I want to search for...
Permit #2020110408
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7016-00120-0420 |
| CONDITIONED SPACE: 2016 sqft |
| GARAGE: 451 sqft |
| OPENED PORCH (WITH ROOF) : 250 sqft |
| OPENED PORCH (WITH ROOF) : 116 sqft |
| Total Square Footage: 2833 sqft |
| Block: 00120 |
| Subdivision: 2201 - SECTION 16-COUNTRY CLUB COVE |
| Job Phone: 386-447-7007 |
| Location Address: 6 CLEMENT CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 01/12/2021 |
| NOC: RECORDED |
| Applicant name: MAXIM TARANNIK |
| Owner: AGAT LLC |
|
Address 6 FLAMINGO DR PALM COAST, FL 32137 |
| Lot: 0420 |
| Contracted Stated Job Value: ¤284,000.00 |
| Job Description: Single Home Residence |
| Type: CN |
Contractor
GOLDEN MAGNOLIA, INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1 ROCKEFELLER DRIVE PALM COAST, FL 32164 |
RR282811984 (Exp: 08/31/2025) | 386-447-7007 |
Sub Contractors
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| CANCEL |
457 CHELSEA PLACE AV ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2022) | 570-575-8139 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 06/07/2022 | APPROVED - AS NOTED | EMADISON |
| Note: ** MET BUILDER ON SITE AS HE WAS FINISHING UP SEDIMENT REMOVAL FROM CANAL. TOLERANCES HAVE BEEN MET 4' FROM TOP OF SEA WALL TO BOTTOM. RIGHT SIDE FILLED IN RUTS CAUSED BY EROSION ON SLOP, WILL BE SODDED SETTING UP A TEMPORARY SILT FENCING ON SLOPE UNTIL NEW SOD AND GRASS TAKES ROOT. * NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION SEDIMENT HAS NOT BEEN REMOVED * RIGHT SIDE PROPERT DEVELOPING A LARGE WASHOUT CINTINUING TO WASH SEDIMENT INTO THE CANAL THIS NEEDS BE ADDRESSED SO AS TO NOT HAVE A NEGATIVE IMPACT ON THE CANAL. NOTE TO INSPECTOR: Remove the large pile of sediment that washed into the canal on BOTH rear property lines. Match the surrounding bottom grade. | |||
| ROW - FINAL APRON (AFTER POUR) | 06/06/2022 | APPROVED - AS NOTED | EMADISON |
| Note: ** CORRECTIONS MADE Clean Culvert Ends | |||
| BLD - BUILDING FINAL | 06/06/2022 | FINAL APPROVED | MKRASKI |
| Note: | |||
| ROW - STORMWATER FINAL | 06/03/2022 | Disapproved -FEE REQUIRED | EMADISON |
| Note: * NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION SEDIMENT HAS NOT BEEN REMOVED * RIGHT SIDE PROPERT DEVELOPING A LARGE WASHOUT CINTINUING TO WASH SEDIMENT INTO THE CANAL THIS NEEDS BE ADDRESSED SO AS TO NOT HAVE A NEGATIVE IMPACT ON THE CANAL. NOTE TO INSPECTOR: Remove the large pile of sediment that washed into the canal on BOTH rear property lines. Match the surrounding bottom grade. | |||
| BLD - BUILDING FINAL | 05/31/2022 | Disapproved - NO FEE | LMILLER |
| Note: THIS IS A REINSPECTION 1. Hallway outlet loose ( left of entry). 2. Front right bedroom outlet loose ( right wall). 3. Laundry walll outlet loose. 4. Master bedroom outlets loose. 5. Master bathroom shower water does not work. 6. Master bed room smoke covered. 7. No insulation. 8. Energy calcs do not match either units. 9. Garage door ceiling wire not sealed. 5-31-22 Garage door ceiling wire still not sealed. | |||
| ROW - DRAINAGE | 05/09/2022 | APPROVED - AS NOTED | RGROSS |
| Note: Inspect the silt in the canal and take appropriate action THIS IS A REINSPECTION There is alot of sediment in the saltwater canal that needs to be removed. Personaly I would remove this before building the slab. 5/9/22 - This drainage issue is being addressed on the Final Stormwater Inspection. | |||
| ROW - STORMWATER FINAL | 05/06/2022 | Disapproved -FEE REQUIRED | RGROSS |
| Note: Remove the large pile of sediment that washed into the canal on BOTH rear property lines. Match the surrounding bottom grade. | |||
| U -UTILITY RESIDENTIAL FINAL | 05/06/2022 | FINAL APPROVED | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 05/06/2022 | Disapproved - NO FEE | RGROSS |
| Note: Clean Culvert Ends | |||
| BLD - BUILDING FINAL | 05/06/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1. Hallway outlet loose ( left of entry). 2. Front right bedroom outlet loose ( right wall). 3. Laundry walll outlet loose. 4. Master bedroom outlets loose. 5. Master bathroom shower water does not work. 6. Master bed room smoke covered. 7. No insulation. 8. Energy calcs do not match either units. 9. Garage door ceiling wire not sealed. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 05/05/2022 | APPROVED | RGROSS |
| Note: THIS IS A REINSPECTION This inspection is for a "Final" survey not a "Foundation" survey. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/05/2022 | APPROVED | RGROSS |
| FINAL SURVEY (OFFICE USE ONLY) | 05/04/2022 | Disapproved - NO FEE | RGROSS |
| Note: This inspection is for a "Final" survey not a "Boundery" survey. | |||
| U-CROSS CONNECTION | 04/19/2022 | APPROVED | DHANEY |
| ROW- PRE-APRON (PRE-POUR) | 03/03/2022 | APPROVED | RGROSS |
| Note: READY TO POUR | |||
| GRAVITY SEWER TEST | 01/26/2022 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 01/26/2022 | APPROVED | MGIBSON |
| ELECTRIC - EARLY POWER | 11/29/2021 | APPROVED - AS NOTED | JMUNSON |
| Note: THIS IS A REINSPECTION House needs to be unlocked 11/29/21 Emailed FPL at 10:55 am | |||
| ELECTRIC - EARLY POWER | 11/24/2021 | Disapproved - NO FEE | JMUNSON |
| Note: House needs to be unlocked | |||
| U - SEWER TIE IN | 11/22/2021 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 11/02/2021 | APPROVED | LMILLER |
| INSULATION | 10/11/2021 | APPROVED | FWILLIS |
| Note: Need the following by insulation.... Slider door | |||
| ALL ROUGH | 10/05/2021 | APPROVED - AS NOTED | LMILLER |
| Note: THIS IS A REINSPECTION New inspection due to canceled inspection THIS IS A REINSPECTION cancelled per MIke 9-29-21... 1. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 2. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER 3. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 4. NEED TO SEAL DRYER DUCT AT ROOF WITH MASTIC..FBC.. M1502.4.2 AND M1601.4.1… Need the following by insulation.... Slider door 10-5-21... 1. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) Need the following by insulation.... Slider door | |||
| ALL ROUGH | 09/29/2021 | Disapproved -FEE REQUIRED | LMILLER |
| Note: New inspection due to canceled inspection THIS IS A REINSPECTION cancelled per MIke 9-29-21... 1. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 2. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER 3. 5ft HEAD OF WATER, FBC CHAPTER 25 SECTION P2503.5.1 (1) 4. NEED TO SEAL DRYER DUCT AT ROOF WITH MASTIC..FBC.. M1502.4.2 AND M1601.4.1… Need the following by insulation.... Slider door | |||
| ALL ROUGH | 09/28/2021 | CANCELLED BY APPLICANT | WEB |
| Note: THIS IS A REINSPECTION cancelled per MIke | |||
| ALL ROUGH | 09/22/2021 | CANCELLED BY APPLICANT | LMILLER |
| Note: cancelled per MIke | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/07/2021 | APPROVED | JPI |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION New inspection due to canceled inspection THIS IS A REINSPECTION 1. TRUSS BLOCKING REQUIRED WHERE SHEATHING SPANS MORE THAN 24 inches. (PER MANUFACTURER SPECS ON ENGINEERED SHEATHING) (OR SUPPLY MANUFACTURER SPECS FOR APPLICATION USED) 2. need revision for engineers repair of altered trusses (highlighted an plans) 3. missing strapps (highlighted an plans) 902021... still need revision for engineers repair of altered trusses (highlighted an plans) 9-3-21... still need revision (revision musrt be approved | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/03/2021 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION New inspection due to canceled inspection THIS IS A REINSPECTION 1. TRUSS BLOCKING REQUIRED WHERE SHEATHING SPANS MORE THAN 24 inches. (PER MANUFACTURER SPECS ON ENGINEERED SHEATHING) (OR SUPPLY MANUFACTURER SPECS FOR APPLICATION USED) 2. need revision for engineers repair of altered trusses (highlighted an plans) 3. missing strapps (highlighted an plans) 902021... still need revision for engineers repair of altered trusses (highlighted an plans) 9-3-21... still need revision (revision musrt be approved | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/02/2021 | Disapproved - NO FEE | WMILLER |
| Note: New inspection due to canceled inspection THIS IS A REINSPECTION 1. TRUSS BLOCKING REQUIRED WHERE SHEATHING SPANS MORE THAN 24 inches. (PER MANUFACTURER SPECS ON ENGINEERED SHEATHING) (OR SUPPLY MANUFACTURER SPECS FOR APPLICATION USED) 2. need revision for engineers repair of altered trusses (highlighted an plans) 3. missing strapps (highlighted an plans) 902021... still need revision for engineers repair of altered trusses (highlighted an plans) | |||
| ROOF VALLEY & METAL | 08/30/2021 | APPROVED | WMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/30/2021 | CANCELLED BY APPLICANT | WEB |
| Note: THIS IS A REINSPECTION 1. TRUSS BLOCKING REQUIRED WHERE SHEATHING SPANS MORE THAN 24 inches. (PER MANUFACTURER SPECS ON ENGINEERED SHEATHING) (OR SUPPLY MANUFACTURER SPECS FOR APPLICATION USED) 2. need revision for engineers repair of altered trusses (highlighted an plans) 3. missing strapps (highlighted an plans) | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/20/2021 | Disapproved -FEE REQUIRED | WMILLER |
| Note: 1. TRUSS BLOCKING REQUIRED WHERE SHEATHING SPANS MORE THAN 24 inches. (PER MANUFACTURER SPECS ON ENGINEERED SHEATHING) (OR SUPPLY MANUFACTURER SPECS FOR APPLICATION USED) 2. need revision for engineers repair of altered trusses (highlighted an plans) 3. missing strapps (highlighted an plans) | |||
| ELEV CERT-FOUNDATION APPROVAL | 08/18/2021 | APPROVED | JMYERS |
| TIE BEAM / LINTEL | 07/27/2021 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION Approved Documents need to be on site for inspection 107.3,1. 7-27-21... Notes above resolved | |||
| TIE BEAM / LINTEL | 07/26/2021 | Disapproved -FEE REQUIRED | WMILLER |
| Note: NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION Approved Documents need to be on site for inspection 107.3,1. | |||
| FOUND SURVEY APPROVED (OFFICE) | 07/08/2021 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 06/10/2021 | APPROVED | BGREVE |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/08/2021 | APPROVED | JGIBSON |
| RETAINING WALL FOUNDATION | 05/06/2021 | APPROVED | BGREVE |
| FOOTER | 04/14/2021 | Disapproved -FEE REQUIRED | BGREVE |
| Note: no approved drawings onsite no drawing for retaining wall footing onsite | |||
| FOOTER | 04/14/2021 | APPROVED | BGREVE |
| Note: contractor brought plans to the site and i returned to complete inspection THIS IS A REINSPECTION no approved drawings onsite no drawing for retaining wall footing onsite | |||
| FOOTER | 04/13/2021 | Disapproved - NO FEE | BGREVE |
| Note: no drawing for retaining wall footing onsite | |||
| ROW - DRAINAGE | 03/19/2021 | Disapproved -FEE REQUIRED | KRUTH |
| Note: THIS IS A REINSPECTION There is alot of sediment in the saltwater canal that needs to be removed. Personaly I would remove this before building the slab. | |||
| ROW - DRAINAGE | 03/15/2021 | Disapproved - NO FEE | KRUTH |
| Note: There is alot of sediment in the saltwater canal that needs to be removed. Personaly I would remove this before building the slab. | |||
| ROW - DRAINAGE | 03/08/2021 | APPROVED - AS NOTED | KRUTH |
| Note: THIS IS A REINSPECTION Per builder, calling to have a silt fence across the rear sea wall immediately to prevent sediment washout into the Canal. Next inspection 3/8/21. Corrections made next inspection 3/15/21 | |||
| ROW - DRAINAGE | 03/04/2021 | Disapproved - NO FEE | RGROSS |
| Note: Per builder, calling to have a silt fence across the rear sea wall immediately to prevent sediment washout into the Canal. Next inspection 3/8/21. | |||
| WATER METER INSTALLATION REQUEST | 01/14/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/26/2021 | 08/27/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 08/17/2021 | 08/18/2021 |
| Note: Released By: JORDAN MYERS, C.F.M - (904)562-0045 - JMYERS@PALMCOASTGOV.COM The building elevation certificate has been approved. However, at final please list the BFE in B9 as 7.0' not 7 feet so as to match elevations in Section C. | |||
| ENGIN1 | COMPLETE | 06/18/2021 | 06/18/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/18/2021 | 06/19/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 03/15/2021 | 03/15/2021 |
| Note: Held By: JEANNE MONTARULI - - jmontaruli@ci.palm-coast.fl.us Please specify what the revisions are and what departments need to review it | |||
| BADMIN | COMPLETE | 03/15/2021 | 03/15/2021 |
| Note: Released By: JEANNE MONTARULI - - jmontaruli@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 03/15/2021 | 03/22/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us Revision - added retaining wall. Refer to revised plans dated 3/15/21 | |||
| PLFM | COMPLETE | 01/04/2021 | 01/04/2021 |
| Note: Released By: JMYERS The construction elevation certificate has been accepted. However, on the building elevation certificate, please list the BFE in B9 as 7.0' not 7 feet. | |||
| PLFM | HOLD | 12/29/2020 | 12/29/2020 |
| Note: Held By: JMYERS In Section A1. there needs to be a building owner's name. In Section A8. a,b,c and A9. b,c needs to be N/A not 0 if there are no flood openings. Section B1, B2, and B3 are blank, they need to be completed. In Section B8 and B9 please only list the AE zone and the 7.0' as the Base Flood Elevation. In Section C2, you need to list the Benchmark Utilized and the Vertical Datum. | |||
| ZON | COMPLETE | 12/29/2020 | 12/29/2020 |
| Note: Released By: ELENS | |||
| BLD | COMPLETE | 12/14/2020 | 12/15/2020 |
| Note: Released By: PBUCKLEY You are advised to upload the mullion product approval number as a revision sometime before window inspection so as not to be delayed by an inspection failure for not having it on your product aproval worksheet. | |||
| SWALE | COMPLETE | 12/02/2020 | 02/12/2021 |
| Note: Released By: TBAKER | |||
| ZON | HOLD | 12/01/2020 | 12/01/2020 |
| Note: Held By: ELENS Please provide rear setback on the site plan. | |||
| PLFM | HOLD | 12/01/2020 | 12/01/2020 |
| Note: Held By: JMYERS According to the updated Site Plan, the structure will fall inside of the Special Flood Hazard Area. Elevation certificates will be required at construction, foundation, and final. | |||
| ENGIN1 | COMPLETE | 12/01/2020 | 12/02/2020 |
| Note: Released By: TBAKER | |||
| MECH | COMPLETE | 12/01/2020 | 12/01/2020 |
| Note: Released By: CPISCITELLI | |||
| ELEC | COMPLETE | 12/01/2020 | 12/01/2020 |
| Note: Released By: JMUNSON | |||
| BLD | HOLD | 12/01/2020 | 12/03/2020 |
| Note: Held By: JPI repeating comments 1. Sheet 9-S calls out 15# felt underlayment, roofing worksheet calls out 30# and the Product Approval sheet has no underlayment listed. Please cure. 2. Product approval sheet has no mullions listed and the project appears to contain them. Please cure. | |||
| BLD | HOLD | 11/10/2020 | 11/17/2020 |
| Note: Held By: JPI 1. Sheet 9-S calls out 15# felt underlayment, roofing worksheet calls out 30# and the Product Approval sheet has no underlayment listed. Please cure. 2. Product approval sheet has no mullions listed and the project appears to contain them. Please cure. | |||
| CUSVC | COMPLETE | 11/10/2020 | 11/13/2020 |
| Note: Released By: HHAND | |||
| ELEC | HOLD | 11/10/2020 | 11/13/2020 |
| Note: Held By: JMUNSON Provide floor plan showing square footage of home | |||
| ENGIN1 | HOLD | 11/10/2020 | 11/11/2020 |
| Note: Held By: TBAKER No benchmark on ssurvey | |||
| LOCATE | COMPLETE | 11/10/2020 | 11/13/2020 |
| Note: Released By: CSTONE | |||
| MECH | HOLD | 11/10/2020 | 11/12/2020 |
| Note: Held By: CPISCITELLI Provide floor plan showing square footage of home | |||
| PLUM | COMPLETE | 11/10/2020 | 11/17/2020 |
| Note: Released By: JPI | |||
| SW1 | COMPLETE | 11/10/2020 | 11/17/2020 |
| Note: Released By: KRUTH | |||
| ZON | HOLD | 11/10/2020 | 11/10/2020 |
| Note: Held By: ELENS Site plan: Need to upload a site plan that contains: - Legal description - Setbacks to all property lines (including the setback from the A/C pad) - FEMA map panel number and flood zone - Easements - Driveway width and material (including driveway width at the garage door) - Lot dimensions and total lot area Landscape plan - 8 foundation plantings are required across the front, 4 on each side (in addition to the A/C screening), and 4 in the rear facing the public right of way. Floor plan - Not provided. Please upload a floor plan so that Zoning may complete the review. (FYI- The foundation plan garage orientation does not match the site plan and landscape plan) | |||
| PLFM | HOLD | 11/10/2020 | 11/10/2020 |
| Note: Held By: JMYERS Please provide an updated survey and Site Plan that shows the proposed building and the Special Flood Hazard Area that resides on the lot. Should the structure or accessory machinery fall within the SFHA, 3 elevation certificates will be required. One at construction, foundation, and final. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/09/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 06/09/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 06/09/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/30/2021 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/30/2021 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/30/2021 |
| CONTRACTOR CHANGE | ¤40.00 | 09/30/2021 |
| CONTRACTOR CHANGE | ¤40.00 | 08/04/2021 |
| CONTRACTOR CHANGE | ¤40.00 | 08/04/2021 |
| CONTRACTOR CHANGE | ¤40.00 | 08/04/2021 |
| REINSPECTION FEE | ¤40.00 | 08/04/2021 |
| REINSPECTION FEE | ¤40.00 | 08/04/2021 |
| STORMWATER REINSPECTION FEE | ¤40.00 | 08/04/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤50.22) | 01/12/2021 |
| SEWER CREDIT | (¤1,146.12) | 01/12/2021 |
| SEWER INSPECTION | ¤25.00 | 01/12/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 01/12/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 01/12/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤568.00 | 01/12/2021 |
| SITE PLAN 20 | ¤20.00 | 01/12/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 01/12/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 01/12/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 01/12/2021 |
| CONNECTION FEES | ¤1,017.83 | 01/12/2021 |
| CONTRACTOR CHANGE | ¤40.00 | 01/12/2021 |
| METER - DEPOSIT | ¤60.00 | 01/12/2021 |
| WATER- TURN ON | ¤25.00 | 01/12/2021 |
| ADMIN FEE | ¤20.00 | 01/12/2021 |
| BUILDING DISCOUNT 100% | (¤1,392.80) | 01/12/2021 |
| ELECTRIC FEE | ¤230.40 | 01/12/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 01/12/2021 |
| IMPACT FEE FIRE | ¤367.00 | 01/12/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 01/12/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 01/12/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,674.00 | 01/12/2021 |
| MECHANICAL FEE | ¤230.40 | 01/12/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 01/12/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 01/12/2021 |
| PLAN CHECK FEE | ¤113.60 | 01/12/2021 |
| PLUMBING FEE | ¤230.40 | 01/12/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,462.63 |