I want to search for...

Permit #2021031098

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-01080-0280
CONDITIONED SPACE: 2517 sqft
GARAGE: 484 sqft
OPENED PORCH (WITH ROOF) : 380 sqft
OPENED PORCH (WITH ROOF) : 146 sqft
Total Square Footage: 3527 sqft
Block: 01080
Subdivision: 2172 - SECTION 35-BELLE TERRE
Job Phone: 386-447-7007
Location Address: 265 BIRD OF PARADISE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/17/2021
NOC: RECORDED
Applicant name: MAXIM TARANNIK
Owner: STEVENS CHRISTOPHER & ANNE H&W

Address

9A BUNKER KNOLLS LANE

PALM COAST, FL 32137

Lot: 0280
Contracted Stated Job Value: ¤356,900.00
Job Description: single family residence
Type: CN

Contractor

GOLDEN MAGNOLIA, INC
Status Location Address State License Number Phone
INACTIVE

1 ROCKEFELLER DRIVE

PALM COAST, FL 32164

RR282811984 (Exp: 08/31/2025) 386-447-7007

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 12/13/2022 FINAL APPROVED EMADISON
Note: 12/9/2022 - PREVIOUS INSPECTION NOTES ** 12/09/22 SOD IS NEEDED ALONG DRIVEWAY EDGE TO PREVENT EROSION AND UNDERMINING OF DRIVEWAY ** CULVERT ENDS NEED TO BE CLKEANED OUT OF ALL DEBRIS 12/2/2022 - PREVIOUS INSPECTION NOTES ** 12/02/22 ALL CONSTRUCTION MATERIAL AND DEBRIS ALONG WITH ALL TRASH NEEDS TO BE REMOVED FROM ENTIRE PROPERTY INCLUDING THE NATURAL AREA AT REAR OF PROPERTY. ** SOD REQUIRED LEFT REAR CORNER OF HOUSE NEAR FENCE MARKED WITH WHITE PAINT ALSO NEED TO FILL IN HOLE AT CORNER OF FENCE WHERE PROPERTY STEAK IS IN GROUND **SOD REQUIRED ALONG BOTH SIDES OF THE DRIVEWAY TO PREVENT EROSION AND UNDERMINING. ** SOD OR STONE NEEDED AROUND THE ENTIRE SCREEN ENCLOSURE TO PREVENT EROSION AND UNDERMINING ** REAR SWALE NEEDS TO BE SODDED TO TOP OF ROW (RIGHT OF WAY) ** REMOVE PIPE AT REAR OF PROPERTY
ROW - FINAL INSPECTION 12/09/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 12/09/22 SOD IS NEEDED ALONG DRIVEWAY EDGE TO PREVENT EROSION AND UNDERMINING OF DRIVEWAY ** CULVERT ENDS NEED TO BE CLKEANED OUT OF ALL DEBRIS 12/2/2022 - PREVIOUS INSPECTION NOTES ** 12/02/22 ALL CONSTRUCTION MATERIAL AND DEBRIS ALONG WITH ALL TRASH NEEDS TO BE REMOVED FROM ENTIRE PROPERTY INCLUDING THE NATURAL AREA AT REAR OF PROPERTY. ** SOD REQUIRED LEFT REAR CORNER OF HOUSE NEAR FENCE MARKED WITH WHITE PAINT ALSO NEED TO FILL IN HOLE AT CORNER OF FENCE WHERE PROPERTY STEAK IS IN GROUND **SOD REQUIRED ALONG BOTH SIDES OF THE DRIVEWAY TO PREVENT EROSION AND UNDERMINING. ** SOD OR STONE NEEDED AROUND THE ENTIRE SCREEN ENCLOSURE TO PREVENT EROSION AND UNDERMINING ** REAR SWALE NEEDS TO BE SODDED TO TOP OF ROW (RIGHT OF WAY) ** REMOVE PIPE AT REAR OF PROPERTY
ROW - DRAINAGE 12/08/2022 APPROVED EMADISON
Note: ** 12/08/22 CORRECTIONS HAVE BEEN MADE 12/7/2022 - PREVIOUS INSPECTION NOTES 12/07/22=NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE ________________________________________________________________________________________________________________________ 12/6/2022 - PREVIOUS INSPECTION NOTES 12/06/22= SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE INSPECTOR BE BACK 12/07/22 ________________________________________________________________________________________________________________________ 12/5/2022 - PREVIOUS INSPECTION NOTES ** 12/05/22 NO CORRECTIONS MADE ** SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/06/22 12/2/2022 - PREVIOUS INSPECTION NOTES ** 12/02/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/05/22 12/1/2022 - PREVIOUS INSPECTION NOTES ** 12/01/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. ** FOLLOW UP INSPECTION ON 12/02/22 9/26/2022 - PREVIOUS INSPECTION NOTES ** 09/26/22 NO CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECT ** SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP ISPECTION ON 09/27/22 9/23/2022 - PREVIOUS INSPECTION NOTES ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW - DRAINAGE 12/07/2022 Disapproved -FEE REQUIRED GBERTOLA
Note: 12/07/22=NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE ________________________________________________________________________________________________________________________ 12/6/2022 - PREVIOUS INSPECTION NOTES 12/06/22= SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE INSPECTOR BE BACK 12/07/22 ________________________________________________________________________________________________________________________ 12/5/2022 - PREVIOUS INSPECTION NOTES ** 12/05/22 NO CORRECTIONS MADE ** SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/06/22 12/2/2022 - PREVIOUS INSPECTION NOTES ** 12/02/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/05/22 12/1/2022 - PREVIOUS INSPECTION NOTES ** 12/01/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. ** FOLLOW UP INSPECTION ON 12/02/22 9/26/2022 - PREVIOUS INSPECTION NOTES ** 09/26/22 NO CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECT ** SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP ISPECTION ON 09/27/22 9/23/2022 - PREVIOUS INSPECTION NOTES ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW - DRAINAGE 12/06/2022 Disapproved -FEE REQUIRED GBERTOLA
Note: 12/06/22= SWALE DAMAGE NEED TO BE COMPLETELY REPAIR AND RE-SOD. ALL RUTTS AND BARE SPOTS MUST BE FILLED AND SODDED, NOT SEEDED OR COVERED W/STRAW AND/OR PINE NEEDLE INSPECTOR BE BACK 12/07/22 ________________________________________________________________________________________________________________________ 12/5/2022 - PREVIOUS INSPECTION NOTES ** 12/05/22 NO CORRECTIONS MADE ** SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/06/22 12/2/2022 - PREVIOUS INSPECTION NOTES ** 12/02/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/05/22 12/1/2022 - PREVIOUS INSPECTION NOTES ** 12/01/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. ** FOLLOW UP INSPECTION ON 12/02/22 9/26/2022 - PREVIOUS INSPECTION NOTES ** 09/26/22 NO CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECT ** SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP ISPECTION ON 09/27/22 9/23/2022 - PREVIOUS INSPECTION NOTES ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW - DRAINAGE 12/05/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 12/05/22 NO CORRECTIONS MADE ** SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/06/22 12/2/2022 - PREVIOUS INSPECTION NOTES ** 12/02/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/05/22 12/1/2022 - PREVIOUS INSPECTION NOTES ** 12/01/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. ** FOLLOW UP INSPECTION ON 12/02/22 9/26/2022 - PREVIOUS INSPECTION NOTES ** 09/26/22 NO CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECT ** SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP ISPECTION ON 09/27/22 9/23/2022 - PREVIOUS INSPECTION NOTES ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
BLD - BUILDING FINAL 12/05/2022 FINAL APPROVED DCUSHING
Note: 12/1/2022 - PREVIOUS INSPECTION NOTES 1. Stucco damaged above A/C disconnect 2. Ufer ground missing cov er 3. All left over construction materials must be removed before final 4. Weather stripping missing at front door ALL ITEMS ADDRESSED Stopped inspection @ front door
ROW - FINAL APRON (AFTER POUR) 12/02/2022 FINAL APPROVED EMADISON
ROW - DRAINAGE 12/02/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 12/01/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. TO THE NTOP OF ROW (RIGHT OF WAY) ** FOLLOW UP INSPECTION ON 12/02/22 12/1/2022 - PREVIOUS INSPECTION NOTES ** 12/01/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. ** FOLLOW UP INSPECTION ON 12/02/22 9/26/2022 - PREVIOUS INSPECTION NOTES ** 09/26/22 NO CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECT ** SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP ISPECTION ON 09/27/22 9/23/2022 - PREVIOUS INSPECTION NOTES ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW FIELD SURVEY /GRADING CERTIFICATION 12/02/2022 APPROVED EMADISON
Note: ** 12/02/22 ALL CONSTRUCTION MATERIAL AND DEBRIS ALONG WITH ALL TRASH NEEDS TO BE REMOVED FROM ENTIRE PROPERTY INCLUDING THE NATURAL AREA AT REAR OF PROPERTY. ** SOD REQUIRED LEFT REAR CORNER OF HOUSE NEAR FENCE MARKED WITH WHITE PAINT ALSO NEED TO FILL IN HOLE AT CORNER OF FENCE WHERE PROPERTY STEAK IS IN GROUND **SOD REQUIRED ALONG BOTH SIDES OF THE DRIVEWAY TO PREVENT EROSION AND UNDERMINING. ** SOD OR STONE NEEDED AROUND THE ENTIRE SCREEN ENCLOSURE TO PREVENT EROSION AND UNDERMINING ** REAR SWALE NEEDS TO BE SODDED TO TOP OF ROW (RIGHT OF WAY) ** REMOVE PIPE AT REAR OF PROPERTY
ROW - FINAL INSPECTION 12/02/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 12/02/22 ALL CONSTRUCTION MATERIAL AND DEBRIS ALONG WITH ALL TRASH NEEDS TO BE REMOVED FROM ENTIRE PROPERTY INCLUDING THE NATURAL AREA AT REAR OF PROPERTY. ** SOD REQUIRED LEFT REAR CORNER OF HOUSE NEAR FENCE MARKED WITH WHITE PAINT ALSO NEED TO FILL IN HOLE AT CORNER OF FENCE WHERE PROPERTY STEAK IS IN GROUND **SOD REQUIRED ALONG BOTH SIDES OF THE DRIVEWAY TO PREVENT EROSION AND UNDERMINING. ** SOD OR STONE NEEDED AROUND THE ENTIRE SCREEN ENCLOSURE TO PREVENT EROSION AND UNDERMINING ** REAR SWALE NEEDS TO BE SODDED TO TOP OF ROW (RIGHT OF WAY) ** REMOVE PIPE AT REAR OF PROPERTY
ROW - STORMWATER FINAL 12/01/2022 CANCELLED BY INSPECTOR EMADISON
U -UTILITY RESIDENTIAL FINAL 12/01/2022 FINAL APPROVED DHANEY
ROW FIELD SURVEY /GRADING CERTIFICATION 12/01/2022 CANCELLED BY INSPECTOR EMADISON
ROW - DRAINAGE 12/01/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 12/01/22 SWALE ON BACK SIDE OF PROPERTY NEEDS TO BE SODDED WHERE ALL BARE AREAS OS EARTH ARE. ** FOLLOW UP INSPECTION ON 12/01/22 9/26/2022 - PREVIOUS INSPECTION NOTES ** 09/26/22 NO CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECT ** SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP ISPECTION ON 09/27/22 9/23/2022 - PREVIOUS INSPECTION NOTES ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW - FINAL APRON (AFTER POUR) 12/01/2022 CANCELLED BY INSPECTOR EMADISON
BLD - BUILDING FINAL 12/01/2022 Disapproved - NO FEE MKRASKI
Note: 1. Stucco damaged above A/C disconnect 2. Ufer ground missing cov er 3. All left over construction materials must be removed before final 4. Weather stripping missing at front door Stopped inspection @ front door
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/30/2022 APPROVED EMADISON
Note: ** 11/30/22 CORRECTIONS MADE 11/15/2022 - PREVIOUS INSPECTION NOTES ** 11/15/22 YOUR FINAL SURVEY DOES NOT HAVE THE 10 FOOT OFFSET ELEVATION SHOTS FOR THE ADJACENT PROPERTIES ** MISSING YOUR FINISHED FLOOR ELEVATION, AND FINISHED FLOOR ELEVATION OF THE ADJACENT PROPERTY THIS IS A REINSPECTION THIS IS A REINSPECTION ** 09/09/22 YOUE REVISED SITE PLANE ON FILE AND FINAL SURVEY DO NOT FOLLOW THE SAME PROPOSED LOT DRAINAGE. THIS IS A REINSPECTION ** 08/31/22 ST5ILL MISSING PROPERTY LINE ELEVATIONS FOR ADJACENT LOTS STILL MISSING THE CENTER LINE (CROWN OF ROAD) ELEVATIONS TO DETERMINE THAT THE FINISHED FLOOR ELEVATION IS A MINIMUM OF 1 FT HIGHER THAN THE CENTER LINE OF ROAD (CROWN OF ROAD) THIS IS A REINSPECTION 8/26/22 - Crown of the road elevations are missing to determine that the FFE is a minimum of 12 inches above the crown. ** 08/17/22 THERE ARE NO PROPERTY ELEVATIONS ON ADJACENT PROPERTIES ON LEFT SIDE 10 FEET OFF PROPERTY LINE. NEED TO UPDATE FINAL SURVEY ** REVISED SITE PLAN AND FINAL SURVEY DRAINAGE DO NOT MATCH THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22. 7/15/22 - Temporary Culvert removed and swale regraded and pending new sod for the Final Stormwater Inspection.
ROW FIELD SURVEY /GRADING CERTIFICATION 11/30/2022 CANCELLED BY INSPECTOR EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/15/2022 Disapproved - NO FEE EMADISON
Note: ** 11/15/22 YOUR FINAL SURVEY DOES NOT HAVE THE 10 FOOT OFFSET ELEVATION SHOTS FOR THE ADJACENT PROPERTIES ** MISSING YOUR FINISHED FLOOR ELEVATION, AND FINISHED FLOOR ELEVATION OF THE ADJACENT PROPERTY THIS IS A REINSPECTION THIS IS A REINSPECTION ** 09/09/22 YOUE REVISED SITE PLANE ON FILE AND FINAL SURVEY DO NOT FOLLOW THE SAME PROPOSED LOT DRAINAGE. THIS IS A REINSPECTION ** 08/31/22 ST5ILL MISSING PROPERTY LINE ELEVATIONS FOR ADJACENT LOTS STILL MISSING THE CENTER LINE (CROWN OF ROAD) ELEVATIONS TO DETERMINE THAT THE FINISHED FLOOR ELEVATION IS A MINIMUM OF 1 FT HIGHER THAN THE CENTER LINE OF ROAD (CROWN OF ROAD) THIS IS A REINSPECTION 8/26/22 - Crown of the road elevations are missing to determine that the FFE is a minimum of 12 inches above the crown. ** 08/17/22 THERE ARE NO PROPERTY ELEVATIONS ON ADJACENT PROPERTIES ON LEFT SIDE 10 FEET OFF PROPERTY LINE. NEED TO UPDATE FINAL SURVEY ** REVISED SITE PLAN AND FINAL SURVEY DRAINAGE DO NOT MATCH THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22. 7/15/22 - Temporary Culvert removed and swale regraded and pending new sod for the Final Stormwater Inspection.
ROW - DRAINAGE 09/26/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 09/26/22 NO CORRECTIONS HAVE BEEN MADE SINCE THE PREVIOUS INSPECT ** SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP ISPECTION ON 09/27/22 9/23/2022 - PREVIOUS INSPECTION NOTES ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP WITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW - DRAINAGE 09/23/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 09/23/22 SWALE DRAINAGE IN REAR OF PROPERTY ALONG BICKSHIRE IS TORE UP MWITH RUTS CAUSING A DISRUPTION WITH THE FLOW OF STORM WATER. IF THIS AREA IS USED AS ACESS TO THE PROPERTY A TEMPORARY NEEDS TO BE INSTALLED. ** FOLLOW UP INSPECTION ON 09/26/22 9/19/2022 - PREVIOUS INSPECTION NOTES ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW - DRAINAGE 09/19/2022 Disapproved - NO FEE EMADISON
Note: ** BUILDER NEEDS TO MOW AND REPAIR SWALE THAT BOARDERS BICKSHIRE LANE AT THE REAR OF THE CONSTRUCTION SITE PROPERTY. THE OVER GROWTH AND DAMAGE TO SWALE FROM EQUIPMENT IS BLOCKING THE FLOW OF THE DRAINAGE CONVEYANCE CAUSING STORMWATER TO BACK UP AND NAGATIVELY IMPACR THE THE ADJACENT PROPERTIES AND BEYOND AS WELL AS CAUSING WATER TO FLOOD ONTO THE ROADWAY. IF THE BUILDER HAS ANY QUESTION CONTACT THE INSPECTOR FOR CLEARIFICATION. ** FOLOWM UP INSPECTION ON 09/23/22
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/09/2022 Disapproved - NO FEE EMADISON
Note: THIS IS A REINSPECTION ** 09/09/22 YOUE REVISED SITE PLANE ON FILE AND FINAL SURVEY DO NOT FOLLOW THE SAME PROPOSED LOT DRAINAGE. THIS IS A REINSPECTION ** 08/31/22 ST5ILL MISSING PROPERTY LINE ELEVATIONS FOR ADJACENT LOTS STILL MISSING THE CENTER LINE (CROWN OF ROAD) ELEVATIONS TO DETERMINE THAT THE FINISHED FLOOR ELEVATION IS A MINIMUM OF 1 FT HIGHER THAN THE CENTER LINE OF ROAD (CROWN OF ROAD) THIS IS A REINSPECTION 8/26/22 - Crown of the road elevations are missing to determine that the FFE is a minimum of 12 inches above the crown. ** 08/17/22 THERE ARE NO PROPERTY ELEVATIONS ON ADJACENT PROPERTIES ON LEFT SIDE 10 FEET OFF PROPERTY LINE. NEED TO UPDATE FINAL SURVEY ** REVISED SITE PLAN AND FINAL SURVEY DRAINAGE DO NOT MATCH THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22. 7/15/22 - Temporary Culvert removed and swale regraded and pending new sod for the Final Stormwater Inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/31/2022 Disapproved -FEE REQUIRED EMADISON
Note: THIS IS A REINSPECTION ** 08/31/22 ST5ILL MISSING PROPERTY LINE ELEVATIONS FOR ADJACENT LOTS STILL MISSING THE CENTER LINE (CROWN OF ROAD) ELEVATIONS TO DETERMINE THAT THE FINISHED FLOOR ELEVATION IS A MINIMUM OF 1 FT HIGHER THAN THE CENTER LINE OF ROAD (CROWN OF ROAD) THIS IS A REINSPECTION 8/26/22 - Crown of the road elevations are missing to determine that the FFE is a minimum of 12 inches above the crown. ** 08/17/22 THERE ARE NO PROPERTY ELEVATIONS ON ADJACENT PROPERTIES ON LEFT SIDE 10 FEET OFF PROPERTY LINE. NEED TO UPDATE FINAL SURVEY ** REVISED SITE PLAN AND FINAL SURVEY DRAINAGE DO NOT MATCH THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22. 7/15/22 - Temporary Culvert removed and swale regraded and pending new sod for the Final Stormwater Inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/26/2022 Disapproved - NO FEE RGROSS
Note: THIS IS A REINSPECTION 8/26/22 - Crown of the road elevations are missing to determine that the FFE is a minimum of 12 inches above the crown. ** 08/17/22 THERE ARE NO PROPERTY ELEVATIONS ON ADJACENT PROPERTIES ON LEFT SIDE 10 FEET OFF PROPERTY LINE. NEED TO UPDATE FINAL SURVEY ** REVISED SITE PLAN AND FINAL SURVEY DRAINAGE DO NOT MATCH THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22. 7/15/22 - Temporary Culvert removed and swale regraded and pending new sod for the Final Stormwater Inspection.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/17/2022 Disapproved - NO FEE EMADISON
Note: ** 08/17/22 THERE ARE NO PROPERTY ELEVATIONS ON ADJACENT PROPERTIES ON LEFT SIDE 10 FEET OFF PROPERTY LINE. NEED TO UPDATE FINAL SURVEY ** REVISED SITE PLAN AND FINAL SURVEY DRAINAGE DO NOT MATCH THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22. 7/15/22 - Temporary Culvert removed and swale regraded and pending new sod for the Final Stormwater Inspection.
ROW - DRAINAGE 07/15/2022 Disapproved -FEE REQUIRED RGROSS
Note: ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22.
ROW - DRAINAGE 07/15/2022 APPROVED - AS NOTED RGROSS
Note: THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS ) 7/12/22 - Temporary Culvert pipe at 34 Bickshire connected to this building lot needs to allow for drainage. Partially clogged. Next Inspection. 7/15/22. 7/15/22 - Temporary Culvert removed and swale regraded and pending new sod for the Final Stormwater Inspection.
ROW - DRAINAGE 07/12/2022 CANCELLED BY INSPECTOR EMADISON
Note: THIS IS A REINSPECTION ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS )
ROW - DRAINAGE 07/11/2022 Disapproved - NO FEE EMADISON
Note: ** TEMPORARY CULVERT PIPE LOCATED AT 34 BICKSHIRE LN IS 95% BLOCKED NOT ALLOWING STORM WATER TO DRAIN ALONG BICKSHIRE LN THIS BLOCKAGE IS HAVING A NEGATIVE IMPACT ON THE ADJACENT PROPERTY AND OTHER UPSTREAM PROPERTIES. SWALE ALSO NEEDS TO BE OPENED UP TO THE DITCH. ** FOLLOW UP INSPECTION ON 07/15/22 ( SEE ATTACHED PHOTOS )
U-CROSS CONNECTION 06/13/2022 APPROVED - AS NOTED DHANEY
Note: Yard/IRR. not installed yet, no cross cn. .
ROW- PRE-APRON (PRE-POUR) 06/10/2022 APPROVED - AS NOTED EMADISON
Note: ** AT THE TIME OF THE INSPECTION EVERYTHING LOOKS GOOD READY TO POUR IN THE EVENT OF RAIN BUILDER NEEDS TO RECHECK ELEVATIONS / ENSURE ITS NOT TO WET. ** TOO MANY HIGH SPOTS THROUGHOUT DRIVEWAY POUR AREA NEED TO REGRADE DRIVEWAY TAKE OUT HIGH SPOTS TO ENSURE A MINIMUM OF 4" OF CONCRETE. ** NOTE TO INSPECTOR PIPE WAS WITHIN TOLERANCES AT TIME OF INSPECTION BUT WILL RESHOOT ELEVATIONS ON THE NEXT INSPECTION
ROW- PRE-APRON (PRE-POUR) 06/09/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** TOO MANY HIGH SPOTS THROUGHOUT DRIVEWAY POUR AREA NEED TO REGRADE DRIVEWAY TAKE OUT HIGH SPOTS TO ENSURE A MINIMUM OF 4" OF CONCRETE. ** NOTE TO INSPECTOR PIPE WAS WITHIN TOLERANCES AT TIME OF INSPECTION BUT WILL RESHOOT ELEVATIONS ON THE NEXT INSPECTION
ELECTRIC - EARLY POWER 06/06/2022 APPROVED - AS NOTED RMARTIN
Note: NEED TO STRAP SERVICE CONDUIT BY FINAL, EMAILED FPL RELEASED POWER 10:30
GRAVITY SEWER TEST 05/27/2022 APPROVED MGIBSON
U - SEWER TIE IN 05/26/2022 APPROVED - AS NOTED MGIBSON
Note: NEED TO CALL INSPECTION FOR GRAVITY SEWER AS WELL TOMMORROW
ELECTRIC - EARLY POWER 05/19/2022 Disapproved - NO FEE MKRASKI
Note: Front window broken and must be sealed before power can be released
PEP TANK INSTALLATION REQUEST 04/29/2022 APPROVED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 4/26/2022 11:54:56 AM Exterior (stucco or siding) EMAIL RHAND@PALMCOASTGOV.COM WITH QUESTIONS
PEP TANK INSTALLATION REQUEST 04/26/2022 Disapproved - NO FEE CSTONE
Note: Exterior (stucco or siding) EMAIL RHAND@PALMCOASTGOV.COM WITH QUESTIONS
LATH/BRICK/ WATER BARRIER 04/19/2022 APPROVED FWILLIS
INSULATION 04/07/2022 APPROVED FWILLIS
PEP TANK INSTALLATION REQUEST 04/07/2022 CANCELLED BY APPLICANT WEB
ALL ROUGH 04/05/2022 APPROVED KSANDOE
Note: New inspection due to canceled inspection THIS IS A REINSPECTION 1. Missing front door 2. missing 2 side doors 3. missing 3 windows plus one broken one 4. No 5' head pressure present 5. Top firn strip missing in dinning 6. Plumbing not sealed at floor OK to spray foam roof decking per Robert
ALL ROUGH 03/23/2022 CANCELLED BY APPLICANT WEB
Note: THIS IS A REINSPECTION 1. Missing front door 2. missing 2 side doors 3. missing 3 windows plus one broken one 4. No 5' head pressure present 5. Top firn strip missing in dinning 6. Plumbing not sealed at floor OK to spray foam roof decking per Robert
ALL ROUGH 03/08/2022 Disapproved - NO FEE MKRASKI
Note: 1. Missing front door 2. missing 2 side doors 3. missing 3 windows plus one broken one 4. No 5' head pressure present 5. Top firn strip missing in dinning 6. Plumbing not sealed at floor OK to spray foam roof decking per Robert
ROOF VALLEY & METAL 02/22/2022 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/16/2022 APPROVED FWILLIS
Note: THIS IS A REINSPECTION Window Installers Installing windows throughout building. Material and equipment throughout on the floor. Multiple trip Hazards, Can not perform Inspection on framing and truss's effectively. Re-Schedule.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/11/2022 Disapproved - NO FEE FWILLIS
Note: Window Installers Installing windows throughout building. Material and equipment throughout on the floor. Multiple trip Hazards, Can not perform Inspection on framing and truss's effectively. Re-Schedule.
TIE BEAM / LINTEL 01/04/2022 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 12/01/2021 APPROVED TBAKER
MONOLITHIC SLAB 11/04/2021 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 10/26/2021 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/15/2021 APPROVED CSTONE
WATER METER INSTALLATION REQUEST 09/14/2021 CANCELLED BY APPLICANT WEB

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 06/01/2022 06/01/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/01/2022 06/07/2022
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ZON COMPLETE 06/01/2022 06/01/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/01/2021 12/01/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/01/2021 12/01/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 08/13/2021 08/13/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON HOLD 08/12/2021 08/12/2021
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Front setback covered up. Please make sure all setbacks are clearly visible for review.
ENGIN1 COMPLETE 08/12/2021 08/12/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/12/2021 08/13/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
SW1 COMPLETE 08/06/2021 08/12/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
BLD COMPLETE 08/06/2021 08/09/2021
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ELEC COMPLETE 08/06/2021 08/09/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 CANCEL 08/06/2021 08/06/2021
Note: duplicate
ZON HOLD 08/06/2021 08/09/2021
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM There is a 20ft easement on the right side. Concrete pad and AC can not be located in the easement
SW1 HOLD 07/28/2021 07/28/2021
Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) The lot on Bird of Paradise Dr is going to the front moving the water front the front to the back. The other lot on Bickshire is going from back to front need to make a berm in between both properties
ENGIN1 COMPLETE 07/21/2021 07/21/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/21/2021 07/21/2021
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 06/11/2021 06/11/2021
Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM Site plant to confuse need to resubmitt a plan that does not show all the trees we do not need to see this.
ENGIN1 COMPLETE 04/29/2021 04/29/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/29/2021 04/29/2021
Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM
SW1 HOLD 04/29/2021 05/05/2021
Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Drainage should drain to the front in this case and it needs to have a common swale.
SWALE COMPLETE 04/29/2021 05/27/2021
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ENGIN1 HOLD 03/29/2021 03/29/2021
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US Cannot see benchmark elevation on survey. Survey elevations must be to the nearest hundredth of a foot.
ELEC COMPLETE 03/29/2021 03/29/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 03/29/2021 03/31/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Lot numbers are incorrect on site plan/survey. Should be lot 1 and 28 Site plan must show the material and width of driveway and front entry walkway Site plan must show rear setback from house to property line of lot 28 only. Easement is not released so must meet the setbacks for the lot the house is on. Can not release the easement until it is being built across
BLD COMPLETE 03/29/2021 03/29/2021
Note: Released By: JPI
SW1 HOLD 03/29/2021 04/06/2021
Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM This is a boundary survey not a topographical site plan that shows drainage or elevations on the lot or a proposed drainage conveyance please correct this and resubmitt a plan that does not show all the trees we do not need to see this.
SW1 HOLD 03/24/2021 03/24/2021
Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM PLEASE REMOVE THE LAYER FOR THE TREES See uploaded Stormwater checklist in attachments for correction. Make corrections on all unchecked items.
ZON HOLD 03/17/2021 03/23/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM On Floor plan labels are missing for bedroom 4,bath 3 and area by the garage Lot numbers are incorrect on site plan/survey. Should be lot 1 and 28 Landscape plan must specify and have marked the trees you are keeping as well as what you are adding to total 10 required trees Foundation plantings required along rear foundation since this backs to a street Site plan must show the material and width of driveway and front entry walkway Site plan must show rear setback from house to property line of lot 28 only. Easement is not released so must meet the setbacks for the lot the house is on. Can not release the easement until it is being built across
BLD HOLD 03/17/2021 03/23/2021
Note: Held By: JPI 1. Product approval indicates same number for soffit and shingles.
CUSVC COMPLETE 03/17/2021 03/22/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 03/17/2021 03/18/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM If installing a generator need to submit a riser diagram for the generator and manufactured specs.
ENGIN1 HOLD 03/17/2021 03/17/2021
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US Cannot read benchmark elevations on survey
LOCATE COMPLETE 03/17/2021 03/19/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 03/17/2021 03/18/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 03/17/2021 03/23/2021
Note: Released By: JPI

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG - INSPECTION 20 ¤20.00 12/13/2022
SW ENG REINSPECTION 20 ¤20.00 12/13/2022
SW ENG REINSPECTION 20 ¤20.00 12/13/2022
SW ENG REINSPECTION 30 ¤30.00 12/13/2022
CONTRACTOR CHANGE ¤40.00 02/07/2022
CONTRACTOR CHANGE ¤40.00 02/07/2022
CONTRACTOR CHANGE ¤40.00 09/29/2021
CONTRACTOR CHANGE ¤40.00 09/29/2021
BUILDING DISCOUNT 100% (¤1,699.40) 08/17/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 08/17/2021
IMPACT FEE FIRE ¤367.00 08/17/2021
IMPACT FEE PARKS ¤1,199.12 08/17/2021
IMPACT FEE SCHOOL ¤3,600.00 08/17/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 08/17/2021
WATER -IRRIGATION INSPECTION ¤25.00 08/17/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 08/17/2021
NEW RESIDENTIAL INSPECTIONS ¤714.00 08/17/2021
SITE PLAN 20 ¤20.00 08/17/2021
SURCHARGE FS 533.721 ¤2.00 08/17/2021
SURCHARGE - FS 468.631 ¤2.00 08/17/2021
METER - DEPOSIT ¤60.00 08/17/2021
WATER- TURN ON ¤25.00 08/17/2021
ADMINISTRATIVE RESIDENTIAL ¤20.00 08/17/2021
INSPECTION- ELECTRICAL ¤274.20 08/17/2021
INSPECTION - MECHANICAL ¤274.20 08/17/2021
INSPECTION - PLUMBING ¤274.20 08/17/2021
PLAN REVIEW - RESIDENTIAL ¤142.80 08/17/2021
CONNECTION FEES ¤1,017.83 08/17/2021
STORM WATER PERMIT FEES ¤80.00 08/17/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 08/17/2021
SEWER CREDIT (¤850.00) 08/17/2021
SEWER INSPECTION ¤25.00 08/17/2021
SEWER CAPITAL FACILITY ¤4,664.55 08/17/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 08/17/2021
Fees Total Due: ¤0.00 Total Paid: ¤15,771.43