Permit #2020120935

Permit Details

Status: COED

Parcel Id: 10-11-30-4937-00000-0040
Total Square Footage: 2500 sqft
Block: 00000
Subdivision: 2262 - PALM COAST INDUSTRIAL PARK
Job Phone: 386-238-1570
Location Address: 11 INDUSTRY DR
Type: CA - COMM ADDITION
Issue Date: 02/18/2021
NOC: RECORDED
Applicant name: GARY LYNN ROBERTS
Owner: US INVESTMENT HOLDING GROUP INC

Address

5725 REDWOOD DRIVE

ROHNERT PARK, CA 94928

Lot: 0040
Contracted Stated Job Value: ¤547,544.00
Job Description: EXTERIOR RENOVATIOS - WAREHOUSE ADDITION
Type: CN

Contractor

COMMERCIAL CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

7 SUNSHINE BLVD

ORMOND BEACH, FL 32174

CGC059441 (Exp: 08/31/2026) 386-238-1570 386-238-1571

Sub Contractors

MICHAEL WAYNE LYNCH
Status Location Address State License Number Phone
CANCEL

804 ROOT ST

DAYTONA BEACH, FL 32114

ER13015553 (Exp: 08/31/2022) 386-252-2287
ISAAC WALTER JOHNSTON
Status Location Address State License Number Phone
ACTIVE

887 BRENTWOOD DRIVE

Daytona Beach, FL 32117

CFC023634 (Exp: 08/31/2026) (386) 252-7047

Inspection History

Type Request Date Result Inspector
BUILDING FINAL 09/07/2021 FINAL APPROVED LMILLER
FIRE FINAL 09/07/2021 APPROVED LMILLER
U - UTILITY COMMERCIAL FINAL 09/07/2021 FINAL APPROVED LFITZGERALD
FIREWALL PENETRATIONS 09/03/2021 APPROVED - AS NOTED RMARTIN
Note: FOREST DID THIS INSPECTION ON THE FIREWALL FINAL
INSULATION 09/02/2021 APPROVED CPISCITELLI
Note: based on insulation report submitted, insulation inspection for foam insulation in bay is approved
ELECTRIC 2ND ROUGH 08/27/2021 APPROVED - AS NOTED RMARTIN
Note: DIS THIS UNDER 1ST ROUGH INSPECTION
ELECTRIC FINAL 08/27/2021 APPROVED RMARTIN
HVAC ROUGH 08/26/2021 APPROVED CPISCITELLI
HVAC FINAL 08/26/2021 FINAL APPROVED CPISCITELLI
FIREWALL FINAL 08/13/2021 FINAL APPROVED FWILLIS
FIREWALL DRYWALL NAILING 07/13/2021 APPROVED FWILLIS
FIREWALL DRYWALL NAILING 07/06/2021 APPROVED FWILLIS
Note: 1st layer
FIREWALL DRYWALL NAILING 06/30/2021 APPROVED FWILLIS
FIREWALL DRYWALL NAILING 06/28/2021 APPROVED FWILLIS
Note: Third Layer on End Unit.
FIREWALL NAILING 06/23/2021 APPROVED FWILLIS
Note: SHAFT WALL
FIREWALL FRAMING 06/23/2021 APPROVED FWILLIS
Note: THIS IS A REINSPECTION SECOND LAYER Next Inspection 3 layers Firewall screw.
FIREWALL DRYWALL NAILING 06/18/2021 APPROVED FWILLIS
Note: Includes Shaft Wall. (Firewall) (First Layer)
ELECTRIC OTHER 06/09/2021 APPROVED - AS NOTED RMARTIN
Note: INTERIOR WALLS, SHOULD HAVE BEEN 2ND ROUGH
FIREWALL FRAMING 06/07/2021 PARTIALLY APPROVED FWILLIS
Note: Next Inspection 3 layers Firewall screw.
FRAMING 06/03/2021 APPROVED FWILLIS
FIREWALL NAILING 06/03/2021 APPROVED FWILLIS
LINTEL 05/20/2021 APPROVED FWILLIS
FIREWALL NAILING 05/18/2021 APPROVED FWILLIS
Note: Dens Glass
FRAMING 05/07/2021 APPROVED FWILLIS
Note: East Side Metal columns.
FRAMING 04/16/2021 APPROVED FWILLIS
Note: Columns
MONOLITHIC SLAB 03/23/2021 APPROVED JBODEN
PLUMBING 1ST ROUGH 03/18/2021 APPROVED JGIBSON

Review History

Department Status Date In Date Out
MECH COMPLETE 09/02/2021 09/02/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/02/2021 09/03/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 08/30/2021 08/30/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide updated report. Report date is expired
MECH HOLD 08/30/2021 08/30/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide updated report. Report date is expired
MECH COMPLETE 03/08/2021 03/09/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
BADMIN HOLD 02/22/2021 02/22/2021
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM PG M-1 DOES NOT HAVE DIGITAL SIGNATURE
BLD COMPLETE 02/22/2021 03/05/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
MECH COMPLETE 02/22/2021 02/23/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 02/22/2021 02/22/2021
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM
DSD COMPLETE 02/01/2021 02/08/2021
Note: Released By: DRAMIREZ
ELEC COMPLETE 02/01/2021 02/03/2021
Note: Released By: JMUNSON
MECH COMPLETE 02/01/2021 02/03/2021
Note: Released By: CPISCITELLI
FI1 COMPLETE 02/01/2021 02/12/2021
Note: Released By: JBODEN
BLD COMPLETE 02/01/2021 02/18/2021
Note: Released By: PBUCKLEY
PLUM COMPLETE 02/01/2021 02/17/2021
Note: Released By: PBUCKLEY
BLD HOLD 12/21/2020 01/06/2021
Note: Held By: PBUCKLEY All references below to the 2017 Florida Building Code-Building and Florida Building Code-Existing Building. 1. Provide Site Plan drawn in accordance with Section 107.2.5. Include dimensions to all property lines and / or public ways from closest point of each side of exiting and addition. Show flood hazard areas and all other information outlined in this section. 2. Provide complete code analysis using the Florida Building Code - Existing Building per Chapters 5, 8 and 11. Also use Chapter 3, 5 and 6 of the Florida Building Code - Building as necessary. Provide occupancy classification for existing and proposed addition. Provide construction type for exiting and proposed addition. Provide allowable area and height calculations vs. actual area and height. If area increases are necessary show them and calculations. If this is a mixed occupancy building (does the building contain B occupancy offices?) then show calculations for mixed occupancy building. Provide plumbing fixture calculations for existing and new addition per Chapter 29. Note, if work is performed in this building and it is not purely storage the occupancy classification will be either F-1 or F-2 and not storage. Also note, if this building manufacturer’s or otherwise works on boats it will be an F-1 occupancy. Also note, if either than an S-1 or F-1 occupancy, an automatic NFPA fire sprinkler system is required throughout per Section 903.2.4 Florida Building Code-Building and Section 1102.3 Florida Building Code-Building based on area of the building exceeding 12,000 square feet. Also note, the existing building, if an F-1 occupancy is not eligible for the Exception to Section 1102.3. 3. Correct permit application to include reference to enclosing 5,000 square feet square of existing open warehouse in addition to the 2,500 square foot addition. 4. Submit geotechnical investigation report signed and sealed by a Florida licensed professional engineer per Section 1803.2. Report to comply with Section 1803.6. 5. Add note on Plan Sheet AB-2 indicating all foundation / slab will be removed along with CMU walls and lawfully disposed of. If there is an existing door opening onto this slab / open structure please also add note indicating a landing will be provided on the exterior side of door. Provide landing dimensions Provide exterior landing details on Plan Sheet D-1 where new doors are added per Notes 2, 5 and 12. 6. Additional plan review comments may result after submittal of site plan and code analysis.
DSD HOLD 12/21/2020 12/22/2020
Note: Held By: DRAMIREZ An application package for a Development Order approval must be submitted for review to include landscape plans and architectural plans.
ELEC HOLD 12/21/2020 12/22/2020
Note: Held By: JMUNSON 1. Submit electrical drawings 2. Submit interior lighting compliance certificate. FBC 2017 Energy Code
FI1 HOLD 12/21/2020 01/06/2021
Note: Held By: WMILLER 1. Provide code analysis showing occupancy classification and building construction type for building and addition per Chapter 3 and 5 FBC Building 2017 6Th edition and Chapter 5 and 11 FBC Existing Building 2017 6Th edition. 2. Please provide Occupancy classification per NFPA 101 3. Please proved Please provide complete Life Safety Plan per FFPC I Fire Code 10.14.3.4.3 (1-7G) for review.
MECH HOLD 12/21/2020 12/29/2020
Note: Held By: CPISCITELLI 1. Provide code analysis showing occupancy classification and building construction type for building and addition per Chapter 3 and 5 FBC Building 2017 6Th edition and Chapter 5 and 11 FBC Existing Building 2017 6Th edition. 2. Provide ventilation calculation per 403.3.1.1 FBC Mechanical 2017 6Th edition. 3. Provide mechanical exhaust details per Section 502 FBC Mechanical 2017 6Th edition
PLUM HOLD 12/21/2020 01/06/2021
Note: Held By: PBUCKLEY Not deteremined yet whether a plumbing code review is required for this project. Additional information is required as noted in the Building review HOLD.
UD1 COMPLETE 12/21/2020 01/05/2021
Note: Released By: CJOHNSON

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN COMMERCIAL ¤60.00 02/18/2021
INSPECTION - COMMERCIAL ADD ¤3,832.81 02/18/2021
BUILDING DISCOUNT 100% (¤5,299.55) 02/18/2021
ELECTRIC FEE ¤388.53 02/18/2021
PLAN CHECK FEE ¤629.68 02/18/2021
PLUMBING FEE ¤388.53 02/18/2021
SITE PLAN 20 ¤20.00 02/18/2021
SURCHARGE FS 533.721 ¤2.00 02/18/2021
SURCHARGE - FS 468.631 ¤2.00 02/18/2021
Fees Total Due: ¤0.00 Total Paid: ¤24.00