Permit #2021010928
Permit Details
Status: COED
| Parcel Id: 07-11-31-7001-000A0-0079 |
| Total Square Footage: 1495 sqft |
| Block: 000A0 |
| Subdivision: 1238 - PALM HARBOR CENTER REPLAT |
| Job Phone: 386-585-2654 |
| Location Address: 25 PALM HARBOR VILLAGE WAY |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 04/19/2021 |
| NOC: RECORDED |
| Applicant name: DESIDERIO CARLOS CARREIRO |
| Owner: ACR HOLDINGS OF FLORIDA INC |
|
Address 25 PALM HARBOR VILLAGE WAY #9 PALM COAST, FL 32137 |
| Lot: 0079 |
| Contracted Stated Job Value: ¤80,000.00 |
| Job Description: SUITE 9- BUILDOUT FOR "TWISTERS ICE CREAM" |
| Type: CN |
Contractor
RED LINE CONSTRUCTION CO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6 COMMERCIAL CT PALM COAST, FL 32137 |
CGC1527392 (Exp: 08/31/2026) | 386-585-2654 |
Sub Contractors
ROBERT CARLTON LITTLE
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3050 EAST MOODY BLVD BUNNELL, FL 32110 |
EC13003740 (Exp: 08/31/2026) | 386-931-1708 |
DANIEL GOULDNER
| Status | Location Address | State License Number |
| ACTIVE |
400 OLD HAW CREEK RD BUNNELL, FL 32110 |
CAC1818907 (Exp: 08/31/2026) |
FERNANDO M FARIA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
23 FREELAND LANE PALM COAST, FL 32137 |
RF11067823 (Exp: 08/31/2027) | 386-569-4336 |
Inspection History
| Type | Request Date | Result | Inspector |
| PLUMBING FINAL | 08/16/2021 | Approval - Private Provider | PPROVIDER |
| HVAC FINAL | 08/16/2021 | Approval - Private Provider | PPROVIDER |
| BUILDING FINAL | 08/16/2021 | Approval - Private Provider | PPROVIDER |
| ELECTRIC FINAL | 08/16/2021 | Approval - Private Provider | BBEMBRY |
| U - UTILITY COMMERCIAL FINAL | 08/13/2021 | FINAL APPROVED | DHANEY |
| FIRE FINAL | 08/13/2021 | APPROVED | RMARTIN |
| U-GREASE INTERCEPTOR INSTALLED/PLUMBED | 08/12/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: ALL PLUMBING CONNECTIONS ARE MADE, FLOW AND DYE TEST DONE AND APPROVED BY OTHER INSPECTION | |||
| U-GREASE INTERCEPTOR FLOW/DYE TESTED | 08/12/2021 | APPROVED | DHANEY |
| ABOVE CEILING | 07/06/2021 | Approval - Private Provider | PPROVIDER |
| HVAC ROUGH | 06/29/2021 | Approval - Private Provider | PPROVIDER |
| ELECTRIC 2ND ROUGH | 05/27/2021 | CANCELLED BY APPLICANT | RMARTIN |
| Note: THIS INSPECTION IS PRIVATE PROVIDER | |||
| PLUMBING 1ST ROUGH | 05/27/2021 | CANCELLED BY APPLICANT | JGIBSON |
| PLUMBING 2ND ROUGH | 05/27/2021 | CANCELLED BY APPLICANT | JGIBSON |
| FRAMING | 05/27/2021 | CANCELLED BY APPLICANT | WMILLER |
| Note: Inspection cancelled (Private Provider inspections) | |||
| FRAMING | 05/20/2021 | Approval - Private Provider | PPROVIDER |
| Note: THIS IS A REINSPECTION Inspection cancelled (Private Provider inspections) | |||
| PLUMBING 2ND ROUGH | 05/20/2021 | Approval - Private Provider | PPROVIDER |
| Note: THIS IS A REINSPECTION | |||
| ELECTRIC 2ND ROUGH | 05/20/2021 | Approval - Private Provider | PPROVIDER |
| Note: THIS IS A REINSPECTION THIS INSPECTION IS PRIVATE PROVIDER | |||
| PLUMBING 1ST ROUGH | 04/20/2021 | Approval - Private Provider | PPROVIDER |
| Note: THIS IS A REINSPECTION |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/03/2021 | 08/11/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 08/02/2021 | 08/02/2021 |
| Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM your plans does not showing digitally . | |||
| MECH | COMPLETE | 04/01/2021 | 04/05/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/01/2021 | 04/16/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| UD1 | COMPLETE | 03/11/2021 | 03/12/2021 |
| Note: Released By: CHRIS JOHNSON - - cjohnson@ci.palm-coast.fl.us | |||
| ELEC | COMPLETE | 03/11/2021 | 03/16/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/11/2021 | 03/12/2021 |
| Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Entire heatload calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition 2. Provide ventilation calculation on plans per 403.3.1.1 FBC Mechanical 2020 7Th Edition (Second Request) | |||
| FI1 | COMPLETE | 03/11/2021 | 03/17/2021 |
| Note: Released By: WILLIAM MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/11/2021 | 03/25/2021 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Proposed bathroom finishes requested in the previous review do not comply with 2020 FBCB Sections 1210.2.1 and 1210.2.2. Please provide finish schedule that includes hard, non-absorbant finishes at toilets per these sections. | |||
| PLUM | COMPLETE | 03/11/2021 | 03/25/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/22/2021 | 02/05/2021 |
| Note: Held By: PBUCKLEY All references below to the 2020 Florida Building Code, Florida Plumbing Code, 2017 National Electrical Code and Palm Coast Revised Municipal Code. 1. Provide reference to the 2020 Florida Plumbing Code, 2020 Florida Mechanical Code and 2020 Florida Existing Building Code. You reference a Level II alteration but do not cite the code this reference is based on. 2. Change 2014 National Electrical Code Reference to 2017 National Electrical Code. 3. Revise Building Code Notes to reflect tenant space is a Group B Occupancy not a Group A. Tenant space has an occupant load of less than 50 therefore it is a Group B Occupancy. See FBC Section 303.1.1. 4. You may want to consider removing the seating area information as a seating plan is not required for a Group B occupancy. You may also wish to revise the total occupant load based on FBC Section 1004 and Table 1004.1 using a Group B-Business use which uses a gross floor area factor of 150. My calculations indicates the tenant space (65 ft X 23 ft) is 1,495 square feet overall. 1,495 / 150 = 9.96 (rounded to 10) occupants. 10 occupants means only one accessible unisex bathroom is required per Section 2902.2 Exception No. 4. This section states small business occupancies with an occupant load of less than 25 means you do not have to provide separate facilities. If you go this direction, please revise floor plan and plumbing riser diagram accordingly. 5. Provide bathroom finish floor and wall finish schedule per FBC Section 1210.21 and 1210.2.2. List compliant materials to be used. PLEASE call with any questions. Patrick Buckley 386-986-3786 | |||
| DSD | COMPLETE | 01/22/2021 | 01/26/2021 |
| Note: Released By: JGONZALEZ | |||
| ELEC | HOLD | 01/22/2021 | 01/27/2021 |
| Note: Held By: JMUNSON 1. Submit electrical load calcs. 2. Need to reference the 2017 NEC not the 2014 3. Need to show GFCI protection for equpiment. NEC 2017 210.8 (B) 4. Show amp ratings for equipment. | |||
| FI1 | HOLD | 01/22/2021 | 02/02/2021 |
| Note: Held By: WMILLER Please provide an additional extinguisher in the seating area so that it is not obstructed or obsured from view per NFPA 10, NFPA 10, 6.1.3.3.1 Please place the following note on the cover sheet: Any construction alterations having effect on the building fire sprinkler system and or fire alarm system layout and coverage, shall be addressed by a fire protection contractor under separate permit prior to project completion and approval per FFPC, NFPA 1, Fire Code section 1.12.8 | |||
| MECH | HOLD | 01/22/2021 | 01/27/2021 |
| Note: Held By: CPISCITELLI 1. Provide heatload calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition 2. Provide ventilation calculation per 403.3.1.1 FBC Mechanical 2020 7Th Edition 3. Provide specs on refrigeration equipment | |||
| PLUM | HOLD | 01/22/2021 | 02/05/2021 |
| Note: Held By: PBUCKLEY All references below to the 2020 Florida Building Code, Florida Plumbing Code, 2017 National Electrical Code and Palm Coast Revised Municipal Code. 1. Provide a condensate waste piping and discharge plan that routes all condensate wastes from all condensate producing appliance and equipment plan. Condensate waste cannot be discharged into the City’s waste-water collection system and must terminate separately, generally to an outside drywell or similar. Show location and construction of drywell. Palm Coast Revised Municipal Code Article IV, Section 49-104 (c) (12). PLEASE call with any questions. Patrick Buckley 386-986-3786. | |||
| UD1 | HOLD | 01/22/2021 | 01/27/2021 |
| Note: Held By: CJOHNSON A grease trap will be required. The 3 comp. sink and slop sink will need to be plumbed to grease trap. Contact Pat Garrett for exemption form and requirements for the grease trap. 386-931-2560. Provide completed DBPR form |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMIN COMMERCIAL | ¤60.00 | 04/19/2021 |
| INSPECTION - COMMERCIAL ADD | ¤560.00 | 04/19/2021 |
| BUILDING DISCOUNT 100% | (¤1,044.00) | 04/19/2021 |
| ELECTRIC FEE | ¤108.00 | 04/19/2021 |
| MECHANICAL FEE | ¤108.00 | 04/19/2021 |
| PLAN CHECK FEE | ¤100.00 | 04/19/2021 |
| PLUMBING FEE | ¤108.00 | 04/19/2021 |
| SITE PLAN 20 | ¤20.00 | 04/19/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/19/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/19/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤24.00 |