Permit #2020100643

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7008-00150-0230
Total Square Footage: 0 sqft
Block: 00150
Subdivision: 1236 - LAKE FOREST
Job Phone: 386-447-0035
Location Address: 23 LAKE FOREST CT
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 01/04/2021
NOC: RECORDED
Applicant name: GARY W MCCAIN
Owner: CUNNINGHAM ROBERT SMITH II & EMMA RITA H&W & SANDR

Address

23 LAKE FOREST CT

PALM COAST, FL 32137

Address

CUNNINGHAM LOHREY JTWROS

PALM COAST, FL 32137

Lot: 0230
Contracted Stated Job Value: ¤5,000.00
Job Description: Remove & Replace Aluminum with Exterior Framed Stucco Wall with Windows & Doors
Type: CN

Contractor

MCCAIN CONSTRUCTION LLC
Status Location Address State License Number Phone
ACTIVE

15 WEIDNER PLACE

PALM COAST, FL 32164

CBC1261573 (Exp: 08/31/2026) 386-447-0035

Sub Contractors

MISHA ROMANOVSKIY
Status Location Address State License Number Phone Fax
INACTIVE

77 PEBBLE BEACH DRIVE

PALM COAST, FL 32164

ER13015548 (Exp: 08/31/2024) 386-793-5553 386-961-4388

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/05/2021 FINAL APPROVED WMILLER
Note: THIS IS A REINSPECTION not ready still workning also... needs arc shields for outlets NEC 314.20 02-05-21... deficiencies noted above resolved
BLD - BUILDING FINAL 02/03/2021 Disapproved - NO FEE WMILLER
Note: not ready still workning also... needs arc shields for outlets NEC 314.20
INSULATION 01/20/2021 APPROVED WMILLER
LATH/BRICK/ WATER BARRIER 01/20/2021 APPROVED WMILLER
ALL ROUGH 01/15/2021 APPROVED FWILLIS

Review History

Department Status Date In Date Out
BADMIN HOLD 01/14/2021 01/14/2021
Note: Held By: STHOMAS NOC IS NOT NOTARIZED
BADMIN COMPLETE 01/14/2021 01/14/2021
Note: Released By: MDEFREITAS
BLD COMPLETE 12/17/2020 12/23/2020
Note: Released By: FREODICA
MECH COMPLETE 11/23/2020 11/23/2020
Note: Released By: CPISCITELLI
BLD HOLD 11/23/2020 12/02/2020
Note: Held By: FREODICA Repeat comments 2, & 4: 2. Revise glazing calculation to comly with minimum requirement of 65% per difinition of Sunroom per FBC 6h Ed. Sec. Chapter 2. 4. Revise the Modified Floor Layout by deleting "covered screen" and re-name it appropriately clarity per FBC 6th Ed. Sec. 107.2.1. FReodica -386-986-4734 Note : Updated comments dated 12-2-20: Item 2: Submitted glazing calculation is incorrect. Glazing calculation is based on minimum 65% of total area of wall versus total area of glass below 6 ft 8 inches. Revised glazing calculation for sunroom shall be shown on plan: Total wall area below 6 ft 8 inches = 16' x 6.66' = 106.56 SF. Total glass area below 6 ft 8 inches = 20 + 20 + 12.5 + 20 = 72.5 SF. Minimum % glazing = 65% of total wall area/total glass area = 72.5/106.56 = 68 %. o.k. Item 4: Rename it as "Sunroom".
MECH HOLD 11/04/2020 11/05/2020
Note: Held By: CPISCITELLI 1. Show correct classification of sunroom on plans. Class 2 is non conditioned. The duct drawing shows conditioned. 2. Plans need to show removal of sliding glass door to the structure or provide return air in sunroom
ELEC COMPLETE 11/04/2020 11/04/2020
Note: Released By: JMUNSON
ZON COMPLETE 11/04/2020 11/05/2020
Note: Released By: ELENS
BLD HOLD 11/04/2020 11/12/2020
Note: Held By: FREODICA Held By: FREODICA Repeat comments 1,2, & 4: 1. Provide Sunroom Category of the proposed space conversion per FBCR 6th Ed. Sec. R301.2.1.1.1. 2. Revise glazing calculation to comly with minimum requirement of 65% per difinition of Sunroom per FBC 6h Ed. Sec. Chapter 2. 4. Revise the Modified Floor Layout by deleting "covered screen" and re-name it appropriately for clarity per FBC 6th Ed. Sec. 107.2.1. FReodica -386-986-4734 Note : Updated comments based on correction sumittal: Item 1. Sunroom category ll conficts with definition due to submittal of AC duct systen and for non-insulation of wall on typical detail. Item 2: Submitted glazing calculation is incorrect. Glazing calculation is based on min. 65% of total area of wall versus total area of glass below 6 ft 6 inches. The calculation shows 16 ft x 8 ft which appears to be floor area not total wall area.
BLD HOLD 10/14/2020 10/21/2020
Note: Held By: FREODICA 1. Provide Sunroom Category of the proposed space conversion per FBCR 6th Ed. Sec. R301.2.1.1.1. 2. Revise glazing calculation to comly with minimum requirement of 65% per difinition of Sunroom per FBC 6h Ed. Sec. Chapter 2. 3. Provide vertical dimensions of wall and windows on rear elevation to verify the required 65% glazing calculation as mentionin item 2. 4. Revise the Modified Floor Layout by deleting "covered screen" and re-name it appropriately for clarity per FBC 6th Ed. Sec. 107.2.1. FReodica -386-986-4734
ELEC HOLD 10/14/2020 10/15/2020
Note: Held By: JMUNSON Need to have outlets in the sunroom. NEC 2014 210.52 (A)
MECH HOLD 10/14/2020 10/15/2020
Note: Held By: CPISCITELLI Provide Energy Calcs
PLUM CANCEL 10/14/2020 10/21/2020
ZON HOLD 10/14/2020 10/15/2020
Note: Held By: TDOAK Provide site plan (if unavailable, use print out from property appraiser's office of the specific buiding) indicating the area where the proposed work is being done.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN FEE ¤20.00 01/04/2021
BUILDING DISCOUNT 100% (¤163.00) 01/04/2021
ELECTRIC FEE ¤63.00 01/04/2021
PLAN CHECK FEE ¤40.00 01/04/2021
REMODEL/ADDITION/ACCES INSPECT ¤40.00 01/04/2021
SITE PLAN 20 ¤20.00 01/04/2021
SURCHARGE FS 533.721 ¤2.00 01/04/2021
SURCHARGE - FS 468.631 ¤2.00 01/04/2021
Fees Total Due: ¤0.00 Total Paid: ¤24.00