I want to search for...
Permit #2020060837
Permit Details
Status: COED
| Parcel Id: 07-11-31-7030-00330-0130 |
| CONDITIONED SPACE: 1817 sqft |
| GARAGE: 433 sqft |
| OPENED PORCH (WITH ROOF) : 186 sqft |
| OPENED PORCH (WITH ROOF) : 38 sqft |
| Total Square Footage: 2474 sqft |
| Block: 00330 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: (386)437-1508 |
| Location Address: 74 RALEIGH DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/24/2020 |
| NOC: RECORDED |
| Applicant name: TAMMI SUE MARQUIS |
| Owner: YOUNG JOE |
|
Address PO BOX 9 CISSNA PARK, IL 60924 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤180,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
GULFSTREAM HOMES & CONSTRUCTION, LLC
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
PO BOX 1092 BUNNELL, FL 32110 |
CRC1326418 (Exp: 08/31/2026) | (386)437-1508 | 386-437-9769 |
Sub Contractors
JAMES CRAIG FISHER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 451 BUNNELL, FL 32110 |
CAC1819807 (Exp: 08/31/2026) | 386-222-9549 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
ARTHUR J PASCOE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 730007 ORMOND BEACH, FL 32174 |
EC13007168 (Exp: 08/31/2026) | 386-547-6439 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/11/2021 | FINAL APPROVED | MMESSER |
| U -UTILITY RESIDENTIAL FINAL | 01/11/2021 | FINAL APPROVED | LFITZGERALD |
| ROW - STORMWATER FINAL | 01/08/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: THIS IS A REINSPECTION SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE REPAIR THE SWALES ON BOTH SIDE 01/08/2021= correction made | |||
| ROW - STORMWATER FINAL | 01/07/2021 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE REPAIR THE SWALES ON BOTH SIDE | |||
| ROW - FINAL APRON (AFTER POUR) | 01/07/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: THIS IS A REINSPECTION BEFORE YOU SCHEDULE A FINAL-APRON (AFTER-POUR) ? CHECK FOR AN EXPANSION JOINT CUT DOWN THE CENTER AND LENGTH OF THE PIPE. ? CHECK FOR DIRT AND SOD. COMPACTED DIRT AND SOD MUST BE PLACED AROUND ALL EDGES OF THE POURED CONCRETE INCLUDING THE DRIVEWAY SHOULDERS TO PREVENT WASHOUT. ? CHECK FOR PAVEMENT REPAIR. REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT. ? CHECK PIPE ELEVATION TO BE SURE IT DID NOT CHANGE ELEVATION DURING THE POUR 01/07/2021=correctiom made it | |||
| U-CROSS CONNECTION | 01/04/2021 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/04/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: FOR THE STORM WATER FINAL :SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE FOR THE ROW FINAL REPAIR THE SWALE , AND REMOVE THE POTTY FROM THE SWALE AND PLACE ON THE DRIVEWAY | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/04/2021 | APPROVED | GBERTOLA |
| ELECTRIC - EARLY POWER | 11/23/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 12:00 | |||
| ROW - FINAL APRON (AFTER POUR) | 11/19/2020 | Disapproved -FEE REQUIRED | KRUTH |
| Note: BEFORE YOU SCHEDULE A FINAL-APRON (AFTER-POUR) ? CHECK FOR AN EXPANSION JOINT CUT DOWN THE CENTER AND LENGTH OF THE PIPE. ? CHECK FOR DIRT AND SOD. COMPACTED DIRT AND SOD MUST BE PLACED AROUND ALL EDGES OF THE POURED CONCRETE INCLUDING THE DRIVEWAY SHOULDERS TO PREVENT WASHOUT. ? CHECK FOR PAVEMENT REPAIR. REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT. ? CHECK PIPE ELEVATION TO BE SURE IT DID NOT CHANGE ELEVATION DURING THE POUR | |||
| ROW- PRE-APRON (PRE-POUR) | 11/04/2020 | APPROVED - AS NOTED | KRUTH |
| Note: THIS IS A REINSPECTION MATERIAL SHOULD BE COMPACTED AROUND PIPE ABOUT 1/2 WAY UP THE SIDE OF THE PIPE. IS NOT HALF WAY UP .YOU HAVE 15 ' IN EACH SID CHECK THAT THERE IS AT LEAST 18 INCHES FROM EACH SIDE OF THE PIPE TO THE FORM BOARD AT THE TOP OF THE DRIVEWAY SHOULDER.YOU HAVE 15 ' IN EACH SIDE REBARD ON SITE IS 18 INCH MINIMUM IS 24 MINIMUM. CHECK THAT AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. ON THE LEFT SIDE 24 INCH DRIVEWAY APRON.MINIMUM IS CHECK THAT THERE IS 36 INCHES OF FLARE ON THE DRIVEWAY APRON. BY THE GARAGE DOOR NEED TO CHIP THE CONCRETE IS ONLY 2 INCH HIGH,NEED 4 INCH PIPE IS GOOD 11/4/2020 corrections made | |||
| ROW- PRE-APRON (PRE-POUR) | 10/30/2020 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: MATERIAL SHOULD BE COMPACTED AROUND PIPE ABOUT 1/2 WAY UP THE SIDE OF THE PIPE. IS NOT HALF WAY UP .YOU HAVE 15 ' IN EACH SID CHECK THAT THERE IS AT LEAST 18 INCHES FROM EACH SIDE OF THE PIPE TO THE FORM BOARD AT THE TOP OF THE DRIVEWAY SHOULDER.YOU HAVE 15 ' IN EACH SIDE REBARD ON SITE IS 18 INCH MINIMUM IS 24 MINIMUM. CHECK THAT AT LEAST 24 INCHES OF #4 REBAR IS PLACED UNDER EACH END OF THE PIPE. ON THE LEFT SIDE 24 INCH DRIVEWAY APRON.MINIMUM IS CHECK THAT THERE IS 36 INCHES OF FLARE ON THE DRIVEWAY APRON. BY THE GARAGE DOOR NEED TO CHIP THE CONCRETE IS ONLY 2 INCH HIGH,NEED 4 INCH PIPE IS GOOD | |||
| U - SEWER TIE IN | 10/23/2020 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 10/23/2020 | APPROVED | JGIBSON |
| INSULATION | 09/29/2020 | APPROVED | MMESSER |
| Note: THIS IS A REINSPECTION Fire caulk or block at both sides of range hood vent. Fire caulk missed hole above electric panel. | |||
| INSULATION | 09/28/2020 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Fire caulk or block at both sides of range hood vent. Fire caulk missed hole above electric panel. | |||
| PEP TANK INSTALLATION REQUEST | 09/24/2020 | APPROVED | CSTONE |
| ALL ROUGH | 09/22/2020 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Studs are notched > 40% by drain pipes at master sink & laundry. Need to add stud near notched studs or add repair plate to existing notched stud. NOTES from 09/22/2020 Thremostat wire is below the truss line in hallway. Not code related, but should be secured. In master area hall, wire is stapled below the truss line, forcing the wire to be caught between the drywall and deadwood. Install back ordered window in shower area. Window is on backorder. Hall bath vent pipe has come loose from fan housing. | |||
| LATH/BRICK/ WATER BARRIER | 09/22/2020 | APPROVED | TSTAUFFACHER |
| ALL ROUGH | 09/21/2020 | Disapproved -FEE REQUIRED | MMESSER |
| Note: Studs are notched > 40% by drain pipes at master sink & laundry. Need to add stud near notched studs or add repair plate to existing notched stud. | |||
| ROOF VALLEY & METAL | 08/27/2020 | APPROVED | MMESSER |
| LATH/BRICK/ WATER BARRIER | 08/18/2020 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/18/2020 | APPROVED | MMESSER |
| FOUND SURVEY APPROVED (OFFICE) | 08/10/2020 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 08/05/2020 | APPROVED | MMESSER |
| MONOLITHIC SLAB | 07/21/2020 | APPROVED | MMESSER |
| WATER METER INSTALLATION REQUEST | 07/20/2020 | APPROVED | CSTONE |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/15/2020 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 08/17/2020 | 08/17/2020 |
| Note: Released By: AMOBLEY | |||
| ENGIN1 | COMPLETE | 08/07/2020 | 08/10/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 08/07/2020 | 08/07/2020 |
| Note: Released By: AMOBLEY | |||
| ZON | COMPLETE | 06/23/2020 | 06/24/2020 |
| Note: Released By: ELENS | |||
| MECH | COMPLETE | 06/23/2020 | 06/23/2020 |
| Note: Released By: CPISCITELLI | |||
| SWALE | COMPLETE | 06/18/2020 | 07/10/2020 |
| Note: Released By: TBAKER | |||
| BLD | COMPLETE | 06/17/2020 | 06/22/2020 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 06/17/2020 | 06/22/2020 |
| Note: Released By: HHAND | |||
| ELEC | COMPLETE | 06/17/2020 | 06/18/2020 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 06/17/2020 | 06/18/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 06/17/2020 | 06/17/2020 |
| Note: Released By: CSTONE | |||
| MECH | HOLD | 06/17/2020 | 06/19/2020 |
| Note: Held By: CPISCITELLI 1. Energy Calcs and EPL card need to be signed by the builder 2. Duct Drawing needs to be signed by the AC contractor | |||
| PLUM | COMPLETE | 06/17/2020 | 06/22/2020 |
| Note: Released By: JPI | |||
| SW1 | COMPLETE | 06/17/2020 | 06/17/2020 |
| Note: Released By: RGROSS | |||
| UTL | COMPLETE | 06/17/2020 | 06/19/2020 |
| Note: Released By: LFITZGERALD | |||
| ZON | HOLD | 06/17/2020 | 06/18/2020 |
| Note: Held By: ELENS Please include the "optional" arch on the front elevation, or add another form of articulation: 13.03.03. Facade design. B.Articulation. Facade articulation is required to add interest to a building. The following features shall be acceptable techniques of exterior articulation: 1. A base course or plinth course; banding, moldings, or string courses; quoins; oriels; cornices; arches; balconies; brackets; shutters; keystones; dormers; louvers as part of the exterior wall construction. 2. Quoins and banding shall wrap around the corners of the structure for at least two feet. 3. Banding placed around the windows and doors visible from the right-of-way, golf course, canals, lakes, or other similar highly visible areas. Window shutters may substitute for banding. 4. Horizontal banding continuing the length of the wall that faces a street, golf course, saltwater canal, or other similar highly visible areas. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 01/12/2021 |
| REINSPECTION FEE | ¤40.00 | 01/12/2021 |
| REINSPECTION FEE | ¤40.00 | 01/12/2021 |
| REINSPECTION FEE | ¤40.00 | 01/12/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤458.00 | 06/24/2020 |
| SITE PLAN 20 | ¤20.00 | 06/24/2020 |
| SURCHARGE FS 533.721 | ¤10.90 | 06/24/2020 |
| SURCHARGE - FS 468.631 | ¤16.35 | 06/24/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/24/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 06/24/2020 |
| SEWER INSPECTION | ¤25.00 | 06/24/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 06/24/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 06/24/2020 |
| METER - DEPOSIT | ¤60.00 | 06/24/2020 |
| WATER- TURN ON | ¤25.00 | 06/24/2020 |
| ADMIN FEE | ¤20.00 | 06/24/2020 |
| CONNECTION FEES | ¤1,002.88 | 06/24/2020 |
| ELECTRIC FEE | ¤197.40 | 06/24/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 06/24/2020 |
| IMPACT FEE FIRE | ¤223.38 | 06/24/2020 |
| IMPACT FEE PARKS | ¤849.24 | 06/24/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 06/24/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 06/24/2020 |
| MECHANICAL FEE | ¤197.40 | 06/24/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/24/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 06/24/2020 |
| PLAN CHECK FEE | ¤91.60 | 06/24/2020 |
| PLUMBING FEE | ¤197.40 | 06/24/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,821.40 |