Permit #2020110052
Permit Details
Status: COED
| Parcel Id: 16-11-30-4939-00000-0030 |
| Total Square Footage: 0 sqft |
| Block: 00000 |
| Subdivision: 2263 - PALM COAST INDUSTRIAL PARK PHASE III |
| Job Phone: 386-313-6950 |
| Location Address: 25 RAILSIDE WAY |
| Type: BC - BUILDING COMMERCIAL |
| Issue Date: 03/08/2021 |
| NOC: Unknown |
| Applicant name: MARK ANTHONY LANGELLO |
| Owner: V3 LLC |
|
Address 25 RAILSIDE WAY PALM COAST, FL 32137 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: BUILDING A - 3 UNIT WAREHOUSE |
| Type: CN |
Contractor
M & M DEVELOPMENT & CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| CANCEL |
2323 N. STATE ST BUNNELL, FL 32110 |
RG291103911 (Exp: 08/31/2023) | 386-313-6950 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3000 E MOODY BLVD BLDG 2 BUNNELL , FL 32110 |
EC13004270 (Exp: 08/31/2026) | 386-931-6614 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
Inspection History
| Type | Request Date | Result | Inspector |
| U - UTILITY COMMERCIAL FINAL | 10/26/2021 | FINAL APPROVED | DHANEY |
| Note: THIS IS A REINSPECTION | |||
| FIRE FINAL | 10/05/2021 | APPROVED | LMILLER |
| Note: New inspection due to canceled inspection New inspection due to canceled inspection THIS IS A REINSPECTION not ready need to complete Fire alarm and Sprinkler permits prior. also need ceiling tiles need to be installed correctly with no gaps, and seal hole in wall at sprinkler inder stairs 10-5-21... notes above resolved | |||
| BUILDING FINAL | 10/05/2021 | CANCELLED BY APPLICANT | WEB |
| Note: New inspection due to canceled inspection THIS IS A REINSPECTION need tactile signage for ADA per FBC 703 | |||
| BUILDING FINAL | 10/05/2021 | FINAL APPROVED | LMILLER |
| Note: New inspection due to canceled inspection New inspection due to canceled inspection THIS IS A REINSPECTION need tactile signage for ADA per FBC 703 10-5-21... notes above resolved | |||
| BUILDING FINAL | 10/04/2021 | CANCELLED BY APPLICANT | WEB |
| Note: THIS IS A REINSPECTION need tactile signage for ADA per FBC 703 | |||
| FIRE FINAL | 10/04/2021 | CANCELLED BY APPLICANT | WEB |
| Note: New inspection due to canceled inspection THIS IS A REINSPECTION not ready need to complete Fire alarm and Sprinkler permits prior. also need ceiling tiles need to be installed correctly with no gaps, and seal hole in wall at sprinkler inder stairs | |||
| FIRE FINAL | 10/01/2021 | CANCELLED BY APPLICANT | WEB |
| Note: THIS IS A REINSPECTION not ready need to complete Fire alarm and Sprinkler permits prior. also need ceiling tiles need to be installed correctly with no gaps, and seal hole in wall at sprinkler inder stairs | |||
| U - UTILITY COMMERCIAL FINAL | 09/27/2021 | CANCELLED BY APPLICANT | DHANEY |
| BUILDING FINAL | 09/27/2021 | Disapproved - NO FEE | LMILLER |
| Note: need tactile signage for ADA per FBC 703 | |||
| FIRE FINAL | 09/27/2021 | Disapproved - NO FEE | LMILLER |
| Note: not ready need to complete Fire alarm and Sprinkler permits prior. also need ceiling tiles need to be installed correctly with no gaps, and seal hole in wall at sprinkler inder stairs | |||
| PLUMBING FINAL | 09/24/2021 | APPROVED | PBUCKLEY |
| HVAC FINAL | 09/24/2021 | APPROVED | PBUCKLEY |
| ELECTRIC FINAL | 09/24/2021 | APPROVED | RMARTIN |
| ELECTRIC - EARLY POWER | 09/17/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 11:10 | |||
| ELECTRIC - EARLY POWER | 09/16/2021 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC - EARLY POWER | 09/16/2021 | Disapproved - NO FEE | RMARTIN |
| Note: APPROVED PLAN DOES NOT MATCH WHAT IS INSTALLED, NEED REVISION SHOWING CHANGES | |||
| EXTERIOR ARCHITECTURAL FEATURES | 09/16/2021 | APPROVED | JHARDING |
| GRAVITY SEWER | 07/23/2021 | APPROVED | JGIBSON |
| BLD - SEWER TIE IN | 07/23/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: NO U-SEWER TIE IN ON BUILDING PERMIT, BUT WAS ON CSD PERMIT USEWR CONNECTION APPROVED AS WELL | |||
| DOWN CELL | 06/21/2021 | APPROVED | FWILLIS |
| ABOVE CEILING | 06/21/2021 | APPROVED - AS NOTED | RMARTIN |
| Note: NO PLUMBING, WILL LOOK AT THE ELECTRIC AND HVAC AT LATER INSPECTION | |||
| INSULATION | 05/17/2021 | CANCELLED BY APPLICANT | WEB |
| INSULATION | 05/17/2021 | APPROVED | FWILLIS |
| FRAMING | 05/17/2021 | CANCELLED BY APPLICANT | WEB |
| FRAMING | 05/17/2021 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACE / TIE DOWN | 05/17/2021 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACE / TIE DOWN | 05/17/2021 | APPROVED | FWILLIS |
| PLUMBING 2ND ROUGH | 05/17/2021 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 2ND ROUGH | 05/17/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: NEED STRAPS ON WATER LINES FROMMOP BASIN ACROSS WHERE ROLL UP GARAGE DOOR IS AT, NAIL PLATES ON FRAME WALL AT WATER HEATER | |||
| ELECTRIC 2ND ROUGH | 05/17/2021 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC 2ND ROUGH | 05/17/2021 | APPROVED | JMUNSON |
| HVAC ROUGH | 05/17/2021 | CANCELLED BY APPLICANT | WEB |
| HVAC ROUGH | 05/17/2021 | APPROVED | CPISCITELLI |
| FOUNDATION SURVEY - OFFICE USE ONLY | 05/14/2021 | APPROVED | DLEAP |
| INSULATION | 05/11/2021 | CANCELLED BY APPLICANT | WEB |
| STOREFRONT | 05/05/2021 | APPROVED | FWILLIS |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 09/16/2021 | 09/17/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/13/2021 | 05/14/2021 |
| Note: Released By: DENNIS R. LEAP, P.E. - - DLEAP@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 05/13/2021 | 05/14/2021 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Per dennis leep okay to release. | |||
| DSD | CANCEL | 05/10/2021 | 05/13/2021 |
| ENGIN1 | HOLD | 05/10/2021 | 05/11/2021 |
| Note: Held By: DENNIS LEAP - - DLEAP@PALMCOASTGOV.COM 1. Plan to be labeled as Foundation Survey. 2. Plan to be signed and sealed. | |||
| ELEC | COMPLETE | 03/03/2021 | 03/04/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 03/03/2021 | 03/05/2021 |
| Note: Released By: WILLIAM MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 03/03/2021 | 03/05/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/03/2021 | 03/05/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/03/2021 | 03/04/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 01/29/2021 | 02/01/2021 |
| Note: Held By: JMUNSON Electric load calcs are not done for a commercial building. NEC 2014 220.12, 220.14 | |||
| MECH | COMPLETE | 01/29/2021 | 02/01/2021 |
| Note: Released By: CPISCITELLI | |||
| FI1 | HOLD | 01/29/2021 | 02/04/2021 |
| Note: Held By: WMILLER Still need the following... 1. Classification of contents 6.2.1.2 Hazard of contents needs to be classified by the registered design professional (RDP) and submitted for review and approval on the basis of the character of the contents in the building or structure. 2. Please show travel distance from the most remote location to the exits (including above office area). | |||
| BLD | HOLD | 01/29/2021 | 02/16/2021 |
| Note: Held By: PBUCKLEY 1. Upload Plan Sheets F1, F2, and F3 provided by the steel building manufacturer. Ensure plans are signed and sealed by the P.E. of record. Previous plan sheets were not signed and sealed and also had a boxed checked that they were for the steel erector only. Either uncheck all boxes or check the box for Construction Permit Set. 2. Repeating Comment from 1st review. Structural foundation Plan Sheet S1 does not indicate the presence of any interior footings to support mezzanine floor construction of 50 p.s.f. Foundation engineer of record to verfify in writing by letter that the slab is capable of supporting live and dead loads from walls supporting mezzanine based on the imposed loads. 3. Add floor trusses to deferred submittal list. A set of floor truss plans signed and sealed by a Florida P.E. are requried to be submitted when plans are ready - same as would be done for roof truss plans. Be sure the floor truss plans include proper live and dead loads. | |||
| PLUM | HOLD | 01/29/2021 | 02/16/2021 |
| Note: Held By: PBUCKLEY All references below to the 2017 Florida Building Code-Plumbing The job description provided by the Plumbing Contractor does not satisfy the plan review comments from the intial review. Additionally, the mezzanine now depics a bathroom and the plumbing riser diagram on Plan Sheet A4 does not show any DWV piping to the second flloor. 1. Based on the estimated number of plumbing facilities the building drain shall be 4 inch minimum if serving all four tenant spaces. If individual building drains / building sewers are proposed independent to each tenant space please indicate as much and show locations, materials, size, etc. NEW COMMENT: THE RISER DIAGRAM IS UNCLEAR WHETHER BUILDING SEWERS WILL EXTEND TO THE SEWER MAIN AS INDEPENDENT LINES OR IF THEY WILL BE COMBINED. IF COMBINED, THE BUILDING SEWER WILL NEED TO BE 4 INCH TO THE MAIN. IF INDEPENDENT TO THE MAIN, THEN 3 INCH WILL SUFFICE. CLARIFY THE INTENT IN THE RISER DIAGRAM. 2. Provide location, materials specifications and size of building sewer(s) and water service(s). 3. Provide complete water piping and drain, waste and vent material schedule. 4. Provide location and specifications for water heater in proposed tenant space. | |||
| UD1 | COMPLETE | 01/14/2021 | 01/21/2021 |
| Note: Released By: CJOHNSON | |||
| ELEC | HOLD | 01/14/2021 | 01/27/2021 |
| Note: Held By: JMUNSON 1. Submit electrical load calculations. 2.Panel schedule needs to match the riser diagram 3. Need to comply with 2017 FBC Energy code completion requirements 408.3.1 | |||
| MECH | HOLD | 01/14/2021 | 01/27/2021 |
| Note: Held By: CPISCITELLI 1. Provide Manual N heatload Calculation per C403.2.1 FBC Energy Conservation 2017 6Th Edition. Provide correct form. (Second Request) 2. Duct layout needs to show Return Air in Office 2 per 601.6 FBC Mechanical 2017 6Th Edition (Second Request) 3. Provide details of volume dampers on duct layout per 603.18 FBC Mechanical 2017 6Th Edition (Second Request) 4. Provide Manufacturers specs on fire dampres showing model and UL rating | |||
| FI1 | HOLD | 01/14/2021 | 01/27/2021 |
| Note: Held By: WMILLER Still need the following... 1. Classification of contents 6.2.1.2 Hazard of contents needs to be classified by the registered design professional (RDP) and submitted for review and approval on the basis of the character of the contents in the building or structure. 2. Please explain the call out for Type-K extinguisher in the legend on the life safety plan. 3. Please show travel distance from the most remote location to the exits (including above office area). NOTE: please place a note stating that separate permits will be required for fire sprinklers and alarms. | |||
| PLUM | HOLD | 01/14/2021 | 01/28/2021 |
| Note: Held By: PBUCKLEY SEE BUILDING REVIEW HOLD. PLANS APPEAR NOT TO HAVE BEEN REVISED TO ADDRESS THE INITIAL REVIEW COMMENTS. ALL COMMENTS BELOW ARE REPEATING FROM THE INITIAL REVIEW. All references below to the 2017 Florida Building Code-Plumbing 1. Replace plumbing riser note with note applicable to this building. 2. Based on the estimated number of plumbing facilities the building drain shall be 4 inch minimum if serving all four tenant spaces. If individual building drains / building sewers are proposed independent to each tenant space please indicate as much and show locations, materials, size, etc. 3. Provide complete plumbing equipment schedule. 4. Provide location, materials specifications and size of building sewer(s) and water service(s). 5. Provide complete water piping and drain, waste and vent material schedule. 6. Provide plumbing hanger and support schedule. 7. Remove note indicating duct layout and other partial illegible note. 8. Provide location and specifications for water heater in proposed tenant space. | |||
| BLD | HOLD | 01/14/2021 | 01/28/2021 |
| Note: . 4. Provide foundation note indicating foundation is designed in accordance with the geotechnical investigation prepared for this property. Include name of geotechnical engineer, report number and date of report per Chapter 18. 6. Architectural floor plan indicates load bearing walls supporting a second floor. Foundation plan does not indicate the presence of footings under bearing walls. Un-reinforced concrete slabs are allowed to carry 750 p.s.f. loads. Please have foundation engineer check to ensure load bearing walls can be adequately supported by un-reinforced concrete slab per Chapter 19. | |||
| ARCHR | COMPLETE | 11/02/2020 | 11/15/2020 |
| Note: Released By: BDAWSON | |||
| BLD | HOLD | 11/02/2020 | 11/17/2020 |
| Note: Held By: PBUCKLEY All references below to the 2017 Florida Building Code-Building 1. Life Safety Plan uploaded as Electrical Load Calculations. On resubmittal, upload life safety plan with appropriate name. 2. Provide product approval number for all windows, garage roll-up doors and exterior store-front doors. 3. Revise note at typical non-bearing wall interior wall section. Remove reference to the Florida Residential Code. Note is also partially cut-off. Provide complete notes. Provide grade and species of wood studs. Provide fire blocking detail as wall likely exceeds 10 feet in height between top and bottom plates. 4. Provide detail related to UL File 419 for extending and maintaining fire-resistive construction for each intersecting wall where they connect to exterior fire-rated walls per Chapter 7. 5. Provide rim-joist detail for all wood floor trusses / joists per Section 2308.4.2.3. 6. Provide foundation note indicating foundation is designed in accordance with the geotechnical investigation prepared for this property. Include name of geotechnical engineer, report number and date of report per Chapter 18. 7. Revise soil bearing pressure in Foundation Note No., 8 to reflect soil bearing pressure of 2,500 p.s.f. geotechnical investigation. 8. Architectural floor plan indicates load bearing walls supporting a second floor. Foundation plan does not indicate the presence of footings under bearing walls. Un-reinforced concrete slabs are allowed to carry 750 p.s.f. loads. Please have foundation engineer check to ensure load bearing walls can be adequately supported by un-reinforced concrete slab per Chapter 19. 9. Architectural floor plan indicates stairs leading to a second floor, mezzanine or loft. Provide floor plan for this space. Indicate proposed use of space. Provide other details such as wall construction, ceiling height, location of windows, floor design load based on use of space etc. 10. Foundation Note No. 1 shall also reference ACI 318-14 in addition to the 2017 FBC. 11. Provide plan sheets properly signed and sealed by the architect of record per FS 471.025 and Florida Administrative Code 61G15-23.003. Date shall be provided at each seal per the referenced sections. 12. Provide complete steel building plans signed and sealed by a Florida licensed professional engineer. Steel building plans to include all project design criteria including but not limited to; floor live and dead loads per Section 1603.1.1, roof live and dead loads per Section 1603.1.3 and 1607.12, wind design data per Section 1603.1.4 No’s 1 through 5 and 1609. Designate exposure category per 1609.4. Indicate whether impact resistant coverings are required per Section 1609.1.2.4. Indicate all pressure coefficients per Section 1609.6.4.3 and Table 1609.6.2. 13. Design professional in responsible charge to provide a complete list of deferred submittals by written note(s) on plans. This includes but is not necessarily limited to; any pre-manufactured / factory constructed stairs, guards, equipment platforms, bar joists, fire sprinkler systems (note for fire sprinkler system to include statement that separate permit is required) etc. Provide note indicating any deferred submittals shall be submitted to the Palm Coast Building Department for review and approval prior to installation per Section 107.3.4.1. 14. Provide complete code analysis for proposed building including but not necessarily limited to: proposed occupancy or occupancies per Section 302 through 312. Note: the limited code analysis provided indicates an occupancy category of “S” but the analysis is incomplete. Is the proposed occupancy S-I or S-II? Proposed finished tenant space indicates presence of office, and reception area and second floor or mezzanine making this space a mixed occupancy building including S (I or II) and B (business office) occupancies. All of building will likely be mixed occupancy – B and S (I or II). Please provide analysis answering items below for entire building or each time a tenant space is to be finished an analysis will be required then. Analysis to include: • Allowable floor area versus actual floor area per Section 506 • Area increases, if required, based on occupancy and construction type per Section 506. Include open space and / or fire sprinkler system allowable area and height increases as applicable. • Allowable building height versus actual building height per Section 504 and Section 504.2 if mixed occupancy building • Allowable number of stories versus actual number of stories per Section 504 • Height or number of story increases if required based on occupancy and construction type per Section • Mezzanine / 2nd floor (Tenant Space 1 indicates presence of a mezzanine or second floor) area calculations per Section 505 • Indicate whether separated or unseparated uses occupancies per Section 508. If uses are to be separated then provide separation details per Section 508 and Table 508.4. • Indicate any incidental uses and requirements per Section 509 and Table 509. • Assign building risk category per Section 1604.5 and table 1604.5 or ASCE 7. 15. Provide complete UL File Number for fire resistive rated walls per Section 107.3.5 No. 4. 16. Provide all project design criteria including but not limited to; Floor live and dead loads for each floor per Section 1603.1.1, roof live loads per Section 1603.1.3 and 1607.12, wind design data per Section 1603.1.4 No’s 1 through 5 and 1609. Designate exposure category per 1609.4. Indicate whether impact resistant coverings are required per Section 1609.1.2.4. Indicate all pressure coefficients per Section 1609.6.4.3 and Table 1609.6.2, Indicate load combinations per Section 1604.2 and 1605, dead loads per 1606 and live loads per 1607. Provide other uniformly distributed and concentrated live loads for items such as stairs, stair treads, guards and similar items not mentioned herein per Section 1607 and Table 1607.1. 17. Stair section depicts a guard but floor plan indicates a half-wall with cap. Which is it? 18. Indicate glazing required to be tempered glass in door and window schedule per Section 2406. 19. Provide stair landing dimensions for stair mid-point landing. Stair section appears to conflict with plan view per Section 1014. 20. Provide complete stair section including headroom height. Provide stair handrail detail indicating handrail returns and handrail safety extensions beyond first and last riser of stairs. Show handrail continuous through intermediate landing per Sections 1011, 1014 and 1015. All references below to the 2017 Florida Building Code-Accessibility 1. Provide width of hall and passages per Section 402 and 403.5. 2. Check approach requirements for Door 104. If the hall is less than 48 inches in width, door approach will be considered parallel to latch and hinge side and a 60 inch maneuvering space is required in front of door per Section 404 and Table 404.2.4.1. 3. Provide dimensions of landings at exterior doors including width, length in the direction of travel, maximum allowable running and cross slopes and maneuvering clearances at doors. Door No. 105 does not appear to meet minimum maneuvering clearance on push side of latch. Section 404.2 and Table 404.2.4.1 4. Provide accessible sign detail and location for bathroom per Section 703. 5. Revise door schedule to indicate doors that require kick plates per Section 404.2.10. 6. Identify knee and toe clearances at ADA sink counter section for both the bath lavatory and office sink. 7. Provide mounting location for toilet paper dispenser in relation to water closet per Section 604.7. 8. Provide grab bar blocking and mounting / attachment detail and note indicating blocking and attachments support minimum 250 p.s.f. load per Section 609.8. | |||
| DSD | COMPLETE | 11/02/2020 | 11/06/2020 |
| Note: Released By: DRAMIREZ | |||
| ELEC | HOLD | 11/02/2020 | 11/10/2020 |
| Note: Held By: JMUNSON 1. Submit electrical load calculations. 2.Panel schedule needs to match the riser diagram 3. Need to comply with 2017 FBC Energy code completion requirements, 405.6.4.1, 405.6.4.2 and 408.3.1 4. Submit interior lighting compliance certificate. FBC Energy code 2017 | |||
| FI1 | HOLD | 11/02/2020 | 11/16/2020 |
| Note: Held By: WMILLER 1. Classification of contents 6.2.1.2 Hazard of contents needs to be classified by the registered design professional (RDP) and submitted for review and approval on the basis of the character of the contents in the building or structure. 2. Please explain the call out for Type-K extinguisher in the legend on on the life safety plan. 3. PLease shoe travel distance from the most remote location to the exits (encluding above office area). NOTE: please be advised the separate permits will be required for fire sprinklers and alarms. | |||
| MECH | HOLD | 11/02/2020 | 11/10/2020 |
| Note: Held By: CPISCITELLI 1. Provide Energy Calculations per Section C407 FBC Energy Conservation 2017 6Th Edition. 2. Provide Manual N heatload Calculation per C403.2.1 FBC Energy Conservation 2017 6Th Edition 3. Duct layout needs to show Return Air in Office 2 per 601.6 FBC Mechanical 2017 6Th Edition 4. Provide details of volume dampers on duct layout per 603.18 FBC Mechanical 2017 6Th Edition | |||
| PLUM | HOLD | 11/02/2020 | 11/17/2020 |
| Note: Held By: PBUCKLEY All references below to the 2017 Florida Building Code-Plumbing 1. Replace plumbing riser note with note applicable to this building. 2. Based on the estimated number of plumbing facilities the building drain shall be 4 inch minimum if serving all four tenant spaces. If individual building drains / building sewers are proposed independent to each tenant space please indicate as much and show locations, materials, size, etc. 3. Provide complete plumbing equipment schedule. 4. Provide location, materials specifications and size of building sewer(s) and water service(s). 5. Provide complete water piping and drain, waste and vent material schedule. 6. Provide plumbing hanger and support schedule. 7. Remove note indicating duct layout and other partial illegible note. 8. Provide location and specifications for water heater in proposed tenant space. | |||
| UD1 | HOLD | 11/02/2020 | 11/06/2020 |
| Note: Held By: CJOHNSON Provide water service layout and riser. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | 03/08/2021 |
| BUILDING DISCOUNT 100% | (¤3,197.50) | 03/08/2021 |
| ELECTRIC FEE | ¤270.00 | 03/08/2021 |
| IMPACT FEE FIRE | ¤8,850.00 | 03/08/2021 |
| IMPACT FEE TRANSPORTATION | ¤25,920.00 | 03/08/2021 |
| MECHANICAL FEE | ¤270.00 | 03/08/2021 |
| PERMIT FEE | ¤1,925.00 | 03/08/2021 |
| PLAN CHECK FEE | ¤402.50 | 03/08/2021 |
| PLUMBING FEE | ¤270.00 | 03/08/2021 |
| SITE PLAN 20 | ¤20.00 | 03/08/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/08/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/08/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤34,794.00 |