Permit #2020061114

Permit Details

Status: FINAL

Parcel Id: 15-11-31-5920-00070-0110
CONDITIONED SPACE: 725 sqft
Total Square Footage: 725 sqft
Block: 00070
Subdivision: 1214 - WATERSIDE COUNTRY CLUB - PHASE 1
Job Phone: 386-585-0958
Location Address: 3 HERON CT
Type: BA - BUILDING ADDITION
Issue Date: 07/20/2020
NOC: RECORDED
Applicant name: JEFFREY G SPRAGUE
Owner: GOBER HERSHEL W & MARY LOUISE KEENER H&W

Address

3 HERON COURT

PALM COAST, FL 32137

Lot: 0110
Contracted Stated Job Value: ¤87,000.00
Job Description: Addition off back of house
Type: CN

Contractor

JGS DESIGN ASSOCIATES, LLC
Status Location Address State License Number Phone
INACTIVE

8 INDIAN MOUND CT

FLAGLER BEACH, FL 32136

CBC1260630 (Exp: 08/31/2026) 386-585-0958

Sub Contractors

JOHN FREDERICK WANERKA JR
Status Location Address State License Number Phone Fax
CANCEL

P.O. BOX 350214

BUNNELL, FL 32110

EC13003318 (Exp: 08/31/2022) (386)446-9626 (386)445-3131
CHARLES WEYANT
Status Location Address State License Number Phone
ACTIVE

PO BOX 1261

FLAGLER BEACH, FL 32136

CAC1815058 (Exp: 08/31/2026) (386)246-7745

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/12/2021 FINAL APPROVED WMILLER
U -UTILITY RESIDENTIAL FINAL 03/12/2021 FINAL APPROVED LFITZGERALD
ROW - FINAL INSPECTION 03/11/2021 APPROVED RGROSS
Note: i can not put fiel survey=NEED GRASS AROUND THE NEW STRUCTURE AND ALL THE WAYDOWN TO THE ROAD ALSO NEED TO REPLACE THE SIDEWALK TWO PIECES =CONCRETE
FINAL SURVEY (OFFICE USE ONLY) 02/05/2021 APPROVED GBERTOLA
LATH/BRICK/ WATER BARRIER 12/04/2020 APPROVED WMILLER
Note: THIS IS A REINSPECTION 1. Not ready still working around door 2. Expansion Control Joint Needed, Maximum area (144 sq/ft) exceeded ASTM C1063 calls for 144 sq. ft 3. STUCCO STOP NEEDED AT stucco to wood intersections. 4. missing lath at top of existing wall section 12-4-2020... deficinencies noted above resolved
LATH/BRICK/ WATER BARRIER 12/01/2020 Disapproved - NO FEE WMILLER
Note: 1. Not ready still working around door 2. Expansion Control Joint Needed, Maximum area (144 sq/ft) exceeded ASTM C1063 calls for 144 sq. ft 3. STUCCO STOP NEEDED AT stucco to wood intersections. 4. missing lath at top of existing wall section
INSULATION 11/06/2020 APPROVED - AS NOTED TSTAUFFACHER
Note: Foam around windows
ALL ROUGH 11/04/2020 APPROVED JBODEN
Note: THIS IS A REINSPECTION 1. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (condensate top plate) 2. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 (check all) 3. NAIL PLATE M1502.5 (liquid lines top plate)
FRAMING 11/03/2020 APPROVED WMILLER
ALL ROUGH 11/03/2020 Disapproved - NO FEE WMILLER
Note: 1. NAIL PLATES FOR PLUMBING P2603.2.1 PROTECTION AGAINST PHYSICAL DAMAGE. (condensate top plate) 2. NAIL PLATES ON ELECTRIC FBC E3802.1 (table), AND 3802.3.2 (check all) 3. NAIL PLATE M1502.5 (liquid lines top plate)
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/21/2020 APPROVED JBODEN
FOUND SURVEY APPROVED (OFFICE) 10/19/2020 APPROVED TBAKER
MONOLITHIC SLAB 10/16/2020 APPROVED WMILLER
Note: THIS IS A REINSPECTION Notes on Plans call for compaction. (no compaction report on site).
MONOLITHIC SLAB 08/31/2020 Disapproved - NO FEE WMILLER
Note: Notes on Plans call for compaction. (no compaction report on site).
FOOTER 08/10/2020 APPROVED JBODEN

Review History

Department Status Date In Date Out
ZON COMPLETE 10/14/2020 10/14/2020
Note: Released By: TDOAK
ENGIN1 COMPLETE 10/09/2020 10/13/2020
Note: Released By: TBAKER
ZON HOLD 10/09/2020 10/09/2020
Note: Held By: TDOAK Foundation survey addition does not match the approved site plan from 6-24-20.
BLD COMPLETE 10/05/2020 10/09/2020
Note: Released By: PBUCKLEY
MECH COMPLETE 07/13/2020 07/14/2020
Note: Released By: CPISCITELLI
BLD COMPLETE 07/13/2020 07/17/2020
Note: Released By: FREODICA
MECH HOLD 07/03/2020 07/06/2020
Note: Held By: CPISCITELLI Second Page of Energy Calcs needs to be signed by the builder below the preparer
BLD HOLD 07/03/2020 07/13/2020
Note: Held By: FREODICA Repeat comment for item 3: Provide FL Product approval for soffits per FS 553. 842. FReodica- 386-986-4734
BLD HOLD 06/23/2020 06/30/2020
Note: Held By: FREODICA 1. Provide truss layout complte with truss connectors with verifiable, digital signature and seal of Architec of record per FS 481.221 and FAC 61G1-16.005. 2. Provide screen eclosure design to include framing details, fasteners and material specifications. 3. Provide FL Product approval for roofing material, underlayment, and soffits per FS 553. 842. The submited FL 1956 for roofing material cannot be found on FL Product Approval Listing. FReodica-386-986-4734
ELEC COMPLETE 06/23/2020 06/24/2020
Note: Released By: JMUNSON
MECH HOLD 06/23/2020 06/24/2020
Note: Held By: CPISCITELLI Energy calc needs to be signed by the builder
PLUM CANCEL 06/23/2020 06/30/2020
SW1 COMPLETE 06/23/2020 06/23/2020
Note: Released By: CTROHA
ZON COMPLETE 06/23/2020 06/24/2020
Note: Released By: ELENS

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 07/20/2020
BUILDING DISCOUNT 100% (¤632.40) 07/20/2020
ELECTRIC FEE ¤112.20 07/20/2020
MECHANICAL FEE ¤112.20 07/20/2020
PLAN CHECK FEE ¤40.00 07/20/2020
REMODEL/ADDITION/ACCES INSPECT ¤348.00 07/20/2020
SITE PLAN 20 ¤20.00 07/20/2020
SURCHARGE FS 533.721 ¤2.00 07/20/2020
SURCHARGE - FS 468.631 ¤2.00 07/20/2020
STORM WATER PERMIT FEES ¤80.00 07/20/2020
Fees Total Due: ¤0.00 Total Paid: ¤104.00