Permit Details

Status: STATE

Parcel Id: 09-12-31-0000-02030-0020
Block: 02030
Subdivision: -
Job Phone: 904-551-3003
Location Address: 60 MEMORIAL MEDICAL PKWY
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 04/20/2021
NOC: RECORDED
Applicant name: DANIEL TODD DAVIS
Owner: MEMORIAL HOSPITAL-FLAGLER INC

Address

60 MEMORIAL MEDICAL PKWY

PALM COAST, FL 32164

Lot: 0020
Contracted Stated Job Value: ¤79,000.00
Job Description: 2ND FLOOR - ICU - INTERIOR REPAIRS - CIRCUIT WORK-ELECTRICAL ONLY
Type: CN

Contractor

COMMERCIAL CONSTRUCTION SERVICES INC
Status Location Address State License Number Phone Fax
ACTIVE

3621 ST AUGUSTINE RD

JACKSONVILLE, FL 32207

CBC1259753 (Exp: 08/31/2026) 904-551-3003 904-551-9637

Sub Contractors

DANIEL AUTREY BROWN
Status Location Address State License Number Phone Fax
ACTIVE

2251 ROSSELLE STR

JACKSONVILLE , FL 32204

EC13004785 (Exp: 08/31/2026) 904-388-8000 904-384-9446

Inspection History

Type Request Date Result Inspector
ELECTRIC 2ND ROUGH 05/06/2021 PARTIALLY APPROVED RMARTIN
Note: Jeff - 904-631-2717 ROOM 2312
ELECTRIC 2ND ROUGH
Note: THIS IS A REINSPECTION Jeff - 904-631-2717 ROOM 2312
ABOVE CEILING
BUILDING FINAL

Review History

Department Status Date In Date Out
FI1 COMPLETE 02/05/2021 02/22/2021
Note: Released By: WILLIAM MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
BLD COMPLETE 02/05/2021 02/22/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD HOLD 12/21/2020 01/07/2021
Note: Held By: PBUCKLEY Permit application and confirmation from CSS license holder, Mr. Dan Davis, indicate this permit is for electrical work only associated with the lifts. However, mechanical plan sheets along with product vendor sheets for the lift systems have been uploaded for this permit. Mechanical plan sheets indicate some temporary mechanical air filtering work to be performed using Negative Air Machines (does not require a permit), but also indludes information suggesting field modifications to duct systems and some new duct work is proposed as part of this project. Since the contractor is not responsible for this work, a separate permit will be required for mechancal work as decribed on the mechanical plan sheets. CSS also indicated the installation of lift equipment is not in their scope of work either and is he responsibility of the vendor's contractor. Installation of lift equipment involves modifications to structural concrete floors, albeit it what appears to be insignificant work. However, that structural work also requires permit. Based on our understanding the scope of work is correct on the permit application, we will need to remove electrical, mechanical, vendor and other plan sheets from this permit so it can be issued. Separate permtis will be required as noted above. I need confirmation of this approach and need to reach out to the hospital PM to tell them they need to get additional permits. Please call Patrick Buckley 386-986-3786 Thank you
DSD COMPLETE 12/21/2020 12/22/2020
Note: Released By: DRAMIREZ No exterior work. All interior.
ELEC COMPLETE 12/21/2020 12/28/2020
Note: Released By: JMUNSON
FI1 HOLD 12/21/2020 01/06/2021
Note: Held By: WMILLER Please place the following note on the cover sheet... 1. Note for Existing Sprinklers and or Fire Alarms: Any construction alterations having effect on the building fire sprinkler and or Fire Alarms system layout and coverage, shall be addressed by a fire protection contractor under separate permit prior to project completion and approval. 2. Need Life Safety Plan to include travel distance from most remote location, exit and travel distance to extinguishers, extinguisher location, exit signs at egress/ingress and visible from any exit access path from any office/room and bathroom. Per FFPC 6th edition and AHJ
MECH COMPLETE 12/21/2020 12/22/2020
Note: Released By: CPISCITELLI
UD1 COMPLETE 12/21/2020 12/22/2020
Note: Released By: CJOHNSON

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMIN COMMERCIAL ¤60.00 04/20/2021
INSPECTION - COMMERCIAL ADD ¤553.00 04/20/2021
BUILDING DISCOUNT 100% (¤820.40) 04/20/2021
ELECTRIC FEE ¤107.40 04/20/2021
PLAN CHECK FEE ¤100.00 04/20/2021
SITE PLAN 20 ¤20.00 04/20/2021
SURCHARGE FS 533.721 ¤2.00 04/20/2021
SURCHARGE - FS 468.631 ¤2.00 04/20/2021
Fees Total Due: ¤0.00 Total Paid: ¤24.00