BOARD AT THE TOP OF THE DRIVEWAY SHOULDER CULVERT PIPE IS GOOD culvert pipe is lower then other driveway 2/10 and half i will contac stormwater engineers 08/19/2021=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING.
ROW- PRE-APRON (PRE-POUR) 08/18/2021 Disapproved - NO FEE GBERTOLA
Note: THIS IS A REINSPECTION Mitered ends NO EQUALS. Top of mitered board ends must be a miminum of 18 inches from the side of the culvert. RIGHT SIDE IS 15 INCHES CHECK THAT THERE IS AT LEAST 18 INCHES FROM EACH SIDE OF THE PIPE TO THE FORM BOARD AT THE TOP OF THE DRIVEWAY SHOULDER CULVERT PIPE IS GOOD culvert pipe is lower then other driveway on the right side 2/10 and half. i will contac stormwater engineers for revise
ROW- PRE-APRON (PRE-POUR) 08/17/2021 Disapproved - NO FEE GBERTOLA
Note: Mitered ends NO EQUALS. Top of mitered board ends must be a miminum of 18 inches from the side of the culvert. RIGHT SIDE IS 15 INCHES CHECK THAT THERE IS AT LEAST 18 INCHES FROM EACH SIDE OF THE PIPE TO THE FORM BOARD AT THE TOP OF THE DRIVEWAY SHOULDER CULVERT PIPE IS GOOD
ELECTRIC - EARLY POWER 08/05/2021 APPROVED - AS NOTED JWALKER
Note: Email FPL
GRAVITY SEWER TEST 07/26/2021 APPROVED JGIBSON
U - SEWER TIE IN 07/26/2021 APPROVED JGIBSON
PEP TANK INSTALLATION REQUEST 07/12/2021 APPROVED CSTONE
LATH/BRICK/ WATER BARRIER 06/24/2021 APPROVED MMESSER
ALL ROUGH 06/23/2021 APPROVED MMESSER
INSULATION 06/23/2021 APPROVED MMESSER
ROOF VALLEY & METAL 04/30/2021 APPROVED MMESSER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/22/2021 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 04/21/2021 APPROVED JGONZALEZ
Note: THIS IS A REINSPECTION ADDED ON 3/2/2021 2:15:15 PM
TIE BEAM / LINTEL 02/16/2021 APPROVED MMESSER
FOUND SURVEY APPROVED (OFFICE) 01/22/2021 Disapproved - NO FEE TDOAK
MONOLITHIC SLAB 12/30/2020 APPROVED MMESSER
PLUMBING 1ST ROUGH UNDERGROUND 12/21/2020 APPROVED JGIBSON
Note: THIS IS A REINSPECTION PLUMBING SUB-CONTRACTOR HAS CHANGED, NO RISER AT TIME OF INSPECTION, MUST HAVE RISER DRAWN UP BY CORRECT PLUMBING CONTRACTOR
PLUMBING 1ST ROUGH UNDERGROUND 12/18/2020 Disapproved - NO FEE JGIBSON
Note: PLUMBING SUB-CONTRACTOR HAS CHANGED, NO RISER AT TIME OF INSPECTION, MUST HAVE RISER DRAWN UP BY CORRECT PLUMBING CONTRACTOR
WATER METER INSTALLATION REQUEST 09/29/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
ZON COMPLETE 04/21/2021 04/21/2021
Note: Released By: JACQUELINE GONZALEZ - (386)986-3753 - JGONZALEZ@PALMCOASTGOV.COM
ZON HOLD 03/02/2021 03/02/2021
Note: Held By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM No revised foundation survey has been received showing the house meeting the minimum side setback.
ZON COMPLETE 01/20/2021 01/20/2021
Note: Released By: TDOAK
BLD COMPLETE 01/20/2021 01/27/2021
Note: Released By: FREODICA Revision - changed foundation, floor plan and elevation views.
ENGIN1 COMPLETE 01/20/2021 01/21/2021
Note: Released By: TBAKER
MECH COMPLETE 01/20/2021 01/21/2021
Note: Released By: CPISCITELLI
ENGIN1 COMPLETE 01/15/2021 01/19/2021
Note: Released By: TBAKER
ZON HOLD 01/15/2021 01/15/2021
Note: Held By: TDOAK House does not meet minimum 7.5' required side setback.
PLUM COMPLETE 12/21/2020 12/30/2020
Note: Released By: FREODICA No change in saniary riser diagram - only plumber.
BLD COMPLETE 08/03/2020 08/10/2020
Note: Released By: JPI
BLD HOLD 07/14/2020 07/16/2020
Note: Held By: JPI 1. Provide structural construction details for all wood frame bearing walls. 2. Provide splicing and mating details for top plate of bearing wall. 3. Provide full structural cross sections indication all fasteners and tie downs. Page 5. 4. Provide accurate and complete details of roof connections at parapet wall intersections at garage and bedroom. Truss drawings do not appear to take that area into consideration and no details have been provided. Truss plan, page 6/detail 1 does not illustrate truss behind parapet wall. Please clarify. Elevations on page 4 are also in conflict. Please clarify construction in this area. 5. Provide structural construction details for clearstory wall with attachment and window framing details. Provide a full structural construction cross section thru structure at clearstory area. R301. 6. Section 5 illustrates a 2 x 8 frame wall on top of block wall. Please provide details and cross section illustrating full structural construction details. Wall is exterior and subject to wind loads. R301. 7. Section 3 illustrates awning over kitchen window. Provide a full structural construction cross section illustrating method of construction. This overhang is subject to wind loads, full details required. 8. Product approval submittal lacking items: Zip system and roof underlayment (if applicable). 9. Garage floor should indicate slope towards door, R309.1. No response provided. 10. Provide a written response to the comments with revisions clouded on plan and page numbers of new details provided.
CUSVC COMPLETE 07/02/2020 07/08/2020
Note: Released By: HHAND
ZON COMPLETE 07/02/2020 07/06/2020
Note: Released By: ELENS
MECH COMPLETE 07/02/2020 07/06/2020
Note: Released By: CPISCITELLI
ELEC COMPLETE 07/02/2020 07/06/2020
Note: Released By: JMUNSON
BLD HOLD 07/02/2020 07/08/2020
Note: Held By: JPI Held By: JPI 1. Please provide a detailed written response to the comments with revisions clouded on plan and page numbers of new details provided. Or a comparable means of tracking the location of the revisions in the plans.
SWALE COMPLETE 06/12/2020 07/09/2020
Note: Released By: TBAKER
BLD HOLD 06/11/2020 06/15/2020
Note: Held By: JPI 1. Provide structural construction details for all wood frame bearing walls. 2. Provide splicing and mating details for top plate of bearing wall. 3. For all attachment of wood framing to masonry, please call out distance from edge of member for first fastener. IE: Fastener start @ 6” from splice and edge of wood member. 4. Provide size of attic access per R807. 5. Provide full structural cross sections indication all fasteners and tie downs. Page 5. 6. Cross section through lanai mislabeled on Page 3. Should be 5 as there is no 6. Correct. 7. Elevations on Page 4 call out two right elevations. Correct. 8. Provide accurate and complete details of roof connections at parapet wall intersections at garage and bedroom. Truss drawings do not appear to take that area into consideration and not details have been provided. 9. Provide design loads, both lateral and gravity. R301. 10. There is no door schedule, therefore no notes on rating of garage to dwelling door. 11. Provide wall sheathing nailing pattern. 12. Provide structural construction details for clearstory wall with attachment and window framing details. Provide a full structural construction cross section thru structure at clearstory area. 13. Section 5 illustrates a 2 x 8 (exterior?) frame wall on top of block wall. Please provide details and cross section illustrating full structural construction details. 14. Section 3 illustrates awning over kitchen window. Provide a full structural construction cross section illustrating method of construction. 15. Dimension attic access R807. 16. There is no carbon monoxide detector illustrated 10 feet from bedrooms 2 and 3. R315. 17. Product approval submittal lacking items: Zip system, Ply deck roof system, Single hung windows, and roof underlayment (if applicable). 18. Garage floor should indicate slope towards door, R309.1.
CUSVC HOLD 06/11/2020 06/12/2020
Note: Held By: HHAND The utility application needs to be corrected. Duplex is checked off rather than single family.
ELEC HOLD 06/11/2020 06/15/2020
Note: Held By: JMUNSON 1. Submit load calculations and riser diagram. 2. Need outlets by bathroom sinks NEC 2014 art 210.52 (D) 3. Smoke alarm outside of bedrooms needs to be a smoke/carbon combo. FBC 2017 314.3 and 315.1
ENGIN1 COMPLETE 06/11/2020 06/12/2020
Note: Released By: TBAKER
LOCATE COMPLETE 06/11/2020 06/16/2020
Note: Released By: CSTONE
MECH HOLD 06/11/2020 06/15/2020
Note: Held By: CPISCITELLI 1. Orientation of Energy calcs and heatload does not match the site plan. Revise to match the site plan. 2. Duct Drawing needs to be signed by the AC contractor
PLUM COMPLETE 06/11/2020 06/15/2020
Note: Released By: JPI
SW1 COMPLETE 06/11/2020 06/12/2020
Note: Released By: CTROHA
UTL COMPLETE 06/11/2020 06/17/2020
Note: Released By: AHALL
ZON HOLD 06/11/2020 06/12/2020
Note: Held By: AMOBLEY A total of 5 trees needed so one additional tree needed for this lot size Must have a total of 4 shrubs along each side. Left side needs one more shrub

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/17/2021
CONTRACTOR CHANGE ¤40.00 11/17/2021
SW ENG - FIELD SURVEY INSPECT ¤20.00 11/17/2021
REVISION ¤40.00 06/14/2021
CONTRACTOR CHANGE ¤40.00 06/14/2021
CONTRACTOR CHANGE ¤40.00 06/14/2021
CONTRACTOR CHANGE ¤40.00 06/14/2021
CONTRACTOR CHANGE ¤40.00 06/14/2021
CONTRACTOR CHANGE ¤40.00 06/14/2021
CONTRACTOR CHANGE ¤40.00 06/14/2021
CONTRACTOR CHANGE ¤40.00 06/14/2021
RECORDING FEE REIMBURSE DOC ¤44.00 06/14/2021
ZONING REVIEW ¤250.00 06/14/2021
IMPACT FEE TRANSPORTATION ¤1,674.00 08/31/2020
MECHANICAL FEE ¤192.00 08/31/2020
WATER -IRRIGATION INSPECTION ¤25.00 08/31/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 08/31/2020
PLAN CHECK FEE ¤88.00 08/31/2020
PLUMBING FEE ¤192.00 08/31/2020
NEW RESIDENTIAL INSPECTIONS ¤440.00 08/31/2020
CONNECTION FEES ¤1,002.88 08/31/2020
METER - DEPOSIT ¤60.00 08/31/2020
WATER- TURN ON ¤25.00 08/31/2020
ADMIN FEE ¤20.00 08/31/2020
SITE PLAN 20 ¤20.00 08/31/2020
SURCHARGE FS 533.721 ¤2.00 08/31/2020
SURCHARGE - FS 468.631 ¤2.00 08/31/2020
BUILDING DISCOUNT 100% (¤1,124.00) 08/31/2020
ELECTRIC FEE ¤192.00 08/31/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 08/31/2020
IMPACT FEE FIRE ¤223.38 08/31/2020
IMPACT FEE PARKS ¤849.24 08/31/2020
IMPACT FEE SCHOOL ¤3,600.00 08/31/2020
STORM WATER PERMIT FEES ¤80.00 08/31/2020
3% TRANS IMPACT FEE CREDIT (¤50.22) 08/31/2020
SEWER CREDIT (¤2,850.92) 08/31/2020
SEWER INSPECTION ¤25.00 08/31/2020
SEWER CAPITAL FACILITY ¤4,596.07 08/31/2020
WATER CREDIT (¤614.58) 08/31/2020
WATER CAPITAL FACILITY FEE ¤3,374.18 08/31/2020
Fees Total Due: ¤0.00 Total Paid: ¤12,724.85