I want to search for...

Permit #2020060766

Permit Details

Status: COED

Parcel Id: 48-11-31-1710-00000-1240
GARAGE: 642 sqft
OPENED PORCH (WITH ROOF) : 42 sqft
OPENED PORCH (WITH ROOF) : 302 sqft
CONDITIONED SPACE: 2224 sqft
Total Square Footage: 3210 sqft
Block: 00000
Subdivision: 2087 - ESTATES AT GRAND HAVEN PHASE II
Job Phone: (386)383-0376
Location Address: 6 TURKEY OAK LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/17/2020
NOC: RECORDED
Applicant name: ANTHONY CRAIG GUCCIONE
Owner: ROVEGNO ROBERT W & JUDITH M EDWARD JTWROS

Address

58 HEMINGWAY LN

SIMPSONVILLE, SC 29681

Lot: 1240
Contracted Stated Job Value: ¤410,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLD COAST HOME BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 354707

PALM COAST, FL 32137

CGC1507791 (Exp: 08/31/2026) 386-313-6221

Sub Contractors

BERT S MCLAUGHLIN
Status Location Address State License Number Phone
ACTIVE

131 MAGNOLIA AVE

DAYTONA BEACH, FL 32114

EC13006455 (Exp: 08/31/2026) 386-265-2687
PATRICK FRANCIS MCADAMS
Status Location Address State License Number Phone Fax
ACTIVE

1201 South Flagler Ave

Flagler Beach, FL 32136

CFC057805 (Exp: 08/31/2026) 386-283-9236 321-248-0447
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
WILLIAM D ALLEN
Status Location Address State License Number Phone Fax
INACTIVE

546 S. SHELL ROAD

DEBARY, FL 32713

LQ27843 (Exp: 08/13/2024) 386-668-9592 (386)668-8577

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/23/2021 FINAL APPROVED WMILLER
Note: THIS IS A REINSPECTION need to connect DWV and Supply at laundry room sink for test 7-23-21... notes above resolved
BLD - BUILDING FINAL 07/22/2021 Disapproved - NO FEE WMILLER
Note: need to connect DWV and Supply at laundry room sink for test
ROW - FINAL APRON (AFTER POUR) 07/16/2021 APPROVED RGROSS
ROW - STORMWATER FINAL 07/16/2021 APPROVED RGROSS
Note: Met on site with builder and grader I advised to have the sides drain to the rear due to elevtions of the utilities fire hydrant etc per (Kalen Ruth)
U -UTILITY RESIDENTIAL FINAL 07/16/2021 FINAL APPROVED JHARDING
U-CROSS CONNECTION 07/14/2021 APPROVED - AS NOTED LFITZGERALD
Note: re-claim for irrigation-no cross connection
ROW FIELD SURVEY /GRADING CERTIFICATION 07/13/2021 APPROVED RGROSS
FINAL SURVEY (OFFICE USE ONLY) 07/13/2021 APPROVED RGROSS
Note: Met on site with builder and grader I advised to have the left side drain to the rear and keep the drainage split on the right side per (Kalen Ruth)
GAS FINAL 06/18/2021 APPROVED JGIBSON
GAS ROUGH 06/14/2021 APPROVED JGIBSON
ROW - DRAINAGE 06/09/2021 APPROVED - AS NOTED KRUTH
Note: Met on site with builder and grader I advised to have the left side drain to the rear and keep the drainage split on the right side per (Kalen Ruth)
ELECTRIC - EARLY POWER 05/10/2021 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 1:45
ROW- PRE-APRON (PRE-POUR) 03/22/2021 APPROVED RGROSS
ROW- PAVER RESTRAINTS 03/22/2021 APPROVED RGROSS
ROW- PRE-APRON (PRE-POUR) 02/24/2021 APPROVED GBERTOLA
U - SEWER TIE IN 01/27/2021 APPROVED JGIBSON
GRAVITY SEWER TEST 01/27/2021 APPROVED JGIBSON
ALL ROUGH 12/18/2020 APPROVED JBODEN
INSULATION 12/18/2020 APPROVED JBODEN
LATH/BRICK/ WATER BARRIER 12/14/2020 APPROVED JBODEN
ALL ROUGH 12/04/2020 APPROVED - AS NOTED WMILLER
Note: need the following by insulation 1. fire blocking material at fire place ceiling, FIREBLOCKING MATERIALS R302.11.1 (1-8) (needs to be doubled up) 2. need to box out electric panel 3. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 4. TUB TRENCH SEALED APPENDIX F 303.3.4.2
ROOF VALLEY & METAL 12/03/2020 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/03/2020 APPROVED TSTAUFFACHER
ROOF SHEATHING 11/06/2020 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION
ROOF SHEATHING 11/03/2020 CANCELLED BY APPLICANT WMILLER
ELECTRIC-TUG 11/03/2020 APPROVED - AS NOTED JMUNSON
Note: 1. Emailed FPL at 10:28 am 2. Need to have revision on service by Early Power inspection
ROOF SHEATHING 11/02/2020 Disapproved -FEE REQUIRED WMILLER
Note: 1. ROOF SHEATHING PANELS NEED TO BE FASTENED TO ROOF FRAMING. PER R803.2.3.1 WOOD STRUCTURAL PANEL SHEATHING SHALL BE FASTENED TO ROOF FRAMING panel sheathing shall be fastened to roof framing 2. ZIP SYSTEM PANELS NEED TO BE INSTALLED SO THAT EIGHT FOOT EDGE IS ORIENTED PERPENDICULAR TO THE FRAMING MEMBERS (PER MANUFACTURER) 3. ZIP SYSTEM PANELS NEED TO BE INSTALLED SO THAT ENTIRE FOUR FOOT EDGE IS SUPPORTED FRAMING MEMBERS (PER MANUFACTURER)
ROOF SHEATHING 11/02/2020 CANCELLED BY APPLICANT WMILLER
Note: This was set accidentally for the 2nd, it was supposed to be set up for the 3rd
TIE BEAM / LINTEL 09/22/2020 APPROVED WMILLER
Note: deficiencies resolve and viewed later at apprixmately 2:48 pm via Vidio conference
ELEV CERT-FOUNDATION APPROVAL 09/16/2020 APPROVED JMYERS
FOUND SURVEY APPROVED (OFFICE) 09/16/2020 APPROVED TBAKER
MONOLITHIC SLAB 08/28/2020 APPROVED WMILLER
PLUMBING 1ST ROUGH UNDERGROUND 08/25/2020 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 08/03/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
PLFM COMPLETE 07/12/2021 07/12/2021
Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM The Final elevation certificate has been accepted.
BADMIN HOLD 06/24/2021 06/24/2021
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO TERMITE.PDF
BADMIN COMPLETE 06/24/2021 06/24/2021
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM
ELEC COMPLETE 02/01/2021 02/01/2021
Note: Released By: JMUNSON
ELEC COMPLETE 01/29/2021 02/01/2021
Note: Released By: JMUNSON
BLD CANCEL 01/19/2021 01/20/2021
Note: not needed
ELEC HOLD 01/19/2021 01/20/2021
Note: Held By: JMUNSON Plan needs to match the changes.
BLD COMPLETE 11/18/2020 11/25/2020
Note: Released By: FREODICA Revision - truss repair
BADMIN HOLD 09/15/2020 09/15/2020
Note: Held By: LMUSGROVE Document names and File names must match, No numbers or extra names Ex – site plan=site plan.
BADMIN COMPLETE 09/15/2020 09/15/2020
Note: Released By: LMUSGROVE
ZON COMPLETE 09/15/2020 09/16/2020
Note: Released By: AMOBLEY
ENGIN1 COMPLETE 09/15/2020 09/16/2020
Note: Released By: TBAKER
PLFM COMPLETE 09/15/2020 09/16/2020
Note: Released By: JMYERS The Building elevation certificate has been approved. Please provide Final prior to receiving CO.
ZON COMPLETE 06/19/2020 06/19/2020
Note: Released By: AMOBLEY
PLUM COMPLETE 06/19/2020 06/22/2020
Note: Released By: JPI
PLFM COMPLETE 06/17/2020 06/17/2020
Note: Released By: JMYERS The Construction elevation certificate has been approved. Please provide Building and Final prior to receiving CO.
BLD HOLD 06/16/2020 06/17/2020
Note: Held By: JPI 1. Provide manufacturers installation instructions on linear fireplace. Need to determine if installation in combustible structure is acceptable.
CUSVC COMPLETE 06/16/2020 06/17/2020
Note: Released By: HHAND
ELEC COMPLETE 06/16/2020 06/17/2020
Note: Released By: JMUNSON
ENGIN1 COMPLETE 06/16/2020 06/18/2020
Note: Released By: TBAKER
LOCATE COMPLETE 06/16/2020 06/16/2020
Note: Released By: CSTONE
MECH COMPLETE 06/16/2020 06/18/2020
Note: Released By: CPISCITELLI
PLUM HOLD 06/16/2020 06/17/2020
Note: Held By: JPI 1. Provide size of all piping and vents on isometric.
SW1 COMPLETE 06/16/2020 06/16/2020
Note: Released By: RGROSS
UTL COMPLETE 06/16/2020 06/17/2020
Note: Released By: LFITZGERALD
ZON HOLD 06/16/2020 06/17/2020
Note: Held By: AMOBLEY Please provide a landscape plan for review The one attached and labeled landscape was a survey not a landscape plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 07/27/2021
REVISION ¤40.00 07/27/2021
REINSPECTION FEE ¤40.00 07/27/2021
NEW RESIDENTIAL INSPECTIONS ¤820.00 07/17/2020
SITE PLAN 20 ¤20.00 07/17/2020
SURCHARGE FS 533.721 ¤2.00 07/17/2020
SURCHARGE - FS 468.631 ¤2.00 07/17/2020
STORM WATER PERMIT FEES ¤80.00 07/17/2020
3% TRANS IMPACT FEE CREDIT (¤91.77) 07/17/2020
SEWER INSPECTION ¤25.00 07/17/2020
METER - DEPOSIT ¤60.00 07/17/2020
WATER-METER ¤434.59 07/17/2020
WATER-METER ¤361.04 07/17/2020
ADMIN FEE ¤20.00 07/17/2020
CONNECTION FEES ¤25.00 07/17/2020
BUILDING DISCOUNT 100% (¤1,922.00) 07/17/2020
ELECTRIC FEE ¤306.00 07/17/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 07/17/2020
IMPACT FEE FIRE ¤223.38 07/17/2020
IMPACT FEE PARKS ¤849.24 07/17/2020
IMPACT FEE SCHOOL ¤3,600.00 07/17/2020
IMPACT FEE TRANSPORTATION ¤3,059.00 07/17/2020
MECHANICAL FEE ¤306.00 07/17/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 07/17/2020
PLAN CHECK FEE ¤164.00 07/17/2020
PLUMBING FEE ¤306.00 07/17/2020
Fees Total Due: ¤0.00 Total Paid: ¤8,737.30