Permit #2020081420
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00530-0190 |
| CONDITIONED SPACE: 1502 sqft |
| GARAGE: 454 sqft |
| OPENED PORCH (WITH ROOF) : 168 sqft |
| OPENED PORCH (WITH ROOF) : 40 sqft |
| OPENED PORCH (WITH ROOF) : 88 sqft |
| CONDITIONED SPACE: 167 sqft |
| OPENED PORCH (WITH ROOF) : 94 sqft |
| Total Square Footage: 2513 sqft |
| Block: 00530 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 386-313-6950 |
| Location Address: 17 WHEELER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/20/2020 |
| NOC: RECORDED |
| Applicant name: MARK ANTHONY LANGELLO |
| Owner: FLAGLER SELECT PROPERTIES LLC |
|
Address UNIT 58 BUNNELL, FL 32110 |
|
Address 2323 N STATE BUNNELL, FL 32110 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
M & M DEVELOPMENT & CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
2323 N. STATE ST BUNNELL, FL 32110 |
RG291103911 (Exp: 08/31/2023) | 386-313-6950 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
MICHAEL FRANK MORELLO
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 HARGROVE GRADE PALM COAST, FL 32164 |
CAC1819466 (Exp: 08/31/2026) | 386-445-5023 | 386-446-4614 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/24/2021 | FINAL APPROVED | KSANDOE |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Termite cert needs to be affixed to the electrical panel. Energy calculations, model numbers did not match installed units. Submit revised energy calcs to the city for approval Cannot hand write model numbers for equipment | |||
| BLD - BUILDING FINAL | 11/19/2021 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: THIS IS A REINSPECTION Termite cert needs to be affixed to the electrical panel. Energy calculations, model numbers did not match installed units. Submit revised energy calcs to the city for approval Cannot hand write model numbers for equipment | |||
| BLD - BUILDING FINAL | 11/18/2021 | Disapproved - NO FEE | JWALKER |
| Note: Termite cert needs to be affixed to the electrical panel. Energy calculations, model numbers did not match installed units. | |||
| U -UTILITY RESIDENTIAL FINAL | 11/18/2021 | FINAL APPROVED | LFITZGERALD |
| Note: THIS IS A REINSPECTION no power to house-no power to pep tank/circuit breakers not installed yet | |||
| ELECTRIC - EARLY POWER | 11/08/2021 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 8:53 am | |||
| ROW - STORMWATER FINAL | 11/03/2021 | APPROVED | KRUTH |
| U -UTILITY RESIDENTIAL FINAL | 11/03/2021 | Disapproved - NO FEE | LFITZGERALD |
| Note: no power to house-no power to pep tank/circuit breakers not installed yet | |||
| ROW - FINAL APRON (AFTER POUR) | 11/03/2021 | APPROVED | KRUTH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/11/2021 | APPROVED | KRUTH |
| FINAL SURVEY (OFFICE USE ONLY) | 10/11/2021 | APPROVED | KRUTH |
| GRAVITY SEWER TEST | 07/14/2021 | APPROVED | JGIBSON |
| U - SEWER TIE IN | 07/14/2021 | APPROVED | JGIBSON |
| ROW- PRE-APRON (PRE-POUR) | 07/08/2021 | APPROVED - AS NOTED | RGROSS |
| Note: THIS IS A REINSPECTION 7/8/21 - On site with builder as adjustment were made to the culvert elevation. Pipe floated overnight. READY TO POUR at the time of inspection. Heavy rain in the forecast. Builder advised to double check elevation before pouring. | |||
| ROW- PRE-APRON (PRE-POUR) | 07/06/2021 | CANCELLED BY APPLICANT | RGROSS |
| PEP TANK INSTALLATION REQUEST | 06/02/2021 | APPROVED | CSTONE |
| INSULATION | 05/21/2021 | APPROVED | JWALKER |
| ROOF VALLEY & METAL | 05/20/2021 | APPROVED - AS NOTED | JWALKER |
| Note: THIS IS A REINSPECTION The frist row of the modifided bitumen self adhearing the plastic was not remove allowning the underlament to adhere to the plywood aroung the whole perimeter of the building. There also appears to be a manufactures defect of the underlayment and the to plastic coating is peeling away. Metal roofing of the building was in process. Upon conversation with the builder Mark. He did submitt a letter from manufacture to the building dept about the underlayment defect and is awiting approval. I told him it was ok to prceed with installation at his risk of the letter being rejected. He agreed . The modifided bitumen self adhearing first row was reinspected and fastened properly. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/20/2021 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Truss spacing inbetween AT01 and GDR1 is greater than 2' o.c. print does not show a truss in that space. However spacing is greater than the 2' o.c. max spacing for trusses. R802.10 Confirm all VGT w/hold downs nuts are tightened properly. | |||
| ROOF VALLEY & METAL | 05/19/2021 | Disapproved - NO FEE | JWALKER |
| Note: The frist row of the modifided bitumen self adhearing the plastic was not remove allowning the underlament to adhere to the plywood aroung the whole perimeter of the building. There also appears to be a manufactures defect of the underlayment and the to plastic coating is peeling away. | |||
| ALL ROUGH | 05/18/2021 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Missing nail plates through out. Windows need to be fasten 4" from edge. 8" O.C. per manufactures specs Secure water supply line at tub. Electrical panel needs boxed/framed out to protect conduit. Ground rod not connected to UFER. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/11/2021 | Disapproved - NO FEE | JWALKER |
| Note: Truss spacing inbetween AT01 and GDR1 is greater than 2' o.c. print does not show a truss in that space. However spacing is greater than the 2' o.c. max spacing for trusses. R803 Confirm all VGT w/hold downs nuts are tightened properly. | |||
| ALL ROUGH | 05/11/2021 | Disapproved - NO FEE | JWALKER |
| Note: Missing nail plates through out. Windows need to be fasten 4" from edge. 8" O.C. per manufactures specs Secure water supply line at tub. Electrical panel needs boxed/framed out to protect conduit. Ground rod not connected to UFER. Dryer duct at 45 degree bend needs to be sealed | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/10/2021 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 05/04/2021 | APPROVED | MMESSER |
| Note: THIS IS A REINSPECTION Need compaction report. | |||
| U-CROSS CONNECTION | 04/01/2021 | APPROVED - AS NOTED | DHANEY |
| Note: Approved No IRR. No Cross CN | |||
| LATH/BRICK/ WATER BARRIER | 03/25/2021 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION All banding and cornerbead needs to be installed for inspection 03-25-21... notes above resolved | |||
| LATH/BRICK/ WATER BARRIER | 03/22/2021 | Disapproved -FEE REQUIRED | JBODEN |
| Note: All banding and cornerbead needs to be installed for inspection | |||
| TIE BEAM / LINTEL | 01/13/2021 | APPROVED | MMESSER |
| MONOLITHIC SLAB | 01/04/2021 | Disapproved - NO FEE | MMESSER |
| Note: Need compaction report. | |||
| ELECTRIC TEMP POLE | 12/14/2020 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 9:50 | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 12/03/2020 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 11/04/2020 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 11/22/2021 | 11/22/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 11/19/2021 | 11/19/2021 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Square footage on Energy calcs and heatload does not match the plans. Revise to match 2. Energy calcs need to be signed by the builder | |||
| BLD | COMPLETE | 05/17/2021 | 05/19/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/10/2021 | 05/10/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/10/2021 | 05/10/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/04/2021 | 05/05/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/04/2021 | 05/04/2021 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM House does not meet minimum 25' front setback. | |||
| SW1 | COMPLETE | 12/09/2020 | 12/09/2020 |
| Note: Released By: GBERTOLA | |||
| BLD | COMPLETE | 12/04/2020 | 12/09/2020 |
| Note: Released By: FREODICA Revision 3 - changed dimensions of the house. | |||
| ENGIN1 | COMPLETE | 12/04/2020 | 12/04/2020 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 12/04/2020 | 12/04/2020 |
| Note: Released By: CPISCITELLI | |||
| PLUM | COMPLETE | 12/04/2020 | 12/09/2020 |
| Note: Released By: FREODICA Revision not applicable. | |||
| ZON | COMPLETE | 12/04/2020 | 12/07/2020 |
| Note: Released By: AMOBLEY | |||
| ELEC | COMPLETE | 09/17/2020 | 09/17/2020 |
| Note: Released By: JMUNSON | |||
| ZON | COMPLETE | 09/17/2020 | 09/18/2020 |
| Note: Released By: TDOAK | |||
| ZON | HOLD | 09/10/2020 | 09/11/2020 |
| Note: Held By: AMOBLEY No new elevation page submitted removing the wording for the decorative shutters | |||
| BLD | COMPLETE | 09/10/2020 | 09/16/2020 |
| Note: Released By: JPI | |||
| SW1 | COMPLETE | 09/10/2020 | 09/16/2020 |
| Note: Released By: CTROHA | |||
| ELEC | HOLD | 09/10/2020 | 09/11/2020 |
| Note: Held By: JMUNSON Electric load calcs have different contractor on them and wrong address | |||
| MECH | COMPLETE | 09/10/2020 | 09/10/2020 |
| Note: Released By: CPISCITELLI | |||
| ZON | HOLD | 09/01/2020 | 09/01/2020 |
| Note: Held By: AMOBLEY Please provide the walkway width and material on the site plan/survey Color sheet in pachage was blank. Please provide a completed color sheet. Please list the exterior material on the color sheet as siding and stucco and add a note that the stucco paint will match the siding. The floor plan shows two lanais and square footage for only one of them. Please correct. Shutters need to match the window height: LDRC Chapter 13: 13.03.03. D - D. Shutters.Shutters function as an accent to windows as well as weather protection. 1. Accent shutters.Accent shutters are designed as a visual detail for windows. a. Accent shutters shall be a contrasting color to the wall color. b. Shutters shall match the height of the window. c. Acceptable types of accent shutters include traditional horizontal slat or panel type shutters. Professional scoring or etching of a stucco wall to give the appearance of shutters is also acceptable. House does not meet the minimum front setback of 25ft Please give more detail on color sheet for the metal roof. It can not b | |||
| MECH | HOLD | 09/01/2020 | 09/01/2020 |
| Note: Held By: CPISCITELLI Previous hold comments are not correct. This is the correct hold 1. Orientation of Energy Calcs does not match the site plan. Revise to match the site plan. 2. Energy calcs need to be signed by the builder | |||
| SW1 | HOLD | 09/01/2020 | 09/01/2020 |
| Note: Held By: GBERTOLA FLOW ARROWS NOT PRESENT. NOT SOD ELEVATION.NOT FINISH FLOOR ELEVATION. NOT MINIMUM SLOPE FOR THE FIRST 10' | |||
| SWALE | COMPLETE | 09/01/2020 | 10/05/2020 |
| Note: Released By: TBAKER | |||
| SW1 | HOLD | 09/01/2020 | 09/01/2020 |
| Note: Held By: GBERTOLA FLOW ARROWS NOT PRESENT. NOT SOD ELEVATION. NOT FINISH FLOOR ELEVATION. NOT MIMIMUM SLOPE FOR THE FIRST 10' | |||
| UTL | COMPLETE | 08/31/2020 | 09/02/2020 |
| Note: Released By: LFITZGERALD | |||
| BLD | HOLD | 08/31/2020 | 09/07/2020 |
| Note: Held By: JPI 1) A2- FOOTER 4 IS NOT DIMENSIONED. ([A]107.2.1) 2) A2- MULTIPLE LINTELS ARE NOT TAGGED. ([A]107.2.1) 3) A3- WIND SPEED IS TOO SLOW, SEE ASCE7 -10 HAZARD TOOL FOR THIS LOCATION. ([A]107.2.1) 4) A4- ALL CONNECTOR TAGS ARE LABELED TYPICAL. CLARIFY WHICH ARE SPECIFIC AND WHICH ARE TYPICAL. ([A]107.2.1) | |||
| CUSVC | COMPLETE | 08/31/2020 | 09/02/2020 |
| Note: Released By: HHAND | |||
| ELEC | HOLD | 08/31/2020 | 09/01/2020 |
| Note: Held By: JMUNSON Submit electric load calcs. | |||
| ENGIN1 | COMPLETE | 08/31/2020 | 09/01/2020 |
| Note: Released By: TBAKER | |||
| LOCATE | COMPLETE | 08/31/2020 | 09/01/2020 |
| Note: Released By: CSTONE | |||
| MECH | HOLD | 08/31/2020 | 09/01/2020 |
| Note: Held By: CPISCITELLI 1. Orientation of Energy Calcs does not match the site plan. Revise to match the site plan. 2. Energy calcs say R0.9 on block walls. Plans show R9. Revise to match. 3. Energy calcs and EPL card need to be signed by the builder. | |||
| PLUM | COMPLETE | 08/31/2020 | 09/07/2020 |
| Note: Released By: JPI |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 12/06/2021 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/06/2021 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/06/2021 |
| REVISION | ¤40.00 | 12/06/2021 |
| SW ENG - FIELD SURVEY INSPECT | ¤20.00 | 12/06/2021 |
| REINSPECTION FEE | ¤40.00 | 12/06/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤396.00 | 09/20/2020 |
| STORM WATER PERMIT FEES | ¤80.00 | 09/20/2020 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 09/20/2020 |
| SEWER CREDIT | (¤1,147.00) | 09/20/2020 |
| SEWER INSPECTION | ¤25.00 | 09/20/2020 |
| SEWER CAPITAL FACILITY | ¤4,596.07 | 09/20/2020 |
| WATER CAPITAL FACILITY FEE | ¤3,374.18 | 09/20/2020 |
| SITE PLAN 20 | ¤20.00 | 09/20/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/20/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 09/20/2020 |
| CONNECTION FEES | ¤1,002.88 | 09/20/2020 |
| METER - DEPOSIT | ¤60.00 | 09/20/2020 |
| WATER- TURN ON | ¤25.00 | 09/20/2020 |
| ADMIN FEE | ¤20.00 | 09/20/2020 |
| BUILDING DISCOUNT 100% | (¤1,031.60) | 09/20/2020 |
| ELECTRIC FEE | ¤178.80 | 09/20/2020 |
| 3% FIRE IMPACT FEE CREDIT | (¤6.70) | 09/20/2020 |
| IMPACT FEE FIRE | ¤223.38 | 09/20/2020 |
| IMPACT FEE PARKS | ¤849.24 | 09/20/2020 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 09/20/2020 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 09/20/2020 |
| MECHANICAL FEE | ¤178.80 | 09/20/2020 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/20/2020 |
| 3% PARKS IMPACT FEE CREDIT | (¤25.48) | 09/20/2020 |
| PLAN CHECK FEE | ¤79.20 | 09/20/2020 |
| PLUMBING FEE | ¤178.80 | 09/20/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤14,541.85 |