I want to search for...

Permit #2021011039

Permit Details

Status: FINAL

Parcel Id: 07-11-31-5112-00000-0110
Block: 00000
Subdivision: 1164 - PINE LAKES INDUSTRIAL PARK
Job Phone: 386-238-1570
Location Address: 4 COMMERCE BLVD
Type: CSD - COMMERCIAL SITE DEVELOPMENT
Issue Date: 02/02/2021
NOC: RECORDED
Applicant name: GARY LYNN ROBERTS
Owner: GIOIA PROPERTIES LLC

Address

10 COMMERCE BLVD

PALM COAST, FL 32164

Lot: 0110
Job Description: SITE WORK: GIOIA SALES SOUTH
Type: CN

Contractor

COMMERCIAL CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

7 SUNSHINE BLVD

ORMOND BEACH, FL 32174

CGC059441 (Exp: 08/31/2026) 386-238-1570 386-238-1571

Inspection History

Type Request Date Result Inspector
MAINT BOND ACCEPTANCE (OFFICE) 10/01/2021 APPROVED DRAMIREZ
CLOSE OUT DOCUMENTS 10/01/2021 APPROVED DRAMIREZ
Note: Irma approved all of the close out documents.
PLANNING - OFFICE USE - FINAL AS-BUILT SURVEY 09/30/2021 APPROVED DRAMIREZ
Note: As-builts approved under application 4894
UC-FINAL SITE INSPECTION 09/29/2021 FINAL APPROVED LFITZGERALD
U - UTILITY COMMERCIAL FINAL 09/29/2021 FINAL APPROVED LFITZGERALD
ROW - FINAL INSPECTION 09/29/2021 FINAL APPROVED LFITZGERALD
UC-SUBSTANTIAL WALK-THRU 09/28/2021 APPROVED LFITZGERALD
UC- PRELIMINARY AS-BUILTS 09/28/2021 APPROVED LFITZGERALD
BLD - SITE STRUCTURE - TRASH DUMPSTER 09/28/2021 FINAL APPROVED FWILLIS
BLD - SITE LIGHTING-PLACEMENT/FOUNDATION 09/28/2021 APPROVED JMUNSON
BLD - ADA RAMPS/SIDEWALKS/CROSSWALKS 09/28/2021 APPROVED FWILLIS
BLD- ADA PARKING 09/28/2021 APPROVED FWILLIS
BLD - ADA COMPLIANT 09/28/2021 CANCELLED BY APPLICANT WEB
BLD - ADA COMPLIANT 09/28/2021 APPROVED FWILLIS
BLD- ADA SIGNAGECONTROL 09/28/2021 APPROVED FWILLIS
BLD- ADA VEHICULAR WAY 09/28/2021 APPROVED FWILLIS
BLD - ADA SIGNAGE- INFOR/DIRECT 09/28/2021 APPROVED FWILLIS
UC-TRAF - FINAL (SIGN/PAVEMENT MARKING) 09/16/2021 APPROVED LFITZGERALD
IRRIGATION AFFIDAVIT 09/13/2021 APPROVED - AS NOTED LFITZGERALD
Note: submitted
LDSC-IRRIGATION FINAL 09/13/2021 APPROVED - AS NOTED LFITZGERALD
Note: irrigation affadavit submitted
LDSC- LANDSCAPE / IRRIGATION AS-BUILT 09/13/2021 APPROVED - AS NOTED LFITZGERALD
Note: paper set handed in,working on getting digital set of landscape as-builts submitted As-builts approved under application 4894
LDSC- LANDSCAPE FINAL 09/13/2021 APPROVED LFITZGERALD
UROW - FINAL DRAINAGE 09/02/2021 APPROVED LFITZGERALD
UROW -FINAL GRADE PRIOR SOD 09/02/2021 APPROVED LFITZGERALD
LDSC-PRE-PLANTING TREE QUALITY 09/01/2021 APPROVED - AS NOTED LFITZGERALD
Note: THIS IS A REINSPECTION 3 types of Holly's oaks,bald cypress,magnolia's
LDSC-PRE-PLANTING TREE QUALITY 08/31/2021 PARTIALLY APPROVED LFITZGERALD
Note: oaks,bald cypress,magnolia's
U-WATER METER INSTALLATION/VERIFICATION 08/30/2021 APPROVED - AS NOTED LFITZGERALD
Note: THIS IS A REINSPECTION 1in backflow/meter on west end for unit 1/2nd 1in for unit 2 and 2in for unit 3 spoke with Sheldon when to call this back in
LANDSCAPE PRE-CONSTRUCTION MEETING 07/28/2021 APPROVED - AS NOTED LFITZGERALD
Note: met Tim with TB Outdoors on site
UC-CONSTRUCTION ENTRANCE 07/26/2021 APPROVED - AS NOTED LFITZGERALD
Note: THIS IS A REINSPECTION -now being paved THIS IS A REINSPECTION -slight soil tracking-brooming off at end of day-Sheldon called in to close out this inspection but i explained i leave as a partial since it is an on going maintanence issue just lumbering for now and because of this , asphalt millings used with a berm a 57 to 1in stone being used. spoke with Josh that need to keep eye on and if soils start making their way onto roadway wll have to be more aggressive on the entrance.
UC-MOT MAINTENANCE OF TRAFFIC 07/26/2021 APPROVED LFITZGERALD
UC-ASPHALT PRE PLACEMENT 07/26/2021 APPROVED LFITZGERALD
UROW - FORM BOARD/CONCRETE (NON STRUCTURAL) 07/23/2021 APPROVED - AS NOTED LFITZGERALD
Note: THIS IS A REINSPECTION -2 sections of sidewalk/flume/mes's/fire backflow pad building apron
UROW - FORM BOARD/CONCRETE (NON STRUCTURAL) 07/21/2021 PARTIALLY APPROVED LFITZGERALD
Note: building apron
UROW- CURBING & GUTTER 07/19/2021 APPROVED LFITZGERALD
Note: F curb now being installed
U-WATER METER INSTALLATION/VERIFICATION 07/07/2021 CANCELLED BY APPLICANT LFITZGERALD
Note: spoke with Sheldon when to call this back in
U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR 06/01/2021 APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -screen samples foe all 3 units taken on May 20th and all were absent for total coliforms and E. Coli THIS IS A REINSPECTION -16x6 and 16x2 wet taps completed/water main sections completed to 6in fire backflow and adjacent hydrant/ 2in poly tube connected to 2in corp 16x6 sleeve and 16x2 saddle attached to existing 16in water main with min pressure holding for sleeve
U-WATER SERVICE INSTALLATION 05/19/2021 APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION 2-1in meter/backflow and 2in meter /backflow now installed to 1.5 in poly tubing-plummer to tie in to bldg. at some time THIS IS A REINSPECTION 3 lines of 1.5 in poly now installed from proposed bldg. tie in up to 2in poly curb stop where manifold/meter/backflows will be installed called in by accident
BLD - UNDERGROUND SITE LIGHTING CONDUITS 05/12/2021 APPROVED RMARTIN
Note: THIS IS A REINSPECTION MARKED ON PRINT, POLE LIGHT CONDUITS
UC-DRAINAGE PIPE PLACEMENT/LAMPING 05/07/2021 APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -15in pipe for down spouts now installed THIS IS A REINSPECTION -pipe placed from CS-1 to U end wall and down spout line from MES to corner of the bldg. THIS IS A REINSPECTION -complete to 2 and placed from str.2 to 1 THIS IS A REINSPECTION -pipe from str 4 to mes(pond)/from str 3 heading to str 2 THIS IS A REINSPECTION -pipe from str. 5 to 3 THIS IS A REINSPECTION -called in by Sheldon and i explained that there is more pipe to be installed so i leave as a partial rcp for swale culvert now installed
U-WATER SERVICE INSTALLATION 05/05/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION 3 lines of 1.5 in poly now installed from proposed bldg. tie in up to 2in poly curb stop where manifold/meter/backflows will be installed called in by accident
U - SEWER TIE IN 05/05/2021 APPROVED - AS NOTED LFITZGERALD
Note: covered under sanitary sewer install where the tie in to the existing took place on 4-29-2021
UC-DRAINAGE PIPE PLACEMENT/LAMPING 05/04/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -pipe placed from CS-1 to U end wall and down spout line from MES to corner of the bldg. THIS IS A REINSPECTION -complete to 2 and placed from str.2 to 1 THIS IS A REINSPECTION -pipe from str 4 to mes(pond)/from str 3 heading to str 2 THIS IS A REINSPECTION -pipe from str. 5 to 3 THIS IS A REINSPECTION -called in by Sheldon and i explained that there is more pipe to be installed so i leave as a partial rcp for swale culvert now installed
U-GRAVITY SEWER INSTALL/TESTING 05/04/2021 APPROVED - AS NOTED LFITZGERALD
Note: THIS IS A REINSPECTION remaining sanitary line to bldg. stub outs installed 8x6 wye tie in to existing 8in sanitary completed plus 2 sticks of pipe installed in existing driveway of other bldg.
UC-DRAINAGE STRUCT PLACMNT 04/30/2021 APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -control str (pond) now placed THIS IS A REINSPECTION U wall for pond outfall placed THIS IS A REINSPECTION-str 1 placed THIS IS A REINSPECTION str 2 placed THIS IS A REINSPECTION-str 4 placed 5 and 3 placed
UC-DRAINAGE STRUCT PLACMNT 04/29/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION U wall for pond outfall placed THIS IS A REINSPECTION-str 1 placed THIS IS A REINSPECTION str 2 placed THIS IS A REINSPECTION-str 4 placed 5 and 3 placed
U-GRAVITY SEWER INSTALL/TESTING 04/29/2021 PARTIALLY APPROVED LFITZGERALD
Note: 8x6 wye tie in to existing 8in sanitary completed plus 2 sticks of pipe installed in existing driveway of other bldg.
U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR 04/28/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -16x6 and 16x2 wet taps completed/water main sections completed to 6in fire backflow and adjacent hydrant/ 2in poly tube connected to 2in corp 16x6 sleeve and 16x2 saddle attached to existing 16in water main with min pressure holding for sleeve
UC-DRAINAGE STRUCT PLACMNT 04/28/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION-str 1 placed THIS IS A REINSPECTION str 2 placed THIS IS A REINSPECTION-str 4 placed 5 and 3 placed
UC-DRAINAGE PIPE PLACEMENT/LAMPING 04/28/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -complete to 2 and placed from str.2 to 1 THIS IS A REINSPECTION -pipe from str 4 to mes(pond)/from str 3 heading to str 2 THIS IS A REINSPECTION -pipe from str. 5 to 3 THIS IS A REINSPECTION -called in by Sheldon and i explained that there is more pipe to be installed so i leave as a partial rcp for swale culvert now installed
UC-DRAINAGE STRUCT PLACMNT 04/27/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION str 2 placed THIS IS A REINSPECTION-str 4 placed 5 and 3 placed
U-WATER MAIN INSTALLATION/TESTING/BACKFLOW PREVENTOR 04/27/2021 PARTIALLY APPROVED LFITZGERALD
Note: 16x6 sleeve and 16x2 saddle attached to existing 16in water main with min pressure holding for sleeve
UC-DRAINAGE STRUCT PLACMNT 04/26/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION-str 4 placed 5 and 3 placed
UC-DRAINAGE PIPE PLACEMENT/LAMPING 04/26/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -pipe from str 4 to mes(pond)/from str 3 heading to str 2 THIS IS A REINSPECTION -pipe from str. 5 to 3 THIS IS A REINSPECTION -called in by Sheldon and i explained that there is more pipe to be installed so i leave as a partial rcp for swale culvert now installed
UC-DRAINAGE PIPE PLACEMENT/LAMPING 04/23/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -pipe from str. 5 to 3 THIS IS A REINSPECTION -called in by Sheldon and i explained that there is more pipe to be installed so i leave as a partial rcp for swale culvert now installed
UC-DRAINAGE STRUCT PLACMNT 04/23/2021 PARTIALLY APPROVED LFITZGERALD
Note: 5 and 3 placed
U-WATER SERVICE INSTALLATION 04/21/2021 CANCELLED BY APPLICANT LFITZGERALD
Note: called in by accident
BLD - UNDERGROUND SITE LIGHTING CONDUITS 04/19/2021 PARTIALLY APPROVED RMARTIN
Note: MARKED ON PRINT, POLE LIGHT CONDUITS
UC-DRAINAGE PIPE PLACEMENT/LAMPING 03/30/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -called in by Sheldon and i explained that there is more pipe to be installed so i leave as a partial rcp for swale culvert now installed
UC-CONSTRUCTION ENTRANCE 03/30/2021 PARTIALLY APPROVED LFITZGERALD
Note: THIS IS A REINSPECTION -slight soil tracking-brooming off at end of day-Sheldon called in to close out this inspection but i explained i leave as a partial since it is an on going maintanence issue just lumbering for now and because of this , asphalt millings used with a berm a 57 to 1in stone being used. spoke with Josh that need to keep eye on and if soils start making their way onto roadway wll have to be more aggressive on the entrance.
UC-DRAINAGE PIPE PLACEMENT/LAMPING 02/16/2021 PARTIALLY APPROVED LFITZGERALD
Note: rcp for swale culvert now installed
UC-CONSTRUCTION ENTRANCE 02/16/2021 PARTIALLY APPROVED LFITZGERALD
Note: just lumbering for now and because of this , asphalt millings used with a berm a 57 to 1in stone being used. spoke with Josh that need to keep eye on and if soils start making their way onto roadway wll have to be more aggressive on the entrance.
LDSC-TREE BARRICADE 02/12/2021 APPROVED JHARDING
ROW - EROSION CONTROL / INLET PROTE/SILT FENCE 02/12/2021 APPROVED JHARDING
PLAN - PRE-CON 386-986-3750 01/25/2021 APPROVED LFITZGERALD

Review History

Department Status Date In Date Out
BLD COMPLETE 01/27/2021 01/28/2021
Note: Released By: PBUCKLEY
ELEC COMPLETE 01/27/2021 01/27/2021
Note: Released By: JMUNSON
PLENG COMPLETE 01/27/2021 01/27/2021
Note: Released By: DLEAP
PLLA COMPLETE 01/27/2021 01/28/2021
Note: Released By: DRAMIREZ
UD1 COMPLETE 01/27/2021 01/27/2021
Note: Released By: CJOHNSON

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
BUILDING DISCOUNT 100% (¤125.00) 02/02/2021
INSPECTION 40 ¤400.00 02/02/2021
PERMIT FEE ¤125.00 02/02/2021
SITE INSPECTION ¤760.00 02/02/2021
SITE PLAN 20 ¤20.00 02/02/2021
Fees Total Due: ¤0.00 Total Paid: ¤1,180.00