I want to search for...

Permit #2021031474

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00240-0150
CONDITIONED SPACE: 2001 sqft
GARAGE: 542 sqft
OPENED PORCH (WITH ROOF) : 410 sqft
OPENED PORCH (WITH ROOF) : 146 sqft
Total Square Footage: 3099 sqft
Block: 00240
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 386-447-7007
Location Address: 22 WHITTIER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/24/2021
NOC: RECORDED
Applicant name: MAXIM TARANNIK
Owner: GLIKIN DAVID

Address

375 WILKINS DRIVE

DES PLAINES, IL 60016

Lot: 0150
Contracted Stated Job Value: ¤269,900.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

GOLDEN MAGNOLIA, INC
Status Location Address State License Number Phone
INACTIVE

1 ROCKEFELLER DRIVE

PALM COAST, FL 32164

RR282811984 (Exp: 08/31/2025) 386-447-7007

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/15/2023 FINAL APPROVED MKRASKI
BLD - BUILDING FINAL 03/14/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 3/14/23 Door locked need access foe inspection , trash still not cleaned up outside stopped inspection. ake sure ALL items are fixed before re-inspection 3/10/2023 - PREVIOUS INSPECTION NOTES 3/10/23 All items need to be repaired before next inspection, also trash needs to be removed by electrical service meter 3/6/2023 - PREVIOUS INSPECTION NOTES 3/6/23 1. Back flow preventer missing tamper screw 2. Light on front not working properly 3. Master shower mixing valve hot and cold reversed 4. Can light in kitchen near pantry not operational 5. Dust covers need to be removed on smoke detectors before final 3/1/2023 - PREVIOUS INSPECTION NOTES 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection
BLD - BUILDING FINAL 03/10/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 3/10/23 All items need to be repaired before next inspection, also trash needs to be removed by electrical service meter 3/6/2023 - PREVIOUS INSPECTION NOTES 3/6/23 1. Back flow preventer missing tamper screw 2. Light on front not working properly 3. Master shower mixing valve hot and cold reversed 4. Can light in kitchen near pantry not operational 5. Dust covers need to be removed on smoke detectors before final 3/1/2023 - PREVIOUS INSPECTION NOTES 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection
U -UTILITY RESIDENTIAL FINAL 03/10/2023 APPROVED - AS NOTED LFITZGERALD
Note: pep tank full-not drawing down? sent issue to Ivan at utility
BLD - BUILDING FINAL 03/06/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 3/6/23 1. Back flow preventer missing tamper screw 2. Light on front not working properly 3. Master shower mixing valve hot and cold reversed 4. Can light in kitchen near pantry not operational 5. Dust covers need to be removed on smoke detectors before final 3/1/2023 - PREVIOUS INSPECTION NOTES 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection
BLD - BUILDING FINAL 03/01/2023 Disapproved - NO FEE MKRASKI
Note: 1. AHU has wrong sie breaker installed 2. All ceiling and wall penitrations need to be sealed in garage 3. Energy cals do not match equipment installed 4. smoke detectors beeping 5. Exposed romex in garage Stopped inspection
U-CROSS CONNECTION 03/01/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no crossconnectio
ROW - STORMWATER FINAL 02/28/2023 APPROVED GBERTOLA
Note: 2/28/23=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD builder will build a berm in the back
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/01/2023 APPROVED GBERTOLA
Note: Inspector Notes from Inspection 9200
ROW FIELD SURVEY /GRADING CERTIFICATION 02/01/2023 APPROVED GBERTOLA
ROW - FINAL APRON (AFTER POUR) 02/01/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW- PROJECT STATUS 01/31/2023 APPROVED - AS NOTED GBERTOLA
Note: still waiting for the phone call to set up time to meet at the location with max
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/24/2023 Disapproved - NO FEE PFLANAGAN
Note: YOUR DRAINAGE IS IMPACTING THE LOTS SURROUNDING YOURS
ROW- PROJECT STATUS 12/14/2022 APPROVED GBERTOLA
Note: I TOOK A LOOK ON THE RE-GRADE
ROW- PROJECT STATUS 12/08/2022 APPROVED GBERTOLA
Note: meeting with the cm David
ROW- PRE-APRON (PRE-POUR) 10/17/2022 APPROVED GBERTOLA
Note: 10/17/22=AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ............................................................................................................................................................................................................................ 10/14/2022 - PREVIOUS INSPECTION NOTES ** 10/14/22 MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** 5" MINIMUM THICK CONCRETE REQUIRED IN THE APRON, RIGHT SIDE NEED FORM BOARDS RAISED. ** UPPER AREA OF DRIVEWAY OUTLINED HIGH SPOT IN PINK PAINT NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEWAY ABOVE ROW. ** CULVERT ELEVATION WAS GOOD AT THE TIME OF THIS INSPECTION
ROW- PRE-APRON (PRE-POUR) 10/14/2022 Disapproved -FEE REQUIRED EMADISON
Note: ** 10/14/22 MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** 5" MINIMUM THICK CONCRETE REQUIRED IN THE APRON, RIGHT SIDE NEED FORM BOARDS RAISED. ** UPPER AREA OF DRIVEWAY OUTLINED HIGH SPOT IN PINK PAINT NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEWAY ABOVE ROW. ** CULVERT ELEVATION WAS GOOD AT THE TIME OF THIS INSPECTION
U - SEWER TIE IN 09/02/2022 APPROVED DCUSHING
GRAVITY SEWER TEST 09/02/2022 APPROVED DCUSHING
ELECTRIC - EARLY POWER 08/31/2022 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 12:25PM 8/31/22
WINDOW NAILING 08/11/2022 APPROVED MKRASKI
PEP TANK INSTALLATION REQUEST 08/09/2022 APPROVED CSTONE
Note: THIS IS A REINSPECTION ADDED ON 7/25/2022 3:50:52 PM (stucco, stone, or siding must be applied)
PEP TANK INSTALLATION REQUEST 07/21/2022 Disapproved - NO FEE TCHURCHILL
Note: (stucco, stone, or siding must be applied)
INSULATION 07/18/2022 APPROVED MKRASKI
LATH/BRICK/ WATER BARRIER 07/12/2022 APPROVED MKRASKI
ALL ROUGH 03/21/2022 APPROVED - AS NOTED MKRASKI
Note: 1. Dryer vent and hood vent seams need to be sealed 2. No 5' head pressure 3. Spare bathroom tub needs to be sealed at floor 4. Kitchen floor needs rio be sealed in island Check on insulation
ALL ROUGH 03/15/2022 Disapproved - NO FEE KSANDOE
Note: 1/28/22 Multiple trusses missing engineering. Marked on truss detail. Check at All Rough 3/15/22 - Trusses still missing engineering. Cannot spray foam insulation into trusses still missing bracing. Window nailing inspection addeed
ROOF VALLEY & METAL 02/11/2022 APPROVED MKRASKI
Note: THIS IS A REINSPECTION Many simplex nails missing on the feild of the underlayment on back half of the roof
ROOF VALLEY & METAL 02/04/2022 Disapproved - NO FEE MKRASKI
Note: Many simplex nails missing on the feild of the underlayment on back half of the roof
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/28/2022 APPROVED - AS NOTED KSANDOE
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION this was called in as a partial for a roof sheathing only, need support for panel end for lower roof section at left side of entry, also missing clips at front bump out in sane area 1/28/22 Multiple trusses missing engineering. Marked on truss detail. Check at All Rough
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/26/2022 CANCELLED BY APPLICANT KSANDOE
Note: THIS IS A REINSPECTION this was called in as a partial for a roof sheathing only, need support for panel end for lower roof section at left side of entry, also missing clips at front bump out in sane area
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/05/2022 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/05/2022 Disapproved -FEE REQUIRED LMILLER
Note: this was called in as a partial for a roof sheathing only, need support for panel end for lower roof section at left side of entry, also missing clips at front bump out in sane area
TIE BEAM / LINTEL 11/02/2021 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 09/29/2021 APPROVED TDOAK
MONOLITHIC SLAB 09/09/2021 APPROVED FWILLIS
Note: THIS IS A REINSPECTION DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. PLANS IN THE CONSTRUCTION BOX ARE NOT STAMPED AND APPROVED BY THE CITY.
MONOLITHIC SLAB 09/07/2021 Disapproved -FEE REQUIRED FWILLIS
Note: DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. PLANS IN THE CONSTRUCTION BOX ARE NOT STAMPED AND APPROVED BY THE CITY.
PLUMBING 1ST ROUGH UNDERGROUND 09/02/2021 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 06/08/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 03/01/2023 03/01/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 01/31/2022 02/03/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code Residential PLAN REVIEW COMMENTS: Second Request 1. OK 2. Engineer inspected the ledger and notes the installation was acceptable. Engineer to provide anchoring methods and provide the required load requirements.
BLD HOLD 01/26/2022 01/26/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code Residential PLAN REVIEW COMMENTS: 1. Engineer’s letter is addressed to Flagler County Building and Zoning. The correct Building Department would be City of Palm Coast. 2. Engineer inspected the ledger and notes the installation was acceptable. Engineer to provide anchoring methods and provide the required load requirements.
ENGIN1 COMPLETE 09/29/2021 09/29/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/29/2021 09/29/2021
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BADMIN HOLD 06/02/2021 06/02/2021
Note: Held By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC IS NOT RECORDED
BADMIN COMPLETE 06/02/2021 06/02/2021
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM
BADMIN COMPLETE 05/24/2021 05/24/2021
Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM the NOC is not completed and recorded. it also needs to be a legible copy when received.
SW1 COMPLETE 05/17/2021 05/18/2021
Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/21/2021 04/21/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 04/21/2021 04/28/2021
Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM You added the arrows but you still need to add the other info, all the elevations
ELEC COMPLETE 04/21/2021 04/22/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 04/21/2021 04/22/2021
Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 04/21/2021 04/22/2021
Note: Released By: JPI
BADMIN HOLD 04/12/2021 04/12/2021
Note: Held By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM YOU HAVE TO SUBMIT THE HOLDS FOR BD AND EL NOT JUST ZONING THEY ALL HAVE TO BE SUBMITTED TOGETHER.
BADMIN COMPLETE 04/12/2021 04/12/2021
Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM
ELEC HOLD 04/06/2021 04/06/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need light and switch by exterior garage door. NEC 2017 210.70 (A) (2)(2)
BLD HOLD 04/06/2021 04/07/2021
Note: Held By: JPI 1. Product approval indicates same number for soffit and shingles. Please clarify. Repeating comment
ZON HOLD 04/06/2021 04/06/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Rear setback should be shown from back patio to property line Please provide the dimensions of the driveway turnaround. A turnaround can only be 9' wide by 17' long
SW1 COMPLETE 04/06/2021 04/12/2021
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
SWALE COMPLETE 03/24/2021 06/21/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 03/23/2021 03/29/2021
Note: Held By: JPI 1. Product approval indicates same number for soffit and shingles. Please clarify.
CUSVC COMPLETE 03/23/2021 03/25/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 03/23/2021 03/24/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need light and switch by exterior garage door. NEC 2017 210.70 (A) (2)(2)
ENGIN1 COMPLETE 03/23/2021 03/24/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@CI.PALM-COAST.FL.US
LOCATE COMPLETE 03/23/2021 03/29/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 03/23/2021 03/24/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 03/23/2021 03/29/2021
Note: Released By: JPI
SW1 HOLD 03/23/2021 03/30/2021
Note: Held By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM The drainage arrows for proposed and existing are not on the site plan please fix this
ZON HOLD 03/23/2021 03/30/2021
Note: Held By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM Site plan/survey must show width of front entry walkway Rear setback missing on Site plan/survey House layout on plans show the side entry garage. Site and landscape plan show driveway going to front of house. Driveway must lead to a garage. One additional tree required for this lot size Additional shrubs required on right side. Shrubs must wrap the corner and have four along the side. AC screening does not count.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/15/2023
REINSPECTION RESIDENTIAL ¤40.00 03/15/2023
REINSPECTION RESIDENTIAL ¤40.00 03/15/2023
REINSPECTION RESIDENTIAL ¤40.00 03/15/2023
CONTRACTOR CHANGE ¤20.00 03/15/2023
SW ENG REINSPECTION 20 ¤20.00 03/15/2023
SW ENG REINSPECTION 20 ¤20.00 03/15/2023
SW ENG REINSPECTION 20 ¤20.00 03/15/2023
SW ENG REINSPECTION 30 ¤30.00 03/15/2023
CONTRACTOR CHANGE ¤40.00 02/07/2022
CONTRACTOR CHANGE ¤40.00 02/07/2022
REINSPECTION RESIDENTIAL ¤40.00 02/07/2022
CONTRACTOR CHANGE ¤40.00 11/02/2021
REINSPECTION RESIDENTIAL ¤40.00 09/29/2021
ADMIN FEE ¤20.00 05/24/2021
BUILDING DISCOUNT 100% (¤1,334.00) 05/24/2021
ELECTRIC FEE ¤222.00 05/24/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 05/24/2021
IMPACT FEE FIRE ¤367.00 05/24/2021
IMPACT FEE PARKS ¤1,199.12 05/24/2021
IMPACT FEE SCHOOL ¤3,600.00 05/24/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 05/24/2021
MECHANICAL FEE ¤222.00 05/24/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 05/24/2021
PLAN CHECK FEE ¤108.00 05/24/2021
PLUMBING FEE ¤222.00 05/24/2021
NEW RESIDENTIAL INSPECTIONS ¤540.00 05/24/2021
SITE PLAN 20 ¤20.00 05/24/2021
SURCHARGE FS 533.721 ¤2.00 05/24/2021
SURCHARGE - FS 468.631 ¤2.00 05/24/2021
STORM WATER PERMIT FEES ¤80.00 05/24/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 05/24/2021
SEWER CREDIT (¤1,147.00) 05/12/2021
SEWER INSPECTION ¤25.00 05/12/2021
SEWER CAPITAL FACILITY ¤4,664.55 05/12/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 05/12/2021
WATER -IRRIGATION INSPECTION ¤25.00 05/12/2021
METER - DEPOSIT ¤60.00 05/12/2021
WATER- TURN ON ¤25.00 05/12/2021
CONNECTION FEES ¤1,017.83 05/12/2021
Fees Total Due: ¤0.00 Total Paid: ¤15,446.93