Permit #2021040513

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00470-0040
CONDITIONED SPACE: 2397 sqft
GARAGE: 592 sqft
OPENED PORCH (WITH ROOF) : 197 sqft
OPENED PORCH (WITH ROOF) : 87 sqft
Total Square Footage: 3273 sqft
Block: 00470
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 321-610-3924
Location Address: 16 ESSINGTON LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/15/2021
NOC: RECORDED
Applicant name: KENNETH WAYNE CAMBELL JR
Owner: VINTAGE ESTATE HOMES LLC

Address

4885 N WICKHAM ROAD

MELBOURNE, FL 32940

Lot: 0040
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MERCEDES PREMIER HOMES LLC
Status Location Address Mailing Address State License Number Phone
CANCEL

4885 N WICKHAM RD

MELBOURNE, FL 32940

SUITE 101

MELBOURNE, FL 32940

CBC058803 (Exp: 08/31/2022) 321-610-3924

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
SANTOS L HERNANDEZ
Status Location Address State License Number Phone Fax
ACTIVE

946 SHADDICK DRIVE

ORANGE CITY, FL 32763

CCC1328011 (Exp: 08/31/2026) 386-218-4942 386-218-4937
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
ZACHARY PETER BOERA
Status Location Address State License Number Phone
CANCEL

7225 SANDSCOVE COURT, SUITE 1

WINTER PARK, FL 32792

CAC1817652 (Exp: 08/31/2022) 407-629-6920

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/29/2021 CANCELLED BY APPLICANT WEB
Note: THIS IS A REINSPECTION
BLD - BUILDING FINAL 12/29/2021 FINAL APPROVED JWALKER
Note: New inspection due to canceled inspection THIS IS A REINSPECTION
U-CROSS CONNECTION 12/28/2021 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROW - STORMWATER FINAL 12/28/2021 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
U -UTILITY RESIDENTIAL FINAL 12/28/2021 FINAL APPROVED JHARDING
BLD - BUILDING FINAL 12/28/2021 CANCELLED BY APPLICANT KSANDOE
FINAL SURVEY (OFFICE USE ONLY) 12/27/2021 APPROVED GBERTOLA
Note: 12/27/2021=CORRECTION WERE MADE LEFT SIDE ELEVATION GOING FROM 27.75-- 27.30- 27.80 WATER IS GOING TO POUND IN THE BACK NO ENOUGH FALL TO THE FRONT
ROW FIELD SURVEY /GRADING CERTIFICATION 12/27/2021 APPROVED GBERTOLA
Note: 12/27/2021=CORRECTION WERE MADE LEFT SIDE ELEVATION GOING FROM 27.75-- 27.30- 27.80 WATER IS GOING TO POUND IN THE BACK NO ENOUGH FALL TO THE FRONT
ROW - FINAL APRON (AFTER POUR) 12/27/2021 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW FIELD SURVEY /GRADING CERTIFICATION 12/20/2021 Disapproved - NO FEE GBERTOLA
Note: LEFT SIDE ELEVATION GOING FROM 27.75-- 27.30- 27.80 WATER IS GOING TO POUND IN THE BACK NO ENOUGH FALL TO THE FRONT
FINAL SURVEY (OFFICE USE ONLY) 12/20/2021 Disapproved - NO FEE GBERTOLA
Note: LEFT SIDE ELEVATION GOING FROM 27.75-- 27.30- 27.80 WATER IS GOING TO POUND IN THE BACK NO ENOUGH FALL TO THE FRONT
ELECTRIC - EARLY POWER 11/30/2021 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 9:03 am
ROW- PRE-APRON (PRE-POUR) 11/18/2021 APPROVED RGROSS
Note: THIS IS A REINSPECTION Too much material outside the 2 car garage. See paint. String line indicates only 3 inches thick in much of the painted area. 11/18/21 - Corrections made. READY TO POUR
ROW- PRE-APRON (PRE-POUR) 11/17/2021 Disapproved -FEE REQUIRED RGROSS
Note: Too much material outside the 2 car garage. See paint. String line indicates only 3 inches thick in much of the painted area.
U - SEWER TIE IN 11/12/2021 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 10/12/2021 APPROVED - AS NOTED CSTONE
Note: dumpster will need to move
INSULATION 10/12/2021 APPROVED JWALKER
LATH/BRICK/ WATER BARRIER 10/05/2021 APPROVED TSTAUFFACHER
ALL ROUGH 10/01/2021 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION The 16 Gage strap used at Dryer duct at the wood top plate needs to have 8 fasteners per side installed. The Kitchen exhaust vent need to have all joints sealed. The dryer duct vent needs to have all joints sealed The metal stud framing needs to be grounded The Air handler will need to be bonded to the metal framing The Air supply in the toilet rm is hanging and needs to be fastened to the ceiling joist. The Spray foam used at the HVAC plenum is not fire rated and needs to be removed and approved fire blocking/ foam installed.
ALL ROUGH 09/30/2021 CANCELLED BY APPLICANT JWALKER
Note: THIS IS A REINSPECTION The 16 Gage strap used at Dryer duct at the wood top plate needs to have 8 fasteners per side installed. The Kitchen exhaust vent need to have all joints sealed. The dryer duct vent needs to have all joints sealed The metal stud framing needs to be grounded The Air handler will need to be bonded to the metal framing The Air supply in the toilet rm is hanging and needs to be fastened to the ceiling joist. The Spray foam used at the HVAC plenum is not fire rated and needs to be removed and approved fire blocking/ foam installed.
ALL ROUGH 09/27/2021 Disapproved - NO FEE JWALKER
Note: The 16 Gage strap used at Dryer duct at the wood top plate needs to have 8 fasteners per side installed. The Kitchen exhaust vent need to have all joints sealed. The dryer duct vent needs to have all joints sealed The metal stud framing needs to be grounded The Air handler will need to be bonded to the metal framing The Air supply in the toilet rm is hanging and needs to be fastened to the ceiling joist. The Spray foam used at the HVAC plenum is not fire rated and needs to be removed and approved fire blocking/ foam installed.
ROW - DRAINAGE 09/16/2021 APPROVED RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION Builder did install a temporary culvert but it is clogged and not draining. Needs to be opened for drainage. Next Inspection 7/29/21. 7/29/2021=DRIANAGE ACROSS THE FRONT SWALE IS OPEN NO CORRECTION NEED AT THE TIME OF THE INSPECTION 8/26/21 - Drainage open a the time of Inspection. Next check 9/2/21. 9/2/21 - Temporary Culvert is completely blocked on one end. Next check 9/16/21.
ROW - DRAINAGE 09/02/2021 Disapproved -FEE REQUIRED RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION Builder did install a temporary culvert but it is clogged and not draining. Needs to be opened for drainage. Next Inspection 7/29/21. 7/29/2021=DRIANAGE ACROSS THE FRONT SWALE IS OPEN NO CORRECTION NEED AT THE TIME OF THE INSPECTION 8/26/21 - Drainage open a the time of Inspection. Next check 9/2/21. 9/2/21 - Temporary Culvert is completely blocked on one end. Next check 9/16/21.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/30/2021 APPROVED - AS NOTED KSANDOE
Note: TRUSS B1 (a) BROKEN/CRACKED. SUPPLY ENGINEERING WORKSHEET FOR PROPER TRUSS REPAIR
ROOF VALLEY & METAL 08/30/2021 APPROVED KSANDOE
ROW - DRAINAGE 08/26/2021 PARTIALLY APPROVED RGROSS
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Builder did install a temporary culvert but it is clogged and not draining. Needs to be opened for drainage. Next Inspection 7/29/21. 7/29/2021=DRIANAGE ACROSS THE FRONT SWALE IS OPEN NO CORRECTION NEED AT THE TIME OF THE INSPECTION 8/26/21 - Drainage open a the time of Inspection. Next check 9/2/21.
FOUND SURVEY APPROVED (OFFICE) 08/06/2021 APPROVED TBAKER
TIE BEAM / LINTEL 08/04/2021 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION Called at 9.30 AM
TIE BEAM / LINTEL 08/02/2021 CANCELLED BY APPLICANT TSTAUFFACHER
Note: Called at 9.30 AM
ROW - DRAINAGE 07/29/2021 PARTIALLY APPROVED GBERTOLA
Note: THIS IS A REINSPECTION Builder did install a temporary culvert but it is clogged and not draining. Needs to be opened for drainage. Next Inspection 7/29/21. 7/29/2021=DRIANAGE ACROSS THE FRONT SWALE IS OPEN NO CORRECTION NEED AT THE TIME OF THE INSPECTION
ROW - DRAINAGE 07/22/2021 Disapproved - NO FEE RGROSS
Note: Builder did install a temporary culvert but it is clogged and not draining. Needs to be opened for drainage. Next Inspection 7/29/21.
MONOLITHIC SLAB 07/09/2021 APPROVED JWALKER
Note: THIS IS A REINSPECTION Soil collapse into the footer at several area's Pulled and left up to test sting lines for slab depth. 3 1/2" is the minimum slab depth. areas measured at 3.
MONOLITHIC SLAB 07/06/2021 Disapproved - NO FEE JWALKER
Note: Soil collapse into the footer at several area's Pulled and left up to test sting lines for slab depth. 3 1/2" is the minimum slab depth. areas measured at 3.
PLUMBING 1ST ROUGH UNDERGROUND 06/25/2021 APPROVED JGIBSON
GRAVITY SEWER TEST 06/25/2021 APPROVED JGIBSON
WATER METER INSTALLATION REQUEST 06/24/2021 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 12/28/2021 12/28/2021
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/06/2021 08/06/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/06/2021 08/06/2021
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 05/10/2021 05/11/2021
Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 05/06/2021 05/07/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM 1. Orientation of Energy Calcs does not match the site plan. Revise to match the site plan (Second Request) 2. Design location needs to be closer to Palm Coast. I. E., Daytona Beach or St. Augustine.
ELEC COMPLETE 05/06/2021 05/07/2021
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 04/12/2021 07/07/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 04/09/2021 04/17/2021
Note: Released By: JPI
CUSVC COMPLETE 04/09/2021 04/13/2021
Note: Released By: HALEIGH HAND - -
ELEC HOLD 04/09/2021 04/12/2021
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need to reference the 2017 NEC
ENGIN1 COMPLETE 04/09/2021 04/12/2021
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 04/09/2021 04/14/2021
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 04/09/2021 04/12/2021
Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM Orientation of Energy Calcs does not match the site plan. Revise to match the site plan
PLUM COMPLETE 04/09/2021 04/17/2021
Note: Released By: JPI
SW1 COMPLETE 04/09/2021 04/13/2021
Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM
ZON COMPLETE 04/09/2021 04/14/2021
Note: Released By: TRACEY DOAK - (386)986-2473 - TDOAK@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 12/29/2021
SW ENG - INSPECTION 20 ¤20.00 12/29/2021
SW ENG - INSPECTION 20 ¤20.00 12/29/2021
SW ENG REINSPECTION 30 ¤30.00 12/29/2021
STORM WATER PERMIT FEES ¤80.00 06/15/2021
3% TRANS IMPACT FEE CREDIT (¤51.54) 06/15/2021
SEWER CREDIT (¤850.00) 06/15/2021
SEWER INSPECTION ¤25.00 06/15/2021
SEWER CAPITAL FACILITY ¤4,664.55 06/15/2021
WATER CAPITAL FACILITY FEE ¤3,424.45 06/15/2021
METER - DEPOSIT ¤60.00 06/15/2021
WATER- TURN ON ¤25.00 06/15/2021
ADMIN FEE ¤20.00 06/15/2021
CONNECTION FEES ¤1,017.83 06/15/2021
CONTRACTOR CHANGE ¤40.00 06/15/2021
BUILDING DISCOUNT 100% (¤1,468.40) 06/15/2021
ELECTRIC FEE ¤241.20 06/15/2021
3% FIRE IMPACT FEE CREDIT (¤11.01) 06/15/2021
IMPACT FEE FIRE ¤367.00 06/15/2021
IMPACT FEE PARKS ¤1,199.12 06/15/2021
IMPACT FEE SCHOOL ¤3,600.00 06/15/2021
IMPACT FEE TRANSPORTATION ¤1,718.00 06/15/2021
MECHANICAL FEE ¤241.20 06/15/2021
WATER -IRRIGATION INSPECTION ¤25.00 06/15/2021
3% PARKS IMPACT FEE CREDIT (¤35.97) 06/15/2021
PLAN CHECK FEE ¤120.80 06/15/2021
PLUMBING FEE ¤241.20 06/15/2021
NEW RESIDENTIAL INSPECTIONS ¤604.00 06/15/2021
SITE PLAN 20 ¤20.00 06/15/2021
SURCHARGE FS 533.721 ¤2.00 06/15/2021
SURCHARGE - FS 468.631 ¤2.00 06/15/2021
Fees Total Due: ¤0.00 Total Paid: ¤15,423.93