Permit #2021040887
Permit Details
Status: COED
| Parcel Id: 07-11-31-7030-00090-0040 |
| CONDITIONED SPACE: 1824 sqft |
| GARAGE: 663 sqft |
| OPENED PORCH (WITH ROOF) : 371 sqft |
| OPENED PORCH (WITH ROOF) : 31 sqft |
| Total Square Footage: 2889 sqft |
| Block: 00090 |
| Subdivision: 2154 - SECTION 30-ROYAL PALMS |
| Job Phone: 386-447-4151 |
| Location Address: 25 RAEMOND LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/30/2021 |
| NOC: RECORDED |
| Applicant name: GENE WARREN SLONE |
| Owner: WERTZ VICKI LANETTE & PENNY SUE MARKULIS AMC |
|
Address 30 ROLLER LN PALM COAST, FL 32164 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
FLORIDA GREEN CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone |
| INACTIVE |
870 E RETTA STREET DELEON SPRINGS, FL 32130 |
CBC1260957 (Exp: 08/31/2026) | 407-580-2657 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
ERIC FRANCO
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
840 DELTONA BLVD DELTONA, FL 32725 |
STE F2 DELTONA, FL 32725 |
CCC1327280 (Exp: 08/31/2026) | 386-575-4007 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
KERRY DWAIN AYLESWORTH II
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
2820 LEWIS SPEEDWAY ST AUGUSTINE, FL 32084 |
STE B ST AUGUSTINE, FL 32084 |
CAC1820713 (Exp: 08/31/2026) | 904-342-5709 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/24/2023 | FINAL APPROVED | JWALKER |
| Note: 1/23/2023 - PREVIOUS INSPECTION NOTES 1/20/2023 - PREVIOUS INSPECTION NOTES 1. The flex duct in the garage attic at the fresh air intake fan need to be sealed both sides. 2. The exterior outlet and dissconnect for the Heat Pump need to be in readily accessible location. Move the Heat pump of the outlet. 3. Outlet under the sink needs to be readily accessible. 1/23/23 Sink under outlet not corrected. | |||
| BLD - BUILDING FINAL | 01/23/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1/20/2023 - PREVIOUS INSPECTION NOTES 1. The flex duct in the garage attic at the fresh air intake fan need to be sealed both sides. 2. The exterior outlet and dissconnect for the Heat Pump need to be in readily accessible location. Move the Heat pump of the outlet. 3. Outlet under the sink needs to be readily accessible. 1/23/23 Sink under outlet not corrected. | |||
| ROW - STORMWATER FINAL | 01/23/2023 | APPROVED | GBERTOLA |
| Note: 01/23/23=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1/20/2023 - PREVIOUS INSPECTION NOTES 01/20/23= NEED TO MATCH EXISTING GRADE AT EACH PROPERTY LINE, WATER FLOW FROM THE RIGHT TO THE LEFT .CHECK SWALE PLAN DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 01/19/23=NEED TO MATCH EXISTING GRADE AT EACH PROPERTY LINE, WATER FLOW FROM THE RIGHT TO THE LEFT .CHECK SWALE PLAN DETAIL. ON THE LEFT SIDE PROPERTY LINE SWALE NEED TO RAISED. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/20/2023 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL APRON (AFTER POUR) | 01/20/2023 | APPROVED | GBERTOLA |
| Note: 01/20/23= correction were made AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 01/19/23=NEED TO MATCH EXISTING GRADE AT EACH PROPERTY LINE, WATER FLOW FROM THE RIGHT TO THE LEFT .CHECK SWALE PLAN DETAIL. ON THE LEFT SIDE PROPERTY LINE SWALE NEED NEED TO RAISED. NEED EXPANSION JOINT CUT DOWN THE CENTER AND LENGTH OF THE PIPE. | |||
| ROW - STORMWATER FINAL | 01/20/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 01/20/23= NEED TO MATCH EXISTING GRADE AT EACH PROPERTY LINE, WATER FLOW FROM THE RIGHT TO THE LEFT .CHECK SWALE PLAN DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 01/19/23=NEED TO MATCH EXISTING GRADE AT EACH PROPERTY LINE, WATER FLOW FROM THE RIGHT TO THE LEFT .CHECK SWALE PLAN DETAIL. ON THE LEFT SIDE PROPERTY LINE SWALE NEED TO RAISED. | |||
| U-CROSS CONNECTION | 01/20/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irrigation with PVB installed-no cross connection Also has irrigation meter that is not connected and will not be used-spoke with Gene to have it removed. | |||
| BLD - BUILDING FINAL | 01/20/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. The flex duct in the garage attic at the fresh air intake fan need to be sealed both sides. 2. The exterior outlet and dissconnect for the Heat Pump need to be in readily accessible location. Move the Heat pump of the outlet. 3. Outlet under the sink needs to be readily accessible. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/19/2023 | APPROVED | GBERTOLA |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/19/2023 | APPROVED - AS NOTED | GBERTOLA |
| Note: 01/19/23=NEED TO MATCH EXISTING GRADE AT EACH PROPERTY LINE, WATER FLOW FROM THE RIGHT TO THE LEFT .CHECK SWALE PLAN DETAIL. ON THE LEFT SIDE PROPERTY LINE SWALE NEED NEED TO RAISED. NEED EXPANSION JOINT CUT DOWN THE CENTER AND LENGTH OF THE PIPE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/06/2022 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 9270 09/20/22= AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 09/08/22= FRONT FORM BOARD IS MISSING. NEED TO REPAIR THE WASHOUTON THE DRIVEWAY ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. REMOVE THE PLYWOOD FROM THE DRIVEWAY. REMOVE THE WOOD STAKE FROM THE DRIVEWAY ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Culvert way out of tolerance on the right side creating 0 inches of Concrete over the pipe and tilted far more than 1 tenth. Possibly floated during a heavy rain event. | |||
| ELECTRIC-TUG | 11/16/2022 | Disapproved - NO FEE | RMARTIN |
| Note: NEED A METER MAIN FOR TUG INSPECTION | |||
| ELECTRIC - EARLY POWER | 10/12/2022 | Disapproved - NO FEE | JWALKER |
| Note: 10/6/2022 - PREVIOUS INSPECTION NOTES Need to add generator to electric plans and site plan. 10/12/22 Above listed correction has not been made. | |||
| ELECTRIC - EARLY POWER | 10/12/2022 | APPROVED - AS NOTED | JWALKER |
| Note: Contractor will be pulling a permitt for the generator. Emailed FPL 12:52pm | |||
| ELECTRIC - EARLY POWER | 10/06/2022 | Disapproved -FEE REQUIRED | JMUNSON |
| Note: Need to add generator to electric plans and site plan. Generator must be 5 feet away from ANY window that opens. Per manufacture specs. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/20/2022 | APPROVED - AS NOTED | GBERTOLA |
| Note: 09/20/22= AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, 09/08/22= FRONT FORM BOARD IS MISSING. NEED TO REPAIR THE WASHOUTON THE DRIVEWAY ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. REMOVE THE PLYWOOD FROM THE DRIVEWAY. REMOVE THE WOOD STAKE FROM THE DRIVEWAY ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Culvert way out of tolerance on the right side creating 0 inches of Concrete over the pipe and tilted far more than 1 tenth. Possibly floated during a heavy rain event. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/09/2022 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 09/09/22=NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE ......................................................................................................................................................................................................... 09/08/22= FRONT FORM BOARD IS MISSING. NEED TO REPAIR THE WASHOUTON THE DRIVEWAY ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. REMOVE THE PLYWOOD FROM THE DRIVEWAY. REMOVE THE WOOD STAKE FROM THE DRIVEWAY CULVERT PIPE IS GOOD ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Culvert way out of tolerance on the right side creating 0 inches of Concrete over the pipe and tilted far more than 1 tenth. Possibly floated during a heavy rain event. | |||
| ROW- PRE-APRON (PRE-POUR) | 09/08/2022 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 09/08/22= FRONT FORM BOARD IS MISSING. NEED TO REPAIR THE WASHOUTON THE DRIVEWAY ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. REMOVE THE PLYWOOD FROM THE DRIVEWAY. REMOVE THE WOOD STAKE FROM THE DRIVEWAY ,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, Culvert way out of tolerance on the right side creating 0 inches of Concrete over the pipe and tilted far more than 1 tenth. Possibly floated during a heavy rain event. | |||
| ELECTRIC UNDERGROUND | 08/25/2022 | CANCELLED BY INSPECTOR | JMUNSON |
| Note: This inspection is not needed | |||
| ROW- PRE-APRON (PRE-POUR) | 08/23/2022 | Disapproved -FEE REQUIRED | RGROSS |
| Note: Culvert way out of tolerance on the right side creating 0 inches of Concrete over the pipe and tilted far more than 1 tenth. Possibly floated during a heavy rain event. | |||
| GRAVITY SEWER TEST | 07/18/2022 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 07/18/2022 | APPROVED | MGIBSON |
| Note: THIS IS A REINSPECTION | |||
| U - SEWER TIE IN | 07/15/2022 | Disapproved - NO FEE | JWALKER |
| Note: Unable to see connection. Hole filled with soil | |||
| PEP TANK INSTALLATION REQUEST | 07/05/2022 | APPROVED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 6/16/2022 3:19:16 PM temp power pole needs to move | |||
| PEP TANK INSTALLATION REQUEST | 06/16/2022 | Disapproved - NO FEE | CSTONE |
| Note: temp power pole needs to move | |||
| INSULATION | 06/10/2022 | APPROVED | JWALKER |
| ELECTRIC 2ND ROUGH | 06/10/2022 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 06/07/2022 | APPROVED | JWALKER |
| ALL ROUGH | 06/03/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Ground conductor wire at meter to UFER needs to be protected HVAC line set not installed into sleeve not sealed Toilet drain in master shower is set less than 15" to the shower wall. Check for 15" clearance when toilet is set. Seal floor at kitchen where concrete has be cut out. Nail plates at multiple top chord locations need to be installed check all, The exterior wall top chords need to be nail plated. | |||
| ALL ROUGH | 05/25/2022 | Disapproved - NO FEE | JWALKER |
| Note: Ground conductor wire at meter to UFER needs to be protected HVAC line set not installed into sleeve not sealed Toilet drain in master shower is set less than 15" to the shower wall. Check for 15" clearance when toilet is set. Seal floor at kitchen where concrete has be cut out. Nail plates at multiple top chord locations need to be installed check all, The exterior wall top chords need to be nail plated. | |||
| ROOF VALLEY & METAL | 01/05/2022 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION Appears the roofed ran out of the approved underlayment on the worksheet and used a different peel and stick to finish the roof. Have contractor submitt a revision for the two types of peel and stick underlayment used or remove and use appoved underlayment list on the work sheet. | |||
| ROOF VALLEY & METAL | 12/29/2021 | Disapproved - NO FEE | JWALKER |
| Note: Appears the roofed ran out of the approved underlayment on the worksheet and used a different peel and stick to finish the roof. Have contractor submitt a revision for the two types of peel and stick underlayment used or remove and use appoved underlayment list on the work sheet. | |||
| WALL SHEATHING | 12/27/2021 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/21/2021 | APPROVED | LMILLER |
| ROOF SHEATHING | 12/21/2021 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 11/17/2021 | APPROVED | JWALKER |
| FOUND SURVEY APPROVED (OFFICE) | 09/27/2021 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 07/29/2021 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION 3 column pads rear of building need to have 4 #5 each way. | |||
| MONOLITHIC SLAB | 07/28/2021 | Disapproved - NO FEE | JWALKER |
| Note: 3 column pads rear of building need to have 4 #5 each way. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 07/13/2021 | APPROVED | JGIBSON |
| ELECTRIC TEMP POLE | 06/23/2021 | APPROVED - AS NOTED | JMUNSON |
| Note: Emailed FPL at 9:19 am | |||
| WATER METER INSTALLATION REQUEST | 06/04/2021 | APPROVED | TCHURCHILL |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 01/12/2023 | 01/12/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/19/2022 | 08/19/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/19/2022 | 08/26/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/19/2022 | 08/19/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/24/2021 | 09/27/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/24/2021 | 09/27/2021 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/27/2021 | 04/28/2021 |
| Note: Released By: ESTELLE LENS - (386)986-2655 - | |||
| SWALE | COMPLETE | 04/16/2021 | 07/13/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/15/2021 | 04/21/2021 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 04/15/2021 | 04/21/2021 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 04/15/2021 | 04/19/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/15/2021 | 04/16/2021 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 04/15/2021 | 04/19/2021 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/15/2021 | 04/16/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/15/2021 | 04/22/2021 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KKRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/15/2021 | 04/20/2021 |
| Note: Held By: ESTELLE LENS - (386)986-2655 - Four foundation plantings are required on each side of the residence. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 01/20/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 01/20/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 01/20/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 01/20/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/20/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/20/2023 |
| CONTRACTOR CHANGE | ¤40.00 | 08/30/2022 |
| BUILDING DISCOUNT 100% | (¤1,460.00) | 04/30/2021 |
| ELECTRIC FEE | ¤240.00 | 04/30/2021 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.01) | 04/30/2021 |
| IMPACT FEE FIRE | ¤367.00 | 04/30/2021 |
| IMPACT FEE PARKS | ¤1,199.12 | 04/30/2021 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/30/2021 |
| IMPACT FEE TRANSPORTATION | ¤1,718.00 | 04/30/2021 |
| MECHANICAL FEE | ¤240.00 | 04/30/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/30/2021 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/30/2021 |
| 3% PARKS IMPACT FEE CREDIT | (¤35.97) | 04/30/2021 |
| PLAN CHECK FEE | ¤120.00 | 04/30/2021 |
| PLUMBING FEE | ¤240.00 | 04/30/2021 |
| NEW RESIDENTIAL INSPECTIONS | ¤600.00 | 04/30/2021 |
| SITE PLAN 20 | ¤20.00 | 04/30/2021 |
| SURCHARGE FS 533.721 | ¤2.00 | 04/30/2021 |
| SURCHARGE - FS 468.631 | ¤2.00 | 04/30/2021 |
| CONNECTION FEES | ¤1,017.83 | 04/30/2021 |
| METER - DEPOSIT | ¤60.00 | 04/30/2021 |
| METER - DEPOSIT | ¤60.00 | 04/30/2021 |
| WATER-METER | ¤441.07 | 04/30/2021 |
| WATER- TURN ON | ¤25.00 | 04/30/2021 |
| WATER- TURN ON | ¤25.00 | 04/30/2021 |
| ADMIN FEE | ¤20.00 | 04/30/2021 |
| STORM WATER PERMIT FEES | ¤80.00 | 04/30/2021 |
| 3% TRANS IMPACT FEE CREDIT | (¤51.54) | 04/30/2021 |
| SEWER CREDIT | (¤1,466.00) | 04/30/2021 |
| SEWER INSPECTION | ¤25.00 | 04/30/2021 |
| SEWER CAPITAL FACILITY | ¤4,664.55 | 04/30/2021 |
| WATER CAPITAL FACILITY FEE | ¤3,424.45 | 04/30/2021 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤15,439.00 |