Permit #2020121153

Permit Details

Status: COED

Parcel Id: 06-12-31-5815-00000-0140
Total Square Footage: 6398 sqft
Subdivision: 2118 - TOWN CENTER PHASE I
Job Phone: 386-677-8736
Location Address: 18 MARKET AVE
Type: BC - BUILDING COMMERCIAL
Issue Date: 05/27/2021
NOC: RECORDED
Applicant name: LEONARD MARINACCIO III
Owner: CAPSTONE PLANNING LLC

Address

31 LUPI COURT STE 120

PALM COAST, FL 32137

Lot: 14
Contracted Stated Job Value: ¤823,640.00
Job Description: Office Building- Capstone Planning
Type: CN

Contractor

BOMAR CONSTRUCTION, INC.
Status Location Address State License Number Phone Fax
ACTIVE

27 SOUTH ORCHARD STREET

ORMOND BEACH, FL 32174

CGC1517931 (Exp: 08/31/2026) 386-677-8736 386-677-7726

Sub Contractors

MICHAEL WAYNE LYNCH
Status Location Address State License Number Phone
CANCEL

804 ROOT ST

DAYTONA BEACH, FL 32114

ER13015553 (Exp: 08/31/2022) 386-252-2287
FREDERICK JOSEPH PREVOST
Status Location Address State License Number Phone Fax
ACTIVE

887 BRENTWOOD DRIVE

DAYTONA BEACH, FL 0

CMC1250152 (Exp: 08/31/2026) 386-252-7047 386-257-7819
ISAAC WALTER JOHNSTON
Status Location Address State License Number Phone
ACTIVE

887 BRENTWOOD DRIVE

Daytona Beach, FL 32117

CFC023634 (Exp: 08/31/2026) (386) 252-7047
STUART A LYONS
Status Location Address State License Number Phone Fax
INACTIVE

2393 Bellevue Ave. Ext.

DAYTONA BEACH, FL 32114

CCC032500 (Exp: 08/31/2024) (386) 257-1007 (386)257-9040

Inspection History

Type Request Date Result Inspector
U - UTILITY COMMERCIAL FINAL 06/30/2022 FINAL APPROVED JHARDING
Note: THIS IS A REINSPECTION Backflows need to be tested, need wire test and tags. Backflows were tested 6/29/22
EXTERIOR ARCHITECTURAL FEATURES 06/24/2022 APPROVED JHARDING
U - UTILITY COMMERCIAL FINAL 06/24/2022 Disapproved - NO FEE JHARDING
Note: Backflows need to be tested, need wire test and tags
BUILDING FINAL 06/24/2022 FINAL APPROVED DCUSHING
Note: need H/C parking signs prior to Util final
ELECTRIC FINAL 06/24/2022 APPROVED RMARTIN
Note: THIS IS A REINSPECTION NEED ARC SHIELDS IN REST ROOMS NEC 314.20, NEED CORRECT BREAKERS ON AIR HANDLERS, NEED TO HAVE PLAN REVISED SHOW LIGHTING/OUTLET CONTROL SYSTEM CHANGE OR MAKE JOB MATCH PLAN - NEC 406.3 E
GRAVITY SEWER 06/22/2022 APPROVED MGIBSON
PLUMBING FINAL 06/22/2022 APPROVED - AS NOTED MGIBSON
Note: NEED SHOCK ARRESTOR FOR FUTURE DISHWASHER LINE,BUY BUILDING FINAL
HVAC FINAL 06/21/2022 FINAL APPROVED CPISCITELLI
Note: THIS IS A REINSPECTION
HVAC FINAL 06/14/2022 Disapproved - NO FEE CPISCITELLI
Note: AHU's call for 45 AMP breakers. There are 60 AMP in panel
ELECTRIC FINAL 06/14/2022 Disapproved - NO FEE RMARTIN
Note: NEED ARC SHIELDS IN REST ROOMS NEC 314.20, NEED CORRECT BREAKERS ON AIR HANDLERS, NEED TO HAVE PLAN REVISED SHOW LIGHTING/OUTLET CONTROL SYSTEM CHANGE OR MAKE JOB MATCH PLAN - NEC 406.3 E
FIRE FINAL 06/10/2022 APPROVED RMARTIN
Note: THIS IS A REINSPECTION
FIRE FINAL 06/09/2022 CANCELLED BY APPLICANT RMARTIN
BLD - SEWER TIE IN 06/02/2022 APPROVED MGIBSON
ABOVE CEILING 05/17/2022 APPROVED JMUNSON
Note: THIS IS A REINSPECTION JUST LID OVER DROP CEILING
ELECTRIC - EARLY POWER 04/29/2022 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 2:40 PM
ROOF VALLEY & METAL 04/08/2022 APPROVED JWALKER
LATH/BRICK/WATER BARRIER 03/25/2022 APPROVED JWALKER
MONOLITHIC SLAB 03/21/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION Multiple areas of soil have washed into footings.
ELECTRIC 2ND ROUGH 03/16/2022 APPROVED RMARTIN
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION LOOKED AT THE LID, OVER THE ABOVE CEILING 3/4/22 marked on print missing
MONOLITHIC SLAB 03/16/2022 Disapproved - NO FEE JWALKER
Note: Multiple areas of soil have washed into footings.
PLUMBING 2ND ROUGH 03/04/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION WASTE AND VENT HEAD TEST APPROVED, NEED NAIL PLATES IN MULTIPLE AREAS 2'' ABOVE BOTTOM PLATE AND TOP PLATE BOTH SIDES IN AREAS DISCUSSED WITH PLUMBER
ELECTRIC 2ND ROUGH 03/04/2022 PARTIALLY APPROVED RMARTIN
Note: THIS IS A REINSPECTION LOOKED AT THE LID, OVER THE ABOVE CEILING 3/4/22 marked on print missing
HVAC ROUGH 03/03/2022 APPROVED - AS NOTED CPISCITELLI
Note: THIS IS A REINSPECTION ADDED ON 2/2/2022 2:09:24 PM Missing returns in 6 rooms 1- duct in hall not attached Trunk line in back office needs resealing on seam See marking on plans
PLUMBING 2ND ROUGH 03/03/2022 PARTIALLY APPROVED MGIBSON
Note: WASTE AND VENT HEAD TEST APPROVED, NEED NAIL PLATES IN MULTIPLE AREAS 2'' ABOVE BOTTOM PLATE AND TOP PLATE BOTH SIDES IN AREAS DISCUSSED WITH PLUMBER
FRAMING 03/03/2022 APPROVED - AS NOTED JWALKER
Note: Have engineer submitt an as built drawing for bracing the interior steel stud framed walls. Due to the walls not going from ceiling to floor as per the detail.
INSULATION 03/03/2022 APPROVED JWALKER
INSULATION 02/03/2022 APPROVED JWALKER
ABOVE CEILING 02/02/2022 PARTIALLY APPROVED RMARTIN
Note: JUST LID OVER DROP CEILING
HVAC ROUGH 02/02/2022 PARTIALLY APPROVED CPISCITELLI
Note: Inspected duct above hard ceiling on front right of building. Need to fix a ripped duct and seal one connectiom
ELECTRIC 2ND ROUGH 02/02/2022 PARTIALLY APPROVED RMARTIN
Note: LOOKED AT THE LID, OVER THE ABOVE CEILING
ROOF SHEATHING / BRACE / TIE DOWN 01/24/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION 1/20/22 The rear canopy. Truss V07,8,9,10,11 are not straped or blocked as per MITek details. Truss T27 missng hold down anchors and one engineering, T28 missing hold down straps. Multiple Meta straps are missing fasteners, 8 fasteners per strap. check all. The 5 Trusses To7 right side of the building out of plumb. Page S0.1 of the prints Note 8 The bottom chord cross bracing not installed. Trusses T22x4, T21, 20,19,18,17,16 right side of building at the girder are not within plumb tolerances and have been set out of layout. Fix all.
STOREFRONT 01/21/2022 APPROVED - AS NOTED JWALKER
Note: This inspection was for window frame fastening.
ROOF SHEATHING / BRACE / TIE DOWN 01/20/2022 Disapproved - NO FEE JWALKER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1/20/22 The rear canopy. Truss V07,8,9,10,11 are not straped or blocked as per MITek details. Truss T27 missng hold down anchors and one engineering, T28 missing hold down straps. Multiple Meta straps are missing fasteners, 8 fasteners per strap. check all. The 5 Trusses To7 right side of the building out of plumb. Page S0.1 of the prints Note 8 The bottom chord cross bracing not installed. Trusses T22x4, T21, 20,19,18,17,16 right side of building at the girder are not within plumb tolerances and have been set out of layout. Fix all.
ROOF VALLEY & METAL 01/19/2022 APPROVED JWALKER
Note: Inspection for ployiso fastening at flat roof.
EXTERIOR WALL SHEATHING / SHEARWALL 01/06/2022 APPROVED JWALKER
ROOF SHEATHING / BRACE / TIE DOWN 01/06/2022 CANCELLED BY APPLICANT JWALKER
Note: THIS IS A REINSPECTION
ROOF SHEATHING 01/06/2022 APPROVED JWALKER
Note: THIS IS A REINSPECTION Marked areas of missed nailing with orange paint. There are two area at the bottom of the 10:12 roof right side of the building edge nailing is missing. Not marked Also marked areas where blocking needs to be installed. The plywood at the front gable where it transition from 10:12 to 8 needs to be cut
ROOF SHEATHING 01/05/2022 Disapproved - NO FEE JWALKER
Note: Marked areas of missed nailing with orange paint. There are two area at the bottom of the 10:12 roof right side of the building edge nailing is missing. Not marked Also marked areas where blocking needs to be installed. The plywood at the front gable where it transition from 10:12 to 8 needs to be cut
ROOF SHEATHING / BRACE / TIE DOWN 01/05/2022 CANCELLED BY APPLICANT JWALKER
FOUNDATION SURVEY - OFFICE USE ONLY 12/13/2021 APPROVED DLEAP
LINTEL 12/08/2021 APPROVED - AS NOTED JWALKER
Note: The expansion joints at the cmu wall have been stopped two courses below the top of wall. Please provide a detail showing the expansion joint is to stop at this height. The contrator is approved to pour, At risk that the expansion joints will need to continue to the top of the CMU wall. .
DOWN CELL 12/08/2021 APPROVED JWALKER
LINTEL 12/01/2021 APPROVED - AS NOTED JWALKER
Note: THIS IS A REINSPECTION OK PER PATRICK 11/29/21 The block walls will need to be finished to full height the required 90 degree bend with 8" length and full continous down rods tied to the dowel at the footing will need to be installed as per details. Or have the engineer submitt a revision as to the current way the contractor is wanting to install the steel reinforcing bars. And the separate pour of the mortar 12/1/21 As per engineer revision contractor is approved to pour first lift to 9'8" on the main building 7'8" on the peir and columns.
LINTEL 11/29/2021 Disapproved - NO FEE JWALKER
Note: OK PER PATRICK 11/29/21 The block walls will need to be finished to full height the required 90 degree bend with 8" length and full continous down rods tied to the dowel at the footing will need to be installed as per details. Or have the engineer submitt a revision as to the current way the contractor is wanting to install the steel reinforcing bars. And the separate pour of the mortar
FOOTER 11/12/2021 APPROVED JWALKER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Soil cave in due to heavy rains.
MONOLITHIC SLAB 11/12/2021 APPROVED JWALKER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Caves in due to heavy rains. footing filled with water unable to see rebar clearance.
MONOLITHIC SLAB 11/08/2021 CANCELLED BY APPLICANT JWALKER
Note: THIS IS A REINSPECTION Caves in due to heavy rains. footing filled with water unable to see rebar clearance.
FOOTER 11/08/2021 CANCELLED BY APPLICANT JWALKER
Note: THIS IS A REINSPECTION Soil cave in due to heavy rains.
FOOTER 11/05/2021 Disapproved - NO FEE JWALKER
Note: Soil cave in due to heavy rains.
MONOLITHIC SLAB 11/05/2021 Disapproved - NO FEE JWALKER
Note: Caves in due to heavy rains. footing filled with water unable to see rebar clearance.
ELECTRIC UNDERGROUND 11/05/2021 APPROVED - AS NOTED RMARTIN
Note: BONDING STEEL
ELECTRIC 1ST ROUGH 10/28/2021 APPROVED JMUNSON
PLUMBING 1ST ROUGH 10/28/2021 APPROVED MGIBSON

Review History

Department Status Date In Date Out
ELEC COMPLETE 06/15/2022 06/16/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 06/09/2022 06/09/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 03/09/2022 03/16/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 01/26/2022 01/27/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
BLD HOLD 01/21/2022 01/24/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. If Engineer of recorded is certify the control joists, Engineer is to state FS 69G15-29.001 and 69G15-18.011 as well revise the drawing to reflect the changes.
ELEC COMPLETE 01/21/2022 01/24/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 01/21/2022 01/24/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 01/21/2022 01/24/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 12/14/2021 12/15/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
PLENG COMPLETE 12/13/2021 12/13/2021
Note: Released By: DENNIS R. LEAP, P.E. - - DLEAP@PALMCOASTGOV.COM
PLENG HOLD 12/06/2021 12/08/2021
Note: Held By: DENNIS R. LEAP, P.E. - - DLEAP@PALMCOASTGOV.COM Label Plan as "FOUNDATION SURVEY"
DSD COMPLETE 12/06/2021 12/08/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
BLD HOLD 11/30/2021 11/30/2021
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building PLAN REVIEW COMMENTS: Repeat Comments 1. Digital signature on engineer’s letter could not be verified. Please resubmit letter with a digital signature that could be verified.
BLD COMPLETE 11/30/2021 12/01/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 11/29/2021 11/30/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 11/18/2021 11/22/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH COMPLETE 07/06/2021 07/06/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 06/18/2021 06/21/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Heatload calculation needs to be revised. Origional heatload was submitted for revision
ARCHR COMPLETE 06/01/2021 06/15/2021
Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM
BLD COMPLETE 06/01/2021 06/14/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
MECH HOLD 06/01/2021 06/01/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide updated energy calculations 2. Provide updated heatload calculation 3. Provide sheet A1 showing occupancy changes for ventilation reduction
PLUM CANCEL 06/01/2021 06/14/2021
Note: No plumbing revisions submitted.
FI1 COMPLETE 06/01/2021 06/08/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 06/01/2021 06/01/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
FI1 COMPLETE 02/18/2021 03/03/2021
Note: Released By: WILLIAM MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
DSD COMPLETE 02/01/2021 02/18/2021
Note: Released By: DRAMIREZ
ARCHR COMPLETE 02/01/2021 02/08/2021
Note: Released By: DRAMIREZ
UD1 COMPLETE 02/01/2021 02/03/2021
Note: Released By: CJOHNSON
ELEC COMPLETE 02/01/2021 02/03/2021
Note: Released By: JMUNSON
MECH COMPLETE 02/01/2021 02/02/2021
Note: Released By: CPISCITELLI
FI1 HOLD 02/01/2021 02/04/2021
Note: Held By: WMILLER Please move FDC so that it is not blocked by parking. NFPA 24 5.9.5.2 FDC access cannot be obstructed
BLD COMPLETE 02/01/2021 02/11/2021
Note: Released By: JPI
ARCHR HOLD 12/28/2020 12/28/2020
Note: Held By: DRAMIREZ DO architectural plans must be approved prior to this permit approval. Architectural sheets states that it is sheet A.4 but it was named sheet A.7, please correct naming convention to match the index sheet.
BLD HOLD 12/28/2020 01/12/2021
Note: Held By: JPI 1. The review is incomplete at this time. Please address comments and the review will continue. FBC 107.3.5 2. Occupant load calculations on Page TBL and load calculations on A1 and A2 do not match. Please clarify. 3. Clarify the two-tenant use. Will tenants have access to entire building? Concern for bathroom counts and hi-lo use. 4. Provide roof and wall sheathing nailing patterns and provide attachment detail for valley truss. 5. Provide framing details for roof exhaust fan penetrations. Mechanical plans state see structural. 6. Provide locations of all fire extinguishers. 7. Note: Fire sprinkler plans will need to be submitted. 8. Please reply in writing to all comments.
DSD HOLD 12/28/2020 12/28/2020
Note: Held By: DRAMIREZ Development Order and Site Development permit must be issued prior to issuance of this permit.
ELEC HOLD 12/28/2020 01/05/2021
Note: Held By: JMUNSON 3/0 copper wire is not rated for 400 amps. NEC 2014 310.15 (B) (16)
FI1 HOLD 12/28/2020 01/12/2021
Note: Held By: WMILLER 1. on drawing list, life safety plan is indicated as sheet a1, however sheet a4 is the life safety plan, please correct one or the other. 2. please shoe extinguisher location on life safety plan per fbc 2017 section 906 3. please provide fire apparatus access/turn plan using the largest fire department apparatus (sutphen 2011 aerial tower) per ahj. 4. please place a separate note on the cover sheet indicating the need for separate permits for automatic fire suppression systems per ffpc, nfpa 1, fire code section 1.12.8 and fire alarms and detection systems and related equipment per ffpc, nfpa 1, fire code section 1.12.8 5. please upload utily page for review. (need to see the fire lines and fdc's
MECH HOLD 12/28/2020 01/06/2021
Note: Held By: CPISCITELLI Provide heatload calculation per C403.2.1 FBC Energy Conservation 2017 6Th Edition
PLUM COMPLETE 12/28/2020 01/12/2021
Note: Released By: JPI
UD1 HOLD 12/28/2020 01/05/2021
Note: Held By: CJOHNSON Utility fees and agreements shall be complete prior to issuance of the building permit

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/23/2022
PLAN REVIEW - REVISION ¤32.50 12/01/2021
PLAN REVIEW - REVISION ¤32.50 11/29/2021
ADMIN COMMERCIAL ¤60.00 05/27/2021
BUILDING DISCOUNT 100% (¤7,199.75) 05/27/2021
ELECTRIC FEE ¤554.18 05/27/2021
3% FIRE IMPACT FEE CREDIT (¤113.28) 05/27/2021
IMPACT FEE FIRE ¤3,776.00 05/27/2021
IMPACT FEE TRANSPORTATION ¤24,307.20 05/27/2021
MECHANICAL FEE ¤554.18 05/27/2021
PERMIT FEE ¤4,530.02 05/27/2021
PLAN CHECK FEE ¤947.19 05/27/2021
PLUMBING FEE ¤554.18 05/27/2021
SITE PLAN 20 ¤20.00 05/27/2021
SURCHARGE FS 533.721 ¤2.00 05/27/2021
SURCHARGE - FS 468.631 ¤2.00 05/27/2021
3% TRANS IMPACT FEE CREDIT (¤729.22) 05/27/2021
Fees Total Due: ¤0.00 Total Paid: ¤27,362.20