I want to search for...
Permit #2021010584
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-01020-0090 |
| SCREEN PORCH (SOLID ROOF) : 840 sqft |
| Total Square Footage: 840 sqft |
| Block: 01020 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: (386)246-9986 |
| Location Address: 98 EVANS DR |
| Type: PO - POOL |
| Issue Date: 05/19/2021 |
| NOC: RECORDED |
| Applicant name: MICHAEL L RYAN |
| Owner: MORTON MATTHEW T & WENDY A MORTON H&W |
|
Address 98 EVANS DRIVE PALM COAST, FL 32164 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤33,450.00 |
| Job Description: SWIMMING POOL / SCREEN ENCLOSURE |
| Type: CN |
Contractor
OHANU WATERS , INC
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| INACTIVE |
4490 N US 1 PALM COAST, FL 32164 |
SUITE 109 PALM COAST, FL 32164 |
CPC1457377 (Exp: 08/31/2024) | (386)246-9986 | (386)246-5374 |
Sub Contractors
JOSEPH DEREK CARTWRIGHT
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
151 RODEO ROAD ORMOND BEACH, FL 32174 |
SCC131150000 (Exp: 08/31/2026) | 386-310-7962 | (386)615-3713 |
RICHARD R EDWARDS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P. O. Box 1637 Bunnell, FL 32110 |
EC13010654 (Exp: 08/31/2026) | (386) 437-1537 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 08/08/2022 | FINAL APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Pool alarm not installed unable to test. | |||
| POOL FINAL | 07/08/2022 | Disapproved - NO FEE | JWALKER |
| Note: Pool alarm not installed unable to test. | |||
| U -UTILITY RESIDENTIAL FINAL | 04/07/2022 | FINAL APPROVED | JHARDING |
| ROW - FINAL INSPECTION | 04/06/2022 | APPROVED | PFLANAGAN |
| ELECTRIC AND ALARM | 03/03/2022 | APPROVED - AS NOTED | JMUNSON |
| Note: Pool alarm on site test on final | |||
| FINAL SURVEY (OFFICE USE ONLY) | 12/22/2021 | APPROVED | RGROSS |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/22/2021 | APPROVED | RGROSS |
| POOL DECK | 09/08/2021 | APPROVED | TSTAUFFACHER |
| STEEL AND GROUND | 05/27/2021 | APPROVED | TSTAUFFACHER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 02/11/2021 | 02/11/2021 |
| Note: Released By: PBUCKLEY | |||
| ELEC | COMPLETE | 02/02/2021 | 02/02/2021 |
| Note: Released By: JMUNSON | |||
| BLD | HOLD | 02/02/2021 | 02/09/2021 |
| Note: Held By: FREODICA 1. Master file of engineered pool plans can be used only after they are reviewed and approved with stamped for code compiance. The master file plans procedures are disussed below on item 3 below. 2. Review comments on submited master plans - General Notes (12), (13) & (14) a. Chapter 42 on 2020 FBC -Residential has been deleted. Keep Chapter 45 as Referenced Code to 2020 FBC- Residential or 7th Edition. b. Revise Electrical Code from 2014 to 2017 NEC on item (14). 3. Here is how we will treat pool master plan submittals. • All submittals will be done outside the CD Plus permitting system, submitted by email only. • Emailed plans are digital / electronic plans and shall have a verifiable digital seal and signature with date. • Plans shall include the name Master Plans or Master Pool Plans or similar and include a note or notes deemed necessary by the engineer indicating they are approved for repeated use by the pool contractor. The engineer can include an expiration date and other information the engineer wants to add. • Emailed submittals will be directly to me or to permit technician for review. . • Review comments will be emailed to the applicant and the applicant will send revised (digitally sealed plans) • When the review is completed and plans are ready to for approval, an email will be sent to the applicant letting them know to print out paper copies with ink or raised / embossed seal and signature with date and to bring them to the office for the City to add its approval stamp. • Plans with City approval stamp will be returned to the applicant. • Applicant can print photo-copies of the approved plans for use on site(s) for inspection. FReodica -386-986-4734. | |||
| BLD | HOLD | 01/15/2021 | 01/25/2021 |
| Note: Held By: FREODICA Pool plan -Sheet 1 of 4: Provide Updated Referenced Code on General Notes items 12, 13 and 14. FReodica -386-986-4734 | |||
| ELEC | HOLD | 01/15/2021 | 01/19/2021 |
| Note: Held By: JMUNSON Need to reference the 2017 NEC | |||
| MECH | COMPLETE | 01/15/2021 | 01/20/2021 |
| Note: Released By: CPISCITELLI | |||
| SW1 | COMPLETE | 01/15/2021 | 01/15/2021 |
| Note: Released By: CTROHA | |||
| ZON | COMPLETE | 01/15/2021 | 01/15/2021 |
| Note: Released By: AMOBLEY |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 07/07/2022 |
| BUILDING DISCOUNT 100% | (¤220.00) | 05/19/2021 |
| PERMIT FEE | ¤160.00 | 05/19/2021 |
| PLAN CHECK FEE | ¤40.00 | 05/19/2021 |
| SITE PLAN 20 | ¤20.00 | 05/19/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/19/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/19/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/19/2021 |
| ADMIN FEE | ¤20.00 | 05/19/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤144.00 |