I want to search for...

Permit #2020081271

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7016-00040-0890
Block: 00040
Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE
Job Phone: 386-627-8289
Location Address: 16 CONTEE CT
Type: BH - BOATHOUSE
Issue Date: 01/21/2021
NOC: RECORDED
Applicant name: ROBERT E WILLIAMS
Owner: O'HAGAN JAMES & DONNA M H&W

Address

21 SHALLOW STREAM RD

CARAMEL, NY 10512

Lot: 0890
Contracted Stated Job Value: ¤21,500.00
Job Description: BOATHOUSE
Type: CN

Contractor

ELITE MARINE CONSTRUCTION LLC
Status Location Address Phone
CANCEL

12 COCONUT CT

PALM COAST, FL 32137

386-627-8289

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 03/04/2021 FINAL APPROVED MMESSER

Review History

Department Status Date In Date Out
ZON COMPLETE 01/05/2021 01/05/2021
Note: Released By: TDOAK
BLD COMPLETE 01/05/2021 01/12/2021
Note: Released By: FREODICA
ZON HOLD 10/20/2020 10/20/2020
Note: Held By: TDOAK Please double check the dimensions of the roof on the framing plan. You indicate that the roof will only extend 12' into the waterbody on the engineered dock/boat house layout of which the total projection into the waterbody must include the overhang), yet the framing plan shows the total width to be 14'.
BLD HOLD 10/20/2020 10/27/2020
Note: Held By: FREODICA Repeat comment 2b: 2. Clafify the following Plan Section and Details per FBC 6th Ed. Sec. 107.2.1. b. Detail 6: Wood Beam and Rafter Detail Connectors/fasteners of roof rafter and roof beam are missing. FReodica -386-986-4734
ZON HOLD 09/11/2020 09/11/2020
Note: Held By: TDOAK Please double check the dimensions of the roof on the framing plan. You indicate that the roof will only extend 12' into the waterbody on the engineered dock/boat house layout of which the total projection into the waterbody must include the overhang), yet the framing plan shows the total width to be 14'.
BLD HOLD 09/11/2020 09/18/2020
Note: Held By: FREODICA 1. Provide Florida product approval of roofing material and underlayment to be used per FS 553.842. 2. Clafify the following Plan Section and Details per FBC 6th Ed. Sec. 107.2.1. a. Section 7: Post size below deck shows 8 inches in diameter but above deck shows 9 inches and 10 inches in diamter. b. Detail 6: Wood Beam and Rafter Detail Connectors/fasteners of roof rafter and roof beam are missing. FReodica -386-986-4734
ZON HOLD 09/03/2020 09/03/2020
Note: Held By: TDOAK 1. Engineered drawings must note the total height of the roof from the seawall cap. 2. Plans must state that the proposed roof will match the house. 3. The roof framing plan must note the width of the roof. It only shows the length.
BLD HOLD 09/03/2020 09/11/2020
Note: Held By: FREODICA Coordinate permit application, site plan and engineering plans for clarity per FBC 6th Ed. Sec. 107.2.1. Please note that you cannot have (2) engineers of record for the same job. FReodica -386-986-4734
ZON HOLD 08/31/2020 08/31/2020
Note: Held By: TDOAK Aerial photo of property depicts an existing boat house and dock. Does this boat house still exist? If it is still existing, the site plan must show all existing improvements (Include dimensions and setbacks of existing dock/boat house.. AS PER EMAIL FROM CONTRACTOR THERE IS NO BOAT HOUSE OR DOCK EXISTING ON THIS PROPERTY. Engineered plans submitted do not match the proposed boat house as submitted on site plan. Unable to complete zoning review without correct engineered drawings.
ZON HOLD 08/27/2020 08/27/2020
Note: Held By: TDOAK Aerial photo of property depicts an existing boat house and dock. Does this boat house still exist? If it is still existing, the site plan must show all existing improvements (Include dimensions and setbacks of existing dock/boat house. Engineered plans submitted do not match the proposed boat house as submitted on site plan. Unable to complete zoning review without correct engineered drawings.
BLD HOLD 08/26/2020 09/02/2020
Note: Held By: FREODICA Provide boathouse plan per permit application and to match dimensions with site plan for clarity per FBC 6th Ed. Sec. 107.2.1. FReodica - 386-986-4734

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 01/21/2021
BUILDING DISCOUNT 100% (¤146.00) 01/21/2021
RECORDING FEE REIMBURSE DOC ¤78.00 01/21/2021
PLAN CHECK FEE ¤40.00 01/21/2021
REMODEL/ADDITION/ACCES INSPECT ¤86.00 01/21/2021
SURCHARGE FS 533.721 ¤2.00 01/21/2021
SURCHARGE - FS 468.631 ¤2.00 01/21/2021
STORM WATER PERMIT FEES ¤80.00 01/21/2021
Fees Total Due: ¤0.00 Total Paid: ¤162.00