Permit #2020061114
Permit Details
Status: FINAL
| Parcel Id: 15-11-31-5920-00070-0110 |
| CONDITIONED SPACE: 725 sqft |
| Total Square Footage: 725 sqft |
| Block: 00070 |
| Subdivision: 1214 - WATERSIDE COUNTRY CLUB - PHASE 1 |
| Job Phone: 386-585-0958 |
| Location Address: 3 HERON CT |
| Type: BA - BUILDING ADDITION |
| Issue Date: 07/20/2020 |
| NOC: RECORDED |
| Applicant name: JEFFREY G SPRAGUE |
| Owner: GOBER HERSHEL W & MARY LOUISE KEENER H&W |
|
Address 3 HERON COURT PALM COAST, FL 32137 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤87,000.00 |
| Job Description: Addition off back of house |
| Type: CN |
Contractor
JGS DESIGN ASSOCIATES, LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
8 INDIAN MOUND CT FLAGLER BEACH, FL 32136 |
CBC1260630 (Exp: 08/31/2026) | 386-585-0958 |
Sub Contractors
JOHN FREDERICK WANERKA JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
P.O. BOX 350214 BUNNELL, FL 32110 |
EC13003318 (Exp: 08/31/2022) | (386)446-9626 | (386)445-3131 |
CHARLES WEYANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 1261 FLAGLER BEACH, FL 32136 |
CAC1815058 (Exp: 08/31/2026) | (386)246-7745 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/12/2021 | FINAL APPROVED | WMILLER |
| U -UTILITY RESIDENTIAL FINAL | 03/12/2021 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL INSPECTION | 03/11/2021 | APPROVED | RGROSS |
| Note: i can not put fiel survey=NEED GRASS AROUND THE NEW STRUCTURE AND ALL THE WAYDOWN TO THE ROAD ALSO NEED TO REPLACE THE SIDEWALK TWO PIECES =CONCRETE | |||
| FINAL SURVEY (OFFICE USE ONLY) | 02/05/2021 | APPROVED | GBERTOLA |
| LATH/BRICK/ WATER BARRIER | 12/04/2020 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION 1. Not ready still working around door 2. Expansion Control Joint Needed, Maximum area (144 sq/ft) exceeded ASTM C1063 calls for 144 sq. ft 3. STUCCO STOP NEEDED AT stucco to wood intersections. 4. missing lath at top of existing wall section 12-4-2020... deficinencies noted above resolved | |||
| LATH/BRICK/ WATER BARRIER | 12/01/2020 | Disapproved - NO FEE | WMILLER |
| Note: 1. Not ready still working around door 2. Expansion Control Joint Needed, Maximum area (144 sq/ft) exceeded ASTM C1063 calls for 144 sq. ft 3. STUCCO STOP NEEDED AT stucco to wood intersections. 4. missing lath at top of existing wall section | |||
| INSULATION | 11/06/2020 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: Foam around windows | |||
| ALL ROUGH | 11/04/2020 | APPROVED | JBODEN |
| Note: THIS IS A REINSPECTION 1. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (condensate top plate) 2. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 (check all) 3. NAIL PLATE M1502.5 (liquid lines top plate) | |||
| FRAMING | 11/03/2020 | APPROVED | WMILLER |
| ALL ROUGH | 11/03/2020 | Disapproved - NO FEE | WMILLER |
| Note: 1. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (condensate top plate) 2. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 (check all) 3. NAIL PLATE M1502.5 (liquid lines top plate) | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/21/2020 | APPROVED | JBODEN |
| FOUND SURVEY APPROVED (OFFICE) | 10/19/2020 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 10/16/2020 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION Notes on Plans call for compaction. (no compaction report on site). | |||
| MONOLITHIC SLAB | 08/31/2020 | Disapproved - NO FEE | WMILLER |
| Note: Notes on Plans call for compaction. (no compaction report on site). | |||
| FOOTER | 08/10/2020 | APPROVED | JBODEN |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 10/14/2020 | 10/14/2020 |
| Note: Released By: TDOAK | |||
| ENGIN1 | COMPLETE | 10/09/2020 | 10/13/2020 |
| Note: Released By: TBAKER | |||
| ZON | HOLD | 10/09/2020 | 10/09/2020 |
| Note: Held By: TDOAK Foundation survey addition does not match the approved site plan from 6-24-20. | |||
| BLD | COMPLETE | 10/05/2020 | 10/09/2020 |
| Note: Released By: PBUCKLEY | |||
| MECH | COMPLETE | 07/13/2020 | 07/14/2020 |
| Note: Released By: CPISCITELLI | |||
| BLD | COMPLETE | 07/13/2020 | 07/17/2020 |
| Note: Released By: FREODICA | |||
| MECH | HOLD | 07/03/2020 | 07/06/2020 |
| Note: Held By: CPISCITELLI Second Page of Energy Calcs needs to be signed by the builder below the preparer | |||
| BLD | HOLD | 07/03/2020 | 07/13/2020 |
| Note: Held By: FREODICA Repeat comment for item 3: Provide FL Product approval for soffits per FS 553. 842. FReodica- 386-986-4734 | |||
| BLD | HOLD | 06/23/2020 | 06/30/2020 |
| Note: Held By: FREODICA 1. Provide truss layout complte with truss connectors with verifiable, digital signature and seal of Architec of record per FS 481.221 and FAC 61G1-16.005. 2. Provide screen eclosure design to include framing details, fasteners and material specifications. 3. Provide FL Product approval for roofing material, underlayment, and soffits per FS 553. 842. The submited FL 1956 for roofing material cannot be found on FL Product Approval Listing. FReodica-386-986-4734 | |||
| ELEC | COMPLETE | 06/23/2020 | 06/24/2020 |
| Note: Released By: JMUNSON | |||
| MECH | HOLD | 06/23/2020 | 06/24/2020 |
| Note: Held By: CPISCITELLI Energy calc needs to be signed by the builder | |||
| PLUM | CANCEL | 06/23/2020 | 06/30/2020 |
| SW1 | COMPLETE | 06/23/2020 | 06/23/2020 |
| Note: Released By: CTROHA | |||
| ZON | COMPLETE | 06/23/2020 | 06/24/2020 |
| Note: Released By: ELENS |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 07/20/2020 |
| BUILDING DISCOUNT 100% | (¤632.40) | 07/20/2020 |
| ELECTRIC FEE | ¤112.20 | 07/20/2020 |
| MECHANICAL FEE | ¤112.20 | 07/20/2020 |
| PLAN CHECK FEE | ¤40.00 | 07/20/2020 |
| REMODEL/ADDITION/ACCES INSPECT | ¤348.00 | 07/20/2020 |
| SITE PLAN 20 | ¤20.00 | 07/20/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/20/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/20/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/20/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤104.00 |