I want to search for...
Permit #2020070634
Permit Details
Status: COED
| Parcel Id: 48-11-31-1700-00000-0120 |
| CONDITIONED SPACE: 2769 sqft |
| GARAGE: 1280 sqft |
| OPENED PORCH (WITH ROOF) : 718 sqft |
| OPENED PORCH (WITH ROOF) : 44 sqft |
| Total Square Footage: 4811 sqft |
| Block: 00000 |
| Subdivision: 2086 - ESTATES AT GRAND HAVEN PHASE I |
| Job Phone: 386-445-2012 |
| Location Address: 115 WILLOW OAK WAY |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/23/2020 |
| NOC: RECORDED |
| Applicant name: JOHN NICHOLAS CORDASCI |
| Owner: SHAW GARY C & KAREN D H&W |
|
Address 141 LAKE RD SANDY LAKE, PA 16145 |
| Lot: 0120 |
| Contracted Stated Job Value: ¤456,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
SKYWAY BUILDERS INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 354786 PALM COAST, FL 32135 |
CBC1263769 (Exp: 08/31/2024) | 386-445-2012 |
Sub Contractors
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1963 BUNNELL, FL 32110 |
ES12001217 (Exp: 08/31/2026) | 386-437-0607 | 386-437-1847 |
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
CHARLES B NICHOLS JR
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
2680 SOUTH US HWY 17 CRESCENT CITY, FL 32112 |
00714 (Exp: 08/31/2021) | 386-698-1033 | 386-698-1077 |
THOMAS WALTER ALBANO
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P. O. BOX 352075 Palm Coast, FL 32135 |
CFC045991 (Exp: 08/31/2024) | 386-437-2795 | (386)437-2781 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/28/2021 | FINAL APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION 1. BOTTOM FED TANK TYPE WATER HEATERS VACUUM-RELIEF VALVE REQUIERD R, P2804.7 2. garbage disposal not woring 04-28-21... notes above resolved | |||
| BLD - BUILDING FINAL | 04/27/2021 | Disapproved - NO FEE | WMILLER |
| Note: 1. BOTTOM FED TANK TYPE WATER HEATERS VACUUM-RELIEF VALVE REQUIERD R, P2804.7 2. garbage disposal not woring | |||
| GAS FINAL | 04/27/2021 | APPROVED | JGIBSON |
| ROW - STORMWATER FINAL | 04/23/2021 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 04/23/2021 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 04/23/2021 | APPROVED | RGROSS |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/22/2021 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 04/22/2021 | APPROVED | RGROSS |
| GAS ROUGH | 04/07/2021 | APPROVED | JGIBSON |
| U-CROSS CONNECTION | 04/07/2021 | APPROVED | LFITZGERALD |
| ROW- PRE-APRON (PRE-POUR) | 03/08/2021 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION APPROVED FOR PAVER RESTRAINTS AND APRON. PAVER DRIVEWAY. Plenty of base on site. Builder to get good compaction before placing pavers. | |||
| ROW- PAVER RESTRAINTS | 03/03/2021 | APPROVED | RGROSS |
| ROW- PRE-APRON (PRE-POUR) | 03/03/2021 | PARTIALLY APPROVED | RGROSS |
| Note: APPROVED FOR PAVER RESTRAINTS AND APRON. PAVER DRIVEWAY | |||
| U - SEWER TIE IN | 02/09/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS INSPECTION WAS DONE 2/8/21 | |||
| GRAVITY SEWER TEST | 02/09/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS INSPECTION WAS DONE 2/8/21 | |||
| ELECTRIC - EARLY POWER | 12/29/2020 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 10:36 am | |||
| INSULATION | 11/09/2020 | APPROVED | TSTAUFFACHER |
| LATH/BRICK/ WATER BARRIER | 11/02/2020 | APPROVED | FWILLIS |
| GAS ROUGH | 10/30/2020 | APPROVED | TSTAUFFACHER |
| ALL ROUGH | 10/28/2020 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: Back lanai door is backordered. Will be installed prior to insulation inspection. Other noted items have been completed. 10/28/2020 Gas is pressurized and bonded. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/09/2020 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Truss C8 needs vertical brace above slider according to truss plans. Check again at all rough Job not ready: ROOF DECK PASSED. THIS IS NOT A COMPREHENSIVE LIST. Approved truss plans not on site Framers still working on truss details Multiple straps not secured to trusses Hollow fill cell on left side of home | |||
| ROOF VALLEY & METAL | 10/09/2020 | APPROVED | TSTAUFFACHER |
| ELECTRIC-TUG | 09/30/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 12:05 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/29/2020 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Job not ready: ROOF DECK PASSED. THIS IS NOT A COMPREHENSIVE LIST. Approved truss plans not on site Framers still working on truss details Multiple straps not secured to trusses Hollow fill cell on left side of home | |||
| TIE BEAM / LINTEL | 09/08/2020 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 08/27/2020 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/19/2020 | APPROVED | WMILLER |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/13/2020 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 07/28/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 08/26/2020 | 08/27/2020 |
| Note: Released By: AMOBLEY | |||
| ENGIN1 | COMPLETE | 08/26/2020 | 08/27/2020 |
| Note: Released By: TBAKER | |||
| BLD | COMPLETE | 07/21/2020 | 07/21/2020 |
| Note: Released By: PBUCKLEY Previous hold items removed by Chief Building Official. Inspectioin items to be resolved at time of inspection. | |||
| BLD | HOLD | 07/14/2020 | 07/20/2020 |
| Note: Held By: JPI 1. Please provide installation instructions for linear fireplace to determine UL listed appliance as well as clearance to combustibles. 2. Provide locations of hazardous glass. R08.4. | |||
| CUSVC | COMPLETE | 07/14/2020 | 07/16/2020 |
| Note: Released By: HHAND | |||
| ELEC | COMPLETE | 07/14/2020 | 07/16/2020 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 07/14/2020 | 07/15/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 07/14/2020 | 07/15/2020 |
| Note: Released By: TCHURCHILL | |||
| MECH | COMPLETE | 07/14/2020 | 07/15/2020 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 07/14/2020 | 07/20/2020 |
| Note: Released By: JPI | |||
| SW1 | COMPLETE | 07/14/2020 | 07/16/2020 |
| Note: Released By: CTROHA READ STORMWATER PACKET | |||
| UTL | COMPLETE | 07/14/2020 | 07/16/2020 |
| Note: Released By: AHALL | |||
| ZON | COMPLETE | 07/14/2020 | 07/14/2020 |
| Note: Released By: ELENS | |||
| PLFM | COMPLETE | 07/14/2020 | 07/14/2020 |
| Note: Released By: JMYERS According to the site plan submitted on 7/13/2020, the structure will be outside of the SFHA. No elevation certificates will be required. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| METER - DEPOSIT | ¤60.00 | 07/23/2020 |
| WATER-METER | ¤434.59 | 07/23/2020 |
| ADMIN FEE | ¤20.00 | 07/23/2020 |
| CONNECTION FEES | ¤25.00 | 07/23/2020 |
| BUILDING DISCOUNT 100% | (¤2,115.20) | 07/23/2020 |
| ELECTRIC FEE | ¤333.60 | 07/23/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 07/23/2020 |
| IMPACT FEE FIRE | ¤223.38 | 07/23/2020 |
| IMPACT FEE PARKS | ¤849.24 | 07/23/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/23/2020 |
| IMPACT FEE TRANSPORTATION | ¤3,059.00 | 07/23/2020 |
| MECHANICAL FEE | ¤333.60 | 07/23/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 07/23/2020 |
| PLAN CHECK FEE | ¤182.40 | 07/23/2020 |
| PLUMBING FEE | ¤333.60 | 07/23/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤912.00 | 07/23/2020 |
| SITE PLAN 20 | ¤20.00 | 07/23/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/23/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 07/23/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 07/23/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤91.77) | 07/23/2020 |
| SEWER INSPECTION | ¤25.00 | 07/23/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤8,256.26 |