Permit #2021011042
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7008-00090-0480 |
| CONDITIONED SPACE: 380 sqft |
| CONDITIONED SPACE: 1147 sqft |
| OPENED PORCH (WITH ROOF) : 500 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| Total Square Footage: 2139 sqft |
| Block: 00090 |
| Subdivision: 2204 - SECTION 8-COUNTRY CLUB COVE |
| Job Phone: 386-585-4424 |
| Location Address: 40 COURTNEY PL |
| Type: BA - BUILDING ADDITION |
| Issue Date: 03/04/2021 |
| NOC: RECORDED |
| Applicant name: BRAD MICHAEL THOMAS |
| Owner: KALABOKES STEVEN & JOANNE H&W |
|
Address 40 COURTNEY PL PALM COAST, FL 32137 |
| Lot: 0480 |
| Contracted Stated Job Value: ¤220,000.00 |
| Job Description: Building Addition and Roof Replacement |
| Type: CN |
Contractor
THOMAS CONSULTING AND CONSTRUCTION LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
25 PINE DRIVE PALM COAST, FL 32164 |
STE 3C PALM COAST, FL 32164 |
CGC1506292 (Exp: 08/31/2026) | 386-585-4424 |
Sub Contractors
YORDANIS GONZALEZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
33 RICKENBACKER DRIVE PALM COAST, FL 32164 |
CCC1328730 (Exp: 08/31/2026) | 386-804-4109 |
JOHN ROBERT BLEVINS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
17 PORWYN LANE PALM COAST, FL 32164 |
CAC1816125 (Exp: 08/31/2026) | 386-585-8283 | 386-263-2096 |
GIOVANNI DISARRO
| Status | Location Address | State License Number |
| INACTIVE |
107 BURROUGHS DRIVE PALM COAST, FL 32137 |
CFC1430761 (Exp: 08/31/2026) |
BUD C ROCHELL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3530 AGRICULTURAL CNETER DRIVE #208 , 0 |
EC13004824 (Exp: 08/31/2026) | 904-547-2156 | 904-217-8040 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/03/2022 | FINAL APPROVED | RMARTIN |
| BLD - BUILDING FINAL | 03/02/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 1. Shower water does not work. 2. AHU line set in ceiling is not sealed. 3. AHU not labeled. 4. Energy calculations not on site. 5. Master bedroom fan switch does not work. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/17/2022 | FINAL APPROVED | DHANEY |
| BLD - BUILDING FINAL | 02/17/2022 | CANCELLED BY APPLICANT | WEB |
| FINAL SURVEY (OFFICE USE ONLY) | 02/16/2022 | APPROVED | KRUTH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/16/2022 | APPROVED | KRUTH |
| ROW - FINAL INSPECTION | 02/16/2022 | APPROVED | KRUTH |
| LATH/BRICK/ WATER BARRIER | 09/20/2021 | APPROVED | DCUSHING |
| INSULATION | 09/13/2021 | APPROVED | DCUSHING |
| Note: Will need to provide certificate for blown-in in attic | |||
| ALL ROUGH | 09/10/2021 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 cancelled via phone call 9-3-21... 1. MOUNTING, E3404.8 ELECTRICAL EQUIPMENT SHALL BE FIRMLY SECURED TO THE SURFACE ON WHICH IT IS MOUNTED (Missing boxes) 2. need to add a smoke outside the hallway from master edroom (no door between bedroom and hallway) 3. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER OR SHALL BE PROTECTED BY A LISTED STEEL PLATE 4. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 5. EXAUST NOT PROPERLY TERMINATED 1501.1 AIR SHALL NOT BE EXAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT, OR CRAWL SPACE 6. Need to move wire where they lay against a can light 7. missing attic access and pul chain light in front room per plans. 8, Missing Grommets NEC 300.4 a 1 in bath exaust fans 9. M1305.1.1 Furnaces and air handlers. Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches 10. FIREBLOCKING REQUIRED R302.11 (1-6) (top of furred out wall) ALL ISSUES TAKEN CARE OF - 9.10.21 | |||
| ALL ROUGH | 09/03/2021 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 cancelled via phone call 9-3-21... 1. MOUNTING, E3404.8 ELECTRICAL EQUIPMENT SHALL BE FIRMLY SECURED TO THE SURFACE ON WHICH IT IS MOUNTED (Missing boxes) 2. need to add a smoke outside the hallway from master edroom (no door between bedroom and hallway) 3. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER OR SHALL BE PROTECTED BY A LISTED STEEL PLATE 4. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 5. EXAUST NOT PROPERLY TERMINATED 1501.1 AIR SHALL NOT BE EXAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT, OR CRAWL SPACE 6. Need to move wire where they lay against a can light 7. missing attic access and pul chain light in front room per plans. 8, Missing Grommets NEC 300.4 a 1 in bath exaust fans 9. M1305.1.1 Furnaces and air handlers. Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches 10. FIREBLOCKING REQUIRED R302.11 (1-6) (top of furred out wall) | |||
| ALL ROUGH | 09/02/2021 | CANCELLED BY APPLICANT | WMILLER |
| Note: THIS IS A REINSPECTION NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 cancelled via phone call | |||
| ALL ROUGH | 09/01/2021 | Disapproved -FEE REQUIRED | WMILLER |
| Note: NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 | |||
| ROOF VALLEY & METAL | 06/24/2021 | APPROVED | BGREVE |
| Note: this roof valley metal inspection includes the existing house. all was ready at time of inspection | |||
| GRAVITY SEWER TEST | 06/02/2021 | APPROVED - AS NOTED | JGIBSON |
| Note: SEWER IS APPROVED RAN LIBERTY PUMP AND REQUIRED CHECK VALVES ARE IN PLACE | |||
| ROOF VALLEY & METAL | 05/24/2021 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/20/2021 | APPROVED - AS NOTED | BGREVE |
| Note: complete nailing tie down straps front gable complete installing twist ties at rear addition | |||
| FOUND SURVEY APPROVED (OFFICE) | 04/05/2021 | APPROVED | TDOAK |
| TIE BEAM / LINTEL | 04/05/2021 | APPROVED | BGREVE |
| MONOLITHIC SLAB | 03/25/2021 | APPROVED | BGREVE |
| PLUMBING 1ST ROUGH UNDERGROUND | 03/22/2021 | APPROVED | JGIBSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 08/06/2021 | 08/09/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/05/2021 | 04/05/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US | |||
| ZON | COMPLETE | 04/05/2021 | 04/05/2021 |
| Note: Released By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/03/2021 | 03/03/2021 |
| Note: Released By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/01/2021 | 03/01/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/01/2021 | 03/03/2021 |
| Note: Held By: ESTELLE LENS - (386)986-2655 - The notary did not properly notarize the Single Family Dwelling Affidavit. (They must write in the names of the individual(s) whose signature(s) they are notarizing...not leave it blank.) | |||
| SW1 | COMPLETE | 02/19/2021 | 02/25/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| MECH | HOLD | 02/19/2021 | 02/23/2021 |
| Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs and EPL card need to be signed by the builder | |||
| ELEC | COMPLETE | 02/19/2021 | 02/19/2021 |
| Note: Released By: JOSH MUNSON - (386)341-3640 - | |||
| ZON | HOLD | 02/19/2021 | 02/23/2021 |
| Note: Held By: ESTELLE LENS - (386)986-2655 - Please provide the Original Single Family Dwelling Affidavit for recording. | |||
| PLUM | COMPLETE | 02/19/2021 | 02/26/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us | |||
| BLD | COMPLETE | 02/19/2021 | 02/26/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us | |||
| BLD | HOLD | 01/26/2021 | 01/29/2021 |
| Note: Held By: FREODICA 1. Revise the referenced code from FBC 2017 to 2020 or 7th Edition. 2. Provide the missing items on Product Approval Sheet per FS 553.842 namely: soffits, structural components such as wood anchors, wood connectors, truss plates and lintels. FReodica -386-986-4734 | |||
| ELEC | HOLD | 01/26/2021 | 01/27/2021 |
| Note: Held By: JMUNSON 1.Electric load calcs need to show summer kitchen and the exsisting A/C equipment and the new equipment. 2. Show exsisiting size of service. | |||
| MECH | HOLD | 01/26/2021 | 01/27/2021 |
| Note: Held By: CPISCITELLI Square footage on heatload does not match the plans. Revise to match | |||
| PLUM | HOLD | 01/26/2021 | 01/29/2021 |
| Note: Held By: FREODICA 1. Provide sanitary riser diagram either prepared by design professional or a plumbing contractor with signature and license number indicated on the riser per FBC 7th Edition Sec. 107.2.1. FReodica -386-986-4734 | |||
| SW1 | HOLD | 01/26/2021 | 01/26/2021 |
| Note: Held By: KRUTH refer to the checklist anything that is highlighted needs correction a stormwater informational packet has been attached as well if you are having issues you can look through the packet for info | |||
| ZON | HOLD | 01/26/2021 | 01/27/2021 |
| Note: Held By: ELENS Please provide a Single Family Dwelling Affidavit. (Signed by all owners on the deed and notarized. Original must be submitted to Zoning for recording.) Please provide the setback from the addition to the front property line. The Land Development Code states minimum roof pitch of 5:12 is required on 65% of home. Please demonstrate this requirement is met. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/16/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/16/2022 |
| BUILDING DISCOUNT 100% | (¤1,564.00) | 03/04/2021 |
| ELECTRIC FEE | ¤192.00 | 03/04/2021 |
| RECORDING FEE REIMBURSE DOC | ¤10.00 | 03/04/2021 |
| MECHANICAL FEE | ¤192.00 | 03/04/2021 |
| PLAN CHECK FEE | ¤88.00 | 03/04/2021 |
| PLUMBING FEE | ¤192.00 | 03/04/2021 |
| REMODEL/ADDITION/ACCES INSPECT | ¤880.00 | 03/04/2021 |
| SITE PLAN 20 | ¤20.00 | 03/04/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/04/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/04/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 03/04/2021 |
| ADMIN FEE | ¤20.00 | 03/04/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤194.00 |