I want to search for...

Permit #2021021182

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00210-0130
CONDITIONED SPACE: 3330 sqft
GARAGE: 474 sqft
OPENED PORCH (WITH ROOF) : 440 sqft
OPENED PORCH (WITH ROOF) : 158 sqft
Total Square Footage: 4402 sqft
Block: 00210
Subdivision: 2199 - SECTION 28-WYNNFIELD
Job Phone: 386-931-1725
Location Address: 4 POTOMAC DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/02/2021
NOC: RECORDED
Applicant name: JOSEPH ALEIXO PORTAL
Owner: SHEEHAN JAMES P JR

Address

4 POTOMAC

PALM COAST, FL 32164

Lot: 0130
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SWEETWATER CUSTOM HOMES INC.
Status Location Address State License Number Phone Fax
INACTIVE

1105 LAMBERT AVENUE

FLAGLER BEACH, FL 32136

CBC1252965 (Exp: 08/31/2024) 386-931-1725 386-439-4676

Sub Contractors

CHARLES K DAVIS
Status Location Address State License Number Phone
ACTIVE

3000 E MOODY BLVD BLDG 2

BUNNELL , FL 32110

EC13004270 (Exp: 08/31/2026) 386-931-6614
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
SCOTT H STILLWELL
Status Location Address State License Number Phone
ACTIVE

4500 US 1 UNIT 206

BUNNELL, FL 32110

CAC1819433 (Exp: 08/31/2026) 386-864-4404
JOSE E ORTIZ JR
Status Location Address Mailing Address State License Number Phone
CANCEL

4601 E MOODY BLVD

BUNNELL, FL 32110

SUITE B7

BUNNELL, FL 32110

RC29027619 (Exp: 08/31/2023) 386-503-6922

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/31/2022 FINAL APPROVED DCUSHING
Note: Inspector Notes from Inspection 2340 THIS IS A REINSPECTION THIS IS A REINSPECTION Rear of building bathroom exterior door right side missing dowel. Rear columns left column missing 1 Down rod. center column missing 1 down rod. Front of building right column down rod not wire tied to dowel Right side of entry precast lintel 5' missing rebar. Front precast lintel at the 9'8" area at entry the lintel has a busted cracked end left side facing doorway It will need to be replaced. The Garage door lintel page 6/7 typ garage dr. Structure detail calls for 2#5 reif. bars. Only 1 is installed. 7/22/21 Front precast lintel at front entry need to be replaced due to structural damage or have the engineer subbit a worksheet stating the lintel is structually fit for what it will be supporting. All other items pass inspection. 8/30/22 spoke to ray tajmer he emailed me letter for the lintel, not an issue with small crack
U-CROSS CONNECTION 08/31/2022 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with PVB installed(has irrigation meter yet to be connected to irrigation)-no cross connection
ROW - FINAL APRON (AFTER POUR) 08/31/2022 APPROVED GBERTOLA
Note: CORRECTION WERE MADE
U -UTILITY RESIDENTIAL FINAL 08/31/2022 FINAL APPROVED LFITZGERALD
TIE BEAM / LINTEL 08/30/2022 APPROVED - AS NOTED RMARTIN
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Rear of building bathroom exterior door right side missing dowel. Rear columns left column missing 1 Down rod. center column missing 1 down rod. Front of building right column down rod not wire tied to dowel Right side of entry precast lintel 5' missing rebar. Front precast lintel at the 9'8" area at entry the lintel has a busted cracked end left side facing doorway It will need to be replaced. The Garage door lintel page 6/7 typ garage dr. Structure detail calls for 2#5 reif. bars. Only 1 is installed. 7/22/21 Front precast lintel at front entry need to be replaced due to structural damage or have the engineer subbit a worksheet stating the lintel is structually fit for what it will be supporting. All other items pass inspection. 8/30/22 spoke to ray tajmer he emailed me letter for the lintel, not an issue with small crack
ROW - STORMWATER FINAL 08/23/2022 FINAL APPROVED PFLANAGAN
Note: THIS IS A REINSPECTION . Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/22/2022 APPROVED GBERTOLA
Note: 08/22/22=CORRECTION WERE MADE The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. CHECK IN THE FINAL SURVEY -NOTES
ROW FIELD SURVEY /GRADING CERTIFICATION 08/22/2022 APPROVED GBERTOLA
ROW - STORMWATER FINAL 08/22/2022 Disapproved - NO FEE GBERTOLA
Note: . Bare earth on the site or surrounding properties must be sodded, or seeded with pine straw cover, to prevent soil erosion
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/12/2022 Disapproved - NO FEE GBERTOLA
Note: The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. CHECK IN THE FINAL SURVEY -NOTES
ELECTRIC - EARLY POWER 05/17/2022 Disapproved -FEE REQUIRED KSANDOE
Note: THIS IS A REINSPECTION 4/0 aluminum is not rated for 300 amp service NEC 310.15(B)(16) House is locked. Need access for inspection
ELECTRIC - EARLY POWER 05/17/2022 APPROVED - AS NOTED KSANDOE
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 4/0 aluminum is not rated for 300 amp service NEC 310.15(B)(16) House is locked. Need access for inspection Emailed FPL @1207. Release Power
ELECTRIC - EARLY POWER 05/10/2022 Disapproved - NO FEE MKRASKI
Note: 4/0 aluminum is not rated for 300 amp service NEC 310.15(B)(16)
ROW- PRE-APRON (PRE-POUR) 05/06/2022 APPROVED - AS NOTED GBERTOLA
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING.
U - SEWER TIE IN 02/23/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 02/23/2022 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 02/15/2022 APPROVED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 2/11/2022 11:28:49 AM THIS IS A REINSPECTION ADDED ON 1/12/2022 3:15:00 PM swimming pool Pool & Large dirt piles on location of tank email rhand@palmcoastgov.com with questions
PEP TANK INSTALLATION REQUEST 02/11/2022 Disapproved -FEE REQUIRED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 1/12/2022 3:15:00 PM swimming pool Pool & Large dirt piles on location of tank email rhand@palmcoastgov.com with questions
PEP TANK INSTALLATION REQUEST 01/12/2022 Disapproved - NO FEE CSTONE
Note: swimming pool
LATH/BRICK/ WATER BARRIER 12/20/2021 APPROVED KSANDOE
INSULATION 11/29/2021 APPROVED KSANDOE
ALL ROUGH 11/19/2021 APPROVED - AS NOTED KSANDOE
Note: Multiple HVAC flex hoses not strapped, laying in webbing. Heat source exhaust vents not sealed at roof sheathing. Missing trus starp in rear. Contractor onsite made aware.
ROOF VALLEY & METAL 10/26/2021 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/26/2021 APPROVED - AS NOTED JWALKER
Note: THIS IS A REINSPECTION The bearing wall interior and garage call for 1/2" threaded rods at 8' o.c. with a rod coupler. No rods have been installed. Install 1/2" rods as required by detail 2/F and 4F. Multiple trusses are missing engineering. Truss A2 (2) trusses. A3 (5) trusses. A4, A5, A6, A7, A13, 14,15, 16,17,18, F1 through F6 are missing engineering. All are marked on engineering packet. Piggy back trusses Install missing strap hold downs and nail straps missing or not nailed. Gable truss T2GE missing Hold down anchors at 4' o.c. Install 2x4 blocking missing at garage gable Install simpson L3 anchors at all gable cross bracing Down cell at right side of garage is not filled with mortar. knock out a hole at center and top of block to ensure proper fill. 8/26/21 The bearing wall interior and garage call for 1/2" threaded rods at 8' o.c. with a rod coupler. No rods have been installed. Install 1/2" rods as required by detail 2/F and 4F. Have rods installed before All Rough inspection Or submitt a engineers worksheet for anchors and framing installed Straps at front gable truss TG2E still need to be installed
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/17/2021 Disapproved -FEE REQUIRED JWALKER
Note: The bearing wall interior and garage call for 1/2" threaded rods at 8' o.c. with a rod coupler. No rods have been installed. Install 1/2" rods as required by detail 2/F and 4F. Multiple trusses are missing engineering. Truss A2 (2) trusses. A3 (5) trusses. A4, A5, A6, A7, A13, 14,15, 16,17,18, F1 through F6 are missing engineering. All are marked on engineering packet. Piggy back trusses Install missing strap hold downs and nail straps missing or not nailed. Gable truss T2GE missing Hold down anchors at 4' o.c. Install 2x4 blocking missing at garage gable Install simpson L3 anchors at all gable cross bracing Down cell at right side of garage is not filled with mortar. knock out a hole at center and top of block to ensure proper fill.
TIE BEAM / LINTEL 07/22/2021 PARTIALLY APPROVED JWALKER
Note: THIS IS A REINSPECTION Rear of building bathroom exterior door right side missing dowel. Rear columns left column missing 1 Down rod. center column missing 1 down rod. Front of building right column down rod not wire tied to dowel Right side of entry precast lintel 5' missing rebar. Front precast lintel at the 9'8" area at entry the lintel has a busted cracked end left side facing doorway It will need to be replaced. The Garage door lintel page 6/7 typ garage dr. Structure detail calls for 2#5 reif. bars. Only 1 is installed. 7/22/21 Front precast lintel at front entry need to be replaced due to structural damage or have the engineer subbit a worksheet stating the lintel is structually fit for what it will be supporting. All other items pass inspection.
FOUND SURVEY APPROVED (OFFICE) 07/20/2021 APPROVED TBAKER
TIE BEAM / LINTEL 07/19/2021 Disapproved - NO FEE JWALKER
Note: Rear of building bathroom exterior door right side missing dowel. Rear columns left column missing 1 Down rod. center column missing 1 down rod. Front of building right column down rod not wire tied to dowel Right side of entry precast lintel 5' missing rebar. Front precast lintel at the 9'8" area at entry the lintel has a busted cracked end left side facing doorway It will need to be replaced. The Garage door lintel page 6/7 typ garage dr. Structure detail calls for 2#5 reif. bars. Only 1 is installed. Marked the areas on the print.
MONOLITHIC SLAB 06/11/2021 APPROVED JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 05/27/2021 APPROVED JGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 05/26/2021 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 05/25/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 05/31/2022 06/01/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 03/23/2022 03/23/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/23/2022 03/29/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 03/23/2022 03/28/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/18/2022 03/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 03/18/2022 03/23/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 03/18/2022 03/18/2022
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM The circular (non-standard driveway) cannot exceed 18' at its widest point. The area to the right of the standard driveway - the part that directly leads to the garage - appears to exceed 18' in width. Please revise to meet LDC standards.
ENGIN1 COMPLETE 02/02/2022 02/02/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 02/02/2022 02/07/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 02/02/2022 02/02/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC HOLD 11/17/2021 11/17/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Revison sheet says updated electric plan but no plan submitted
ELEC COMPLETE 11/17/2021 11/17/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/25/2021 10/25/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH COMPLETE 10/25/2021 10/25/2021
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 10/22/2021 10/22/2021
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the Ac contractor
BADMIN HOLD 10/20/2021 10/20/2021
Note: Held By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM you need to put the contractor license and let us know your change this contractor to the new contractor on the revision . Then we can make the other one inactive
BADMIN COMPLETE 10/20/2021 10/20/2021
Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM
BLD HOLD 08/31/2021 09/02/2021
Note: Held By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM REVIEW COMMENTS: 1. Simpson SP1 is called for a truss to top plate connector. Per Simpson, this connector is or top plate to stud connection. Provide a connector for truss top plate connection. 2. Submitted plans show a truss to be altered. Provide engineering from the truss manufacture for the altering of the proposed truss.
BLD COMPLETE 08/02/2021 08/02/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Revised plan sheets were submitted in person and containe engineer of record's physical (embossed) seal along with signature. Permit hold released.
BLD HOLD 07/28/2021 08/02/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Provide revised plans with verifiable, digital signature and seal of engineer of record and identifying the latest revision to coordinate with revision description per F.S. 471.025 and F.A.C. 61G15-23.005.
ENGIN1 COMPLETE 07/19/2021 07/20/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/19/2021 07/19/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 03/30/2021 03/30/2021
Note: Released By: JPI
ZON COMPLETE 03/30/2021 03/31/2021
Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 03/30/2021 03/30/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 03/29/2021 03/29/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM No new landscape plan submitted. Layout on landscape does not match site plan Additional tree required for this lot size
SW1 COMPLETE 03/29/2021 03/29/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
ELEC HOLD 03/22/2021 03/22/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Still missing smoke alarm outside of front bedroom. FRC 2020 314.3, 315.1
ZON HOLD 03/22/2021 03/23/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Please turn in the original Single family dwelling affidavit so we can send for recording No new landscape plan submitted. Layout on landscape does not match site plan Additional tree required for this lot size
BLD HOLD 03/22/2021 03/25/2021
Note: Held By: JPI 1. Provide product approval number for mullions. 2. Shingles and Soffit has not been approved for 2020 Code cycle.
PLUM COMPLETE 03/22/2021 03/25/2021
Note: Released By: JPI
ENGIN1 COMPLETE 03/22/2021 03/22/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US
SWALE COMPLETE 02/23/2021 05/13/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 02/22/2021 03/01/2021
Note: Held By: JPI 1. Per Table R803.2.1, nailing pattern for Exposure C should be no less than 6” at edges and in the field. 2. Provide location and size of attic access. 3. Provide roof venting calculations. 4. Please clarify what will be built at the current time for the exterior fireplace. Plans provide details for construction. Floor plan states future. 5. Provide construction details for roof at side bathroom door as illustrated on side and rear elevation. 6. Provide product approval number for mullions. 7. Shingles and Soffit has not been approved for 2020 Code cycle. 8. Provide garage/dwelling separation note.
CUSVC COMPLETE 02/22/2021 02/26/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 02/22/2021 02/23/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need smoke alarms outside of all bedrooms. FRC 2020 314.3 , 315.1
ENGIN1 COMPLETE 02/22/2021 02/23/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US
LOCATE COMPLETE 02/22/2021 03/01/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 02/22/2021 02/23/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
PLUM HOLD 02/22/2021 03/01/2021
Note: 1. DWV isometric does not illustrate rough in of future laundry in garage. 2. DWV isometric does not illustrate shower in bath that leads to exterior on LHS. 3. DWV isometric does not illustrate drain for stacked washer and dryer in bath in separate unit.
SW1 COMPLETE 02/22/2021 02/25/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 02/22/2021 02/25/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM This is in a single family zoning district. A single family residence can only have one kitchen. Please relable plans Please provide a Single family dwelling affidavit signed by all owners on the deed. Once signed the original will need to be turned in to us for recording Walkway layout on plans and landscape plan do not match layout on site plan/survey. They must all match. Please provide the setback from the walkways to property line on site plan Driveway turnarounds can only be 8ft wide by 17ft long. Please show setbacks from driveway turnaround to property lines on site plan Additional tree required for this lot size

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 09/01/2022
CONTRACTOR CHANGE ¤40.00 09/01/2022
CONTRACTOR CHANGE ¤40.00 09/01/2022
CORRECTIONS ¤40.00 09/01/2022
PLAN REVIEW - REVISION ¤32.50 09/01/2022
PLAN REVIEW - REVISION ¤32.50 09/01/2022
REINSPECTION RESIDENTIAL ¤40.00 09/01/2022
REINSPECTION RESIDENTIAL ¤40.00 09/01/2022
UTILITY PEP REINSPECTION ¤40.00 09/01/2022
SEWER INSPECTION ¤25.00 04/02/2021
SEWER CAPITAL FACILITY ¤4,664.55 04/02/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 04/02/2021
CONNECTION FEES ¤1,017.83 04/02/2021
METER - DEPOSIT ¤60.00 04/02/2021
WATER- TURN ON ¤25.00 04/02/2021
ADMIN FEE ¤20.00 04/02/2021
BUILDING DISCOUNT 100% (¤1,934.60) 04/02/2021
ELECTRIC FEE ¤307.80 04/02/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 04/02/2021
IMPACT FEE FIRE ¤367.00 04/02/2021
IMPACT FEE PARKS ¤1,199.12 04/02/2021
IMPACT FEE SCHOOL ¤3,600.00 04/02/2021
RECORDING FEE REIMBURSE DOC ¤10.00 04/02/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 04/02/2021
MECHANICAL FEE ¤307.80 04/02/2021
WATER -IRRIGATION INSPECTION (¤650.00) 04/02/2021
WATER -IRRIGATION INSPECTION ¤25.00 04/02/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 04/02/2021
PLAN CHECK FEE ¤165.20 04/02/2021
PLUMBING FEE ¤307.80 04/02/2021
NEW RESIDENTIAL INSPECTIONS ¤826.00 04/02/2021
SITE PLAN 20 ¤20.00 04/02/2021
SURCHARGE FS 533.721 ¤2.00 04/02/2021
SURCHARGE - FS 468.631 ¤2.00 04/02/2021
STORM WATER PERMIT FEES ¤80.00 04/02/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 04/02/2021
Fees Total Due: ¤0.00 Total Paid: ¤15,836.43