I want to search for...
Permit #2020080918
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-00250-0060 |
| CONDITIONED SPACE: 1352 sqft |
| CONDITIONED SPACE: 1352 sqft |
| GARAGE: 448 sqft |
| GARAGE: 448 sqft |
| OPENED PORCH (WITH ROOF) : 113 sqft |
| OPENED PORCH (WITH ROOF) : 113 sqft |
| OPENED PORCH (WITH ROOF) : 34 sqft |
| OPENED PORCH (WITH ROOF) : 34 sqft |
| Total Square Footage: 3894 sqft |
| Block: 00250 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 386-931-5395 |
| Location Address: 2 LYNTON PL |
| Type: DU - DUPLEX |
| Issue Date: 09/04/2020 |
| NOC: RECORDED |
| Applicant name: RYAN JAMES PERRY |
| Owner: BARARADO, OLIVIO & NYDIA |
|
Address 14 COLLEGE CT PALM COAST, FL 32137 |
| Lot: 0060 |
| Contracted Stated Job Value: ¤270,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
WATERSIDE HOMES RENOVATIONS AND DESIGNS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 BISCAYNE DRIVE PALM COAST, FL 32137 |
CBC1263021 (Exp: 08/31/2026) | 386-931-5395 |
Sub Contractors
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone |
| CANCEL |
17 UNIMAY CT BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2022) | 386-931-2568 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
RYAN JAMES PERRY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 BISCAYNE DRIVE PALM COAST, FL 32137 |
CBC1263021 (Exp: 08/31/2026) | 386-931-5395 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/05/2021 | FINAL APPROVED | FWILLIS |
| U -UTILITY RESIDENTIAL FINAL | 04/01/2021 | FINAL APPROVED | DHANEY |
| ROW - FINAL INSPECTION | 03/30/2021 | Disapproved -FEE REQUIRED | KRUTH |
| Note: porta john needs to be either on the driveway or removed from site before final so that area where the facility was can be soded | |||
| ROW - FINAL INSPECTION | 03/30/2021 | APPROVED - AS NOTED | KRUTH |
| Note: THIS IS A REINSPECTION porta john needs to be either on the driveway or removed from site before final so that area where the facility was can be soded corrections made | |||
| U-CROSS CONNECTION | 03/30/2021 | APPROVED | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 03/29/2021 | APPROVED | KRUTH |
| FINAL SURVEY (OFFICE USE ONLY) | 03/29/2021 | APPROVED | KRUTH |
| ROW - FINAL INSPECTION | 03/24/2021 | Disapproved - NO FEE | RGROSS |
| Note: Final Survey no completed yet. | |||
| ELECTRIC - EARLY POWER | 03/11/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 10:45 | |||
| GRAVITY SEWER TEST | 03/04/2021 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 03/04/2021 | APPROVED | JGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 01/22/2021 | Disapproved - NO FEE | RGROSS |
| Note: CULVERT ON THE RIGHT IS LOWER THAN THE CULVERT ON THE LEFT FOR THIS DUPLEX DRIVEWAY. RIGHT SIDE CULVERT IS THE HIGH POINT. HIGH POINT CULVERTS SHOULD NOT BE SET AT THE LOW END TOLERANCE AND CANNOT BE SET 1 1/2 TENTH LOWER THAN THE NEXT CULVERT DOWNSTREAM. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/22/2021 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION CULVERT ON THE RIGHT IS LOWER THAN THE CULVERT ON THE LEFT FOR THIS DUPLEX DRIVEWAY. RIGHT SIDE CULVERT IS THE HIGH POINT. HIGH POINT CULVERTS SHOULD NOT BE SET AT THE LOW END TOLERANCE AND CANNOT BE SET 1 1/2 TENTH LOWER THAN THE NEXT CULVERT DOWNSTREAM. 1/22/21 - THIS WAS RESCHEDULED SAME DAY BY INSPECTOR AS A COURTESY SO BUILDER COULD POUR OVER THE WEEKEND. CORRECTIONS MADE THE SAME DAY. | |||
| PEP TANK INSTALLATION REQUEST | 01/06/2021 | APPROVED | CSTONE |
| LATH/BRICK/ WATER BARRIER | 01/05/2021 | APPROVED | FWILLIS |
| INSULATION | 01/04/2021 | APPROVED | FWILLIS |
| ALL ROUGH | 12/28/2020 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 11/25/2020 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/20/2020 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION need to call in firewall inspection as seperate inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/17/2020 | CANCELLED BY APPLICANT | JCOLASANTI |
| TIE BEAM / LINTEL | 10/15/2020 | APPROVED | JCOLASANTI |
| FOUND SURVEY APPROVED (OFFICE) | 10/13/2020 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 09/29/2020 | APPROVED | JCOLASANTI |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/25/2020 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 09/15/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ZON | HOLD | 02/26/2021 | 02/26/2021 |
| Note: Held By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM Please revise color sheet to remove the original colors submittal. | |||
| ZON | COMPLETE | 02/26/2021 | 03/01/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/09/2020 | 10/13/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 10/09/2020 | 10/09/2020 |
| Note: Released By: TDOAK | |||
| ZON | COMPLETE | 08/26/2020 | 08/27/2020 |
| Note: Released By: ELENS | |||
| BLD | COMPLETE | 08/26/2020 | 09/01/2020 |
| Note: Released By: JPI | |||
| UTL | COMPLETE | 08/26/2020 | 08/31/2020 |
| Note: Released By: LFITZGERALD | |||
| ENGIN1 | COMPLETE | 08/26/2020 | 08/27/2020 |
| Note: Released By: TBAKER | |||
| SW1 | COMPLETE | 08/26/2020 | 08/28/2020 |
| Note: Released By: CTROHA | |||
| BLD | HOLD | 08/19/2020 | 08/21/2020 |
| Note: Held By: JPI 1. Missing items from PA spec sheet: mullions, Zip system and roof vent. 2. Please size of attic access per FRC 807. 3. Provide UL # for block portion of demising wall. 4. Provide splicing distance and mating details for double top plate of bearing wall. 5. For all attachment of wood framing to masonry, please call out distance from edge of member for first fastener. IE: Fastener start @ 6” from splice and edge of wood member. 6. Product approval sheet calls out for OSB for roof. Plans illustrate Zip System. Clarify. 7. Provide section thru garage to dwelling wall to illustrate compliance with R302.6 Separation, or provide note to that effect. 8. Provide a written response to the comments with revisions clouded on plan and page numbers of new details provided. | |||
| CUSVC | COMPLETE | 08/19/2020 | 08/20/2020 |
| Note: Released By: HHAND | |||
| ELEC | COMPLETE | 08/19/2020 | 08/20/2020 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 08/19/2020 | 08/19/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 08/19/2020 | 08/21/2020 |
| Note: Released By: CSTONE | |||
| MECH | COMPLETE | 08/19/2020 | 08/20/2020 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 08/19/2020 | 08/21/2020 |
| Note: Released By: JPI | |||
| SW1 | COMPLETE | 08/19/2020 | 08/21/2020 |
| Note: Released By: CTROHA | |||
| UTL | COMPLETE | 08/19/2020 | 08/25/2020 |
| Note: Released By: LFITZGERALD | |||
| ZON | HOLD | 08/19/2020 | 08/19/2020 |
| Note: Held By: ELENS 8 foundation plantings/shrubs are required within 8 feet of the front facade. The landscape plan legend is cut off. Please upload it so that it is visible. Please complete the color sheet including: Name and LRV of the exterior paint color, the material of the exterior, the number of accent colors, and roof color. The location of the A/C pads on the floor plan do not match the site plan and landscape plan. Banding is required on the windows on the right side facing the public right of way. | |||
| SWALE | COMPLETE | 08/19/2020 | 09/14/2020 |
| Note: Released By: TBAKER |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| STORMWATER REINSPECTION FEE | ¤40.00 | 04/05/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤77.94) | 09/04/2020 |
| SEWER CREDIT | (¤1,700.00) | 09/04/2020 |
| SEWER INSPECTION | ¤25.00 | 09/04/2020 |
| SEWER CAPITAL FACILITY | ¤9,192.14 | 09/04/2020 |
| WATER CAPITAL FACILITY FEE | ¤6,748.36 | 09/04/2020 |
| METER - DEPOSIT | ¤120.00 | 09/04/2020 |
| WATER- TURN ON | ¤50.00 | 09/04/2020 |
| ADMIN FEE | ¤20.00 | 09/04/2020 |
| CONNECTION FEES | ¤2,005.76 | 09/04/2020 |
| BUILDING DISCOUNT 100% | (¤1,665.80) | 09/04/2020 |
| ELECTRIC FEE | ¤269.40 | 09/04/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤13.40) | 09/04/2020 |
| IMPACT FEE FIRE | ¤446.76 | 09/04/2020 |
| IMPACT FEE PARKS | ¤1,698.48 | 09/04/2020 |
| IMPACT FEE SCHOOL | ¤7,200.00 | 09/04/2020 |
| IMPACT FEE TRANSPORTATION | ¤2,598.00 | 09/04/2020 |
| MECHANICAL FEE | ¤269.40 | 09/04/2020 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 09/04/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤50.95) | 09/04/2020 |
| PLAN CHECK FEE | ¤139.60 | 09/04/2020 |
| PLUMBING FEE | ¤269.40 | 09/04/2020 |
| NEW RESIDENTIAL INSPECTIONS | ¤698.00 | 09/04/2020 |
| SITE PLAN 20 | ¤20.00 | 09/04/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/04/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 09/04/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/04/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤28,436.21 |