I want to search for...

Permit #2020081114

Permit Details

Status: COED

Parcel Id: 07-11-31-7059-00330-0120
CONDITIONED SPACE: 1245 sqft
GARAGE: 521 sqft
OPENED PORCH (WITH ROOF) : 225 sqft
OPENED PORCH (WITH ROOF) : 42 sqft
Total Square Footage: 2033 sqft
Block: 00330
Subdivision: 2211 - SECTION 59-SEMINOLE PARK
Job Phone: 386-447-4151
Location Address: 4 SEAFARING PATH
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/09/2020
NOC: RECORDED
Applicant name: GENE WARREN SLONE
Owner: LAMBERT, JUDY N

Address

2318 SHOAL CREEK DR

PENSACOLA, FL 32514

Lot: 0120
Contracted Stated Job Value: ¤160,000.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

FLORIDA GREEN CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

870 E RETTA STREET

DELEON SPRINGS, FL 32130

CBC1260957 (Exp: 08/31/2026) 407-580-2657

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
GREGG A MCANALLY
Status Location Address State License Number Phone
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

PALM COAST, FL 32092

CAC1815760 (Exp: 08/31/2022) 904-829-8898
ERIC FRANCO
Status Location Address State License Number Phone
CANCEL

840 DELTONA BLVD SUITE F-2

SANFORD, FL 32771

CCC1327280 (Exp: 08/31/2022) 386-575-4007

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/05/2021 FINAL APPROVED TSTAUFFACHER
U-CROSS CONNECTION 06/23/2021 APPROVED - AS NOTED JHARDING
Note: No cross connections
U -UTILITY RESIDENTIAL FINAL 06/22/2021 FINAL APPROVED JHARDING
ROW - STORMWATER FINAL 06/21/2021 APPROVED RGROSS
ROW - FINAL APRON (AFTER POUR) 06/21/2021 APPROVED RGROSS
ROW FIELD SURVEY /GRADING CERTIFICATION 06/14/2021 APPROVED RGROSS
FINAL SURVEY (OFFICE USE ONLY) 06/14/2021 APPROVED RGROSS
ELECTRIC - EARLY POWER 05/28/2021 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 8:50
ROW- PRE-APRON (PRE-POUR) 05/05/2021 APPROVED RGROSS
Note: NOTE: This was resulted while at 28 Graham woods Pl. The real time for this inspection was AM 9:13 - 9:20
U - SEWER TIE IN 04/27/2021 APPROVED JGIBSON
GRAVITY SEWER TEST 04/27/2021 APPROVED JGIBSON
PEP TANK INSTALLATION REQUEST 04/05/2021 APPROVED CSTONE
LATH/BRICK/ WATER BARRIER 03/22/2021 APPROVED TSTAUFFACHER
INSULATION 02/25/2021 APPROVED TSTAUFFACHER
ALL ROUGH 02/22/2021 APPROVED TSTAUFFACHER
ELECTRIC TEMP POLE 01/26/2021 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 9:15 am
ROOF VALLEY & METAL 01/21/2021 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/19/2021 APPROVED TSTAUFFACHER
TIE BEAM / LINTEL 01/06/2021 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION missing filled cell n front proch per foundation plan (highlighted)
FOUND SURVEY APPROVED (OFFICE) 01/05/2021 APPROVED TBAKER
TIE BEAM / LINTEL 12/18/2020 Disapproved -FEE REQUIRED WMILLER
Note: missing filled cell n front proch per foundation plan (highlighted)
MONOLITHIC SLAB 12/10/2020 APPROVED TSTAUFFACHER
PLUMBING 1ST ROUGH UNDERGROUND 12/03/2020 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 10/23/2020 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 01/04/2021 01/05/2021
Note: Released By: TBAKER
ZON COMPLETE 01/04/2021 01/04/2021
Note: Released By: TDOAK
PLENV COMPLETE 10/06/2020 10/06/2020
Note: Released By: JMYERS The Approved After Action Report has been accepted.
PLENV HOLD 09/22/2020 09/22/2020
Note: Held By: JMYERS Staff has been made aware that there are Gopher Tortoise on the property. Please provide the approved After Action Report from FWC.
ZON COMPLETE 09/08/2020 09/08/2020
Note: Released By: ELENS
ELEC COMPLETE 09/03/2020 09/03/2020
Note: Released By: JMUNSON
ZON HOLD 09/03/2020 09/03/2020
Note: Held By: ELENS Repeat comment: Please show A/C pad on the site plan.
BLD COMPLETE 09/03/2020 09/09/2020
Note: Released By: JPI
PLUM COMPLETE 09/03/2020 09/09/2020
Note: Released By: JPI
MECH CANCEL 09/03/2020 09/04/2020
Note: not needed
UTL COMPLETE 09/03/2020 09/09/2020
Note: Released By: LFITZGERALD
SW1 COMPLETE 09/03/2020 09/04/2020
Note: Released By: CTROHA
ENGIN1 COMPLETE 09/03/2020 09/03/2020
Note: Released By: TBAKER
SWALE COMPLETE 08/25/2020 09/23/2020
Note: Released By: TBAKER
BLD HOLD 08/24/2020 08/31/2020
Note: Held By: JPI 1. On building section on page 4, please provide full structural construction details on section cut through front covered entry. Detail all connections and method of attachments. Please include any box framing. R301. 2. Provide beam mating details for beams at front entry. 3. Knee wall detail does not match detail or layout shown in cross section on page 4. 4. Provide beam attachment details to structure. 5. Provide full structural construction details with all attachments for valley truss. R301. 6. Provide a written response to the comments with revisions clouded on plan and page numbers of new details provided.
CUSVC COMPLETE 08/24/2020 08/26/2020
Note: Released By: HHAND
ELEC HOLD 08/24/2020 08/25/2020
Note: Held By: JMUNSON 1. Need kitchen outlets. NEC 2014 210.52 2. Need outlet in bedroom on garage wall. NEC 2014 210.52
ENGIN1 COMPLETE 08/24/2020 08/25/2020
Note: Released By: TBAKER
LOCATE COMPLETE 08/24/2020 08/27/2020
Note: Released By: CSTONE
MECH COMPLETE 08/24/2020 08/25/2020
Note: Released By: CPISCITELLI
PLUM HOLD 08/24/2020 08/31/2020
Note: Held By: JPI 1. Plumbing isometric illustrates double lavatories in master bath. Floor plans indicate one lavatory. Clarify/correct.
SW1 COMPLETE 08/24/2020 08/25/2020
Note: Released By: CTROHA
UTL COMPLETE 08/24/2020 08/28/2020
Note: Released By: LFITZGERALD
ZON HOLD 08/24/2020 08/25/2020
Note: Held By: ELENS Please show A/C pad on the site plan.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION FEE ¤40.00 08/12/2021
NEW RESIDENTIAL INSPECTIONS ¤342.00 10/09/2020
SITE PLAN 20 ¤20.00 10/09/2020
SURCHARGE FS 533.721 ¤2.00 10/09/2020
SURCHARGE - FS 468.631 ¤2.00 10/09/2020
STORM WATER PERMIT FEES ¤80.00 10/09/2020
3% TRANS IMPACT FEE CREDIT (¤50.22) 10/09/2020
SEWER INSPECTION ¤25.00 10/09/2020
SEWER CAPITAL FACILITY ¤4,596.07 10/09/2020
WATER CAPITAL FACILITY FEE ¤3,374.18 10/09/2020
METER - DEPOSIT ¤60.00 10/09/2020
WATER- TURN ON ¤25.00 10/09/2020
ADMIN FEE ¤20.00 10/09/2020
CONNECTION FEES ¤1,002.88 10/09/2020
BUILDING DISCOUNT 100% (¤918.20) 10/09/2020
ELECTRIC FEE ¤162.60 10/09/2020
3% FIRE IMPACT FEE CREDIT (¤6.70) 10/09/2020
IMPACT FEE FIRE ¤223.38 10/09/2020
IMPACT FEE PARKS ¤849.24 10/09/2020
IMPACT FEE SCHOOL ¤3,600.00 10/09/2020
IMPACT FEE TRANSPORTATION ¤1,674.00 10/09/2020
MECHANICAL FEE ¤162.60 10/09/2020
WATER -IRRIGATION INSPECTION ¤25.00 10/09/2020
3% PARKS IMPACT FEE CREDIT (¤25.48) 10/09/2020
PLAN CHECK FEE ¤68.40 10/09/2020
PLUMBING FEE ¤162.60 10/09/2020
Fees Total Due: ¤0.00 Total Paid: ¤15,516.35