I want to search for...

Permit #2021030866

Permit Details

Status: COED

Parcel Id: 07-11-31-7015-RPA30-00A1
CONDITIONED SPACE: 1953 sqft
CONDITIONED SPACE: 2755 sqft
GARAGE: 605 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
OPENED PORCH (WITH ROOF) : 430 sqft
OPENED PORCH (WITH ROOF) : 275 sqft
Total Square Footage: 6118 sqft
Block: RPA30
Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE
Job Phone: (386) 445-7001
Location Address: 75 COMANCHE CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/11/2021
NOC: RECORDED
Applicant name: RICHARD M. ANDERSON
Owner: THOMAS R & EVELYN M ANDERSON

Address

31 ROEBLING ROAD

BERNARDSVILLE, NJ 07924

Lot: 00A1
Contracted Stated Job Value: ¤500,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

PALM WEST HOME BUILDERS, INC.
Status Location Address State License Number Phone Fax
ACTIVE

2 Florida Park Drive North

Palm Coast, FL 32137

CRC054633 (Exp: 08/31/2026) (386) 445-7001 (386)446-5941

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
CHRISTOPHER DANIEL FULTON
Status Location Address Mailing Address State License Number Phone
ACTIVE

2 MARKET PLACE

PALM COAST, FL 32137

UNIT D

PALM COAST, FL 32137

CCC1331939 (Exp: 08/31/2026) 386-445-7945
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 12/11/2023 APPROVED DHANEY
ROW - STORMWATER FINAL 12/11/2023 APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 12/11/2023 FINAL APPROVED DHANEY
BLD - BUILDING FINAL 12/08/2023 FINAL APPROVED BTAYLOR
BLD - BUILDING FINAL 12/07/2023 CANCELLED BY APPLICANT AWS_IVR
Note: 11/30/2023 - PREVIOUS INSPECTION NOTES 11-30-2023 1. Energy calcs. 2. Approved drawings not on site. 3. Balcony guards not per code. GUARDS AND WINDOW FALL PROTECTION R312.1 Guards Inspection stopped.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/06/2023 APPROVED EMADISON
BLD - BUILDING FINAL 11/30/2023 Disapproved - NO FEE AGAETANO
Note: 11-30-2023 1. Energy calcs. 2. Approved drawings not on site. 3. Balcony guards not per code. GUARDS AND WINDOW FALL PROTECTION R312.1 Guards Inspection stopped.
ELEVATION CERTIFICATE-FINAL APPROVAL 11/29/2023 APPROVED JMYERS
ROW - FINAL APRON (AFTER POUR) 11/27/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 11/27/2023 APPROVED EMADISON
Note: 11/20/2023 - PREVIOUS INSPECTION NOTES 1) ALONG SEA WALL NEED TO HAVE A SWALE BEFORE WALL SO SEA WALL DON'T WASH OUT 2) NEED TO FIX ALL WASH OUTS AT SEA WALL 3) POP UP FOR GUTTERS NEED TO BE ABOVE THE SOD SO SOD DON'T WASH OUT
WINDOW NAILING 11/21/2023 APPROVED BTAYLOR
Note: 5-25- 2022 - SGD second floor frame approved. Second floor windows and all doors are not installed. Window nailing will be added.
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/20/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 11/20/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) ALONG SEA WALL NEED TO HAVE A SWALE BEFORE WALL SO SEA WALL DON'T WASH OUT 2) NEED TO FIX ALL WASH OUTS AT SEA WALL 3) POP UP FOR GUTTERS NEED TO BE ABOVE THE SOD SO SOD DON'T WASH OUT
ROW- PROJECT STATUS 11/14/2023 APPROVED EMADISON
Note: ** 11/14/23 SITE MEET TO GO OVER GRADE RELATED ISSUES
ROW- PROJECT STATUS 10/09/2023 APPROVED PFLANAGAN
Note: MEET WITH BUILDER ABOUT THE GRADING OF THE LOT DO TO THE ELEVATION ON THE LOT THEY ARE PUTTING THE HIGH SPOT OF THE DRAINAGE UP TO THE FRONT OF THE HOUSE
ROW- PRE-APRON (PRE-POUR) 09/19/2023 APPROVED - AS NOTED EMADISON
Note: ** 09/19/23 READY TO SET PAVERS __________________________________________________________________________________________________________________ 9/13/2023 - PREVIOUS INSPECTION NOTES ** 09/13/23 READY TO POUR APRON AND PAVER RRESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL NEXT PRE-POUR INSPECTION HAS BEEN APPROVED ___________________________________________________________________________________________________________________
ROW- PAVER RESTRAINTS 09/13/2023 APPROVED EMADISON
Note: ** 09/13/23 READY TO POUR APRON AND PAVER RRESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh.
ROW- PRE-APRON (PRE-POUR) 09/13/2023 PARTIALLY APPROVED EMADISON
Note: ** 09/13/23 READY TO POUR APRON AND PAVER RRESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL NEXT PRE-POUR INSPECTION HAS BEEN APPROVED ___________________________________________________________________________________________________________________
ROW - DRAINAGE 04/27/2023 APPROVED EMADISON
Note: ** 04/27/23 CORRECTIONS MADE IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE EROSION CONTROL OF THE PROJECT SITE TO PREVENT A NEGATIVE IMPACT ON ADJACENT PROPERTIES ,WATERWAYS AND DRAINAGE CONVEYANCES __________________________________________________________________________________________________________________________ 4/26/2023 - PREVIOUS INSPECTION NOTES ** 04/26/23 **NO CORRECTIONS MADE BUILDER WILL HAVE UNTIL 05/03/23 TO MAKE NEEDED CORRECTIONS OR A STOP WORK ORDER WILL BE IMPOSED ON THE JOB SITE** ** BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/27/23 ____________________________________________________________________________________________________________________ 4/21/2023 - PREVIOUS INSPECTION NOTES ** 04/21/23 BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/26/23 _________________________________________________________________________________________________________________ rjg. Caller said the builder is allowing sediment to fall into the canal.
U - SEWER TIE IN 04/26/2023 APPROVED MGIBSON
ROW - DRAINAGE 04/26/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 04/26/23 **NO CORRECTIONS MADE BUILDER WILL HAVE UNTIL 05/03/23 TO MAKE NEEDED CORRECTIONS OR A STOP WORK ORDER WILL BE IMPOSED ON THE JOB SITE** ** BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/27/23 ____________________________________________________________________________________________________________________ 4/21/2023 - PREVIOUS INSPECTION NOTES ** 04/21/23 BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/26/23 _________________________________________________________________________________________________________________ rjg. Caller said the builder is allowing sediment to fall into the canal.
GRAVITY SEWER TEST 04/25/2023 APPROVED - AS NOTED MGIBSON
Note: C/M TO SCHEDUAL U-SEWER TIE IN FOR 4/26/23
ROW - DRAINAGE 04/21/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 04/21/23 BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/26/23 _________________________________________________________________________________________________________________ rjg. Caller said the builder is allowing sediment to fall into the canal.
ELECTRIC - EARLY POWER 02/06/2023 APPROVED - AS NOTED TSTAUFFACHER
Note: Release to FPL 02/06/2023-1:38 PM
ROW- PROJECT STATUS 01/26/2023 CANCELLED BY APPLICANT RGROSS
Note: Inspect for erosion going in to the canal where the seawall meets the adjacent lot check both prooperty lines.
ELECTRIC-TUG 11/04/2022 APPROVED RMARTIN
INSULATION 06/06/2022 APPROVED MKRASKI
WINDOW NAILING 05/25/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION partial 04-26-2022 - Windows, doors, and SDG not installed from prior inspection. Inspector is not sure what the partial inspection is pertaining to. Inspector reached out to the contractor and left a message. 04-26-2022 . Approved for back SGD frame and master bath rank out window. Multiple windows and doors still need to be installed. 05-25- 2022 - SGD second floor frame approved. Second floor windows and all doors are not installed. Window nailing will be added.
ALL ROUGH 05/25/2022 CANCELLED BY APPLICANT AGAETANO
Note: Contractor may have called in incorrect inspection. Window nailing will be added.
WINDOW NAILING 04/26/2022 Disapproved - NO FEE AGAETANO
Note: partial 04-26-2022 - Windows, doors, and SDG not installed from prior inspection. Inspector is not sure what the partial inspection is pertaining to. Inspector reached out to the contractor and left a message.
WINDOW NAILING 04/26/2022 PARTIALLY APPROVED AGAETANO
Note: THIS IS A REINSPECTION partial 04-26-2022 - Windows, doors, and SDG not installed from prior inspection. Inspector is not sure what the partial inspection is pertaining to. Inspector reached out to the contractor and left a message. 04-26-2022 . Approved for back SGD frame and master bath rank out window. Multiple windows and doors still need to be installed.
LATH/BRICK/ WATER BARRIER 04/21/2022 APPROVED - AS NOTED AGAETANO
Note: 1. Entry door , right side entry door, and back SDG not installed. 2. Two windows in the front left side do not have bottom stops installed. CHECK AT NEXT INSPECTION.
ALL ROUGH 04/18/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. First floor back left bathroom vent not sealed properly. 2. First floor small bathroom vent not sealed properly. 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. Head test not holding water. 10. Stopped at nine issues. All rough not ready for inspection. 4-8-22 still need the following 1. improper nail plate on A/C liquid lines top plate up stairs master bath 2. Improper nail plates on Plumbing top plates (need to cover plates and extent 2 inches below). P2603.2.1 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. PVC piping maximum distance for horizontal support is 4 feet per TABLE P2605.1 PIPING SUPPORT 04-18-2022 Multiple windows, doors, and SGD not installed. Window nailing added. 1. Second floor exterior door at master bed. 2. Master bed side window. 3. Second floor SGD. 4. Front right small window. 5. Master bed canal side ( triple window). 6. First floor exterior doors. 7. First floor back SGD. 8. Front entry. Contractor will cover openings with Tyvek for insulation inspection.
ALL ROUGH 04/08/2022 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION 1. First floor back left bathroom vent not sealed properly. 2. First floor small bathroom vent not sealed properly. 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. Head test not holding water. 10. Stopped at nine issues. All rough not ready for inspection. 4-8-22 still need the following 1. improper nail plate on A/C liquid lines top plate up stairs master bath 2. Improper nail plates on Plumbing top plates (need to cover plates and extent 2 inches below). P2603.2.1 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. PVC piping maximum distance for horizontal support is 4 feet per TABLE P2605.1 PIPING SUPPORT
ALL ROUGH 03/28/2022 Disapproved - NO FEE AGAETANO
Note: 1. First floor back left bathroom vent not sealed properly. 2. First floor small bathroom vent not sealed properly. 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. Head test not holding water. 10. Stopped at nine issues. All rough not ready for inspection.
ROOF VALLEY & METAL 03/25/2022 APPROVED RMARTIN
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/08/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Approved drawings and engineer packet needs to be on site. 1. T26 missing HUS26 2. Second floor open porch trusses need straps and engineer needs to submit a detail for beam. 3. T 3,4,5 missing HUS26. 4. T22 missing strap. 5. T25 missing engineered framing. 6. Engineer to submit revision for extra wall anchors to trusses. (all thread). CANTELEVERED TRUSSES @ PORCH DO NOT NEED STRAPS AT OUTER EDGE
WALL SHEATHING 01/27/2022 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/26/2022 Disapproved - NO FEE AGAETANO
Note: THIS IS A REINSPECTION Approved drawings and engineer packet needs to be on site. 1. T26 missing HUS26 2. Second floor open porch trusses need straps and engineer needs to submit a detail for beam. 3. T 3,4,5 missing HUS26. 4. T22 missing strap. 5. T25 missing engineered framing. 6. Engineer to submit revision for extra wall anchors to trusses. (all thread).
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/25/2022 Disapproved - NO FEE AGAETANO
Note: Approved drawings and engineer packet needs to be on site.
ROW - DRAINAGE 01/14/2022 APPROVED - AS NOTED KRUTH
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION The applicant needs to: 1) Remove all blockages in swale 2) Repai silt fencing 3) Remove silt from canal Re-inspection date is 1-12-22 #2) silt fence still needs repairs next inspection 1/14/21 corrections made
ROW - DRAINAGE 01/12/2022 Disapproved -FEE REQUIRED KRUTH
Note: THIS IS A REINSPECTION The applicant needs to: 1) Remove all blockages in swale 2) Repai silt fencing 3) Remove silt from canal Re-inspection date is 1-12-22 #2) silt fence still needs repairs next inspection 1/14/21
ELECTRIC TEMP POLE 01/12/2022 APPROVED - AS NOTED RMARTIN
Note: EMAILED FPL RELEASED POWER 3:50
ROW - DRAINAGE 01/05/2022 Disapproved -FEE REQUIRED CTROHA
Note: The applicant needs to: 1) Remove all blockages in swale 2) Repai silt fencing 3) Remove silt from canal Re-inspection date is 1-12-22
ELEV CERT-FOUNDATION APPROVAL 12/08/2021 APPROVED JMYERS
TIE BEAM / LINTEL 11/03/2021 APPROVED LMILLER
TIE BEAM / LINTEL 10/21/2021 CANCELLED BY APPLICANT AWS_IVR
Note: THIS IS A REINSPECTION Need to have a set of approved drawings on site for inspections. unable to verify location of down cells. The left side of the building the lengt of the block wall is not fully bearing on the foundation and is over hanging appx. 2" Have engineer submitt a letter to the building department, stating the as built wall not fully bearing location is ok, or a revision on how to fix.
TIE BEAM / LINTEL 10/20/2021 Disapproved - NO FEE JWALKER
Note: Need to have a set of approved drawings on site for inspections. unable to verify location of down cells. The left side of the building the lengt of the block wall is not fully bearing on the foundation and is over hanging appx. 2" Have engineer submitt a letter to the building department, stating the as built wall not fully bearing location is ok, or a revision on how to fix.
FOUND SURVEY APPROVED (OFFICE) 10/07/2021 APPROVED TBAKER
MONOLITHIC SLAB 08/24/2021 APPROVED WMILLER
Note: THIS IS A REINSPECTION Per contractor footing for spiral stairs to second floor in back needs to be poured at a later dae to prevent damage during construction. (must call in separate footing inepection) (footing inspection added to permit) also footing A-F not as proposed 8-24-21... notes above resolved
MONOLITHIC SLAB 08/23/2021 Disapproved - NO FEE WMILLER
Note: Per contractor footing for spiral stairs to second floor in back needs to be poured at a later dae to prevent damage during construction. (must call in separate footing inepection) (footing inspection added to permit) also footing A-F not as proposed
PLUMBING 1ST ROUGH UNDERGROUND 07/28/2021 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 06/15/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 12/04/2023 12/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 11/29/2023 11/29/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Final elevation certificate has been approved.
PLFM HOLD 11/21/2023 11/21/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM A9 a-e need to be 0 not N/A per the FEMA instructions, but A9f may remain N/A. If you are going to round up the garage FFE from 9.05 to 9.1 then you also need to round up the house FFE from 9.55 to 9.6 to be consistent for C2a. There are lower elevations shown on the Final Survey adjacent to the building than 9.0, please revise C2f.
BADMIN INFORMATION 11/16/2023 11/16/2023
Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM inspection could not be scheduled the COI is expired.
ZON COMPLETE 09/28/2023 09/29/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/28/2023 09/28/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/28/2023 09/28/2023
Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM
ZON CANCEL 09/22/2023 09/22/2023
ENGIN1 COMPLETE 09/22/2023 09/25/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/22/2023 09/25/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 09/22/2023 09/22/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM PLease provide the setback from the walkway to property line.
ENGIN1 COMPLETE 09/21/2023 09/21/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/21/2023 09/25/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 09/21/2023 09/21/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Showing a generator pad will need all the set backs for the pad to the property line. Please know that you do not have a generator permit and need one if your installing that . I will only be approving pad location once you provide setbacks. PLease provide the setback from the walkway to property line.
ZON COMPLETE 07/12/2023 07/12/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/12/2023 07/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/12/2023 07/18/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/29/2023 06/29/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Dock must be on a seperate permit.Take it off the site plan/ survey. Driveway turn around is too big. Please adjust plan accordingly to code below. The Land Development Code allows for turnarounds, but the City recognizes turnarounds as parking space size, which is 9’ wide by 18’ long. Additionally, the driveway turn-around cannot be located within 5 feet of the side property line
ZON HOLD 06/28/2023 06/29/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please be more descriptive in the manual revision sheet of all changes made to site plan since your approved revision. Drive way area: please know that the turn around does not meet the code anymore please see code below The Land Development Code allows for turnarounds, but the City recognizes turnarounds as parking space size, which is 9’ wide by 18’ long. Additionally, the driveway turn-around cannot be located within 5 feet of the side property line
ENGIN1 COMPLETE 06/28/2023 06/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/28/2023 07/05/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
SW1 COMPLETE 06/14/2023 06/14/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 06/12/2023 06/13/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: please use a site plan for all proposed changes. Can not put a 10 x 20 patio in the rear as it does not meet the 6.5' setback. Provide the rear set back from back of home patio to the property line. (left side rear corner. Provide the width of the driveway and please know that it can not exceed 36' at its widest point.
ENGIN1 COMPLETE 06/12/2023 06/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ELEC COMPLETE 01/13/2023 01/18/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 01/13/2023 01/13/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 01/12/2023 01/13/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 01/12/2023 01/12/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 01/12/2023 01/12/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Site plan must show dimensions and setbacks of proposed generator to side property line.
ENGIN1 COMPLETE 01/12/2023 01/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ELEC COMPLETE 01/11/2023 01/13/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/10/2022 03/10/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
BLD HOLD 03/07/2022 03/07/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Revision: Product approval of garage door: Submitted product approval number FL 32170 with model 192 cannot be found on approval Listing. Please verify the number - FBC 7th Ed. Sec. 107.3.
BLD COMPLETE 02/02/2022 02/07/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
PLFM COMPLETE 12/08/2021 12/08/2021
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Foundation elevation certificate has been approved. Please provide Final prior to CO.
PLFM HOLD 12/06/2021 12/06/2021
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM A9 is missing the square footage of the garage. B1 is missing the Community Number.
BLD COMPLETE 11/02/2021 11/02/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 10/28/2021 10/29/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/06/2021 10/07/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/06/2021 10/07/2021
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 07/14/2021 07/20/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
BLD COMPLETE 06/03/2021 06/10/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
BLD COMPLETE 05/04/2021 05/11/2021
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
MECH COMPLETE 04/26/2021 04/28/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 04/26/2021 05/03/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment: 3. Provide Product approval per F.S. 553.842. a. Soffits, Note : Submitted FL 24161.1 for soffitts cannot be found on FL Product Approval Listing. Please verify the FL Number.
MECH HOLD 04/16/2021 04/19/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 insulation in attic and R4.1 on block walls. Energy calcs say R21 on roof deck and R5 on block walls. Revise to match. Revise details plan sheet to match the energy calcs or revise energy calcs. If Energy Calcs are correct then also change details plan to show non vented soffit
PLFM COMPLETE 04/16/2021 04/16/2021
Note: Released By: JORDAN MYERS - (904)562-0045 - JMYERS@PALMCOASTGOV.COM The Construction elevation certificate has been accepted. Please provide Foundation and Final prior to receiving CO.
ZON COMPLETE 04/16/2021 04/16/2021
Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 04/16/2021 04/19/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLUM COMPLETE 04/16/2021 04/20/2021
Note: Released By: BARBIE BEMBRY - - BUILDINGDIVISION@PALMCOASTGOV.COM Plumbing review no longer required. All items in plumbing code will checked in the field by the inspector.
BLD HOLD 04/16/2021 04/21/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment: 3. Provide Product approval per F.S. 553.842. a. Soffits, Note : Submitted FL 415-0229 cannot be found on FL Product Approval Listing. Please verify the FL Number.
MECH HOLD 04/06/2021 04/07/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 insulation in attic and R4.1 on block walls. Energy calcs say R21 on roof deck and R5 on block walls. Revise to match. (Second Request)
ELEC HOLD 04/06/2021 04/08/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM outlets in kitchen area and bathroom area need to be GFCI. NEC 2017 210.8
PLFM HOLD 04/06/2021 04/07/2021
Note: Held By: JORDAN MYERS - (904)562-0045 - JMYERS@PALMCOASTGOV.COM Please note the type of equipment from C2e in the comments area of Section D. There must be a signature and date on top of the seal in the box in Section D as well as in the signature box.
ZON HOLD 04/06/2021 04/07/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Additional shrub required on left side to total four along side No new landscape plan submitted
PLUM HOLD 04/06/2021 04/13/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comments: 1. Sanitary riser diagram at first floor: All refernces are 2020 FBCP 7th Edition. a. Provide complete vent sizes of fixture drains serving laundry room and bathroom suite 2 - Secs. 901.2/901.2.1. Also, indicate discharge location and main vent size in accordance with the total drainage fixture units -Table 710.1(2). b. Washing machine at laundry room shall vented - Sec. 905.4. 2. Sanitary riser diagram at second floor: a. Provide vent for kitchen sink fixture drain - Secs.901.2/901.2.1. b. Vent size of 2 inches of soil stack through the roof serving master bathroomm and its adjacent bathroom (great room bathroom ) does not comply with the required total dainage fixture units - Table 710.1(2).
BLD HOLD 04/06/2021 04/06/2021
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENT NO. 3 FROM PREVIOUS REVIEW HOLD ASKING FOR A ROOF FRAMING PLAN HAS BEEN REMOVED AS THE ROOF FRAMING PLAN WAS REQUESTED TO BE A DEFERRED SUBMITTAL. PLEASE RESPOND TO REMAINING REVIEW COMMENTS BELOW. THANK YOU. 1. First Floor: a. Typical Spiral Detail- refers to manufacturer's specificaion and details - cannot be found. Please provide. 2. Second floor: a. Gas burning fire place - provide manufacturer's specification and installation instructions per FBCR 7th Ed. Sec. R1004. b. Typical Guard Detail:- shall be designed to resist a concentrated load of 200 lbs per FBCB 7h Ed. Sec. 1607.8.1.1. 3. Provide Product approval per F.S. 553.842. a. Soffits, structural components such as wood connectors, wood anchors, truss plates and lintels. b. Provide roofing underlayment on Roofing Worksheet. Please note that there are significant 2020 Code Changes on roof covering material and roof undelaymen per FBCR 7th Ed. Sec. R905.1.1 or per FBCB 7th Ed. Sec. 1507.1.1.1.
BLD HOLD 04/06/2021 04/13/2021
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comments: 1. First Floor: a. Typical Spiral Detail- refers to manufacturer's specification and details - cannot be found. Please provide. 2. Second floor: a. Gas burning fire place - provide manufacturer's specification and installation instructions per FBCR 7th Ed. Sec. R1004. b. Typical Guard Detail:- shall be designed to resist a concentrated load of 200 lbs per FBCB 7h Ed. Sec. 1607.8.1.1. 3. Provide Product approval per F.S. 553.842. a. Soffits, structural components such as wood connectors, wood anchors, truss plates and lintels.
ENGIN1 COMPLETE 04/06/2021 04/07/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US
SW1 COMPLETE 04/06/2021 04/12/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
PLFM HOLD 03/16/2021 03/16/2021
Note: Held By: JORDAN MYERS - (386)986-2320 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted, the structure will fall inside the Special Flood Hazard Area. Elevation Certificates will be required at construction drawings, foundation, and final.
SWALE COMPLETE 03/15/2021 06/10/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 03/12/2021 03/19/2021
Note: Held By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us 1. First Floor: a. Typical Spiral Detail- refers to manufacturer's specificaion and details - cannot be found. Please provide. 2. Second floor: a. Gas burning fire place - provide manufacturer's specification and installation instructions per FBCR 7th Ed. Sec. R1004. b. Typical Guard Detail:- shall be designed to resist a concentrated load of 200 lbs per FBCB 7h Ed. Sec. 1607.8.1.1. 3. Provide roof framing layout per FBCR 7th Ed. Sec 801/801.2. 4. Provide Product approval per F.S. 553.842. a. Soffits, structural components such as wood connectors, wood anchors, truss plates and lintels. b. Provide roofing underlayment on Roofing Worksheet. Please note that there are significant 2020 Code Changes on roof covering material and roof undelaymen per FBCR 7th Ed. Sec. R905.1.1 or per FBCB 7th Ed. Sec. 1507.1.1.1.
CUSVC COMPLETE 03/12/2021 03/19/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 03/12/2021 03/15/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outlets in kitchen area and bathroom area need to be GFCI. NEC 2017 210.8
ENGIN1 COMPLETE 03/12/2021 03/15/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US
LOCATE COMPLETE 03/12/2021 03/18/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 03/12/2021 03/15/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 insulation in attic and R4.1 on block walls. Energy calcs say R21 on roof deck and R5 on block walls. Revise to match. 2. Energy Calcs need to be signed by the builder
PLUM HOLD 03/12/2021 03/19/2021
Note: Held By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us 1. Sanitary riser diagram at first floor: All refernces are 2020 FBCP 7th Edition. a. Provide complete vent sizes of fixture drains serving laundry room and bathroom suite 2 - Secs. 901.2/901.2.1. Also, indicate discharge location and main vent size in accordance with the total drainage fixture units -Table 710.1(2). b. Washing machine at laundry room shall vented - Sec. 905.4. 2. Sanitary riser diagram at second floor: a. Provide vent for kitchen sink fixture drain - Secs.901.2/901.2.1. b. Vent size of 2 inches of soil stack through the roof serving master bathroomm and its adjacent bathroom (great room bathroom ) does not comply with the required total dainage fixture units - Table 710.1(2).
SW1 COMPLETE 03/12/2021 03/19/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 03/12/2021 03/16/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Please demonstrate that the house does not exceed the maximum building height of 35ft Please show height,material of privacy wall and that it will match house Survey/site plan missing total lot square footage Survey notes missing the AE flood zone Survey/site plan states 1 story but house plans show 2 story Driveway turnaround must be labeled on survey/site plan and provide the dimensions. A turnaround can not exceed 9ft in width and 18ft in length Please show front entry walkway width and material on site plan survey Please show front setback from the front entry Additional shrub required on left side to total four along side

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 12/11/2023
PLAN REVIEW - REVISION ¤32.50 12/11/2023
PLAN REVIEW - REVISION ¤32.50 12/11/2023
REINSPECTION RESIDENTIAL ¤40.00 12/11/2023
RECORDING FEE REIMBURSE DOC ¤44.00 12/11/2023
SW ENG - INSPECTION 20 ¤20.00 12/11/2023
SW ENG - INSPECTION 20 ¤20.00 12/11/2023
SW ENG - INSPECTION 20 ¤20.00 12/11/2023
SW ENG - INSPECTION 20 ¤20.00 12/11/2023
SW ENG - INSPECTION 20 ¤20.00 12/11/2023
SW ENG - INSPECTION 20 ¤20.00 12/11/2023
SW ENG - INSPECTION 20 ¤20.00 12/11/2023
SW ENG REINSPECTION 20 ¤20.00 12/11/2023
SW ENG REINSPECTION 20 ¤20.00 12/11/2023
SW ENG REINSPECTION 20 ¤20.00 12/11/2023
STORM WATER PERMIT FEES ¤80.00 05/11/2021
3% TRANS IMPACT FEE CREDIT (¤94.17) 05/11/2021
SEWER INSPECTION ¤25.00 05/11/2021
SEWER CAPITAL FACILITY ¤4,664.55 05/11/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 05/11/2021
METER - DEPOSIT ¤60.00 05/11/2021
WATER- TURN ON ¤25.00 05/11/2021
ADMIN FEE ¤20.00 05/11/2021
IMPACT FEE TRANSPORTATION ¤3,139.00 05/11/2021
MECHANICAL FEE ¤407.40 05/11/2021
WATER -IRRIGATION INSPECTION ¤25.00 05/11/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 05/11/2021
PLAN CHECK FEE ¤231.60 05/11/2021
PLUMBING FEE ¤407.40 05/11/2021
NEW RESIDENTIAL INSPECTIONS ¤1,158.00 05/11/2021
SITE PLAN 20 ¤20.00 05/11/2021
SURCHARGE FS 533.721 ¤2.00 05/11/2021
SURCHARGE - FS 468.631 ¤2.00 05/11/2021
CONNECTION FEES ¤1,017.83 05/11/2021
BUILDING DISCOUNT 100% (¤2,631.80) 05/11/2021
ELECTRIC FEE ¤407.40 05/11/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 05/11/2021
IMPACT FEE FIRE ¤367.00 05/11/2021
IMPACT FEE PARKS ¤1,199.12 05/11/2021
IMPACT FEE SCHOOL ¤3,600.00 05/11/2021
Fees Total Due: ¤0.00 Total Paid: ¤17,891.30