I want to search for...
Permit #2020071073
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7017-00050-0110 |
| CONDITIONED SPACE: 497 sqft |
| Total Square Footage: 497 sqft |
| Block: 00050 |
| Subdivision: 2129 - SECTION 17-BELLE TERRE |
| Job Phone: (386)775-0171 |
| Location Address: 22 BOSTON LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 08/24/2020 |
| NOC: RECORDED |
| Applicant name: FRANK MICHAEL MILLER |
| Owner: ELLIS STEPHEN A & LARYSA ELLIS |
|
Address 22 BOSTON LANE PALM COAST, FL 32137 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤49,000.00 |
| Job Description: Addition in rear with pool bath |
| Type: CN |
Contractor
F-M BUILDER AND CONSTRUCTION SERVICES LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
613 PINEVIEW DRIVE ORANGE CITY, FL 32763 |
CBC022168 (Exp: 08/31/2022) | (386)775-0171 |
Sub Contractors
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1351 HAZELNUT ST BUNNELL, FL 32110 |
CFC1427527 (Exp: 08/31/2026) | 386-445-2532 | 386-445-5575 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/23/2021 | FINAL APPROVED | FWILLIS |
| U -UTILITY RESIDENTIAL FINAL | 06/23/2021 | FINAL APPROVED | DHANEY |
| FINAL SURVEY (OFFICE USE ONLY) | 06/22/2021 | APPROVED | GBERTOLA |
| TUB SET | 06/21/2021 | CANCELLED BY INSPECTOR | JGIBSON |
| Note: WRONG INSPECTION SCHEDULED. NO TUB ON SITE TO INSPECT, CHECK FOR WHAT INSPECTION IS BEING SCHEDULED | |||
| ROW - FINAL INSPECTION | 06/21/2021 | APPROVED | KRUTH |
| GRAVITY SEWER TEST | 06/11/2021 | APPROVED | JGIBSON |
| ROW - FINAL INSPECTION | 03/25/2021 | Disapproved - NO FEE | RGROSS |
| Note: Way too much construction materials and outside work going on to do a "Final". No sod placed and obviously no final grade has been completed. | |||
| INSULATION | 12/23/2020 | APPROVED | FWILLIS |
| Note: Insulation only, No Roof Dry-In has been Scheduled for today. | |||
| ALL ROUGH | 12/18/2020 | APPROVED | FWILLIS |
| LATH/BRICK/ WATER BARRIER | 12/14/2020 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/24/2020 | APPROVED | FWILLIS |
| TIE BEAM / LINTEL | 11/02/2020 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 10/29/2020 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 10/19/2020 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION NEED PROOF OF COMPACTION TEST. CALLED CONTRACTOR AND LEFT MESSAGE BEFORE RESULTING. TEMP TOILET…. SANITARY FACILITIES REQUIRED B3305.1 SHALL BE PROVIDED DURING CONSTRUCTION 10/19/20 - Items Corrected. Sanitary being delivered on Wednesday as per contractor will CHECK on next Inspection. | |||
| MONOLITHIC SLAB | 10/16/2020 | Disapproved - NO FEE | FWILLIS |
| Note: NEED PROOF OF COMPACTION TEST. CALLED CONTRACTOR AND LEFT MESSAGE BEFORE RESULTING. TEMP TOILET…. SANITARY FACILITIES REQUIRED B3305.1 SHALL BE PROVIDED DURING CONSTRUCTION | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/13/2020 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | HOLD | 06/21/2021 | 06/21/2021 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM 1. RENAME TO TERMITE.PDF 2. NO FINAL SURVEY SUBMITTED. PLEASE RENAME TO FINAL SURVEY.PDF WHEN RESUBMITTING | |||
| BADMIN | HOLD | 06/21/2021 | 06/21/2021 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 06/21/2021 | 06/21/2021 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 10/27/2020 | 10/27/2020 |
| Note: Released By: JMONTARULI | |||
| ENGIN1 | COMPLETE | 10/27/2020 | 10/29/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 10/27/2020 | 10/28/2020 |
| Note: Released By: TDOAK | |||
| BADMIN | HOLD | 10/26/2020 | 10/26/2020 |
| Note: Held By: STHOMAS RENAME TO FOUNDATION SURVEY. REMOVE ADDRESS FROM FILE NAME | |||
| ELEC | COMPLETE | 08/17/2020 | 08/17/2020 |
| Note: Released By: JMUNSON | |||
| MECH | COMPLETE | 08/17/2020 | 08/17/2020 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 08/17/2020 | 08/21/2020 |
| Note: Released By: FREODICA | |||
| BLD | COMPLETE | 08/17/2020 | 08/21/2020 |
| Note: Released By: FREODICA | |||
| ZON | COMPLETE | 08/13/2020 | 08/13/2020 |
| Note: Released By: TDOAK | |||
| ZON | HOLD | 07/30/2020 | 07/30/2020 |
| Note: Held By: AMOBLEY Please provide a single family dwelling affidavit signed by the owners on the deed and notarized. Then mail original to Attn. Zoning - 160 Lake Ave. Palm Coast, FL 32164 | |||
| BLD | HOLD | 07/30/2020 | 08/06/2020 |
| Note: Held By: FREODICA Provide Florida product approval of soffits, and structural components such as wood connectors, wood anchors, truss plates and linel per FS 553.842. FReodica-386-986-4734 | |||
| ELEC | HOLD | 07/30/2020 | 07/30/2020 |
| Note: Held By: JMUNSON 1.List electrical sub contractor 2.Show exsisiting service size for the house 3. show what size breaker and wire will be running the new panel. 4. need outlet by outside A/C pad NEC 2014 art 210.63 | |||
| MECH | HOLD | 07/30/2020 | 07/30/2020 |
| Note: Held By: CPISCITELLI Energy Calc needs to be signed by the builder | |||
| PLUM | HOLD | 07/30/2020 | 08/06/2020 |
| Note: Held By: FREODICA Provide sanitary riser diagram with signature and license number of plumbing contractor per FBC 6th Ed., Sec 107.2.1. FReodica-386-986-4734 | |||
| BLD | HOLD | 07/22/2020 | 07/23/2020 |
| Note: Held By: LMUSGROVE plans not stamped and need to be submitted single not in one group | |||
| ELEC | HOLD | 07/22/2020 | 07/23/2020 |
| Note: Held By: LMUSGROVE plans not stamped and need to be submitted single not in one group | |||
| MECH | HOLD | 07/22/2020 | 07/23/2020 |
| Note: Held By: LMUSGROVE plans not stamped and need to be submitted single not in one group | |||
| PLUM | HOLD | 07/22/2020 | 07/23/2020 |
| Note: Held By: LMUSGROVE | |||
| SW1 | COMPLETE | 07/22/2020 | 07/23/2020 |
| Note: Released By: CTROHA | |||
| ZON | HOLD | 07/22/2020 | 07/23/2020 |
| Note: Held By: AMOBLEY Please provide a more clear site plan showing addition, breezway widths,walkway widths, material being used and any other improvements being made with this permit. . Keep in mind that a walkway can not exceed 6ft in width. Anything larger will be a patio and must be labeled as that on site plan and will need to meet minimum setbacks. Please provide a single family dwelling affidavit signed by the owners on the deed and notarized. If you need a copy of this form please contact zoning at 386-986-3751 Plans must show all exterior sides. A full elevation page and showing that the finished exterior will match existing |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN FEE | ¤20.00 | 08/24/2020 |
| BUILDING DISCOUNT 100% | (¤559.00) | 08/24/2020 |
| ELECTRIC FEE | ¤93.00 | 08/24/2020 |
| RECORDING FEE REIMBURSE DOC | ¤10.00 | 08/24/2020 |
| MECHANICAL FEE | ¤93.00 | 08/24/2020 |
| PLAN CHECK FEE | ¤40.00 | 08/24/2020 |
| PLUMBING FEE | ¤93.00 | 08/24/2020 |
| REMODEL/ADDITION/ACCES INSPECT | ¤220.00 | 08/24/2020 |
| SITE PLAN 20 | ¤20.00 | 08/24/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/24/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/24/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 08/24/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤114.00 |