Permit #2021021022

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-00560-0080
CONDITIONED SPACE: 1707 sqft
OPENED PORCH (WITH ROOF) : 235 sqft
GARAGE: 592 sqft
OPENED PORCH (WITH ROOF) : 42 sqft
Total Square Footage: 2576 sqft
Block: 00560
Subdivision: 2172 - SECTION 35-BELLE TERRE
Job Phone: (386) 445-7001
Location Address: 18 BURBANK DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/03/2021
NOC: RECORDED
Applicant name: RICHARD M. ANDERSON
Owner: ANDERSON REALTY FLORIDA LP

Address

8 CARLOS COURT

PALM COAST, FL 32137

Address

% LEWERS & ASSOCIATES

PALM COAST, FL 32137

Lot: 0080
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

PALM WEST HOME BUILDERS, INC.
Status Location Address State License Number Phone Fax
ACTIVE

2 Florida Park Drive North

Palm Coast, FL 32137

CRC054633 (Exp: 08/31/2026) (386) 445-7001 (386)446-5941

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488
CHRISTOPHER DANIEL FULTON
Status Location Address Mailing Address State License Number Phone
ACTIVE

2 MARKET PLACE

PALM COAST, FL 32137

UNIT D

PALM COAST, FL 32137

CCC1331939 (Exp: 08/31/2026) 386-445-7945

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/14/2022 FINAL APPROVED MKRASKI
Note:
ROW - STORMWATER FINAL 10/14/2022 FINAL APPROVED EMADISON
Note: ** 10/14/22 ALL CORRECTIONS MADE 10/12/2022 - PREVIOUS INSPECTION NOTES ** 10/12/22 LEFT FRONT CONER OF HOUSE NEED TO FILL HOLE AND SOD AS YOU HAVE A WASHOUT ** CULVERT ENDS NEED TO BE CLEANED OF SEDIMENT AND OVER POUR OF CONCRETE ** BEFORE FINAL ROW IS APPROVED ** 08/23/22 REAR OF HOUSE IS TOO LOW HOLDING WATER WHICH IS PONDING NEEDS TO HAVE A POSITIVE FLOW TO THE FRONT. ** RIGHT SIDE THERE APPEARS TO BE A LEAK IN THE IRRIGATION AS THERE IS A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** LEFT SIDE AT FRONT CORNER OF HOUSE ALSI APPEARS TO BE AN IRRIGATION LEAK CFREATING A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** CLEAN OUT CULVERT ENDS
U -UTILITY RESIDENTIAL FINAL 10/12/2022 FINAL APPROVED DHANEY
ROW - STORMWATER FINAL 10/12/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 10/12/22 LEFT FRONT CONER OF HOUSE NEED TO FILL HOLE AND SOD AS YOU HAVE A WASHOUT ** CULVERT ENDS NEED TO BE CLEANED OF SEDIMENT AND OVER POUR OF CONCRETE ** BEFORE FINAL ROW IS APPROVED ** 08/23/22 REAR OF HOUSE IS TOO LOW HOLDING WATER WHICH IS PONDING NEEDS TO HAVE A POSITIVE FLOW TO THE FRONT. ** RIGHT SIDE THERE APPEARS TO BE A LEAK IN THE IRRIGATION AS THERE IS A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** LEFT SIDE AT FRONT CORNER OF HOUSE ALSI APPEARS TO BE AN IRRIGATION LEAK CFREATING A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** CLEAN OUT CULVERT ENDS
ROW - FINAL APRON (AFTER POUR) 10/12/2022 APPROVED EMADISON
Note: Inspector Notes from Inspection 9465 ** 08/23/22 REAR OF HOUSE IS TOO LOW HOLDING WATER WHICH IS PONDING NEEDS TO HAVE A POSITIVE FLOW TO THE FRONT. ** RIGHT SIDE THERE APPEARS TO BE A LEAK IN THE IRRIGATION AS THERE IS A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** LEFT SIDE AT FRONT CORNER OF HOUSE ALSI APPEARS TO BE AN IRRIGATION LEAK CFREATING A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** CLEAN OUT CULVERT ENDS
BLD - BUILDING FINAL 10/12/2022 Disapproved - NO FEE MKRASKI
Note: 1. Breaker lock required for AHU 2. Hole in drywall above door bell transformer 3. No energy cals on site 4. Porch light not working (back) 5. Side door to the garage light not working 5. Termite treatment sticker missing on electrical panel
U-CROSS CONNECTION 10/12/2022 APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/23/2022 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 08/23/2022 APPROVED - AS NOTED EMADISON
Note: ** 08/23/22 REAR OF HOUSE IS TOO LOW HOLDING WATER WHICH IS PONDING NEEDS TO HAVE A POSITIVE FLOW TO THE FRONT. ** RIGHT SIDE THERE APPEARS TO BE A LEAK IN THE IRRIGATION AS THERE IS A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** LEFT SIDE AT FRONT CORNER OF HOUSE ALSI APPEARS TO BE AN IRRIGATION LEAK CFREATING A HOLE IN THE DRAINAGE CONVEYANCE FROM EROSION ** CLEAN OUT CULVERT ENDS
ROW- PRE-APRON (PRE-POUR) 06/29/2022 APPROVED RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION ** APRON IS READY TO POUR PARTIAL APPROVAL, NEED TO SCHEDULE ANOTHER PRE-POUR ONCE PAVER BASE IS DOWN AND COMPACTED PRIOR TO SETTING PAVERS. EM NEED MORE COMPACTION AROUND CULVERT PIPE NEED TO RESUBMIT A NEW SITE PLAN THAT SHOWS THAT YOU ARE PUTTING IN A PAVER DRIVEWAY THE SITE PLAN THATS IN THE SYSTEM SHOWS THAT YOU ARE PUTTING IN A 16' CONCRETE DRIVEWAY THE PIPE IS GOOD AND THE PAVER RESTRAINTS ARE GOOD ALSO NEED MORE COMPACTION AND NEW SITE PLAN BEFORE YOU PUT THIS INSPECTION BACK ON
ROW- PRE-APRON (PRE-POUR) 06/27/2022 PARTIALLY APPROVED EMADISON
Note: THIS IS A REINSPECTION ** APRON IS READY TO POUR PARTIAL APPROVAL, NEED TO SCHEDULE ANOTHER PRE-POUR ONCE PAVER BASE IS DOWN AND COMPACTED PRIOR TO SETTING PAVERS. EM NEED MORE COMPACTION AROUND CULVERT PIPE NEED TO RESUBMIT A NEW SITE PLAN THAT SHOWS THAT YOU ARE PUTTING IN A PAVER DRIVEWAY THE SITE PLAN THATS IN THE SYSTEM SHOWS THAT YOU ARE PUTTING IN A 16' CONCRETE DRIVEWAY THE PIPE IS GOOD AND THE PAVER RESTRAINTS ARE GOOD ALSO NEED MORE COMPACTION AND NEW SITE PLAN BEFORE YOU PUT THIS INSPECTION BACK ON
ROW- PAVER RESTRAINTS 06/27/2022 APPROVED - AS NOTED EMADISON
Note: THIS IS A REINSPECTION ** PAVER RESTRAINTS READY TO POUR.
ROW- PAVER RESTRAINTS 06/15/2022 Disapproved - NO FEE PFLANAGAN
Note: NEED TO RESUBMIT A NEW SITE PLAN THAT SHOWS THAT YOU ARE PUTTING IN A PAVER DRIVEWAY THE SITE PLAN THATS IN THE SYSTEM SHOWS THAT YOU ARE PUTTING IN A 16' CONCRETE DRIVEWAY
ROW- PRE-APRON (PRE-POUR) 06/15/2022 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED MORE COMPACTION AROUND CULVERT PIPE NEED TO RESUBMIT A NEW SITE PLAN THAT SHOWS THAT YOU ARE PUTTING IN A PAVER DRIVEWAY THE SITE PLAN THATS IN THE SYSTEM SHOWS THAT YOU ARE PUTTING IN A 16' CONCRETE DRIVEWAY THE PIPE IS GOOD AND THE PAVER RESTRAINTS ARE GOOD ALSO NEED MORE COMPACTION AND NEW SITE PLAN BEFORE YOU PUT THIS INSPECTION BACK ON
ELECTRIC - EARLY POWER 05/31/2022 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 9:20 AM
ELECTRIC-TUG 05/31/2022 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 9:20 AM
GRAVITY SEWER TEST 04/05/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION SPOKE TO RICHIE
U - SEWER TIE IN 04/05/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION SPOKE TO RICHIE
U - SEWER TIE IN 04/04/2022 CANCELLED BY APPLICANT MGIBSON
Note: SPOKE TO RICHIE
GRAVITY SEWER TEST 04/04/2022 CANCELLED BY APPLICANT MGIBSON
Note: SPOKE TO RICHIE
PEP TANK INSTALLATION REQUEST 03/15/2022 APPROVED CSTONE
LATH/BRICK/ WATER BARRIER 10/22/2021 APPROVED FWILLIS
INSULATION 10/05/2021 APPROVED FWILLIS
ALL ROUGH 09/07/2021 APPROVED - AS NOTED KSANDOE
Note: Missing door to back porch must be installed prior to insulation inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/27/2021 APPROVED RMARTIN
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Please povide a full set of approved drawings and Truss engineering packet for this inspection. Engineering packet not in job box or in the building. FBC 107.3.1 8/3/21 - ROOF SHEATHING ONLY!! ALSO LOOKED AT SCREWS ON SGD SO A WALL CAN BE FRAMED. SLAB THAT WAS REVISED, IN KITCHEN AREA, HAD TERMITE TREATMENT AND WAS GOOD.
ROOF VALLEY & METAL 08/16/2021 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/03/2021 PARTIALLY APPROVED FWILLIS
Note: THIS IS A REINSPECTION Please povide a full set of approved drawings and Truss engineering packet for this inspection. Engineering packet not in job box or in the building. FBC 107.3.1 8/3/21 - ROOF SHEATHING ONLY!! ALSO LOOKED AT SCREWS ON SGD SO A WALL CAN BE FRAMED. SLAB THAT WAS REVISED, IN KITCHEN AREA, HAD TERMITE TREATMENT AND WAS GOOD.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/02/2021 Disapproved - NO FEE JWALKER
Note: Please povide a full set of approved drawings and Truss engineering packet for this inspection. Engineering packet not in job box or in the building. FBC 107.3.1
FOUND SURVEY APPROVED (OFFICE) 07/30/2021 APPROVED TBAKER
TIE BEAM / LINTEL 06/10/2021 APPROVED FWILLIS
MONOLITHIC SLAB 04/23/2021 APPROVED JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 04/16/2021 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 04/12/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
ZON COMPLETE 06/17/2022 06/17/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/16/2022 06/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/16/2022 06/23/2022
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ZON HOLD 06/16/2022 06/16/2022
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM When installing a paver driveway, a fully completed, signed and notarized Right of Way Utilization Agreement must be submitted. It must be signed by all persons on deed to property and all owners signatures must be notarized.
BLD COMPLETE 07/15/2021 07/22/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
BLD HOLD 07/01/2021 07/12/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Provide detail/section showing how the load path from kitchen load bearing foundation to the trusses will be accomplished per FBCR 7th Ed. Sec. 301.1.
BLD COMPLETE 06/02/2021 06/08/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/28/2021 04/28/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/28/2021 04/28/2021
Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 03/02/2021 03/02/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 03/02/2021 03/02/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 02/24/2021 02/24/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
SWALE COMPLETE 02/19/2021 05/11/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/18/2021 02/19/2021
Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 02/18/2021 02/25/2021
Note: Released By: JPI
CUSVC COMPLETE 02/18/2021 02/19/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 02/18/2021 02/19/2021
Note: Held By: JOSH MUNSON - (386)341-3640 - 1. Need to reference the 2017 NEC not the 2020 2. Electric load calcs do not match the square footage of the house. Need to be done to the living space. NEC 2017 220 3. Smoke alarms outside of bedrooms need to be a combo alarm. FRC 2020 314.3 & 315.1
ENGIN1 COMPLETE 02/18/2021 02/19/2021
Note: Released By: TIM BAKER - - TBAKER@CI.PALM-COAST.FL.US
LOCATE COMPLETE 02/18/2021 02/19/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 02/18/2021 02/19/2021
Note: Held By: CHRIS PISCITELLI - (386)597-9959 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be from the 2020 7Th edition code cycle
PLUM COMPLETE 02/18/2021 02/25/2021
Note: Released By: JPI

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
10/14/2022
CONTRACTOR CHANGE ¤40.00 10/14/2022
RECORDING FEE REIMBURSE DOC ¤44.00 10/14/2022
RECORDING FEE REIMBURSE DOC ¤68.50 10/14/2022
SW ENG REINSPECTION 20 ¤20.00 10/14/2022
SW ENG REINSPECTION 30 ¤30.00 10/14/2022
STORM WATER PERMIT FEES ¤80.00 03/03/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 03/03/2021
SEWER CREDIT (¤850.00) 03/03/2021
SEWER INSPECTION ¤25.00 03/03/2021
SEWER CAPITAL FACILITY ¤4,664.55 03/03/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 03/03/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 03/03/2021
MECHANICAL FEE ¤210.00 03/03/2021
WATER -IRRIGATION INSPECTION ¤25.00 03/03/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 03/03/2021
PLAN CHECK FEE ¤100.00 03/03/2021
PLUMBING FEE ¤210.00 03/03/2021
NEW RESIDENTIAL INSPECTIONS ¤500.00 03/03/2021
SITE PLAN 20 ¤20.00 03/03/2021
SURCHARGE FS 533.721 ¤2.00 03/03/2021
SURCHARGE - FS 468.631 ¤2.00 03/03/2021
BUILDING DISCOUNT 100% (¤1,250.00) 03/03/2021
ELECTRIC FEE ¤210.00 03/03/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 03/03/2021
IMPACT FEE FIRE ¤367.00 03/03/2021
IMPACT FEE PARKS ¤1,199.12 03/03/2021
IMPACT FEE SCHOOL ¤3,600.00 03/03/2021
METER - DEPOSIT ¤60.00 03/03/2021
WATER- TURN ON ¤25.00 03/03/2021
ADMIN FEE ¤20.00 03/03/2021
CONNECTION FEES ¤1,017.83 03/03/2021
Fees Total Due: ¤0.00 Total Paid: ¤15,483.93