Permit #2021030866
Permit Details
Status: COED
| Parcel Id: 07-11-31-7015-RPA30-00A1 |
| CONDITIONED SPACE: 1953 sqft |
| CONDITIONED SPACE: 2755 sqft |
| GARAGE: 605 sqft |
| OPENED PORCH (WITH ROOF) : 100 sqft |
| OPENED PORCH (WITH ROOF) : 430 sqft |
| OPENED PORCH (WITH ROOF) : 275 sqft |
| Total Square Footage: 6118 sqft |
| Block: RPA30 |
| Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE |
| Job Phone: (386) 445-7001 |
| Location Address: 75 COMANCHE CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/11/2021 |
| NOC: RECORDED |
| Applicant name: RICHARD M. ANDERSON |
| Owner: THOMAS R & EVELYN M ANDERSON |
|
Address 31 ROEBLING ROAD BERNARDSVILLE, NJ 07924 |
| Lot: 00A1 |
| Contracted Stated Job Value: ¤500,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
PALM WEST HOME BUILDERS, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2 Florida Park Drive North Palm Coast, FL 32137 |
CRC054633 (Exp: 08/31/2026) | (386) 445-7001 | (386)446-5941 |
Sub Contractors
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
CHRISTOPHER DANIEL FULTON
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2 MARKET PLACE PALM COAST, FL 32137 |
UNIT D PALM COAST, FL 32137 |
CCC1331939 (Exp: 08/31/2026) | 386-445-7945 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| U-CROSS CONNECTION | 12/11/2023 | APPROVED | DHANEY |
| ROW - STORMWATER FINAL | 12/11/2023 | APPROVED | EMADISON |
| U -UTILITY RESIDENTIAL FINAL | 12/11/2023 | FINAL APPROVED | DHANEY |
| BLD - BUILDING FINAL | 12/08/2023 | FINAL APPROVED | BTAYLOR |
| BLD - BUILDING FINAL | 12/07/2023 | CANCELLED BY APPLICANT | AWS_IVR |
| Note: 11/30/2023 - PREVIOUS INSPECTION NOTES 11-30-2023 1. Energy calcs. 2. Approved drawings not on site. 3. Balcony guards not per code. GUARDS AND WINDOW FALL PROTECTION R312.1 Guards Inspection stopped. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/06/2023 | APPROVED | EMADISON |
| BLD - BUILDING FINAL | 11/30/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 11-30-2023 1. Energy calcs. 2. Approved drawings not on site. 3. Balcony guards not per code. GUARDS AND WINDOW FALL PROTECTION R312.1 Guards Inspection stopped. | |||
| ELEVATION CERTIFICATE-FINAL APPROVAL | 11/29/2023 | APPROVED | JMYERS |
| ROW - FINAL APRON (AFTER POUR) | 11/27/2023 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/27/2023 | APPROVED | EMADISON |
| Note: 11/20/2023 - PREVIOUS INSPECTION NOTES 1) ALONG SEA WALL NEED TO HAVE A SWALE BEFORE WALL SO SEA WALL DON'T WASH OUT 2) NEED TO FIX ALL WASH OUTS AT SEA WALL 3) POP UP FOR GUTTERS NEED TO BE ABOVE THE SOD SO SOD DON'T WASH OUT | |||
| WINDOW NAILING | 11/21/2023 | APPROVED | BTAYLOR |
| Note: 5-25- 2022 - SGD second floor frame approved. Second floor windows and all doors are not installed. Window nailing will be added. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/20/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/20/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) ALONG SEA WALL NEED TO HAVE A SWALE BEFORE WALL SO SEA WALL DON'T WASH OUT 2) NEED TO FIX ALL WASH OUTS AT SEA WALL 3) POP UP FOR GUTTERS NEED TO BE ABOVE THE SOD SO SOD DON'T WASH OUT | |||
| ROW- PROJECT STATUS | 11/14/2023 | APPROVED | EMADISON |
| Note: ** 11/14/23 SITE MEET TO GO OVER GRADE RELATED ISSUES | |||
| ROW- PROJECT STATUS | 10/09/2023 | APPROVED | PFLANAGAN |
| Note: MEET WITH BUILDER ABOUT THE GRADING OF THE LOT DO TO THE ELEVATION ON THE LOT THEY ARE PUTTING THE HIGH SPOT OF THE DRAINAGE UP TO THE FRONT OF THE HOUSE | |||
| ROW- PRE-APRON (PRE-POUR) | 09/19/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 09/19/23 READY TO SET PAVERS __________________________________________________________________________________________________________________ 9/13/2023 - PREVIOUS INSPECTION NOTES ** 09/13/23 READY TO POUR APRON AND PAVER RRESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL NEXT PRE-POUR INSPECTION HAS BEEN APPROVED ___________________________________________________________________________________________________________________ | |||
| ROW- PAVER RESTRAINTS | 09/13/2023 | APPROVED | EMADISON |
| Note: ** 09/13/23 READY TO POUR APRON AND PAVER RRESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/13/2023 | PARTIALLY APPROVED | EMADISON |
| Note: ** 09/13/23 READY TO POUR APRON AND PAVER RRESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL NEXT PRE-POUR INSPECTION HAS BEEN APPROVED ___________________________________________________________________________________________________________________ | |||
| ROW - DRAINAGE | 04/27/2023 | APPROVED | EMADISON |
| Note: ** 04/27/23 CORRECTIONS MADE IT IS THE BUILDERS RESPONSIBILITY TO MAINTAIN THE EROSION CONTROL OF THE PROJECT SITE TO PREVENT A NEGATIVE IMPACT ON ADJACENT PROPERTIES ,WATERWAYS AND DRAINAGE CONVEYANCES __________________________________________________________________________________________________________________________ 4/26/2023 - PREVIOUS INSPECTION NOTES ** 04/26/23 **NO CORRECTIONS MADE BUILDER WILL HAVE UNTIL 05/03/23 TO MAKE NEEDED CORRECTIONS OR A STOP WORK ORDER WILL BE IMPOSED ON THE JOB SITE** ** BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/27/23 ____________________________________________________________________________________________________________________ 4/21/2023 - PREVIOUS INSPECTION NOTES ** 04/21/23 BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/26/23 _________________________________________________________________________________________________________________ rjg. Caller said the builder is allowing sediment to fall into the canal. | |||
| U - SEWER TIE IN | 04/26/2023 | APPROVED | MGIBSON |
| ROW - DRAINAGE | 04/26/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 04/26/23 **NO CORRECTIONS MADE BUILDER WILL HAVE UNTIL 05/03/23 TO MAKE NEEDED CORRECTIONS OR A STOP WORK ORDER WILL BE IMPOSED ON THE JOB SITE** ** BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/27/23 ____________________________________________________________________________________________________________________ 4/21/2023 - PREVIOUS INSPECTION NOTES ** 04/21/23 BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/26/23 _________________________________________________________________________________________________________________ rjg. Caller said the builder is allowing sediment to fall into the canal. | |||
| GRAVITY SEWER TEST | 04/25/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: C/M TO SCHEDUAL U-SEWER TIE IN FOR 4/26/23 | |||
| ROW - DRAINAGE | 04/21/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 04/21/23 BUILDER NEEDS TO RE-ESTABLISH THE SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AS EROSION OF MATERIAL IS NEGATIVELY IMPACTING THE CAAL ** SILT FENCE NEEDS TO BE BURIED 4 INCHES IN THE GROUND TO HELP PREVENT ERODED MATERIAL FROM PASSIG UNDER AND DEPOSITING INTO THE CANAL. ** SEE ATTACHED PHOTOS ** FOLLOW ISPECTION O 04/26/23 _________________________________________________________________________________________________________________ rjg. Caller said the builder is allowing sediment to fall into the canal. | |||
| ELECTRIC - EARLY POWER | 02/06/2023 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: Release to FPL 02/06/2023-1:38 PM | |||
| ROW- PROJECT STATUS | 01/26/2023 | CANCELLED BY APPLICANT | RGROSS |
| Note: Inspect for erosion going in to the canal where the seawall meets the adjacent lot check both prooperty lines. | |||
| ELECTRIC-TUG | 11/04/2022 | APPROVED | RMARTIN |
| INSULATION | 06/06/2022 | APPROVED | MKRASKI |
| WINDOW NAILING | 05/25/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION partial 04-26-2022 - Windows, doors, and SDG not installed from prior inspection. Inspector is not sure what the partial inspection is pertaining to. Inspector reached out to the contractor and left a message. 04-26-2022 . Approved for back SGD frame and master bath rank out window. Multiple windows and doors still need to be installed. 05-25- 2022 - SGD second floor frame approved. Second floor windows and all doors are not installed. Window nailing will be added. | |||
| ALL ROUGH | 05/25/2022 | CANCELLED BY APPLICANT | AGAETANO |
| Note: Contractor may have called in incorrect inspection. Window nailing will be added. | |||
| WINDOW NAILING | 04/26/2022 | Disapproved - NO FEE | AGAETANO |
| Note: partial 04-26-2022 - Windows, doors, and SDG not installed from prior inspection. Inspector is not sure what the partial inspection is pertaining to. Inspector reached out to the contractor and left a message. | |||
| WINDOW NAILING | 04/26/2022 | PARTIALLY APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION partial 04-26-2022 - Windows, doors, and SDG not installed from prior inspection. Inspector is not sure what the partial inspection is pertaining to. Inspector reached out to the contractor and left a message. 04-26-2022 . Approved for back SGD frame and master bath rank out window. Multiple windows and doors still need to be installed. | |||
| LATH/BRICK/ WATER BARRIER | 04/21/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: 1. Entry door , right side entry door, and back SDG not installed. 2. Two windows in the front left side do not have bottom stops installed. CHECK AT NEXT INSPECTION. | |||
| ALL ROUGH | 04/18/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. First floor back left bathroom vent not sealed properly. 2. First floor small bathroom vent not sealed properly. 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. Head test not holding water. 10. Stopped at nine issues. All rough not ready for inspection. 4-8-22 still need the following 1. improper nail plate on A/C liquid lines top plate up stairs master bath 2. Improper nail plates on Plumbing top plates (need to cover plates and extent 2 inches below). P2603.2.1 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. PVC piping maximum distance for horizontal support is 4 feet per TABLE P2605.1 PIPING SUPPORT 04-18-2022 Multiple windows, doors, and SGD not installed. Window nailing added. 1. Second floor exterior door at master bed. 2. Master bed side window. 3. Second floor SGD. 4. Front right small window. 5. Master bed canal side ( triple window). 6. First floor exterior doors. 7. First floor back SGD. 8. Front entry. Contractor will cover openings with Tyvek for insulation inspection. | |||
| ALL ROUGH | 04/08/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: THIS IS A REINSPECTION 1. First floor back left bathroom vent not sealed properly. 2. First floor small bathroom vent not sealed properly. 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. Head test not holding water. 10. Stopped at nine issues. All rough not ready for inspection. 4-8-22 still need the following 1. improper nail plate on A/C liquid lines top plate up stairs master bath 2. Improper nail plates on Plumbing top plates (need to cover plates and extent 2 inches below). P2603.2.1 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. PVC piping maximum distance for horizontal support is 4 feet per TABLE P2605.1 PIPING SUPPORT | |||
| ALL ROUGH | 03/28/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 1. First floor back left bathroom vent not sealed properly. 2. First floor small bathroom vent not sealed properly. 3. First floor front left 2" pipe not strapped properly and sagging. 4. First and second floor windows and doors not completely installed. 5. Front window at left of entry does not ope completely. 6. Temporary railing not safe at second floor. 7. Second floor 2" pipe at back of deck over entry door is not strapped properly. 8. Second floor master bath 2" pipe at attic not strapped properly. 9. Head test not holding water. 10. Stopped at nine issues. All rough not ready for inspection. | |||
| ROOF VALLEY & METAL | 03/25/2022 | APPROVED | RMARTIN |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/08/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Approved drawings and engineer packet needs to be on site. 1. T26 missing HUS26 2. Second floor open porch trusses need straps and engineer needs to submit a detail for beam. 3. T 3,4,5 missing HUS26. 4. T22 missing strap. 5. T25 missing engineered framing. 6. Engineer to submit revision for extra wall anchors to trusses. (all thread). CANTELEVERED TRUSSES @ PORCH DO NOT NEED STRAPS AT OUTER EDGE | |||
| WALL SHEATHING | 01/27/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/26/2022 | Disapproved - NO FEE | AGAETANO |
| Note: THIS IS A REINSPECTION Approved drawings and engineer packet needs to be on site. 1. T26 missing HUS26 2. Second floor open porch trusses need straps and engineer needs to submit a detail for beam. 3. T 3,4,5 missing HUS26. 4. T22 missing strap. 5. T25 missing engineered framing. 6. Engineer to submit revision for extra wall anchors to trusses. (all thread). | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/25/2022 | Disapproved - NO FEE | AGAETANO |
| Note: Approved drawings and engineer packet needs to be on site. | |||
| ROW - DRAINAGE | 01/14/2022 | APPROVED - AS NOTED | KRUTH |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION The applicant needs to: 1) Remove all blockages in swale 2) Repai silt fencing 3) Remove silt from canal Re-inspection date is 1-12-22 #2) silt fence still needs repairs next inspection 1/14/21 corrections made | |||
| ROW - DRAINAGE | 01/12/2022 | Disapproved -FEE REQUIRED | KRUTH |
| Note: THIS IS A REINSPECTION The applicant needs to: 1) Remove all blockages in swale 2) Repai silt fencing 3) Remove silt from canal Re-inspection date is 1-12-22 #2) silt fence still needs repairs next inspection 1/14/21 | |||
| ELECTRIC TEMP POLE | 01/12/2022 | APPROVED - AS NOTED | RMARTIN |
| Note: EMAILED FPL RELEASED POWER 3:50 | |||
| ROW - DRAINAGE | 01/05/2022 | Disapproved -FEE REQUIRED | CTROHA |
| Note: The applicant needs to: 1) Remove all blockages in swale 2) Repai silt fencing 3) Remove silt from canal Re-inspection date is 1-12-22 | |||
| ELEV CERT-FOUNDATION APPROVAL | 12/08/2021 | APPROVED | JMYERS |
| TIE BEAM / LINTEL | 11/03/2021 | APPROVED | LMILLER |
| TIE BEAM / LINTEL | 10/21/2021 | CANCELLED BY APPLICANT | AWS_IVR |
| Note: THIS IS A REINSPECTION Need to have a set of approved drawings on site for inspections. unable to verify location of down cells. The left side of the building the lengt of the block wall is not fully bearing on the foundation and is over hanging appx. 2" Have engineer submitt a letter to the building department, stating the as built wall not fully bearing location is ok, or a revision on how to fix. | |||
| TIE BEAM / LINTEL | 10/20/2021 | Disapproved - NO FEE | JWALKER |
| Note: Need to have a set of approved drawings on site for inspections. unable to verify location of down cells. The left side of the building the lengt of the block wall is not fully bearing on the foundation and is over hanging appx. 2" Have engineer submitt a letter to the building department, stating the as built wall not fully bearing location is ok, or a revision on how to fix. | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/07/2021 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/24/2021 | APPROVED | WMILLER |
| Note: THIS IS A REINSPECTION Per contractor footing for spiral stairs to second floor in back needs to be poured at a later dae to prevent damage during construction. (must call in separate footing inepection) (footing inspection added to permit) also footing A-F not as proposed 8-24-21... notes above resolved | |||
| MONOLITHIC SLAB | 08/23/2021 | Disapproved - NO FEE | WMILLER |
| Note: Per contractor footing for spiral stairs to second floor in back needs to be poured at a later dae to prevent damage during construction. (must call in separate footing inepection) (footing inspection added to permit) also footing A-F not as proposed | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 07/28/2021 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 06/15/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/04/2023 | 12/05/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 11/29/2023 | 11/29/2023 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Final elevation certificate has been approved. | |||
| PLFM | HOLD | 11/21/2023 | 11/21/2023 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM A9 a-e need to be 0 not N/A per the FEMA instructions, but A9f may remain N/A. If you are going to round up the garage FFE from 9.05 to 9.1 then you also need to round up the house FFE from 9.55 to 9.6 to be consistent for C2a. There are lower elevations shown on the Final Survey adjacent to the building than 9.0, please revise C2f. | |||
| BADMIN | INFORMATION | 11/16/2023 | 11/16/2023 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM inspection could not be scheduled the COI is expired. | |||
| ZON | COMPLETE | 09/28/2023 | 09/29/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/28/2023 | 09/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/28/2023 | 09/28/2023 |
| Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM | |||
| ZON | CANCEL | 09/22/2023 | 09/22/2023 |
| ENGIN1 | COMPLETE | 09/22/2023 | 09/25/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/22/2023 | 09/25/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/22/2023 | 09/22/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM PLease provide the setback from the walkway to property line. | |||
| ENGIN1 | COMPLETE | 09/21/2023 | 09/21/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/21/2023 | 09/25/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/21/2023 | 09/21/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Showing a generator pad will need all the set backs for the pad to the property line. Please know that you do not have a generator permit and need one if your installing that . I will only be approving pad location once you provide setbacks. PLease provide the setback from the walkway to property line. | |||
| ZON | COMPLETE | 07/12/2023 | 07/12/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/12/2023 | 07/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/12/2023 | 07/18/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/29/2023 | 06/29/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Dock must be on a seperate permit.Take it off the site plan/ survey. Driveway turn around is too big. Please adjust plan accordingly to code below. The Land Development Code allows for turnarounds, but the City recognizes turnarounds as parking space size, which is 9’ wide by 18’ long. Additionally, the driveway turn-around cannot be located within 5 feet of the side property line | |||
| ZON | HOLD | 06/28/2023 | 06/29/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please be more descriptive in the manual revision sheet of all changes made to site plan since your approved revision. Drive way area: please know that the turn around does not meet the code anymore please see code below The Land Development Code allows for turnarounds, but the City recognizes turnarounds as parking space size, which is 9’ wide by 18’ long. Additionally, the driveway turn-around cannot be located within 5 feet of the side property line | |||
| ENGIN1 | COMPLETE | 06/28/2023 | 06/29/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/28/2023 | 07/05/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/14/2023 | 06/14/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/12/2023 | 06/13/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: please use a site plan for all proposed changes. Can not put a 10 x 20 patio in the rear as it does not meet the 6.5' setback. Provide the rear set back from back of home patio to the property line. (left side rear corner. Provide the width of the driveway and please know that it can not exceed 36' at its widest point. | |||
| ENGIN1 | COMPLETE | 06/12/2023 | 06/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/13/2023 | 01/18/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/13/2023 | 01/13/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/12/2023 | 01/13/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/12/2023 | 01/12/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 01/12/2023 | 01/12/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Site plan must show dimensions and setbacks of proposed generator to side property line. | |||
| ENGIN1 | COMPLETE | 01/12/2023 | 01/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/11/2023 | 01/13/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/10/2022 | 03/10/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/07/2022 | 03/07/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Revision: Product approval of garage door: Submitted product approval number FL 32170 with model 192 cannot be found on approval Listing. Please verify the number - FBC 7th Ed. Sec. 107.3. | |||
| BLD | COMPLETE | 02/02/2022 | 02/07/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 12/08/2021 | 12/08/2021 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Foundation elevation certificate has been approved. Please provide Final prior to CO. | |||
| PLFM | HOLD | 12/06/2021 | 12/06/2021 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM A9 is missing the square footage of the garage. B1 is missing the Community Number. | |||
| BLD | COMPLETE | 11/02/2021 | 11/02/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/28/2021 | 10/29/2021 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/06/2021 | 10/07/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/06/2021 | 10/07/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/14/2021 | 07/20/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/03/2021 | 06/10/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/04/2021 | 05/11/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/26/2021 | 04/28/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/26/2021 | 05/03/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment: 3. Provide Product approval per F.S. 553.842. a. Soffits, Note : Submitted FL 24161.1 for soffitts cannot be found on FL Product Approval Listing. Please verify the FL Number. | |||
| MECH | HOLD | 04/16/2021 | 04/19/2021 |
| Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 insulation in attic and R4.1 on block walls. Energy calcs say R21 on roof deck and R5 on block walls. Revise to match. Revise details plan sheet to match the energy calcs or revise energy calcs. If Energy Calcs are correct then also change details plan to show non vented soffit | |||
| PLFM | COMPLETE | 04/16/2021 | 04/16/2021 |
| Note: Released By: JORDAN MYERS - (904)562-0045 - JMYERS@PALMCOASTGOV.COM The Construction elevation certificate has been accepted. Please provide Foundation and Final prior to receiving CO. | |||
| ZON | COMPLETE | 04/16/2021 | 04/16/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/16/2021 | 04/19/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 04/16/2021 | 04/20/2021 |
| Note: Released By: BARBIE BEMBRY - - BUILDINGDIVISION@PALMCOASTGOV.COM Plumbing review no longer required. All items in plumbing code will checked in the field by the inspector. | |||
| BLD | HOLD | 04/16/2021 | 04/21/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment: 3. Provide Product approval per F.S. 553.842. a. Soffits, Note : Submitted FL 415-0229 cannot be found on FL Product Approval Listing. Please verify the FL Number. | |||
| MECH | HOLD | 04/06/2021 | 04/07/2021 |
| Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 insulation in attic and R4.1 on block walls. Energy calcs say R21 on roof deck and R5 on block walls. Revise to match. (Second Request) | |||
| ELEC | HOLD | 04/06/2021 | 04/08/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM outlets in kitchen area and bathroom area need to be GFCI. NEC 2017 210.8 | |||
| PLFM | HOLD | 04/06/2021 | 04/07/2021 |
| Note: Held By: JORDAN MYERS - (904)562-0045 - JMYERS@PALMCOASTGOV.COM Please note the type of equipment from C2e in the comments area of Section D. There must be a signature and date on top of the seal in the box in Section D as well as in the signature box. | |||
| ZON | HOLD | 04/06/2021 | 04/07/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Additional shrub required on left side to total four along side No new landscape plan submitted | |||
| PLUM | HOLD | 04/06/2021 | 04/13/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comments: 1. Sanitary riser diagram at first floor: All refernces are 2020 FBCP 7th Edition. a. Provide complete vent sizes of fixture drains serving laundry room and bathroom suite 2 - Secs. 901.2/901.2.1. Also, indicate discharge location and main vent size in accordance with the total drainage fixture units -Table 710.1(2). b. Washing machine at laundry room shall vented - Sec. 905.4. 2. Sanitary riser diagram at second floor: a. Provide vent for kitchen sink fixture drain - Secs.901.2/901.2.1. b. Vent size of 2 inches of soil stack through the roof serving master bathroomm and its adjacent bathroom (great room bathroom ) does not comply with the required total dainage fixture units - Table 710.1(2). | |||
| BLD | HOLD | 04/06/2021 | 04/06/2021 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENT NO. 3 FROM PREVIOUS REVIEW HOLD ASKING FOR A ROOF FRAMING PLAN HAS BEEN REMOVED AS THE ROOF FRAMING PLAN WAS REQUESTED TO BE A DEFERRED SUBMITTAL. PLEASE RESPOND TO REMAINING REVIEW COMMENTS BELOW. THANK YOU. 1. First Floor: a. Typical Spiral Detail- refers to manufacturer's specificaion and details - cannot be found. Please provide. 2. Second floor: a. Gas burning fire place - provide manufacturer's specification and installation instructions per FBCR 7th Ed. Sec. R1004. b. Typical Guard Detail:- shall be designed to resist a concentrated load of 200 lbs per FBCB 7h Ed. Sec. 1607.8.1.1. 3. Provide Product approval per F.S. 553.842. a. Soffits, structural components such as wood connectors, wood anchors, truss plates and lintels. b. Provide roofing underlayment on Roofing Worksheet. Please note that there are significant 2020 Code Changes on roof covering material and roof undelaymen per FBCR 7th Ed. Sec. R905.1.1 or per FBCB 7th Ed. Sec. 1507.1.1.1. | |||
| BLD | HOLD | 04/06/2021 | 04/13/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comments: 1. First Floor: a. Typical Spiral Detail- refers to manufacturer's specification and details - cannot be found. Please provide. 2. Second floor: a. Gas burning fire place - provide manufacturer's specification and installation instructions per FBCR 7th Ed. Sec. R1004. b. Typical Guard Detail:- shall be designed to resist a concentrated load of 200 lbs per FBCB 7h Ed. Sec. 1607.8.1.1. 3. Provide Product approval per F.S. 553.842. a. Soffits, structural components such as wood connectors, wood anchors, truss plates and lintels. | |||
| ENGIN1 | COMPLETE | 04/06/2021 | 04/07/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US | |||
| SW1 | COMPLETE | 04/06/2021 | 04/12/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| PLFM | HOLD | 03/16/2021 | 03/16/2021 |
| Note: Held By: JORDAN MYERS - (386)986-2320 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted, the structure will fall inside the Special Flood Hazard Area. Elevation Certificates will be required at construction drawings, foundation, and final. | |||
| SWALE | COMPLETE | 03/15/2021 | 06/10/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/12/2021 | 03/19/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us 1. First Floor: a. Typical Spiral Detail- refers to manufacturer's specificaion and details - cannot be found. Please provide. 2. Second floor: a. Gas burning fire place - provide manufacturer's specification and installation instructions per FBCR 7th Ed. Sec. R1004. b. Typical Guard Detail:- shall be designed to resist a concentrated load of 200 lbs per FBCB 7h Ed. Sec. 1607.8.1.1. 3. Provide roof framing layout per FBCR 7th Ed. Sec 801/801.2. 4. Provide Product approval per F.S. 553.842. a. Soffits, structural components such as wood connectors, wood anchors, truss plates and lintels. b. Provide roofing underlayment on Roofing Worksheet. Please note that there are significant 2020 Code Changes on roof covering material and roof undelaymen per FBCR 7th Ed. Sec. R905.1.1 or per FBCB 7th Ed. Sec. 1507.1.1.1. | |||
| CUSVC | COMPLETE | 03/12/2021 | 03/19/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 03/12/2021 | 03/15/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outlets in kitchen area and bathroom area need to be GFCI. NEC 2017 210.8 | |||
| ENGIN1 | COMPLETE | 03/12/2021 | 03/15/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US | |||
| LOCATE | COMPLETE | 03/12/2021 | 03/18/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/12/2021 | 03/15/2021 |
| Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 insulation in attic and R4.1 on block walls. Energy calcs say R21 on roof deck and R5 on block walls. Revise to match. 2. Energy Calcs need to be signed by the builder | |||
| PLUM | HOLD | 03/12/2021 | 03/19/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us 1. Sanitary riser diagram at first floor: All refernces are 2020 FBCP 7th Edition. a. Provide complete vent sizes of fixture drains serving laundry room and bathroom suite 2 - Secs. 901.2/901.2.1. Also, indicate discharge location and main vent size in accordance with the total drainage fixture units -Table 710.1(2). b. Washing machine at laundry room shall vented - Sec. 905.4. 2. Sanitary riser diagram at second floor: a. Provide vent for kitchen sink fixture drain - Secs.901.2/901.2.1. b. Vent size of 2 inches of soil stack through the roof serving master bathroomm and its adjacent bathroom (great room bathroom ) does not comply with the required total dainage fixture units - Table 710.1(2). | |||
| SW1 | COMPLETE | 03/12/2021 | 03/19/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/12/2021 | 03/16/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Please demonstrate that the house does not exceed the maximum building height of 35ft Please show height,material of privacy wall and that it will match house Survey/site plan missing total lot square footage Survey notes missing the AE flood zone Survey/site plan states 1 story but house plans show 2 story Driveway turnaround must be labeled on survey/site plan and provide the dimensions. A turnaround can not exceed 9ft in width and 18ft in length Please show front entry walkway width and material on site plan survey Please show front setback from the front entry Additional shrub required on left side to total four along side |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 12/11/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/11/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/11/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/11/2023 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 12/11/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/11/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/11/2023 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/11/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤94.17) | 05/11/2021 |
| SEWER INSPECTION | ¤25.00 | 05/11/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 05/11/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 05/11/2021 |
| METER - DEPOSIT | ¤60.00 | 05/11/2021 |
| WATER- TURN ON | ¤25.00 | 05/11/2021 |
| ADMIN FEE | ¤20.00 | 05/11/2021 |
| IMPACT FEE TRANSPORTATION | ¤3,139.00 | 05/11/2021 |
| MECHANICAL FEE | ¤407.40 | 05/11/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/11/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 05/11/2021 |
| PLAN CHECK FEE | ¤231.60 | 05/11/2021 |
| PLUMBING FEE | ¤407.40 | 05/11/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤1,158.00 | 05/11/2021 |
| SITE PLAN 20 | ¤20.00 | 05/11/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/11/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/11/2021 |
| CONNECTION FEES | ¤1,017.83 | 05/11/2021 |
| BUILDING DISCOUNT 100% | (¤2,631.80) | 05/11/2021 |
| ELECTRIC FEE | ¤407.40 | 05/11/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 05/11/2021 |
| IMPACT FEE FIRE | ¤367.00 | 05/11/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 05/11/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/11/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,891.30 |