Permit #2020070777
Permit Details
Status: COED
| Parcel Id: 35-11-31-4075-00000-00W0 |
| Total Square Footage: 34364 sqft |
| Block: 0 |
| Subdivision: 2296 - MARINA DEL PALMA SUBDIVISION |
| Job Phone: (386)446-6426 |
| Location Address: 46 RIO VISTA DR |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 08/17/2020 |
| NOC: RECORDED |
| Applicant name: SCOTT DALE SOWERS |
| Owner: MARINA DEL PALMA MASTER ASSC, INC |
|
Address SUITE 300 PALM COAST, FL 32164 |
| Lot: 00W0 |
| Contracted Stated Job Value: ¤2,000,000.00 |
| Job Description: DRY BOAT STORAGE BUILDING |
| Type: CN |
Contractor
S E CLINE CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 354425 PALM COAST, FL 32137 |
CGC061947 (Exp: 08/31/2028) | (386)446-6426 | (386)446-6481 |
Sub Contractors
STEPHEN P THIBAULT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P. O. Box 4398 St. Augustine, FL 32085 |
EC0002511 (Exp: 08/31/2026) | 904-829-6886 |
DANIEL J LUSINSKI
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
389 PALM COAST PARKWAY SW PALM COAST, FL 32137 |
#4 PALM COAST, FL 32137 |
CCC1330133 (Exp: 08/31/2026) | 386-338-7926 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
ISAAC WALTER JOHNSTON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
887 BRENTWOOD DRIVE Daytona Beach, FL 32117 |
CFC023634 (Exp: 08/31/2026) | (386) 252-7047 |
FRANK SOUCINEK
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
180 NW AMENITY CT LAKE CITY, FL 32056 |
CFC057747 (Exp: 08/31/2024) | (386)752-5218 | (386)752-5613 |
Inspection History
| Type | Request Date | Result | Inspector |
| U - UTILITY COMMERCIAL FINAL | 10/13/2022 | FINAL APPROVED | JHARDING |
| BUILDING FINAL | 10/12/2022 | APPROVED - AS NOTED | PBUCKLEY |
| Note: 10/6/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 3440 THIS IS A RE-INSPECTION Inspector Notes from Inspection 3460 THIS IS A RE-INSPECTION PROVIDE VERIFICATION BUILDING IS ERECTED AS PER PLAN. THIS INSPECTION ADMINISTRATIVELY APPROVED BY THE BUILDING OFFICIAL BASED ON SUBMISSION OF ENGINEERING INSPECTION REPORTS. THIS IS A STEEL BUILDING AND SO DOES NOT HAVE ANY ROOF SHEATHING PER SE AND THE ENGINEER'S INSPECTION REPORTS COVER THE REMAINING ROOF CONSTRUCTION. 7.1.22 - STILL AWAITING ENGINEERING REPORTS AS STATED IN THE LAST INSPECTION NOTES THIS FRAMING INSPECTION PERTAINS TO CONSTRUCTION OF THE INTERIOR OFFICE / BATHROOM AREA AND IS A SEPARATE FRAMING INSPECTION FROM THE BUILDING STEEL STRUCTURAL FRAME INSPECTION THAT WAS PREVIOUSLY ADMINISTRATIVELY APPROVED ON RECEIPT AND ACCEPTANCE OF ENGINEER'S INSPECTION REPORTS. GENERAL CONTRACTOR CHANGED CONSTRUCTION OF BUILDING'S INTERIOR OFFICE / BATHROOM AREA FROM STEEL STUD FRAMING TO CMU'S WITHOUT SUBMITTING PLAN REVISION AND WITHOUT CALLING FOR REQUIRED VERTICAL AND HORIZONTAL reinforcing STEEL AND GROUT POUR INSPECTIONS. I REQUESTED AN ENGINEERING REPORT SHOWING THAT REINFORCING STEELING AND GROUT IS PRESENT IN THE WALLS AND A PLAN REVISION SHOWING THE CHANGE IN CONSTRUCTION ALONG WITH A PLAN THAT BASICALLY MATCHES THE "AS-BUILT" CONDITIONS IDENTIFIED IN THE ENGINEER'S INSPECTION REPORT. THIS FRAMING INSPECTION ADMINISTRATIVELY APPROVED BUT A PLAN REVISION IS STILL REQUIRED TO DOCUMENT THE CHANGE AND DESIGN OF THE CMU WALLS. 10-6-22 - The foam plastic (spray on) insulation at the underside of roof deck structure needs to be seperated from the space below by approved material. Fire rated "lay-in" ceiling tiles may be utilized, or an approved coating acceptable for use over foam plastic insulation. 2603.4 Thermal barrier. Except as provided for in FBC - Sections 2603.4.1 and 2603.9, foam plastic shall be separated from the interior of a building by an approved thermal barrier of 1/2-inch (12.7 mm) gypsum wallboard, heavy timber in accordance with Section 602.4 or a material that is tested in accordance with and meets the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of NFPA 275. 10/12/22 BUILDING FINAL INSPECTION APPROVED. CONTRACTOR SUBMITTED DOCUMENTATION INDICATING SPRAY FOAM INSULATION WAS COVERED WITH AN APPROVED INTUMESCENT COATING IN COMPLAINCE WITH THE REFERENCED CODE SECTIONS. DOCUMENTATION INCLUDING ICC ES REPORT UPLOADED TO PERMIT RECORD. PATRICK BUCKLEY | |||
| BUILDING FINAL | 10/06/2022 | Disapproved - NO FEE | DCUSHING |
| Note: Inspector Notes from Inspection 3440 THIS IS A RE-INSPECTION Inspector Notes from Inspection 3460 THIS IS A RE-INSPECTION PROVIDE VERIFICATION BUILDING IS ERECTED AS PER PLAN. THIS INSPECTION ADMINISTRATIVELY APPROVED BY THE BUILDING OFFICIAL BASED ON SUBMISSION OF ENGINEERING INSPECTION REPORTS. THIS IS A STEEL BUILDING AND SO DOES NOT HAVE ANY ROOF SHEATHING PER SE AND THE ENGINEER'S INSPECTION REPORTS COVER THE REMAINING ROOF CONSTRUCTION. 7.1.22 - STILL AWAITING ENGINEERING REPORTS AS STATED IN THE LAST INSPECTION NOTES THIS FRAMING INSPECTION PERTAINS TO CONSTRUCTION OF THE INTERIOR OFFICE / BATHROOM AREA AND IS A SEPARATE FRAMING INSPECTION FROM THE BUILDING STEEL STRUCTURAL FRAME INSPECTION THAT WAS PREVIOUSLY ADMINISTRATIVELY APPROVED ON RECEIPT AND ACCEPTANCE OF ENGINEER'S INSPECTION REPORTS. GENERAL CONTRACTOR CHANGED CONSTRUCTION OF BUILDING'S INTERIOR OFFICE / BATHROOM AREA FROM STEEL STUD FRAMING TO CMU'S WITHOUT SUBMITTING PLAN REVISION AND WITHOUT CALLING FOR REQUIRED VERTICAL AND HORIZONTAL reinforcing STEEL AND GROUT POUR INSPECTIONS. I REQUESTED AN ENGINEERING REPORT SHOWING THAT REINFORCING STEELING AND GROUT IS PRESENT IN THE WALLS AND A PLAN REVISION SHOWING THE CHANGE IN CONSTRUCTION ALONG WITH A PLAN THAT BASICALLY MATCHES THE "AS-BUILT" CONDITIONS IDENTIFIED IN THE ENGINEER'S INSPECTION REPORT. THIS FRAMING INSPECTION ADMINISTRATIVELY APPROVED BUT A PLAN REVISION IS STILL REQUIRED TO DOCUMENT THE CHANGE AND DESIGN OF THE CMU WALLS. 10-6-22 - The foam plastic (spray on) insulation at the underside of roof deck structure needs to be seperated from the space below by approved material. Fire rated "lay-in" ceiling tiles may be utilized, or an approved coating acceptable for use over foam plastic insulation. 2603.4 Thermal barrier. Except as provided for in FBC - Sections 2603.4.1 and 2603.9, foam plastic shall be separated from the interior of a building by an approved thermal barrier of 1/2-inch (12.7 mm) gypsum wallboard, heavy timber in accordance with Section 602.4 or a material that is tested in accordance with and meets the acceptance criteria of both the Temperature Transmission Fire Test and the Integrity Fire Test of NFPA 275. | |||
| HVAC FINAL | 10/06/2022 | FINAL APPROVED | CPISCITELLI |
| Note: THIS IS A REINSPECTION not ready. Need to revise plans | |||
| FRAMING | 09/01/2022 | APPROVED - AS NOTED | PBUCKLEY |
| Note: THIS IS A RE-INSPECTION Inspector Notes from Inspection 3460 THIS IS A RE-INSPECTION PROVIDE VERIFICATION BUILDING IS ERECTED AS PER PLAN. THIS INSPECTION ADMINISTRATIVELY APPROVED BY THE BUILDING OFFICIAL BASED ON SUBMISSION OF ENGINEERING INSPECTION REPORTS. THIS IS A STEEL BUILDING AND SO DOES NOT HAVE ANY ROOF SHEATHING PER SE AND THE ENGINEER'S INSPECTION REPORTS COVER THE REMAINING ROOF CONSTRUCTION. 7.1.22 - STILL AWAITING ENGINEERING REPORTS AS STATED IN THE LAST INSPECTION NOTES THIS FRAMING INSPECTION PERTAINS TO CONSTRUCTION OF THE INTERIOR OFFICE / BATHROOM AREA AND IS A SEPARATE FRAMING INSPECTION FROM THE BUILDING STEEL STRUCTURAL FRAME INSPECTION THAT WAS PREVIOUSLY ADMINISTRATIVELY APPROVED ON RECEIPT AND ACCEPTANCE OF ENGINEER'S INSPECTION REPORTS. GENERAL CONTRACTOR CHANGED CONSTRUCTION OF BUILDING'S INTERIOR OFFICE / BATHROOM AREA FROM STEEL STUD FRAMING TO CMU'S WITHOUT SUBMITTING PLAN REVISION AND WITHOUT CALLING FOR REQUIRED VERTICAL AND HORIZONTAL reinforcing STEEL AND GROUT POUR INSPECTIONS. I REQUESTED AN ENGINEERING REPORT SHOWING THAT REINFORCING STEELING AND GROUT IS PRESENT IN THE WALLS AND A PLAN REVISION SHOWING THE CHANGE IN CONSTRUCTION ALONG WITH A PLAN THAT BASICALLY MATCHES THE "AS-BUILT" CONDITIONS IDENTIFIED IN THE ENGINEER'S INSPECTION REPORT. THIS FRAMING INSPECTION ADMINISTRATIVELY APPROVED BUT A PLAN REVISION IS STILL REQUIRED TO DOCUMENT THE CHANGE AND DESIGN OF THE CMU WALLS. | |||
| FIRE FINAL | 08/19/2022 | APPROVED | RMARTIN |
| Note: ensure knox box and extinguishers are in place | |||
| FRAMING | 07/01/2022 | Disapproved - NO FEE | DCUSHING |
| Note: Inspector Notes from Inspection 3460 THIS IS A REINSPECTION PROVIDE VERIFICATION BUILDING IS ERECTED AS PER PLAN. THIS INSPECTION ADMINISTRATIVELY APPROVED BY THE BUILDING OFFICIAL BASED ON SUBMISSION OF ENGINEERING INSPECTION REPORTS. THIS IS A STELL BUILDING AND SO DOES NOT HAVE ANY ROOF SHEATHING PER SE AND THE ENGINEER'S INSPECTION REPORTS COVER THE REMAINING ROOF CONSTRUCTION. 7.1.22 - STILL AWAITING ENGINEERING REPORTS AS STATED IN THE LAST INSPECTION NOTES | |||
| ELECTRIC FINAL | 07/01/2022 | APPROVED | JMUNSON |
| ROOF SHEATHING / BRACE / TIE DOWN | 06/17/2022 | APPROVED - AS NOTED | PBUCKLEY |
| Note: THIS IS A REINSPECTION PROVIDE VERIFICATION BUILDING IS ERECTED AS PER PLAN. THIS INSPECTION ADMINISTRATIVELY APPROVED BY THE BUILDING OFFICIAL BASED ON SUBMISSION OF ENGINEERING INSPECTION REPORTS. THIS IS A STEEL BUILDING AND SO DOES NOT HAVE ANY ROOF SHEATHING PER SE AND THE ENGINEER'S INSPECTION REPORTS COVER THE REMAINING ROOF CONSTRUCTION. | |||
| PLUMBING FINAL | 06/02/2022 | APPROVED | MGIBSON |
| BLD - GREASE INTERCEPTOR PLUMBING & VENTING | 05/26/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER | 05/26/2022 | APPROVED | MGIBSON |
| Note: THIS IS A REINSPECTION Not ready for inspection | |||
| PLUMBING 2ND ROUGH | 05/24/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS IS A REINSPECTION Change in construction manager. See Mike Holland upon arrival. Looks like this inspection may have been missed. Provide direction to construction manager as to how to proceed to obtain 2nd roug-in approval. See Patrick with any questions. SPOKE WITH MIKE UNDERWOOD HE WILL BE PRESENT AT TIME OF SCHEDULED INSPECTION, AND HE WAS ADVISED AS TO WHAT NEEDS TO BE DONE SECOND ROUGH IS APPROVED, BEFORE PLUMBING FINAL CAN BE SCHEDULED NEED WATER HEATER TO HAVE VACCUME BREAKER INSTALLED FOR BOTTOM FEED WATER HEATER, NEED PAN DRAIN LINE TO BE CPVC NOT PVC, NEED 3'' TO TERMINATE TO OPEN AIR STUDDER VENT NOT ALLOWED, AND NEED TO CHANGE PLUMBING CONTRACTOR TO ''MASTER CRAFT | |||
| FOOTER | 04/27/2022 | APPROVED - AS NOTED | PBUCKLEY |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION grade beams (highlighted on plans in field and approved plans in construction office) 4/12/22 - PROVIDE PROOF OF REBAR IN FOOTER AND PROOF OF PSI IN CONCRETE. FOOTING INSPECTIONS ADMINISTRATIVELY APPROVED BY CBO BASED ON 18 DIFFERENT ENGINEERING REPORTS SUBMITTED DOCUMENTING INSPECTIONS OF ALL FOOTINGS BY FLORIDA LICENSED P.E. ALL INSPECTION REPORTS ATTACHED TO PERMIT RECORD. | |||
| FRAMING | 04/12/2022 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: THIS IS A REINSPECTION Construction management has changed. See Mike Underwood when on site. Building is a steel building, ask for engineer's inspection report to approve framing inspection. Advise on what is needed for fre final. See Patrick with any questions. 9-8-21... No Inspection, Need contractor on site for inspection 4/12/22 - BUILDING IS COMPLETE, INSPECTION MISSED. WILL NEED LETTERS FROM THE ENGINEER AND MANUFACTURER SHOWING ERECTED AS PER DESIGNED. | |||
| ABOVE CEILING | 04/12/2022 | APPROVED - AS NOTED | RMARTIN |
| Note: NO ABOVE CEILING NEEDED | |||
| INSULATION | 04/12/2022 | APPROVED - AS NOTED | FWILLIS |
| Note: DID NOT SEE WHERE INSULATION WAS NEEDED. | |||
| STOREFRONT | 04/12/2022 | Disapproved - NO FEE | FWILLIS |
| Note: WILL CHECK ON NEXT INSPECTION. MIGHT NOT BE NEEDED. | |||
| FOOTER | 04/12/2022 | Disapproved - NO FEE | FWILLIS |
| Note: THIS IS A REINSPECTION grade beams (highlighted on plans in field and approved plans in construction office) 4/12/22 - PROVIDE PROOF OF REBAR IN FOOTER AND PROOF OF PSI IN CONCRETE. | |||
| GRAVITY SEWER | 04/12/2022 | Disapproved - NO FEE | PBUCKLEY |
| Note: Not ready for inspection | |||
| HVAC ROUGH | 04/12/2022 | APPROVED - AS NOTED | CPISCITELLI |
| Note: THIS IS A REINSPECTION submit revision showing onsite conditions will look at all on final. | |||
| HVAC FINAL | 04/12/2022 | Disapproved - NO FEE | CPISCITELLI |
| Note: not ready. Need to revise plans | |||
| ROOF SHEATHING / BRACE / TIE DOWN | 04/12/2022 | Disapproved - NO FEE | FWILLIS |
| Note: PROVIDE VERIFICATION BUILDING IS ERECTED AS PER PLAN. | |||
| EXTERIOR ARCHITECTURAL FEATURES | 04/12/2022 | APPROVED - AS NOTED | JHARDING |
| Note: Must submit revised plans to Damaris Ramiros at CITY HALL. | |||
| HVAC ROUGH | 09/08/2021 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: New Construction managment. See Mike Underwood on site. Looks like they may have missed required HVAC rough inspection. According to Mike, no mechanical in stack house but a mini-split and possibly exhaust fans in small office and bathroom areas. Advise Mr. Underwood what he needs to do in order to proceed towards HVAC rough inspection approval. See Patrick with any questions. | |||
| PLUMBING 2ND ROUGH | 09/08/2021 | Disapproved - NO FEE | JGIBSON |
| Note: Change in construction manager. See Mike Holland upon arrival. Looks like this inspection may have been missed. Provide direction to construction manager as to how to proceed to obtain 2nd roug-in approval. See Patrick with any questions. SPOKE WITH MIKE UNDERWOOD HE WILL BE PRESENT AT TIME OF SCHEDULED INSPECTION, AND HE WAS ADVISED AS TO WHAT NEEDS TO BE DONE | |||
| FRAMING | 09/08/2021 | Disapproved - NO FEE | LMILLER |
| Note: Construction management has changed. See Mike Underwood when on site. Building is a steel building, ask for engineer's inspection report to approve framing inspection. Advise on what is needed for fre final. See Patrick with any questions. 9-8-21... No Inspection, Need contractor on site for inspection | |||
| ELECTRIC 1ST ROUGH | 08/13/2021 | APPROVED | RMARTIN |
| ELECTRIC 2ND ROUGH | 08/13/2021 | APPROVED | RMARTIN |
| ELECTRIC - EARLY POWER | 06/25/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 2:50 | |||
| MONOLITHIC SLAB | 05/20/2021 | PARTIALLY APPROVED | BGREVE |
| Note: only boat ramp area | |||
| LINTEL | 04/15/2021 | APPROVED | JBODEN |
| FOUNDATION SURVEY - OFFICE USE ONLY | 04/13/2021 | APPROVED | DLEAP |
| BLD - SEWER TIE IN | 02/10/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: THIS WAS SUPPOSED TO BE U-SEWER TIE IN | |||
| U - SEWER TIE IN | 02/10/2021 | APPROVED | JGIBSON |
| MONOLITHIC SLAB | 09/09/2020 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION ADDED ON 9/3/2020 2:59:45 PM THIS IS A REINSPECTION THIS IS A REINSPECTION (approved areas highlighted on plans in field and approved plans in construction office) Partial (section highlighted on plans in construction office) 9-3-2020.... All eccept Grade beam and track at door 9-9-2020... APPROVED | |||
| MONOLITHIC SLAB | 09/03/2020 | PARTIALLY APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION (approved areas highlighted on plans in field and approved plans in construction office) Partial (section highlighted on plans in construction office) 9-3-2020.... All eccept Grade beam and track at door | |||
| ELECTRIC UNDERGROUND | 09/03/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: LOOKED AT UFER RE-BAR, AND SERVICE CONDUITS UNDER SLAB | |||
| PLUMBING 1ST ROUGH | 09/02/2020 | APPROVED | JGIBSON |
| MONOLITHIC SLAB | 09/02/2020 | PARTIALLY APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION (approved areas highlighted on plans in field and approved plans in construction office) Partial (section highlighted on plans in construction office) | |||
| FIRE PUMP 1ST RGH/PLACEMENT | 09/02/2020 | APPROVED - AS NOTED | WMILLER |
| Note: This was called in by the GC because there was no Fire Underground permit approval yet. This is only a visual (the Fire Underground is in apply status and no documents are on site). Must match Documents for Fire Underground for approval under the Fire Undrground Permit. | |||
| MONOLITHIC SLAB | 08/27/2020 | PARTIALLY APPROVED | WMILLER |
| Note: (approved areas highlighted on plans in field and approved plans in construction office) | |||
| FOOTER | 08/27/2020 | PARTIALLY APPROVED | WMILLER |
| Note: grade beams (highlighted on plans in field and approved plans in construction office) |
Review History
| Department | Status | Date In | Date Out |
| ARCHR | COMPLETE | 09/22/2022 | 09/22/2022 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/21/2022 | 09/22/2022 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/12/2022 | 08/12/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide fresh air duct on duct layout | |||
| MECH | HOLD | 07/07/2022 | 07/07/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Digital signature and seal needs to be verifiable. Unable to Verify per F.S. 471.025 | |||
| PLENG | COMPLETE | 04/13/2021 | 04/13/2021 |
| Note: Released By: DENNIS LEAP - - DLEAP@PALMCOASTGOV.COM | |||
| PLENG | HOLD | 04/09/2021 | 04/09/2021 |
| Note: Held By: DENNIS LEAP - - DLEAP@PALMCOASTGOV.COM Foundation Survey 1. Provide building tie to east property line 2. Provide building tie to south property line. | |||
| ENGIN1 | CANCEL | 04/07/2021 | 04/09/2021 |
| DSD | CANCEL | 04/07/2021 | 04/09/2021 |
| MECH | COMPLETE | 08/14/2020 | 08/14/2020 |
| Note: Released By: CPISCITELLI | |||
| ELEC | COMPLETE | 08/14/2020 | 08/17/2020 |
| Note: Released By: JMUNSON | |||
| ARCHR | COMPLETE | 08/14/2020 | 08/14/2020 |
| Note: Released By: BDAWSON | |||
| BADMIN | COMPLETE | 07/23/2020 | 07/23/2020 |
| Note: Released By: LMUSGROVE | |||
| ARCHR | HOLD | 07/23/2020 | 08/03/2020 |
| Note: Held By: BDAWSON - Architectural elevations do not match what was approved on the site development permit. Elevations should also call out all color selections. | |||
| BLD | COMPLETE | 07/23/2020 | 08/07/2020 |
| Note: Released By: JBODEN | |||
| DSD | COMPLETE | 07/23/2020 | 07/24/2020 |
| Note: Released By: JGONZALEZ | |||
| ELEC | HOLD | 07/23/2020 | 07/28/2020 |
| Note: Held By: JMUNSON 1. Plans need to be signed and sealed. FAC 61G15- 23.001 2. Clarify all of the revision bubbles. | |||
| FI1 | COMPLETE | 07/23/2020 | 08/05/2020 |
| Note: Released By: JBODEN | |||
| MECH | HOLD | 07/23/2020 | 07/28/2020 |
| Note: Held By: CPISCITELLI 1. Mechanical Plans need engineer's seal. FAC 61G15-23.001 2. Clarify revision bubbles on plans | |||
| PLUM | COMPLETE | 07/23/2020 | 08/06/2020 |
| Note: Released By: JBODEN | |||
| UD1 | COMPLETE | 07/23/2020 | 07/24/2020 |
| Note: Released By: CJOHNSON | |||
| BADMIN | HOLD | 07/16/2020 | 07/16/2020 |
| Note: Held By: BBEMBRY Plans must be submitted as individual pages . The file names must match the naming convention outlined on the 'document submittal guidelines' on the permit portal page. One set of plans is required, I am unsure if the submittal consists of two sets of plans. If there is more than one building - each building will require a separate permit. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION - COMMERCIAL | ¤60.00 | 10/12/2022 |
| EXTENSION | ¤40.00 | 02/01/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 10/13/2020 |
| BUILDING DISCOUNT 100% | (¤17,140.00) | 08/17/2020 |
| ELECTRIC FEE | ¤1,260.00 | 08/17/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤291.96) | 08/17/2020 |
| IMPACT FEE FIRE | ¤9,731.88 | 08/17/2020 |
| MECHANICAL FEE | ¤1,260.00 | 08/17/2020 |
| PERMIT FEE | ¤11,000.00 | 08/17/2020 |
| PLAN CHECK FEE | ¤2,300.00 | 08/17/2020 |
| PLUMBING FEE | ¤1,260.00 | 08/17/2020 |
| SITE PLAN 20 | ¤20.00 | 08/17/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/17/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/17/2020 |
| ADMIN COMMERCIAL | ¤60.00 | 08/17/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤9,603.92 |