Permit #2020090571
Permit Details
Status: FINAL
| Subdivision: 2157 - Palm Coast Park Tracts 18 & 20 |
| Job Phone: (386)446-6426 |
| Location Address: 101 MATANZAS WOODS PKWY |
| Type: CW - COMMERCIAL WALL |
| Issue Date: 10/13/2020 |
| NOC: RECORDED |
| Applicant name: SCOTT DALE SOWERS |
| Owner: PALM COAST REH LLC |
|
Address 577 BARNES BLVD, STE 650 ROCKLEDGE, FL 32955 |
| Contracted Stated Job Value: ¤20,175.00 |
| Job Description: STACK STONE SEGMENTAL RETAINING WALL |
| Type: CN |
Contractor
S E CLINE CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 354425 PALM COAST, FL 32137 |
CGC061947 (Exp: 08/31/2028) | (386)446-6426 | (386)446-6481 |
Inspection History
| Type | Request Date | Result | Inspector |
| LDSC- LANDSCAPE FINAL | 10/08/2021 | APPROVED - AS NOTED | DHANEY |
| Note: THIS IS A REINSPECTION Note: This is the front wall only. | |||
| FINAL | 04/22/2021 | FINAL APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 4-22-21... approved | |||
| LDSC- LANDSCAPE FINAL | 04/19/2021 | CANCELLED BY APPLICANT | JHARDING |
| FINAL | 04/19/2021 | Disapproved - NO FEE | FWILLIS |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL | |||
| RETAINING WALL | 10/21/2020 | APPROVED | JCOLASANTI |
| Note: PROGRESS INSPECTION. CONTACT MATT W/ ANY QUESTIONS 407-840-5044 | |||
| LINTEL | 10/21/2020 | APPROVED | JCOLASANTI |
| STEMWALL FOOTING | 10/20/2020 | APPROVED | JCOLASANTI |
| RETAINING WALL FOUNDATION | 10/20/2020 | APPROVED | JCOLASANTI |
| Note: THIS IS A REINSPECTION ADDED ON 10/19/2020 3:53:18 PM | |||
| RETAINING WALL FOUNDATION | 10/19/2020 | CANCELLED BY APPLICANT | BBEMBRY |
Review History
| Department | Status | Date In | Date Out |
| PLLA | COMPLETE | 10/02/2020 | 10/04/2020 |
| Note: Released By: BDAWSON | |||
| BLD | COMPLETE | 10/02/2020 | 10/13/2020 |
| Note: Released By: PBUCKLEY | |||
| PLENG | COMPLETE | 10/02/2020 | 10/05/2020 |
| Note: Released By: DLEAP | |||
| DSD | COMPLETE | 10/02/2020 | 10/05/2020 |
| Note: Released By: JGONZALEZ | |||
| BLD | HOLD | 09/14/2020 | 09/24/2020 |
| Note: Held By: PBUCKLEY All references below to the 2017 Florida Building Code-Building Provide Engineer’s digital seal on each plan sheet per Florida Statutes Chapter 471 and Florida Administrative Code Section 61G15-23.001 through 23.005. At resubmittal upload each plan sheet as a separate document. Uploading an entire plan-set as one document will result in plan rejection. Provide lateral soil design loads per Section 1610 and Table 1610.1. If a geotechnical investigation has been performed then provide copy of geotechnical investigation and design loads per Section 1803 and the geotechnical investigation. Provide indication design lateral pressure from surcharge loads has been added to the lateral earth pressure load per Section 1610. Provide indication whether retaining wall is designed for active or at-rest pressure per Section 1610. Provide indication retaining wall has been designed in accordance with Section 1807.2.3. Plans contain conflicting information regarding the proposed guard. Sheet S-1 provides design criteria but includes a section detail that contains a note that the railing is to be designed and constructed by others. Sheet S-1D indicates the guard is to be designed and constructed by Alumi-Guard, Inc. It appears a shop drawing signed and sealed by a Florida professional engineer is needed for the guard. Provide signed and sealed shop drawing or if to be provided at a later date, then place note on plans indicating a deferred submittal for this drawing is being requested per Section 107.3.4.1. | |||
| DSD | COMPLETE | 09/14/2020 | 09/16/2020 |
| Note: Released By: JGONZALEZ | |||
| PLENG | COMPLETE | 09/14/2020 | 09/17/2020 |
| Note: Released By: DLEAP | |||
| PLLA | HOLD | 09/14/2020 | 09/15/2020 |
| Note: Held By: BDAWSON - Label grade at top of wall and at bottom of wall. - Provide revised landscape plans that show adjusted height of plant material screening parking area to achieve 30" ht. min. from finish of parking lot. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| EXTENSION | ¤40.00 | 10/01/2021 |
| PLAN CHECK FEE | ¤100.00 | 10/13/2020 |
| SURCHARGE FS 533.721 | ¤2.00 | 10/13/2020 |
| SURCHARGE - FS 468.631 | ¤2.00 | 10/13/2020 |
| ADMIN COMMERCIAL | ¤60.00 | 10/13/2020 |
| INSPECTION - COMMERCIAL ACCESS | ¤141.23 | 10/13/2020 |
| BUILDING DISCOUNT 100% | (¤301.23) | 10/13/2020 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤44.00 |