Permit #2021040236
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7033-00390-0230 |
| Total Square Footage: 300 sqft |
| Block: 00390 |
| Subdivision: 2184 - SECTION 33-ROYAL PALMS |
| Job Phone: (386)451-0113 |
| Location Address: 19 RENWORTH LN |
| Type: BA - BUILDING ADDITION |
| Issue Date: 06/02/2021 |
| NOC: Unknown |
| Applicant name: ANDREA L JONES |
| Owner: BENTLEY, THOMAS |
|
Address 19 RENWORTH LANE PALM COAST, FL 32164 |
| Lot: 0230 |
| Contracted Stated Job Value: ¤2,400.00 |
| Job Description: 12x25 composite roof on existing slab |
| Type: CN |
Contractor
ALUMINUM CREATIONS, CORP.
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
155 DAWSON BROWN RD. DE LEON SPRINGS, FL 32130 |
SCC131149810 (Exp: 08/31/2026) | 850-640-9350 | 866-344-3908 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/05/2021 | FINAL APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 3X3 POST IS ATTACHED TO BRACKET WITH (2) 3/8" X 3 1/2" CARRIAGE BOLTS Only 1 carriage bolt used per post. Install 2 per or submitt engineering revision. The gutter used is not the specified gutter on drawing. Leaving the FOAM ends of the insulated panels exposed. The anchors are to be 24" o.c. at gutter use correct gutter and proper spacing of anchors 3" C CHANNEL IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4" X 1/4" TAPCONS 6" FROM ENDS 24" O.C. & TO 3" INSULATED ROOF WITH (6) #10 1" PER SIDE Not able to view how the 3" channel was connected to home due to concelment. 7/20/21 The ends of the panels where the foam was exposed has not been properly capped as per the drawings. A drip edge was used which is still allowing water intrusion to the foam at the bottom of the panel Remove gutters and use capping that seal ends completely. Or provide manufactures worksheet showing drip edge installation as installed. | |||
| BLD - BUILDING FINAL | 07/20/2021 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION 3X3 POST IS ATTACHED TO BRACKET WITH (2) 3/8" X 3 1/2" CARRIAGE BOLTS Only 1 carriage bolt used per post. Install 2 per or submitt engineering revision. The gutter used is not the specified gutter on drawing. Leaving the FOAM ends of the insulated panels exposed. The anchors are to be 24" o.c. at gutter use correct gutter and proper spacing of anchors 3" C CHANNEL IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4" X 1/4" TAPCONS 6" FROM ENDS 24" O.C. & TO 3" INSULATED ROOF WITH (6) #10 1" PER SIDE Not able to view how the 3" channel was connected to home due to concelment. 7/20/21 The ends of the panels where the foam was exposed has not been properly capped as per the drawings. A drip edge was used which is still allowing water intrusion to the foam at the bottom of the panel Remove gutters and use capping that seal ends completely. Or provide manufactures worksheet showing drip edge installation as installed. | |||
| BLD - BUILDING FINAL | 06/11/2021 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 3X3 POST IS ATTACHED TO BRACKET WITH (2) 3/8" X 3 1/2" CARRIAGE BOLTS Only 1 carriage bolt used per post. Install 2 per or submitt engineering revision. The gutter used is not the specified gutter on drawing. Leaving the FOAM ends of the insulated panels exposed. The anchors are to be 24" o.c. at gutter use correct gutter and proper spacing of anchors 3" C CHANNEL IS ATTACHED TO BLOCK STRUCTURE WITH 2-1/4" X 1/4" TAPCONS 6" FROM ENDS 24" O.C. & TO 3" INSULATED ROOF WITH (6) #10 1" PER SIDE Not able to view how the 3" channel was connected to home due to concelment. | |||
| ROW - STORMWATER FINAL | 06/10/2021 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 06/10/2021 | FINAL APPROVED | LFITZGERALD |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/07/2021 | 07/13/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/16/2021 | 04/23/2021 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/06/2021 | 04/12/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Provide product approval of composite roofing material per F. S. 553.84. 2. Provide size of footer, and dimensions on screen enclosure plan to coodinate with site plan for clarity per FBC 7th Ed. Sec. 107.2.1. | |||
| SW1 | COMPLETE | 04/06/2021 | 04/12/2021 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/06/2021 | 04/06/2021 |
| Note: Held By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM Provide setback from right side of proposed improvement to property line. It appears to extend past the side of the home. | |||
| ZON | COMPLETE | 04/06/2021 | 04/06/2021 |
| Note: Released By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION FEE | ¤40.00 | 08/04/2021 |
| REINSPECTION FEE | ¤40.00 | 06/25/2021 |
| ADMIN FEE | ¤20.00 | 06/02/2021 |
| BUILDING DISCOUNT 100% | (¤100.00) | 06/02/2021 |
| PLAN CHECK FEE | ¤40.00 | 06/02/2021 |
| REMODEL/ADDITION/ACCES INSPECT | ¤40.00 | 06/02/2021 |
| SITE PLAN 20 | ¤20.00 | 06/02/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/02/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/02/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 06/02/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤184.00 |