Permit #2021031474
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00240-0150 |
| CONDITIONED SPACE: 2001 sqft |
| GARAGE: 542 sqft |
| OPENED PORCH (WITH ROOF) : 410 sqft |
| OPENED PORCH (WITH ROOF) : 146 sqft |
| Total Square Footage: 3099 sqft |
| Block: 00240 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 386-447-7007 |
| Location Address: 22 WHITTIER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/24/2021 |
| NOC: RECORDED |
| Applicant name: MAXIM TARANNIK |
| Owner: GLIKIN DAVID |
|
Address 375 WILKINS DRIVE DES PLAINES, IL 60016 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤269,900.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
GOLDEN MAGNOLIA, INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1 ROCKEFELLER DRIVE PALM COAST, FL 32164 |
RR282811984 (Exp: 08/31/2025) | 386-447-7007 |
Sub Contractors
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/15/2023 | FINAL APPROVED | MKRASKI |
| BLD - BUILDING FINAL | 03/14/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/14/23 Door locked need access foe inspection , trash still not cleaned up outside stopped inspection. ake sure ALL items are fixed before re-inspection 3/10/2023 - PREVIOUS INSPECTION NOTES 3/10/23 All items need to be repaired before next inspection, also trash needs to be removed by electrical service meter 3/6/2023 - PREVIOUS INSPECTION NOTES 3/6/23 1. Back flow preventer missing tamper screw 2. Light on front not working properly 3. Master shower mixing valve hot and cold reversed 4. Can light in kitchen near pantry not operational 5. Dust covers need to be removed on smoke detectors before final 3/1/2023 - PREVIOUS INSPECTION NOTES 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection | |||
| BLD - BUILDING FINAL | 03/10/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/10/23 All items need to be repaired before next inspection, also trash needs to be removed by electrical service meter 3/6/2023 - PREVIOUS INSPECTION NOTES 3/6/23 1. Back flow preventer missing tamper screw 2. Light on front not working properly 3. Master shower mixing valve hot and cold reversed 4. Can light in kitchen near pantry not operational 5. Dust covers need to be removed on smoke detectors before final 3/1/2023 - PREVIOUS INSPECTION NOTES 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection | |||
| U -UTILITY RESIDENTIAL FINAL | 03/10/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: pep tank full-not drawing down? sent issue to Ivan at utility | |||
| BLD - BUILDING FINAL | 03/06/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/6/23 1. Back flow preventer missing tamper screw 2. Light on front not working properly 3. Master shower mixing valve hot and cold reversed 4. Can light in kitchen near pantry not operational 5. Dust covers need to be removed on smoke detectors before final 3/1/2023 - PREVIOUS INSPECTION NOTES 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection | |||
| BLD - BUILDING FINAL | 03/01/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection | |||
| U-CROSS CONNECTION | 03/01/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-no crossconnectio | |||
| ROW - STORMWATER FINAL | 02/28/2023 | APPROVED | GBERTOLA |
| Note: 2/28/23=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD builder will build a berm in the back | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/01/2023 | APPROVED | GBERTOLA |
| Note: Inspector Notes from Inspection 9200 | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/01/2023 | APPROVED | GBERTOLA |
| ROW - FINAL APRON (AFTER POUR) | 02/01/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| ROW- PROJECT STATUS | 01/31/2023 | APPROVED - AS NOTED | GBERTOLA |
| Note: still waiting for the phone call to set up time to meet at the location with max | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/24/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: YOUR DRAINAGE IS IMPACTING THE LOTS SURROUNDING YOURS | |||
| ROW- PROJECT STATUS | 12/14/2022 | APPROVED | GBERTOLA |
| Note: I TOOK A LOOK ON THE RE-GRADE | |||
| ROW- PROJECT STATUS | 12/08/2022 | APPROVED | GBERTOLA |
| Note: meeting with the cm David | |||
| ROW- PRE-APRON (PRE-POUR) | 10/17/2022 | APPROVED | GBERTOLA |
| Note: 10/17/22=AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ............................................................................................................................................................................................................................ 10/14/2022 - PREVIOUS INSPECTION NOTES ** 10/14/22 MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** 5" MINIMUM THICK CONCRETE REQUIRED IN THE APRON, RIGHT SIDE NEED FORM BOARDS RAISED. ** UPPER AREA OF DRIVEWAY OUTLINED HIGH SPOT IN PINK PAINT NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEWAY ABOVE ROW. ** CULVERT ELEVATION WAS GOOD AT THE TIME OF THIS INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 10/14/2022 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 10/14/22 MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** 5" MINIMUM THICK CONCRETE REQUIRED IN THE APRON, RIGHT SIDE NEED FORM BOARDS RAISED. ** UPPER AREA OF DRIVEWAY OUTLINED HIGH SPOT IN PINK PAINT NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEWAY ABOVE ROW. ** CULVERT ELEVATION WAS GOOD AT THE TIME OF THIS INSPECTION | |||
| U - SEWER TIE IN | 09/02/2022 | APPROVED | DCUSHING |
| GRAVITY SEWER TEST | 09/02/2022 | APPROVED | DCUSHING |
| ELECTRIC - EARLY POWER | 08/31/2022 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 12:25PM 8/31/22 | |||
| WINDOW NAILING | 08/11/2022 | APPROVED | MKRASKI |
| PEP TANK INSTALLATION REQUEST | 08/09/2022 | APPROVED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 7/25/2022 3:50:52 PM (stucco, stone, or siding must be applied) | |||
| PEP TANK INSTALLATION REQUEST | 07/21/2022 | Disapproved - NO FEE | TCHURCHILL |
| Note: (stucco, stone, or siding must be applied) | |||
| INSULATION | 07/18/2022 | APPROVED | MKRASKI |
| LATH/BRICK/ WATER BARRIER | 07/12/2022 | APPROVED | MKRASKI |
| ALL ROUGH | 03/21/2022 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Dryer vent and hood vent seams need to be sealed 2. No 5' head pressure 3. Spare bathroom tub needs to be sealed at floor 4. Kitchen floor needs rio be sealed in island Check on insulation | |||
| ALL ROUGH | 03/15/2022 | Disapproved - NO FEE | KSANDOE |
| Note: 1/28/22 Multiple trusses missing engineering. Marked on truss detail. Check at All Rough 3/15/22 - Trusses still missing engineering. Cannot spray foam insulation into trusses still missing bracing. Window nailing inspection addeed | |||
| ROOF VALLEY & METAL | 02/11/2022 | APPROVED | MKRASKI |
| Note: THIS IS A REINSPECTION Many simplex nails missing on the feild of the underlayment on back half of the roof | |||
| ROOF VALLEY & METAL | 02/04/2022 | Disapproved - NO FEE | MKRASKI |
| Note: Many simplex nails missing on the feild of the underlayment on back half of the roof | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/28/2022 | APPROVED - AS NOTED | KSANDOE |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION this was called in as a partial for a roof sheathing only, need support for panel end for lower roof section at left side of entry, also missing clips at front bump out in sane area 1/28/22 Multiple trusses missing engineering. Marked on truss detail. Check at All Rough | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/26/2022 | CANCELLED BY APPLICANT | KSANDOE |
| Note: THIS IS A REINSPECTION this was called in as a partial for a roof sheathing only, need support for panel end for lower roof section at left side of entry, also missing clips at front bump out in sane area | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/05/2022 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/05/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: this was called in as a partial for a roof sheathing only, need support for panel end for lower roof section at left side of entry, also missing clips at front bump out in sane area | |||
| TIE BEAM / LINTEL | 11/02/2021 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 09/29/2021 | APPROVED | TDOAK |
| MONOLITHIC SLAB | 09/09/2021 | APPROVED | FWILLIS |
| Note: THIS IS A REINSPECTION DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. PLANS IN THE CONSTRUCTION BOX ARE NOT STAMPED AND APPROVED BY THE CITY. | |||
| MONOLITHIC SLAB | 09/07/2021 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. PLANS IN THE CONSTRUCTION BOX ARE NOT STAMPED AND APPROVED BY THE CITY. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/02/2021 | APPROVED | JGIBSON |
| WATER METER INSTALLATION REQUEST | 06/08/2021 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 03/01/2023 | 03/01/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/31/2022 | 02/03/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code Residential PLAN REVIEW COMMENTS: Second Request 1. OK 2. Engineer inspected the ledger and notes the installation was acceptable. Engineer to provide anchoring methods and provide the required load requirements. | |||
| BLD | HOLD | 01/26/2022 | 01/26/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code Residential PLAN REVIEW COMMENTS: 1. Engineer’s letter is addressed to Flagler County Building and Zoning. The correct Building Department would be City of Palm Coast. 2. Engineer inspected the ledger and notes the installation was acceptable. Engineer to provide anchoring methods and provide the required load requirements. | |||
| ENGIN1 | COMPLETE | 09/29/2021 | 09/29/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/29/2021 | 09/29/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BADMIN | HOLD | 06/02/2021 | 06/02/2021 |
| Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC IS NOT RECORDED | |||
| BADMIN | COMPLETE | 06/02/2021 | 06/02/2021 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 05/24/2021 | 05/24/2021 |
| Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM the NOC is not completed and recorded. it also needs to be a legible copy when received. | |||
| SW1 | COMPLETE | 05/17/2021 | 05/18/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/21/2021 | 04/21/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 04/21/2021 | 04/28/2021 |
| Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM You added the arrows but you still need to add the other info, all the elevations | |||
| ELEC | COMPLETE | 04/21/2021 | 04/22/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/21/2021 | 04/22/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/21/2021 | 04/22/2021 |
| Note: Released By: JPI | |||
| BADMIN | HOLD | 04/12/2021 | 04/12/2021 |
| Note: Held By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM YOU HAVE TO SUBMIT THE HOLDS FOR BD AND EL NOT JUST ZONING THEY ALL HAVE TO BE SUBMITTED TOGETHER. | |||
| BADMIN | COMPLETE | 04/12/2021 | 04/12/2021 |
| Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 04/06/2021 | 04/06/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need light and switch by exterior garage door. NEC 2017 210.70 (A) (2)(2) | |||
| BLD | HOLD | 04/06/2021 | 04/07/2021 |
| Note: Held By: JPI 1. Product approval indicates same number for soffit and shingles. Please clarify. Repeating comment | |||
| ZON | HOLD | 04/06/2021 | 04/06/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Rear setback should be shown from back patio to property line Please provide the dimensions of the driveway turnaround. A turnaround can only be 9' wide by 17' long | |||
| SW1 | COMPLETE | 04/06/2021 | 04/12/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 03/24/2021 | 06/21/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/23/2021 | 03/29/2021 |
| Note: Held By: JPI 1. Product approval indicates same number for soffit and shingles. Please clarify. | |||
| CUSVC | COMPLETE | 03/23/2021 | 03/25/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 03/23/2021 | 03/24/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need light and switch by exterior garage door. NEC 2017 210.70 (A) (2)(2) | |||
| ENGIN1 | COMPLETE | 03/23/2021 | 03/24/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US | |||
| LOCATE | COMPLETE | 03/23/2021 | 03/29/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/23/2021 | 03/24/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 03/23/2021 | 03/29/2021 |
| Note: Released By: JPI | |||
| SW1 | HOLD | 03/23/2021 | 03/30/2021 |
| Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM The drainage arrows for proposed and existing are not on the site plan please fix this | |||
| ZON | HOLD | 03/23/2021 | 03/30/2021 |
| Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Site plan/survey must show width of front entry walkway Rear setback missing on Site plan/survey House layout on plans show the side entry garage. Site and landscape plan show driveway going to front of house. Driveway must lead to a garage. One additional tree required for this lot size Additional shrubs required on right side. Shrubs must wrap the corner and have four along the side. AC screening does not count. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 03/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/15/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 03/15/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 03/15/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 03/15/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 03/15/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 03/15/2023 |
| CONTRACTOR CHANGE | ¤40.00 | 02/07/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 02/07/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/07/2022 |
| CONTRACTOR CHANGE | ¤40.00 | 11/02/2021 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/29/2021 |
| ADMIN FEE | ¤20.00 | 05/24/2021 |
| BUILDING DISCOUNT 100% | (¤1,334.00) | 05/24/2021 |
| ELECTRIC FEE | ¤222.00 | 05/24/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 05/24/2021 |
| IMPACT FEE FIRE | ¤367.00 | 05/24/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 05/24/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/24/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 05/24/2021 |
| MECHANICAL FEE | ¤222.00 | 05/24/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 05/24/2021 |
| PLAN CHECK FEE | ¤108.00 | 05/24/2021 |
| PLUMBING FEE | ¤222.00 | 05/24/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤540.00 | 05/24/2021 |
| SITE PLAN 20 | ¤20.00 | 05/24/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 05/24/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 05/24/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 05/24/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 05/24/2021 |
| SEWER CREDIT | (¤1,147.00) | 05/12/2021 |
| SEWER INSPECTION | ¤25.00 | 05/12/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 05/12/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 05/12/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/12/2021 |
| METER - DEPOSIT | ¤60.00 | 05/12/2021 |
| WATER- TURN ON | ¤25.00 | 05/12/2021 |
| CONNECTION FEES | ¤1,017.83 | 05/12/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,446.93 |