I want to search for...
Permit #2020070852
Permit Details
Status: COED
| Parcel Id: 07-11-31-7028-00340-0110 |
| CONDITIONED SPACE: 1236 sqft |
| GARAGE: 472 sqft |
| OPENED PORCH (WITH ROOF) : 65 sqft |
| Total Square Footage: 1773 sqft |
| Block: 00340 |
| Subdivision: 2199 - SECTION 28-WYNNFIELD |
| Job Phone: 386-931-2131 |
| Location Address: 24 POST LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/19/2020 |
| NOC: RECORDED |
| Applicant name: FLAGLER HABITAT |
| Owner: FLAGLER HABITAT FOR HUMANITY INC |
|
Address PO BOX 187 BUNNELL, FL 32110 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤80,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FLAGLER HABITAT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2 WEST MOODY BLVD BUNNELL, FL 32110 |
HABITAT | 386-931-2131 |
Sub Contractors
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1963 BUNNELL, FL 32110 |
ES12001217 (Exp: 08/31/2026) | 386-437-0607 | 386-437-1847 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
MICHAEL A PENAGOS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3321 GLENSHANE WAY ORMOND BEACH, FL 32174 |
CCC1330460 (Exp: 08/31/2026) | 386-569-9133 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/25/2021 | FINAL APPROVED | MMESSER |
| U-CROSS CONNECTION | 03/25/2021 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation | |||
| U -UTILITY RESIDENTIAL FINAL | 03/25/2021 | FINAL APPROVED | LFITZGERALD |
| ROW - STORMWATER FINAL | 03/24/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: THIS IS INSPECTION WAS APPROVED ALL READY | |||
| ROW - FINAL APRON (AFTER POUR) | 03/24/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION EMPTY LOT AT THE EDGE NEED TO PLACE SOD OR SEEDED OR COVER W/STAW AND/OR PINE NEEDLE CHECK FOR PAVEMENT REPAIR. REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT 03/19/2021= IT IS A TRIP HAZARD NEED A HOT PATCH 03/23/2021=THE ROAD NEED A HOT PATCH 03/24/2021=CORRECTION WERE MADE | |||
| ROW - FINAL APRON (AFTER POUR) | 03/23/2021 | Disapproved - NO FEE | GBERTOLA |
| Note: THIS IS A REINSPECTION EMPTY LOT AT THE EDGE NEED TO PLACE SOD OR SEEDED OR COVER W/STAW AND/OR PINE NEEDLE CHECK FOR PAVEMENT REPAIR. REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT 03/19/2021= IT IS A TRIP HAZARD NEED A HOT PATCH 03/23/2021=THE ROAD NEED A HOT PATCH | |||
| ROW - STORMWATER FINAL | 03/23/2021 | Disapproved - NO FEE | GBERTOLA |
| Note: THE ROAD NEED A HOT PATCH | |||
| ROW - STORMWATER FINAL | 03/23/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: THIS IS A DUPLICATE THIS INSPECTION WAS APROVE | |||
| ROW - FINAL APRON (AFTER POUR) | 03/19/2021 | Disapproved - NO FEE | GBERTOLA |
| Note: EMPTY LOT AT THE EDGE NEED TO PLACE SOD OR SEEDED OR COVER W/STAW AND/OR PINE NEEDLE CHECK FOR PAVEMENT REPAIR. REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT 03/19/2021= IT IS A TRIP HAZARD THE LIP LEFTED AT THE EDGE OF APRON BY THE ROAD NEED A HOT PATCH | |||
| ROW - STORMWATER FINAL | 03/19/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: EMPTY LOT AT THE EDGE NEED TO PLACE SOD OR SEEDED OR COVER W/STAW AND/OR PINE NEEDLE CHECK FOR PAVEMENT REPAIR. REPAIR THE ROAD ALONG THE FULL WIDTH OF THE DRIVEWAY AND ANY OTHER ROAD DAMAGE WITH HOT PATCH ASPHALT 03/19/2021= IT IS A TRIP HAZARD THE LIP LEFTED AT THE EDGE OF APRON BY THE ROAD NEED A HOT PATCH | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/17/2021 | APPROVED | GBERTOLA |
| FINAL SURVEY (OFFICE USE ONLY) | 03/17/2021 | APPROVED | GBERTOLA |
| ROW- PRE-APRON (PRE-POUR) | 01/28/2021 | APPROVED - AS NOTED | GBERTOLA |
| Note: READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. I WOULD ADD A FORM TO THE BOTTOM OF THE END OF THE MITERS SO CONCRETE DOES NOT GET POURED INTO THE SWALE. | |||
| GRAVITY SEWER TEST | 01/14/2021 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 01/14/2021 | APPROVED | JGIBSON |
| ELECTRIC - EARLY POWER | 01/12/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 10:00 | |||
| PEP TANK INSTALLATION REQUEST | 12/16/2020 | APPROVED | CSTONE |
| INSULATION | 12/15/2020 | APPROVED | MMESSER |
| ALL ROUGH | 12/11/2020 | APPROVED | MMESSER |
| ROOF VALLEY & METAL | 12/07/2020 | APPROVED | MMESSER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/19/2020 | APPROVED | MMESSER |
| WINDOW NAILING | 11/18/2020 | APPROVED | MMESSER |
| WALL SHEATHING | 10/27/2020 | APPROVED | MMESSER |
| FOUND SURVEY APPROVED (OFFICE) | 10/22/2020 | APPROVED | TBAKER |
| ELECTRIC TEMP POLE | 10/09/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 8:45 | |||
| MONOLITHIC SLAB | 09/28/2020 | APPROVED | MMESSER |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/23/2020 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 09/09/2020 | APPROVED | TCHURCHILL |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 10/21/2020 | 10/22/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 10/21/2020 | 10/21/2020 |
| Note: Released By: TDOAK | |||
| BLD | COMPLETE | 08/11/2020 | 08/17/2020 |
| Note: Released By: PBUCKLEY | |||
| ELEC | COMPLETE | 08/11/2020 | 08/12/2020 |
| Note: Released By: JMUNSON | |||
| ZON | COMPLETE | 08/11/2020 | 08/11/2020 |
| Note: Released By: ELENS | |||
| MECH | COMPLETE | 08/11/2020 | 08/12/2020 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 08/11/2020 | 08/11/2020 |
| Note: Released By: JPI | |||
| BLD | HOLD | 07/30/2020 | 07/30/2020 |
| Note: Held By: PBUCKLEY COMMENTS FROM JPI REVIEW REVISED BELOW. PLEASE RESPOND TO THIS REVISED LIST OF COMMENTS. 1. Product approval spec sheet missing the following items: roof shingles, underlayment and roof vent. 2. Wall sections illustrate exterior sheathing in contact with soil. Minimum distance to ground is 6 per R317.1. Illustrate dimension on plans. 3. Door schedule does not call out door to hall bath. Please provide. Must meet R320 for minimum size. 4. Attic ventilation calculation table is incomplete/blank. | |||
| SWALE | COMPLETE | 07/20/2020 | 07/29/2020 |
| Note: Released By: TBAKER | |||
| BLD | HOLD | 07/17/2020 | 07/22/2020 |
| Note: Held By: JPI 1. Smoke and carbon monoxide detectors to maintain clearances from supply/return ductwork, bathrooms, kitchen cooking appliances, etc… per R314/315. Combo detector located outside bedroom 2 and 3 must maintain a minimum 3 foot distance from bathroom. 2. Product approval spec sheet missing the following items: roof shingles, underlayment and roof vent. 3. Wood header detail on page A3 calls out for SP4 at king stud, clarify if same strap will be used on common studs in the load bearing wall. 4. Wall sections illustrate exterior sheathing in contact with soil. Minimum distance to ground is 6” per R317.1. Illustrate dimension on plans. 5. Door schedule does not call out door to hall bath. Please provide. Must meet R320 for minimum size. 6. Provide locations of hazardous glass. R08.4. 7. Attic ventilation calculation table is incomplete/blank. 8. Provide a written response to the comments with revisions clouded on plan and page numbers of new details provided. | |||
| CUSVC | COMPLETE | 07/17/2020 | 07/22/2020 |
| Note: Released By: HHAND | |||
| ELEC | HOLD | 07/17/2020 | 07/20/2020 |
| Note: Held By: JMUNSON Submit Electrical load calculations | |||
| ENGIN1 | COMPLETE | 07/17/2020 | 07/20/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 07/17/2020 | 07/20/2020 |
| Note: Released By: CSTONE | |||
| MECH | HOLD | 07/17/2020 | 07/20/2020 |
| Note: Held By: CPISCITELLI Orientation of Energy calcs does not match the site plan. Revise to match the site plan | |||
| PLUM | HOLD | 07/17/2020 | 07/22/2020 |
| Note: Held By: JPI 1. Plumbing page P1 does not illustrate DWV properly. There is a connection shown to refrigerator rather than kitchen sink. 2. Isometric plumbing plan does not indicate a vent for kitchen sink. 3. Please coordinate both plumbing plans to match. | |||
| SW1 | COMPLETE | 07/17/2020 | 07/20/2020 |
| Note: Released By: CTROHA | |||
| UTL | COMPLETE | 07/17/2020 | 07/21/2020 |
| Note: Released By: LFITZGERALD | |||
| ZON | HOLD | 07/17/2020 | 07/20/2020 |
| Note: Held By: ELENS Site plan is missing rear setback from the closest point of the residence to the rear property line. (It has the arrow, but not the distance.) The landscape plan requires a shrub to be placed on the site of the A/C pad to properly screen it. You can add another 7 gallon shrub on the side, or move the one from the rear of the A/C pad to the side of the A/C pad. (I just added one for you on the plan I reviewed last week, but this needs to be corrected on this and future submissions.) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| METER - DEPOSIT | ¤60.00 | 08/19/2020 |
| WATER- TURN ON | ¤25.00 | 08/19/2020 |
| ADMIN FEE | ¤20.00 | 08/19/2020 |
| CONNECTION FEES | ¤1,002.88 | 08/19/2020 |
| BUILDING DISCOUNT 100% | (¤867.80) | 08/19/2020 |
| ELECTRIC FEE | ¤155.40 | 08/19/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 08/19/2020 |
| IMPACT FEE FIRE | ¤223.38 | 08/19/2020 |
| IMPACT FEE PARKS | ¤849.24 | 08/19/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 08/19/2020 |
| MECHANICAL FEE | ¤155.40 | 08/19/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 08/19/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 08/19/2020 |
| PLAN CHECK FEE | ¤63.60 | 08/19/2020 |
| PLUMBING FEE | ¤155.40 | 08/19/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤318.00 | 08/19/2020 |
| SITE PLAN 20 | ¤20.00 | 08/19/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/19/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/19/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/19/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 08/19/2020 |
| SEWER CREDIT | (¤650.00) | 08/19/2020 |
| SEWER INSPECTION | ¤25.00 | 08/19/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 08/19/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 08/19/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤11,226.35 |