I want to search for...
Permit #2020081274
Permit Details
Status: COED
| Parcel Id: 07-11-31-7004-00220-0340 |
| CONDITIONED SPACE: 2173 sqft |
| GARAGE: 506 sqft |
| OPENED PORCH (WITH ROOF) : 216 sqft |
| OPENED PORCH (WITH ROOF) : 88 sqft |
| Total Square Footage: 2983 sqft |
| Block: 00220 |
| Subdivision: 2203 - SECTION 4-COUNTRY CLUB COVE |
| Job Phone: 386-931-5395 |
| Location Address: 2 CORMORANT CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/30/2020 |
| NOC: RECORDED |
| Applicant name: RYAN JAMES PERRY |
| Owner: GARDNER, ASHLEY & CAROL |
|
Address 3010 CAMP RANGER LN JAMESTOWN, NC 27282 |
| Lot: 0340 |
| Contracted Stated Job Value: ¤290,000.00 |
| Job Description: SINGLE FAMILY RESIDENTIAL |
| Type: CN |
Contractor
WATERSIDE HOMES RENOVATIONS AND DESIGNS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 BISCAYNE DRIVE PALM COAST, FL 32137 |
CBC1263021 (Exp: 08/31/2026) | 386-931-5395 |
Sub Contractors
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
PETER JOSEPH LYDEN
| Status | Location Address | State License Number | Phone |
| CANCEL |
17 UNIMAY CT BUNNELL, FL 32110 |
EC0002436 (Exp: 08/31/2022) | 386-931-2568 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
RYAN JAMES PERRY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 BISCAYNE DRIVE PALM COAST, FL 32137 |
CBC1263021 (Exp: 08/31/2026) | 386-931-5395 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 06/29/2021 | CANCELLED BY APPLICANT | WEB |
| BLD - BUILDING FINAL | 06/29/2021 | FINAL APPROVED | WMILLER |
| ROW - FINAL APRON (AFTER POUR) | 06/29/2021 | APPROVED | KRUTH |
| Note: culvert elevation is good | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/29/2021 | APPROVED | KRUTH |
| ROW - STORMWATER FINAL | 06/29/2021 | APPROVED | KRUTH |
| U -UTILITY RESIDENTIAL FINAL | 06/29/2021 | FINAL APPROVED | JHARDING |
| U-CROSS CONNECTION | 06/28/2021 | APPROVED - AS NOTED | JHARDING |
| Note: No cross connections. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/28/2021 | APPROVED | GBERTOLA |
| ELECTRIC - EARLY POWER | 06/15/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 10:15 | |||
| ROW- PRE-APRON (PRE-POUR) | 06/04/2021 | APPROVED - AS NOTED | KRUTH |
| Note: pipe is good It is the BUILDER'S RESPONSIBILITY: to recheck elevations and pipe size, to insure that an obstruction does not exist upstream and or downstream, that the culvert pipe is set to and or follows the swale plan, form the driveway to the approved site plan and follow the approved driveway detail sheet provided by the City of Palm Coast. PRIOR to placement of concrete. | |||
| U - SEWER TIE IN | 05/27/2021 | APPROVED | JGIBSON |
| GRAVITY SEWER TEST | 05/27/2021 | APPROVED | JGIBSON |
| PROJECT STATUS (OFFICE USE) | 03/12/2021 | APPROVED - AS NOTED | RGROSS |
| Note: Silt fence at the seawall cannot be collapsed. 3/12/21 - Silt fence stabilized. | |||
| INSULATION | 02/22/2021 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION NEED FIREBLOCKING AT AREAS HIGHLIGHTED ON FLOOR PLAN 02-22-21... deficiencies noted above resolved | |||
| INSULATION | 02/19/2021 | Disapproved - NO FEE | WMILLER |
| Note: NEED FIREBLOCKING AT AREAS HIGHLIGHTED ON FLOOR PLAN | |||
| INSULATION | 02/18/2021 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 02/12/2021 | APPROVED | FWILLIS |
| ALL ROUGH | 02/10/2021 | APPROVED | TSTAUFFACHER |
| ELECTRIC-TUG | 02/08/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 11:30 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/01/2021 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION truss A13, and A18 not per engineers specs see highlighted. missing double girder and HUS's in garage per plans | |||
| ROOF VALLEY & METAL | 02/01/2021 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION 1. must pass roof sheathing/braces/ties/down cells prior 2. VALLEY FLASHING, R905.2.8.2 (complete roof valley linings per code) (need to use proper material) 3. VENT STACKS/PIPES FBC, R, P3103.1 MUST TERMINATE NOT LESS THAN 6 INCHES ABOVE THE ROOF | |||
| ROOF VALLEY & METAL | 01/29/2021 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. must pass roof sheathing/braces/ties/down cells prior 2. VALLEY FLASHING, R905.2.8.2 (complete roof valley linings per code) (need to use proper material) 3. VENT STACKS/PIPES FBC, R, P3103.1 MUST TERMINATE NOT LESS THAN 6 INCHES ABOVE THE ROOF | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/21/2021 | Disapproved -FEE REQUIRED | WMILLER |
| Note: truss A13, and A18 not per engineers specs see highlighted. missing double girder and HUS's in garage per plans | |||
| TIE BEAM / LINTEL | 12/11/2020 | APPROVED | TSTAUFFACHER |
| FOUND SURVEY APPROVED (OFFICE) | 12/10/2020 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 11/17/2020 | APPROVED | TSTAUFFACHER |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/12/2020 | APPROVED | JGIBSON |
| STEM WALL FOUNDATION | 11/02/2020 | APPROVED | WMILLER |
| WATER METER INSTALLATION REQUEST | 10/26/2020 | APPROVED | CSTONE |
| FOOTER | 10/22/2020 | APPROVED | MMESSER |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 03/08/2021 | 03/08/2021 |
| Note: Released By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/26/2021 | 02/01/2021 |
| Note: Released By: FREODICA Revision - changed truss layout. | |||
| BLD | COMPLETE | 01/12/2021 | 01/20/2021 |
| Note: Released By: FREODICA Revision - truss repair on truss A-13 -18. | |||
| ENGIN1 | COMPLETE | 12/09/2020 | 12/10/2020 |
| Note: Released By: TBAKER | |||
| ZON | COMPLETE | 12/09/2020 | 12/09/2020 |
| Note: Released By: TDOAK | |||
| BLD | COMPLETE | 10/22/2020 | 10/30/2020 |
| Note: Released By: PBUCKLEY | |||
| ZON | COMPLETE | 09/14/2020 | 09/14/2020 |
| Note: Released By: ELENS | |||
| SW1 | COMPLETE | 09/08/2020 | 09/08/2020 |
| Note: Released By: GBERTOLA | |||
| MECH | HOLD | 09/04/2020 | 09/08/2020 |
| Note: Held By: CPISCITELLI Energy Calcs and EPL card need to be signed by the builder. (Second Request) | |||
| PLFM | COMPLETE | 09/04/2020 | 09/04/2020 |
| Note: Released By: JMYERS According to the Site Plan submitted on 9/4/2020 the structure will be outside of the SFHA. No elevation certificates will be required. | |||
| ZON | HOLD | 09/04/2020 | 09/04/2020 |
| Note: Held By: ELENS House is flipped on site plan and floor plan. Please resubmit landscape plan to match. Please note that 8 foundation plantings/shrubs are required across the front, 6 are required on the right, facing the public right of way, and 4 are required on the left - in addition to the A/C being screened with 7 gallon shrubs. (They must wrap the corners of the house.) Repeat comments: No exterior color is given on the color sheet. The elevations show two exterior materials. Please list both exteriors on the color sheet with their colors. (Please note that only one exterior color is allowed, so they must match.) Please note that windows and doors facing a public right of way must be banded. (Right side windows.) | |||
| PLUM | COMPLETE | 09/04/2020 | 09/10/2020 |
| Note: Released By: JPI | |||
| BLD | COMPLETE | 09/04/2020 | 09/10/2020 |
| Note: Released By: JPI | |||
| ENGIN1 | COMPLETE | 09/04/2020 | 09/08/2020 |
| Note: Released By: TBAKER | |||
| UTL | COMPLETE | 09/04/2020 | 09/10/2020 |
| Note: Released By: LFITZGERALD | |||
| MECH | COMPLETE | 09/01/2020 | 09/08/2020 |
| Note: Released By: CPISCITELLI | |||
| PLFM | HOLD | 08/28/2020 | 08/28/2020 |
| Note: Held By: JMYERS The survey and the site plan show an "Approximate Flood Zone Line". This is not sufficient to determine if the structure is in a flood zone or not. Please provide a revised survey and site plan that shows the exact location of the flood zones on the property. | |||
| SWALE | COMPLETE | 08/27/2020 | 10/01/2020 |
| Note: Released By: TBAKER | |||
| BLD | HOLD | 08/26/2020 | 09/03/2020 |
| Note: Held By: JPI 1. Please provide length of attic access per FRC 807. 2. Provide location of summer kitchen on floor plans. 3. Provide roof ventilation calculations, per R806. 4. Provide full structural construction details for any conventional roof framing, such as valley framing, with all attachments illustrated. Entry and bedroom appear to have areas of conventional framing. 5. Footing plans call for Type 3 footing at front entry. That per table is the garage footing. Clarify footing type. 6. Identify footing type from garage to dwelling. Plans indicate a 4” stepdown. 7. Provide section thru garage to dwelling wall to illustrate compliance with R302.6 Separation or provide notes to that effect. 8. Provide a written response to the comments with revisions clouded on plan and page numbers of new details provided. | |||
| CUSVC | COMPLETE | 08/26/2020 | 09/01/2020 |
| Note: Released By: HHAND | |||
| ELEC | COMPLETE | 08/26/2020 | 08/28/2020 |
| Note: Released By: JMUNSON | |||
| ENGIN1 | COMPLETE | 08/26/2020 | 08/27/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 08/26/2020 | 08/28/2020 |
| Note: Released By: CSTONE | |||
| MECH | HOLD | 08/26/2020 | 08/28/2020 |
| Note: Held By: CPISCITELLI 1. Plans show R38 with a vented attic. Energy calcs show R20 at roof deck with non vented attic. Revise to match 2. Energy Calcs and EPL card need to be signed by the builder | |||
| PLUM | HOLD | 08/26/2020 | 09/03/2020 |
| Note: Held By: JPI 1. Isometric indicates a tub in master bath. Plans do not illustrate a tub. 2. No indication of summer kitchen location on floor plans. | |||
| SW1 | COMPLETE | 08/26/2020 | 08/28/2020 |
| Note: Released By: CTROHA | |||
| UTL | COMPLETE | 08/26/2020 | 09/01/2020 |
| Note: Released By: LFITZGERALD | |||
| ZON | HOLD | 08/26/2020 | 08/28/2020 |
| Note: Held By: ELENS Please add shrubs (foundation plantings) to wrap the right front corner of the residence. No exterior color is given on the color sheet. The elevations show two exterior materials. Please list both exteriors on the color sheet with their colors. (Please note that only one exterior color is allowed, so they must match.) Windowless walls are prohibited facing a public right of way. (right side) (Please note that windows and doors facing a public right of way must be banded.) |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REVISION | ¤40.00 | 06/29/2021 |
| REVISION | ¤40.00 | 06/29/2021 |
| REINSPECTION FEE | ¤40.00 | 06/29/2021 |
| REINSPECTION FEE | ¤40.00 | 06/29/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤580.00 | 09/30/2020 |
| SITE PLAN 20 | ¤20.00 | 09/30/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/30/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 09/30/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/30/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 09/30/2020 |
| SEWER INSPECTION | ¤25.00 | 09/30/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 09/30/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 09/30/2020 |
| METER - DEPOSIT | ¤60.00 | 09/30/2020 |
| WATER- TURN ON | ¤25.00 | 09/30/2020 |
| ADMIN FEE | ¤20.00 | 09/30/2020 |
| CONNECTION FEES | ¤1,002.88 | 09/30/2020 |
| BUILDING DISCOUNT 100% | (¤1,418.00) | 09/30/2020 |
| ELECTRIC FEE | ¤234.00 | 09/30/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 09/30/2020 |
| IMPACT FEE FIRE | ¤223.38 | 09/30/2020 |
| IMPACT FEE PARKS | ¤849.24 | 09/30/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/30/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 09/30/2020 |
| MECHANICAL FEE | ¤234.00 | 09/30/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/30/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 09/30/2020 |
| PLAN CHECK FEE | ¤116.00 | 09/30/2020 |
| PLUMBING FEE | ¤234.00 | 09/30/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,636.35 |