Status: FINAL

Parcel Id: 07-11-31-7008-00090-0480
CONDITIONED SPACE: 380 sqft
CONDITIONED SPACE: 1147 sqft
OPENED PORCH (WITH ROOF) : 500 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2139 sqft
Block: 00090
Subdivision: 2204 - SECTION 8-COUNTRY CLUB COVE
Job Phone: 386-585-4424
Location Address: 40 COURTNEY PL
Type: BA - BUILDING ADDITION
Issue Date: 03/04/2021
NOC: RECORDED
Applicant name: BRAD MICHAEL THOMAS
Owner: KALABOKES STEVEN & JOANNE H&W

Address

40 COURTNEY PL

PALM COAST, FL 32137

Lot: 0480
Contracted Stated Job Value: ¤220,000.00
Job Description: Building Addition and Roof Replacement
Type: CN

Contractor

THOMAS CONSULTING AND CONSTRUCTION LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

25 PINE DRIVE

PALM COAST, FL 32164

STE 3C

PALM COAST, FL 32164

CGC1506292 (Exp: 08/31/2026) 386-585-4424

Sub Contractors

YORDANIS GONZALEZ
Status Location Address State License Number Phone
ACTIVE

33 RICKENBACKER DRIVE

PALM COAST, FL 32164

CCC1328730 (Exp: 08/31/2026) 386-804-4109
JOHN ROBERT BLEVINS JR
Status Location Address State License Number Phone Fax
ACTIVE

17 PORWYN LANE

PALM COAST, FL 32164

CAC1816125 (Exp: 08/31/2026) 386-585-8283 386-263-2096
GIOVANNI DISARRO
Status Location Address State License Number
INACTIVE

107 BURROUGHS DRIVE

PALM COAST, FL 32137

CFC1430761 (Exp: 08/31/2026)
BUD C ROCHELL
Status Location Address State License Number Phone Fax
ACTIVE

3530 AGRICULTURAL CNETER DRIVE #208

, 0

EC13004824 (Exp: 08/31/2026) 904-547-2156 904-217-8040

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/03/2022 FINAL APPROVED RMARTIN
BLD - BUILDING FINAL 03/02/2022 Disapproved - NO FEE AGAETANO
Note: 1. Shower water does not work. 2. AHU line set in ceiling is not sealed. 3. AHU not labeled. 4. Energy calculations not on site. 5. Master bedroom fan switch does not work.
U -UTILITY RESIDENTIAL FINAL 02/17/2022 FINAL APPROVED DHANEY
BLD - BUILDING FINAL 02/17/2022 CANCELLED BY APPLICANT WEB
FINAL SURVEY (OFFICE USE ONLY) 02/16/2022 APPROVED KRUTH
ROW FIELD SURVEY /GRADING CERTIFICATION 02/16/2022 APPROVED KRUTH
ROW - FINAL INSPECTION 02/16/2022 APPROVED KRUTH
LATH/BRICK/ WATER BARRIER 09/20/2021 APPROVED DCUSHING
INSULATION 09/13/2021 APPROVED DCUSHING
Note: Will need to provide certificate for blown-in in attic
ALL ROUGH 09/10/2021 APPROVED DCUSHING
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 cancelled via phone call 9-3-21... 1. MOUNTING, E3404.8 ELECTRICAL EQUIPMENT SHALL BE FIRMLY SECURED TO THE SURFACE ON WHICH IT IS MOUNTED (Missing boxes) 2. need to add a smoke outside the hallway from master edroom (no door between bedroom and hallway) 3. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER OR SHALL BE PROTECTED BY A LISTED STEEL PLATE 4. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 5. EXAUST NOT PROPERLY TERMINATED 1501.1 AIR SHALL NOT BE EXAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT, OR CRAWL SPACE 6. Need to move wire where they lay against a can light 7. missing attic access and pul chain light in front room per plans. 8, Missing Grommets NEC 300.4 a 1 in bath exaust fans 9. M1305.1.1 Furnaces and air handlers. Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches 10. FIREBLOCKING REQUIRED R302.11 (1-6) (top of furred out wall) ALL ISSUES TAKEN CARE OF - 9.10.21
ALL ROUGH 09/03/2021 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 cancelled via phone call 9-3-21... 1. MOUNTING, E3404.8 ELECTRICAL EQUIPMENT SHALL BE FIRMLY SECURED TO THE SURFACE ON WHICH IT IS MOUNTED (Missing boxes) 2. need to add a smoke outside the hallway from master edroom (no door between bedroom and hallway) 3. 1 1/4 FROM EDGE, WHERE WIRING IS RUNS ALONG EDGE OF WOOD FBC E3802.1 WIRING SHALL NOT BE LESS THAN 1.25 inches AWAY FROM WOOD MEMBER OR SHALL BE PROTECTED BY A LISTED STEEL PLATE 4. NAIL PLATES ELECTRIC 1 ¼ inches from the face of the member NEC 300.4 a 1 5. EXAUST NOT PROPERLY TERMINATED 1501.1 AIR SHALL NOT BE EXAUSTED INTO AN ATTIC, SOFFIT, RIDGE VENT, OR CRAWL SPACE 6. Need to move wire where they lay against a can light 7. missing attic access and pul chain light in front room per plans. 8, Missing Grommets NEC 300.4 a 1 in bath exaust fans 9. M1305.1.1 Furnaces and air handlers. Furnaces and air handlers within compartments or alcoves shall have a minimum working space clearance of 3 inches 10. FIREBLOCKING REQUIRED R302.11 (1-6) (top of furred out wall)
ALL ROUGH 09/02/2021 CANCELLED BY APPLICANT WMILLER
Note: THIS IS A REINSPECTION NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 cancelled via phone call
ALL ROUGH 09/01/2021 Disapproved -FEE REQUIRED WMILLER
Note: NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1
ROOF VALLEY & METAL 06/24/2021 APPROVED BGREVE
Note: this roof valley metal inspection includes the existing house. all was ready at time of inspection
GRAVITY SEWER TEST 06/02/2021 APPROVED - AS NOTED JGIBSON
Note: SEWER IS APPROVED RAN LIBERTY PUMP AND REQUIRED CHECK VALVES ARE IN PLACE
ROOF VALLEY & METAL 05/24/2021 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/20/2021 APPROVED - AS NOTED BGREVE
Note: complete nailing tie down straps front gable complete installing twist ties at rear addition
FOUND SURVEY APPROVED (OFFICE) 04/05/2021 APPROVED TDOAK
TIE BEAM / LINTEL 04/05/2021 APPROVED BGREVE
MONOLITHIC SLAB 03/25/2021 APPROVED BGREVE
PLUMBING 1ST ROUGH UNDERGROUND 03/22/2021 APPROVED JGIBSON

Review History

Department Status Date In Date Out
BLD COMPLETE 08/06/2021 08/09/2021
Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/05/2021 04/05/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US
ZON COMPLETE 04/05/2021 04/05/2021
Note: Released By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 03/03/2021 03/03/2021
Note: Released By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 03/01/2021 03/01/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 03/01/2021 03/03/2021
Note: Held By: ESTELLE LENS - (386)986-2655 - The notary did not properly notarize the Single Family Dwelling Affidavit. (They must write in the names of the individual(s) whose signature(s) they are notarizing...not leave it blank.)
SW1 COMPLETE 02/19/2021 02/25/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
MECH HOLD 02/19/2021 02/23/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs and EPL card need to be signed by the builder
ELEC COMPLETE 02/19/2021 02/19/2021
Note: Released By: JOSH MUNSON - (386)341-3640 -
ZON HOLD 02/19/2021 02/23/2021
Note: Held By: ESTELLE LENS - (386)986-2655 - Please provide the Original Single Family Dwelling Affidavit for recording.
PLUM COMPLETE 02/19/2021 02/26/2021
Note: Released By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us
BLD COMPLETE 02/19/2021 02/26/2021
Note: Released By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us
BLD HOLD 01/26/2021 01/29/2021
Note: Held By: FREODICA 1. Revise the referenced code from FBC 2017 to 2020 or 7th Edition. 2. Provide the missing items on Product Approval Sheet per FS 553.842 namely: soffits, structural components such as wood anchors, wood connectors, truss plates and lintels. FReodica -386-986-4734
ELEC HOLD 01/26/2021 01/27/2021
Note: Held By: JMUNSON 1.Electric load calcs need to show summer kitchen and the exsisting A/C equipment and the new equipment. 2. Show exsisiting size of service.
MECH HOLD 01/26/2021 01/27/2021
Note: Held By: CPISCITELLI Square footage on heatload does not match the plans. Revise to match
PLUM HOLD 01/26/2021 01/29/2021
Note: Held By: FREODICA 1. Provide sanitary riser diagram either prepared by design professional or a plumbing contractor with signature and license number indicated on the riser per FBC 7th Edition Sec. 107.2.1. FReodica -386-986-4734
SW1 HOLD 01/26/2021 01/26/2021
Note: Held By: KRUTH refer to the checklist anything that is highlighted needs correction a stormwater informational packet has been attached as well if you are having issues you can look through the packet for info
ZON HOLD 01/26/2021 01/27/2021
Note: Held By: ELENS Please provide a Single Family Dwelling Affidavit. (Signed by all owners on the deed and notarized. Original must be submitted to Zoning for recording.) Please provide the setback from the addition to the front property line. The Land Development Code states minimum roof pitch of 5:12 is required on 65% of home. Please demonstrate this requirement is met.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/16/2022
REINSPECTION RESIDENTIAL ¤40.00 02/16/2022
BUILDING DISCOUNT 100% (¤1,564.00) 03/04/2021
ELECTRIC FEE ¤192.00 03/04/2021
RECORDING FEE REIMBURSE DOC ¤10.00 03/04/2021
MECHANICAL FEE ¤192.00 03/04/2021
PLAN CHECK FEE ¤88.00 03/04/2021
PLUMBING FEE ¤192.00 03/04/2021
REMODEL/ADDITION/ACCES INSPECT ¤880.00 03/04/2021
SITE PLAN 20 ¤20.00 03/04/2021
SURCHARGE FS 533.721 ¤2.00 03/04/2021
SURCHARGE - FS 468.631 ¤2.00 03/04/2021
STORM WATER PERMIT FEES ¤80.00 03/04/2021
ADMIN FEE ¤20.00 03/04/2021
Fees Total Due: ¤0.00 Total Paid: ¤194.00