I want to search for...
Permit #2020091271
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7002-00010-0190 |
| GARAGE: 400 sqft |
| CONDITIONED SPACE: 424 sqft |
| Total Square Footage: 824 sqft |
| Block: 00010 |
| Subdivision: 2218 - SECTION 2-FLORIDA PARK |
| Job Phone: 386-237-8637 |
| Location Address: 37 FARRADAY LN |
| Type: BA - BUILDING ADDITION |
| NOC: NO DOCUMENTATION |
| Applicant name: ERIC GLENN SAMUELSON |
| Owner: WILLIAMS BRIAN |
|
Address 37 FARRADAY LANE PALM COAST, FL 32137 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤64,000.00 |
| Job Description: GARAGE ADDITION |
| Type: CN |
Contractor
OUTBACK MARINE CONSTRUCTION
| Status | Location Address | State License Number | Phone |
| ACTIVE |
597 JOHN ANDERSON HWY FLAGLER BEACH, FL 32181 |
CBC1257381 (Exp: 08/31/2026) | 386-237-8637 |
Sub Contractors
CHARLES COURTNEY MCHONE JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
239 SR 16 ST. AUGUSTINE, FL 32095 |
CCC1330877 (Exp: 08/31/2026) | 904-669-8037 |
ROBERT CARLTON LITTLE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3050 EAST MOODY BLVD BUNNELL, FL 32110 |
EC13003740 (Exp: 08/31/2026) | 386-931-1708 |
Inspection History
| Type | Request Date | Result | Inspector |
| FOUND SURVEY APPROVED (OFFICE) | |||
| FINAL SURVEY (OFFICE USE ONLY) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | |||
| MONOLITHIC SLAB | |||
| ALL ROUGH | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | |||
| INSULATION | |||
| BLD - BUILDING FINAL | |||
| ROW - FINAL INSPECTION | |||
| U -UTILITY RESIDENTIAL FINAL |
Review History
| Department | Status | Date In | Date Out |
| MECH | HOLD | 11/24/2020 | 11/24/2020 |
| Note: Held By: CPISCITELLI Previous plans showed no habitable space. Provide energy calcs and heatload for existing garage converted to living space. | |||
| ZON | COMPLETE | 11/20/2020 | 11/23/2020 |
| Note: Released By: ELENS | |||
| BLD | COMPLETE | 11/20/2020 | 11/30/2020 |
| Note: Released By: PBUCKLEY | |||
| BADMIN | COMPLETE | 11/20/2020 | 11/23/2020 |
| Note: Released By: JMONTARULI | |||
| BADMIN | HOLD | 11/18/2020 | 11/18/2020 |
| Note: Held By: MDEFREITAS rename the plans just plans/remove the name from the front of the documents. | |||
| ZON | HOLD | 10/06/2020 | 10/06/2020 |
| Note: Held By: TDOAK As Per Land Development Code 4.01.03.B. Attached Garages: 1. Shall have a maximum depth of 30’. 2. Shall not exceed 50 percent of the total living area of the principal dwelling. The existing garage is legally non-conforming in that is exceeds the maximum depth that is allowed by this Land Development Code. Legal non-conformities cannot be made larger. Also, the living area of the home is 1249 square feet which would allow a garage that is a total of 624 square feet in order not the exceed the 50 percent maximum as noted in #2 above. There is an existing garage that totals 424 square feet and you are proposing to add another 400 square feet of garage. The existing garage (or portion of it) would need to be converted into living area in order for this garage addition to meet the regulations of the Land Development Code set forth above. | |||
| BLD | HOLD | 09/29/2020 | 10/06/2020 |
| Note: Held By: PBUCKLEY Provide lumber species for all framing members including rafters, joists, collar ties, beams, etec. You have provided grade (No. 2) but have not identified type of lumber species. Identify proposed room above garage. Note, this room must be identified as storage only as it does not confomr to any other residential habitable space category. Provide floor live and dead design loads. Provide roof live and dead design loads. Provide minimum width of stairway of not less than 36 inches. Provide height of guard. Indicate presence of handrail on stairs and provide handrail detail. Provide rim joist for ends of floor framing or provide solid blocking in between floor joists at ends. Provide opening dimension between guard ballusters. Provide opening dimension between triangle space formed by riser, tread and bottom element of guard. Provide handrail and detail. Provide stair to landing attachment details. Framing anchors / connectors required for positive connections. Provide minimum headroom clearance above stairs. Show exterior landing at garage door on site plan. Change reference to vapor barrier to water resistive barrier. Call out elevation of landing not to exceed 1.5 inches below top of garage door threshhold as door swings over landing. Glazed window near landing at bottom of stairs likely needs to be safety glazing / tempered glass if the bottom exposed edge is less than 36 inches above landing. | |||
| ELEC | COMPLETE | 09/29/2020 | 09/30/2020 |
| Note: Released By: JMUNSON | |||
| MECH | CANCEL | 09/29/2020 | 09/30/2020 |
| Note: not needed | |||
| SW1 | COMPLETE | 09/29/2020 | 09/30/2020 |
| Note: Released By: CTROHA | |||
| MECH | CANCEL |